Document ga8RXYRV6pzakMk8857m6bB2L
nEPORTNO.- P-1766
JOBNO.- 43-000-760.22-1016005
PROCESS FOR ENGINEERING DESIGN
FOR MONOCHLOROBIPHENYL
DATE- July 29, 1974
WRITTEN BY D. R. Cova
nn ST. LOUIS. MISSOURI
Atm* R< )/*?
cc;
cc::-:. -t: |
i . i,,L
MONS 040741
Research and Development Report No. P-1766
PROCESS FOR ENGINEERING DESIGN FOR
MONOCHLOROBIPHENYL
Job No. 43-000-760.22-1016005
July 29, 1974
Written by: D. R. Cova
Work done by: D. R. Cova K. K. Holbert
. B. P. Manoff
-COMPANY CONFIDENTIALMONS
t Distribution of
Report No. P-1766
t
1. Technical Reports Library - Permanent Copy 2. Technical Reports Library - Loan Copy 3. Technical Reports Library - Loan Copy 4. Circulate to MICC Director, Technology Planning 6
Evaluation, Managers, RfiD, then to Technical Reports Library - R2Z9 5. K. R. Richard 6. Q- E. Thompson 7. R. H. Munch 8. J. F. Quinn 9. D. R. Cova 10. J. R. Savage - Manufacturing 11. J. E. Maurer/K. H. Duffey - Patent 12. T. L. Gossage/C. Paton - Marketing 13. K. E.Boucher - TSD 14. Gary Johnson - Manufacturing IS. V. C. Engman - TSD 16. A. E. Leisy - Manufacturing 17. D. K. Lynch - WGK PPR
This report contmlna confidential information which is the property of Monsanto Industrial Chemicals Company and shall be disclosed only to duly authorized persons. The recipient is held accountable for the filing and safe custody of the report which must be returned on demand.
MONS 040743
TABLE OF CONTENTS Page No.
INTRODUCTION.................. '....................................................... 1 SYNOPSIS OF PROCESS ........................................................... 1 CHEMISTRY OF PROCESS .......................................................... 1 YIELDS AND RAW MATERIAL REQUIREMENTS ....................... 2 PROCESS FLOW DIAGRAM ........................................................... 4 MATERIAL BALANCES................................................................... 5-6 PROCESS IN DETAIL...................................................................
I. Steady-State Process .................................................. 1 II. First Fractionation Batch .................................... 10 DISCUSSION OF VARIABLES........................................................... 12 RAW MATERIAL SPECIFICATIONS ......................................... 27 ANALYTICAL PROCEDURES .................................................. . 36 PRODUCT SPECIFICATIONS ...................................................... 38 PHYSICAL CONSTANTS DATA........................... '..................... 43 SAFETY AND TOXICITY DATA....................................................... 47 ENVIRONMENTAL PROTECTION........................................................54 APPENDIX
(
HONS 04074A
CBP DCBP MCBP PCB o m P
ABBREVIATIONS
Chlorobiphenyl Dichlorobiphenyl Monochlorobiphenyl Polychlorobiphenyl ortho meta para
MONS 040745
INTRODUCTION
Monochlorobiphenyl (MCBP) consists mostly of the isomer, ochlorobiphenyl. Its only use is as an intermediate for the manu facture of o-phenylphenol. This report provides information for the design of facilities for its manufacture in the Aroclor De partment at the W. G. Krummrich Plant.
In the manufacture of MCBP large quantities of Aroclor byproduct are formed. These are converted to Aroclor 1242. The market for Aroclor 1242 is limited. This places a limitation on the amount of byproduct that can be disposed of in this way. At the present time, byproduct corresponding to about 8FT lb/yr of MCBP can be disposed of in the Aroclor 1242 business. An increase in MCBP manufacture above 8M lb/yr will require either incineration of excess byproduct or else a change in the pro cess for handling it. Also, plant capacity will be limiting at or near 8R lb/yr.
SYNOPSIS OF THE PROCESS
Biphenyl is chlorinated to Aroclor 1111. This material is then fractionated through a 30-tray column. The fractionation is carried out semi-continuously. Three cuts are taken: a large forecut consisting mostly of biphenyl which is recycled to chlorination; an intermediate fraction (or slop cut) which is recycled to the following fractionation batch; and finally, the product fraction. The still residue (which is large) is straight takeover distilled. This distillate is chlorinated to Aroclor 1142, isomerized over AlCls, then distilled again, Porocel treated and can then be sold as Aroclor 1242.
CHEMISTRY OF PROCESS
The only reactions carried out are chlorinations of biphenyl or Aroclors to various concentrations of chlorine. In the first reaction, biphenyl is converted to an Aroclor containing an average of lit chlorine.
Molecular Weights
Biphenyl 154.20
Chlorine 70.91
XHCI
Cl Aroclor 1111 *>
172.65
Hydrogen Chloride 36.47
* Aroclor '1111 is a mixture of homologs ranging from unconverted biphenyl (40-45t) to small amounts of trichlorobiphenyls. Monochlorobiphenyls are present in 44-48t concentrations and dichlorobiphenyls in 4-7% concentrations. The molecular weight
-CONFIDENTIAL-
MUNS 040746
2-
was calculated from the chlorine concentration and thus represents the mixture.
In the second chlorination, distilled residue (containing about 23.7% chlorine) from monochlorobiphenyl fractionation is chlorinated to Aroclor 1142.
Molecular Weights
<HQ)C1*
Aroclor 1124* 200.1
y
Chlorine 70.91
Aroclor 1142* 260,5
y+z
Hydroqen Chloride 36.47
* Again, these compositions are mixtures of homologs and the molecu lar weights were calculated from the chlorine concentrations.
YIELDS AND RAW MATERIAL REQUIREMENTS
A. Yields
.
. Following are percent yields of monochlorobiphenyl based on ( the theoretical possible yields.
On biphenyl On chlorine
58.7% 32.St
Since a saleable product, Aroclor 1242, is produced in large
quantities along with the monochlorobiphenyl, total yields were also calculated as a percent of theory. That is, the
following yields are for the total of both products taken together in the same proportion as shown in the material bal
ance (100 lbs. of monochlorobiphenyl and 68.0 lbs. of Aro clor 1242).
On biphenyl On chlorine
96.lt 97.31
B. Raw Material Requirements
. Following are raw material requirements for 100 lbs. of monochlorobiphenyl.- It should be kept in mind when consider ing these quantities that 88.0 lbs. of Aroclor 1242 is pro duced simultaneously with the 100 lbs. of monochlorobiphenyl.
I -CONFIDENTIAL-
HONS 040747
-3-
Raw Materials Required for 100 lbs, of Monochlorobiphenyl
Biphenyl Chiorine
FeCli Lime A1C1 > Scrubber Liquor*
139.2 lbs. 114.6 lbs. '
0.18 lbs. 1.25 lbs. 0.23 lbs.
70.0 lbs.
* It should be stated that scrubbeT liquoT is used in the scrubbing column whenever chlorinations are underway and that it eventually ends up as saleable product (Aroclor 1254).
Since sizeable quantities of Aroclor 1242 will also be produced,
raw material requirements for 100 lbs. of this product are given below.
Monochlorobiphenyl residue Chlorine
FeCl, Lime AlCli
81.1 lbs. 49.5 lbs.
0.03 lbs.
0.51 lbs. 0.26 lbs.
(
(
-CONFIDENTIAL -
HONS 040748
TMU I stubt-joti noczss miaou muncs
T3 0BO3 in
-03 O O'
INiji.im J.ij I't- uL the tojicLt spctiiic yruvily as this
determines the composition of the Aroclor to be fraction ated:
Stage Number
1 2' 3 4
at*3S*CC GraVity 1-002
1.022
1.039
1.056
A total of 39.5 lbs. of HC1 offgas (Stream 5) is given off by the chlorination reaction. This stream contains 7.7 wt I organics, most of which are condensed out when the gas is cooled to 80*C. The condensate, 2.7 lbs. of
Stream 6, is collected separately for future conversion to Aroclor 1254. The cooled offgas (Stream 7) is mixed
with the offgas from residue chlorination (Stream 30). The total stream is sent to the offgas scrubber where it is contacted with scrubber liquor (distilled residue from
the Aroclor. 1016 process). Most of the organics in the offgas are removed. It is estimated (on the basis of
plant experience) that the scrubbed gas (Stream 12) will contain about 45 ppm total PCB's. Fresh scrubber liquor
is fed continuously to the liquor surge tank (70.0 lbs. of Stream 9). 70.4 lbs. of spent liquor is withdrawn con tinuously from the system to maintain a constant level. This material. Stream 10, is converted to Aroclor 1254.
-CONFinnNTIAL-
U1
rwass ?io* stair
-8-
(
In order to minimize PCB's in the scrubbed gas and to prevent condensation of solid biphenyl from the, scrubbed gas onto piping surfaces, the concentrations of biphenyl and of total monochlorobiphenyls and dichlorobiphenyls must be held below 1 wt t of each in the scrubber liquor (i.e., biphenyl <1.01 and total monochlorobiphenyls + dichlorobiphenyls <1.0%). Some additional control can be exerted over this by adding chlorine to the scrubber liquor surge tank or into the scrubber column sump to chlorinate some of the biphenyl absorbed in the liquor. In the material balance enough chlorine (0.12 lbs. in Stream 11) has been added to convert most of the absorbed biphenyl to monochlorobiphenyls.
Crude Aroclor 1111 from the chlorinator (Stream 1!?) must be treated with lime before fractionating. The purpose of lime treatment is to react out dissolved HC1 in the crude Aroclor before it enters the fractionation system. This will prevent corrosion problems in the column. Lime is slurried in Aroclor 1111 (0.8 lbs. in 7.8 lbs. of Aroclor). This slurry is added to the crude Aroclor 1111 as it is pumped into the intermediate storage tank.
( B. Aroclor 1111 Fractionation
227.9 lbs. of limed Aroclor 1111 is charged to the stillpot of
the 30-tray distillation column. The system pressure is re
duced to 330 Torr and the system is brought to reflux. Head
and stillpot temperatures will be about 220 and 246'C, re
spectively. After the system has lined' out at total reflux,
distillate flow is started forward to the forecut receiver
at a reflux ratio of 3/1. At the same time,limed Aroclor 1111
is fed into the stillpot at the same rate as distillate is
drawn off. This is continued until 55.0 lbs. of forecut has
been collected. The reflux ratio is now increased to 5/1,
and distillate flow is continued into the forecut receiver.
The feed of limed crude into the stillpot is continued until
99.1 lbs, of crude has been fed. Crude feed is now stopped
and slop cut from the previous fractionation batch is started
feeding into the stillpot. When 40.3 lbs. of slop cut
(Stream 19) has been fed to the stillpot, the feed is cut off
_ and the reflux ratio is increased to 15/1. Distillate flow
' to the forecut receiver is maintained until the column head-5
temperature shows a rise of 2*C. This signals the end of the
foTecut and the beginning of the slop cut. ISS.JJbs. of fore- '
cut will have been collected and sent back for rhlnrlnation
------
to AroclOT ljJ.J_. Distillate flow is diverted to the slop
, cut Teceive_Tj__*
Distillate is taken off at a reflux ratio of 15/1 throughout the entire slop fraction. As the slop cut is taken off, the
-CONFIDENTIAL-
MONS 040753
-9-
column head temperature will rise, indicating the depletion
of biphenyl from the system. The head temperature will level out again at about Z40'C (indicating pure o-CBP, at the column head). This leveling out of temperature is the first indica
tion of the end of the slop cut. The distillate should be sampled at this time and the biphenyl concentration determined (by GLC or by refractive index measurement). Figure 10 or 12 in the appendix can then be used to determine precisely How far the distillation has proceeded. The amount of slop cut
yet to be removed can then be readily calculated from these figures. The slop cut is ended when the biphenyl concentration in the distillate has fallen to 2-J. By the time the slop cut
is ended, 40^3 lbs, of this fraction will have been collected (Stream 22). I he reflux ratio is now lowered to 8/1 and the distillate flow is diverted to the product tank. Stillpot
temperature at this point is 264C.
The column head temperature will remain at 240'C through most of the product fraction. When the o-CBP has been de-
?leted from the system, the head temperature wili_begin to rise. his is an indication that the end of the product/fraction is
near. When the head temperature has risen to 25the dis
tillate is sampled and tne crystallizing point is determined. Pigure 14 in the appendix is then used to determine precisely how far"the distillation has proceeded. How much more distil late to take off can be calculated from this figure. When the crystallizing point of the distillate reaches 53 "C. the pro duct fraction is finished. At this point 100 lbs. of product MCBP (Stream 23) will have been collected.
The fractionation system is now shut down and the column is
allowed to dump into the stillpot. The residue (73.4 lbs.
in Stream 24) is removed from the stillpot and stored prior to
distillation.
-----
C. MCBP Residue Distillation
The fractionation residue (Stream 24) is straight takeover distilled at 40 Torr. In a batch distillation the stillpot temperature will range from 190*C at the start to 2S0*C at the end of distillation. Vapor temperature will rise from
1B8*C to 222*C. The distillation can also be carried out semicontintiously, in which case the temperature ranges may be - come smaller. 69.1 lbs. of distillate is produced (Stream 27) and 2.1 lbs. of residue (Stream 26). The residue is stored for future distillation in a Montar still. The dis tillate is chlorinated to Aroclor 1142.
D. Chlorination of Distilled Residue
MONS 040754
The distilled residue is chorinated batchwise (and not con tinuously) at 150*C in the presence of 0.05t FeCl3 catalyst
-CONFIDENTIAL-
-10-
CO. 03 lbs. in Stream 28). The distilled residue analyzes at 23.31 chlorine. 43.6 lbs. of chlorine (Stream 29) is sparged
into the reaction mass. This will bring the specific gravity at 65'C to within the range, 1.354-1.356. At this point the reaction mass should be sampled and the content of 4,4'-DCBP determined by GLC. Fig. 15 in the appendix shows normal levels of 4,4'-DCBP in the reaction mass versus specific gravity. The 4,4'-DCBP level of the finished reaction mass must not exceed
3.5 area t. If the level is above 3.5 area 4, more chlorine can be added to the batch. In no case, however, can the specific gravity at 65*C be allowed to exceed 1.361.
The HC1 offgas (Stream 30) is mixed with the cooled offgas from biphenyl chlorination and is passed to the offgas scrubber.
The crude Aroclor 1142 (90.1 lbs. in Stream 31) is passed on
to the isomerization step.
E. Isomerization of Aroclor 1142
0.23 lbs. of AlClj (Stream 32) is added to the crude Aroclor 1142 from chlorination. This gives a level of 0.254 A1C13 in the reaction mass. The mass is heated to 250*C and is held
there for 5 hours. At the end of 4 hours the mass is sampled and the 4,4'-DCBP level determined by GLC. This level should
( be no higher than 2.6 area 4. If this level has not been achieved after 6 hours of reaction, additional AICI3 catalyst should be added to the reaction mass and it should be held at temperature for another 4 hours. The finished reaction mass is treated with
lime before distilling.
F. Aroclor 1142 Distillation
0.4$ lbs. of lime (Stream 34) is added to 90.3 lbs. of isomerized Aroclor 1142 (Stream 33). The Aroclor should be well
contacted with the lime over a period of at least 2 hours. At the end of this time the material can be straight takeover distilled at 40 Torr. The distillation can be carried out batchwise or semi-continuously. In the laboratory in batchwise
distillation the stillpot and vapor temperatures ranged from
225 to 264*C and from 220 to 241*C, respectively. 2.7 lbs. of residue (Stream 37) is produced in this distillation and 86.0 lbs. of distilled Aroclor 1242 (Stream 38). The distillate
is passed through a Porocel column at 65*C to produce finished
' Aroclor 1242 (88.0- lbs. in Stream 39).
II. First Fractionation Batch
MQNS 040755
The first fractionation batch differs from subsequent batches in that there is no recycle slop cut from a previous batch. This
( first batch is described in this section, starting from limed Aroclor 1111 and ending with the end of the fractionation batch. Tne materinl balance for this batch is given in Table IA.
-CONFIDENTIAL-
-11TABLE 1A MCBP FRACTIONATION - FIRST BATCH
(
Stream
Composition, wt *
Biphenyl o-Chloroblphenyl m-Chloroblphenyl p-Chloroblphenyl 2,2'-D1chlorob1phenyl Other PCB's and Lime
Total, lbs.
Temp, *C Pressure, Torr Volume, gals.
Stillpot Stlllpot
Slop Product
Charge Feed Forecut Cut
Cut Bottoms
44.4 44.4 95.7 35.0
0.48
28.7 28.7
4.8 65.0 81.4
2.3
3.2 3.2
3.92 9.7
17.5 17.5
13.3 61.9
1.2 1.2
.66 4.6
4.7 4.7
20.7
251.9 144.8 172.2 33.9 100.0 90.6
150 760 30.2
150 760 17.4
80 330 21.0
80 330
3.8
80 330 10.8
270 460
10.8
HONS 040756
-12-
( The process description gives no details of process control since this has been covered in part A, the steady-state process.
2S1.9 lbs. of limed Aroclor 1111 is charged to the stillpot of the 30-tray fractionator.- The system pressure is reduced to 330 Torr and the system is brought to reflux. Head and still-
pot temperatures will be 220 and 246"C, respectively, at this time. After the system has lined out at total reflux, distil
late flow is started forward to the forecut receiver at a reflux ratio of 3/1. At the same time, limed Aroclor 1111 is fed into
the stillpot to maintain a constant level. This is continued until 66.0 lbs. of forecut has been collected. The reflux ratio
is then increased to 5/1. Distillate flow to the forecut re ceiver and feed to the stillpot are maintained. When 144.8 lbs. of crude has been fed to the stillpot, the feed is cut off
and the reflux ratio is increased to 15/1. Distillate flow to the forecut receiver is maintained until the column head temperature shows a rise of 2*C. At this point, the distillate
flow is diverted to the slop cut receiver. 172.2 lbs. of fore cut will have been collected.
As the slop cut is taken off, the head temperature will rise
and level out at about 240*C. This indicates that the slop cut
is almost complete. After analysis of the distillate has shown that the slop cut is finished (less than 2t biphenyl in the dis-
( tillate), the distillate flow is diverted to the product re ceiver and the reflux ratio is reduced to 8/1. 33.9 lbs. of Slop cut will have been collected. Stillpot temperature will now have risen to about 267*C.
The column head temperature will remain at'240oC through most
of the product fraction and will begin to rise near the end. When the temperature has reached 250*C the distillate should be sampled for crystallizing point measurement. On this first run it would be desirable to place the column on total reflux short of the end of fractionation while a representative sample
of the material in the product tank is analyzed by GLC. After analysis, it can be decided how much more distillate should be taken off. When the product fraction is ended (100.0 lbs. of
fraction), the fractionator is shut down, and 90.6 lbs. of residue are pumped to residue storage.
DISCUSSION OF VARIABLES A. . Chlorination of Bip.heny.l
MGNS 04075 7
1. Chlorination Temperature and Catalyst Concentration
Laboratory experiments have shown that a 0.03% feTTic chloride charge (based on biphenyl) is entirely adequate ( for this chlorination. In fact, earlier work by Helmut ' Merten on the preparation of Aroclor 1242 has shown that
-CONFIDENTIAL-
-13-
catalyst concentration o 0.0051 is sufficient provided the biphenyl temperature is above 110 when initial chlorin ation is commenced. For this reason we recommend a minimum chlorination temperature of 120'C and a catalyst 'concentra tion of 0.051.
2. Chlorine Purity
Calculations of off-gas vo1up.cs, etc., are based on a feed of pure chlorine. In practice, the chlorine feed may con tain air (perhaps 25 volume 1). A low chlorine content does not hurt the quality of Aroclor 1111 produced, but the presence of excess inert gas contributes to loss of organics in the off-gas stream.
3. Chlorination Level
The object of producing Aroclor 1111 is ultimately to ob tain monochlorobiphenyl with a minimum of di or higher chlorinated biphenyls. In order to hold down formation of the higher chlorobiphenyls, it is necessary to limit the amount of chlorination in the distillation feedstock. Chlorination levels of about 10-121 have been found to be optimum. Chlorination below lOt requires excessive biphenyl recycle. In the following fractionation the forecut size, already large, would be increased still further.
As the chlorine content of the Aroclor is increased over lit, the rate of formation of polychlorobiphenyls increases rapidly while that of the monochlorobiphenyls is decreasing. This has two detrimental effects. Firstly, the amount of residue from MCBP fractionation is increased. This residue is converted to Aroclor 1242. The market for this product is limited. Any residue beyond that required to fill this market need would, at this point, have to be disposed of by incineration. This is not desirable, so it is best to minimize residue. Secondly, one of the polychlorobiphenyls that would increase rapidly is 2,2'-DCBP. This isomer boils quite closely to p-CBP and is difficult to separate by fractionation. 2,2'-DCBP comprises most of the polychlorobiphenyl found in MCBP. We can only meet the polychlorobiphenyl specification on MCBP because the level of 2,2'tDCBP in Aroclor 1111 is low (about 1.61). Higher levels would again necessitate larger residues and less MCBP product with, by the way, less p-CBP isomer.
4. Chlorine Gas Distribution
From the point of view of homolog distribution the optimum reactor configuration is a batch chlorination. In batch chlorination monochlorobiphenyls would be maximized while biphenyl and polychlorobiphenyl levels would be minimized.
-CONFIDENTIAL-
HONS 040758
-14-
The next best is a continuous chlorination carried out in
a series of stages. The more stages there are, the more closely the final product will approach that.found in a batch
reactor. Aroclor 1111 will be made in a 4-stage .continuous chlorinator. To obtain the best homolog distribution it is essential that the chlorine gas feed be distributed evenly
to all 4 stages. Any gross variations from this gas dis tribution will cause an increase in the undesirable homo logs. This will lessen the yield of MCBP,.possibly lessen
its quality, and increase the size of the residue stream.
5. HC1 Solubility in Crude Aroclor
The solubility of HC1 in AtocIot is a function of tempera ture. Figure 9 in the Appendix shows this function. From this it should~be possible to reduce dissolved HC1 in Aro
clor 1111 by raising the temperature in the last chlorina tion stage. Temperatures above 150*C are not practical,
however, because of the high vapor pressure of biphenyl. Any reduction in dissolved HC1 is desirable because it would reduce the amount of lime to be added to the crude
to neutralize the acid.
. 6. Dlspositon of HC1 Offgas
.
The HC1 offgas from the chlorinators is cooled to 80*C.
At this temperature it still contains 3.7 wt t biphenyl and about 0.31 chlorobiphenyls. These must be further reduced
before the offgas leaves the department. The polychlorobiphenyls must be reduced because of environmental consider ations. Biphenyl must be lowered (to 0.006 g biphenyl/ Std ft3 of gas) to prevent its condensation as a solid in piping at ambient temperature. This reduction can best be carried out by passing the offgas into the HC1 scrubber now in the department. This scrubber uses distilled resi due from the Aroclor 1016 process as scrubbing liquor.
Chlorobiphenyls in the offgas will be condensed out and dissolved in the liquor. Biphenyl will also be dissolved in the liquor. Because of the large amount of biphenyl in the offgas and because of its relatively high vapor
pressure, it is best to keep its concentration in the scrubber liquor low. This can be done by chlorinating it
. up to chlorobiphenyl.
Chlorination of biphenyl-rich scrubber liquor in the scrubber liquor hold tank was simulated in the laboratory. Scrubber liquor from the department (in use in the scrubber . for about one week) was spiked with biphenyl. Chlorine gas ( was then slowly sparged into the stirred mixture at 45*C. Chromatographic analysis of samples of the reaction mass showed a disappearance of biphenyl as the chlorine was
-CONFIDENTIAL-
MQNS 040759
-15-
( added. Chlorine was added at a rate of 3g chlorine/lOOg
of reaction mass/hr. Figures 7 and 8 show biphenyl con centration as a function of chlorine added and as a function of time. At the It level, it was calculated'that l.Sg of biphenyl reacted for each gram of chlorine added: This means that 87% of the chlorine added at this biphenyl level reacted to form monochlorobiphenyl. The partial pressure of biphenyl above scrubber liquor containing It or less of
biphenyl should give a scrubbed offgas containing a level . of biphenyl well below the dewpoint at the ambient temper
ature.
In order to keep the levels of chlorobiphenyls low in the
scrubbed gas, the levels of monochlorobiphenyls and dichlorobiphenyls in the scrubber liquor must be kept below
It for the total of these components. Since biphenyl is chlorinated to form these compounds it may be desirable (if scrubber liquor availability becomes tight) to chlorinate
only part of the biphenyl absorbed, just enough to keep its level below It.
B. Monochlorobiphenyl Fractionation
Practionation Requirements
Experiments in the laboratory were designed to simulate fractionation in the 30-tray column in the Aroclor Depart ment. The same number of trays was used, and the column holdup-to-charge ratio was approximately the same. These two variables were not changed in our experiments. It can
be readily stated, however, that a decrease in number of trays or an increase in column holdup would reduce the separating efficiency of the system. This would be un
desirable.
The reflux ratio program was optimized to some extent.
Further optimization may be possible in the plant. For the present the stated program should be followed. Lower re
flux ratios should not be used. Higher reflux ratios should give no problem (except for capacity reduction) except pos
sibly in the tail end of the fractionation where a high reflux ratio may cause too high a concentration in the distillate of m-CBP. The meta isomer is undesirable in MCBP and is slightly lower boiling than p-CBP which can be tolerated (up to a point) in the product.
2. Crude Feed/Charge Ratio
This Tatio is based on a crude Aroclor 1111 containing 42-461 biphenyl and a slop fraction of 40.3 lbs. The ratio was set such that during the time the column was being fed, distillate could be taken off at Teflux ratios no
-CONFIDENTIAL-
,, HONS 040760
-16-
higher than 5/1. A higher feed/charge ratio would cause biphenyl to be depleted from the system while the stillpot
was being fed. To prevent losses of o-CBP in the forefrac tion it would be necessary to place the column at a higher
reflux ratio. This would teduce column capacity.. Crude
containing lower biphenyl levels or a larger than normal slop fraction would have the same effect, i.e., depletion of biphenyl during the feeding stage. An increase in the column head temperature would indicate biphenyl depletion. This should be countered by Increasing the reflux ratio. If this becomes a persistent problem, the feed/charge ratio should be lowered. A lower ratio should only cause a lower capacity unless the change is quite large whereupon there may be detrimental effect on product quality and yield.
5. Column Pressure
In the laboratory column head pressure was set at 430 Torr. This gave a stillpot pressure of about 460 Torr which
is the stillpot pressure expected in the plant when the column head is set at 330 Torr. 330 Torr was the head pressure used in the plant in making MCS-1109 (an impure
monochlorobiphenyl) and should be adequate here. Except for the effect on column loading and tray dynamics, small
changes in this pressure should have no effect on the pro
cess.
4. Control of Fractionation
There are six points in the fractionation cycle at which some control action must be taken. The following paragraphs take each of these points in sequence and discusses them at length. The discussion starts with the column already at total reflux.
4-1) Start forward
The column is operated at total reflux until all the column temperatures have lined out. This will allow the
initial column concentration gradients to be established. When this state has been achieved, distillate flow is cut forward to the forefraction receiver at a reflux ratio of
3/1. ' At the same time limed Aroclor 1111 is fed to the stillpot to maintain a constant liquid level.
4-2) When 55.0 lbs. of forefraction has been collected the reflux ratio is Increased to 5/1. Distillate flow to the forecut receiver and feed to the stillpot is maintained.
If the column head temperature should begin to rise (2*C above the normal level) before this point is reached, the reflux ratio should be increased to 5/1 immediately. If this becomes a common occurrence the reflux ratio should be set to increase before the rise in head temperature is
-CONFIDENTIAL-
MGNS 040761
-17-
( expected. This will Teduce the loss of o-CBP to the fore cut.
4-3) End of crude feed
'
When 99.1 lbs. of forecut has been collected, the feed of limed crude is stopped and the slop fraction from the previous fractionation batch is fed to the stillpot on
level control.
4-4) End of all feed
When all of the slop fraction (40.3 lbs.) has been fed
to the stillpot, feed is stopped and the reflux ratio is increased to 15/1- Distillate flow is maintained to the
forecut receiver. If the column head temperature consist ently shows an increase of more than 3 or 4*C before this
point is reach, it would be desirable to reduce the amount of limed crude fed to the stillpot.
4-5) End of the foTefraction
The end of the forecut and start of the slop cut is
signaled by an increase of 2*C in the column head tempera ture. At this point, distillate flow is diverted to the
( slop cut receiver. As an indication of the sensitivity of this control technique, if the cut is made at a 4*C increase
instead of 2*C, the size of the slop fraction will be re duced by about 4t. This would lower the size of the product fraction in the next fractionation batch by only about
0.51.
It should be noted that if head temperature shows an increase before the reflux ratio is increased to 15/1 (point 4-4), it will most likely show a decrease shortly after the reflux is increased. This will then be followed by the increase signalling the end of the forecut.
4-6) Start of the product fraction
When the head temperature begins to level off again
the start of the main fraction is near. Head temperature
is not sensitive enough to signal the exact cut point. Other means must be used. The most desirable way in which . to cut into the product receiver is such that the biphenyl concentration of the entire product fraction will be less than 0.6t. Laboratory studies show that this cut point will occur when the biphenyl concentration in the instan
taneous distillate is between 2 and 3t. Probably the best , way to determine this cut point is to first determine it
( approximately either from the leveling off of the head temperature or from the amount of slop fraction collected.
HONS 040762
18-
Then at this approximate cut point (or slightly before) a sample of instantaneous distillate is obtained and the con centration of biphenyl in this sample is determined. Fig. 10 in the appendix gives a plot of biphenyl concentration TK instantaneous distillate as a function of total charge distilled (feed plus original charge). From the concentra tion of biphenyl in the distillate and using Fig. 10 one can determine how near to the exact cut point the instil lation has proceeded. One can then calculate how much more distillate must be taken off before cutting into the pro duct fraction. Figure 10 was determined in the laboratory and should provide a goocT guide for the first few fraction ations. A similar curve using_plant_ data should be developed as soon as possible to provide a more exact guide.
The concentration of biphenyl in the distillate can be determined by GLC. This method unfortunately is not instan taneous but it is the method of choice for the first few batches. Another method which can be used is measurement of the refractive index of the distillate sample. Fig. 11 in the appendix relates biphenyl concentration to re fractive index. This can be used in conjunction with Fig. 10 to determine the cut point, or Fig. 1^2 which plots the variation of refractive index with percent of the total , charge distilled can be used directly.
At the same time as the distillate is cut into the product receiver the reflux ratio is lowered to 8/1.
4-7) End of the product fraction
The column head temperature will be constant through the first part of the product fraction. It will then begin to rise as the o-CBP is depleted from the system. This is the first signal of the approach of the end of the pro duct fraction. The head temperature is not sufficiently sensitive to be used as the control point. The crystal lizing point of the distillate appears to be best for con trol. Fig. 1_3 in the appendix plots crystallizing point versus concentration of p-CBP. Fig. 14 plots crystallizing point versus percent of total charge HTstilled. It is thought that when the head temperature has risen 10*C above the o-CBP boiling point plateau, a distillate sample is obtained, and _ its crystallizing point is determined. From this crystal ' lizing point we can place exactly where we are on Fig. 14 and determine from this curve the volume of distillate yet to be taken off before ending the product fraction and terminating the fractionation.
The fractionation must be terminated in such fashion that ( the product specification on m-CBP and PCB contents are met.
That is, m-CBP content must be less than 4.01 and PCB con tent less than 1.04 in tho product fraction. Fig. 14 was
-CONFIDENTIAL-
HONS 040763
-19-
(
developed for a laboratory fractionation. It is essential that such a curve be developed from plant data. This should be done during the first few batches. GLC's'of representa tive samples of the product already collected can be used to great advantage here as well as GLC's of instantaneous distillate samples. In these first few batches the column can be placed on total reflux while awaiting analytical results.
5. Effect of Variations In Charge Composition
Changes in the degree of chlorination of the Aroclor 1111
will cause changes in the fractionation material balances. If the variations are large enough, this could cause the product to go out of specification as well as affect the yield and capacity of the plant. It is highly desirable that variations in Aroclor 1111 composition be minimised.
6. Lime Treatment of Crude
The purpose of lime treatment is to react out dissolved HC1 in the Aroclor before it is fed into the distillation sys tem. The amount of lime given in the process material bal ance is based on plant experience at a time when air blow( ing of crude had been discontinued.
It is essential that the treated Aroclor entering the dis tillation system be checked for the absence of HC1. An analytical method is presented in the appendix. Analysis of the crude entering the lime treatment will help ensure that an adequate amount of lime is being fed to the process. If analysis indicates that higher than normal concentrations
of HC1 are present, the lime feed rate should be increased.
Mixing in lime treatment must be sufficient to keep the lime suspended and to ensure adequate contacting between
lime and crude Aroclors.
7. Slurrying of Lime
Lime is fed into the Aroclor 1111 stream as a concentrated slu^Ty (lOt by weight of lime) in Aroclor 1111. This Aroclor
_ has a lower flash point (121*C) than Aroclor 1142 and so * precautions such as cooling must be taken before charging
the lime. Aroclor 1111 is the material of choice for slurry making for two reasons. Firstly, the use of higher Aroclors as Aroclor 1142 will cause an increased residue from MCBP fractionation. Secondly, this will cause problems further down the line when MCBP residue is converted to Aroclor
( 1242. The presence of these higheT Aroclors in the resi due will cause the formation of an Aroclor 1242 product with too high a level of 4,4'-DCBP.
-CONFIDENTIAL-
MONS 040764
-20-
8. Crystallizing Point of Distillate
The crystallizing point of distillate was found to range from 70*C at the start of distillation when almost pure
biphenyl was coining over, down to near room temperature when the distillate was high in o-chlorobiphenyl concentra
tion, and up again to S5*C towards the end of fractionation. Distillate lines and receivers will have to be heated to prevent solidification.
9. Corrosion
The material of construction of the distillation column is stainless steel. Stainless steel is prone to stress cor rosion cracking in the presence of inorganic chlorides.
For this reason it is essential that crude entering the distillation system be free of HC1. HC1 is removed from the crude by treating with hydrated lime to remove the
residual HC1 chemically.
It should be mentioned at this point that the stillpot is constructed of steel. Steel should be impervious to the calcium chloride formed in the lime treatment step.
10. Product Storage
Product in storage should be kept above the freezing point of o-CBP which is 32.4*C. This will prevent the formation of solids. In the laboratory (at about 20*C) some samples
of MCBP turned mostly solid after several days of sitting.
Chlorination of MCBP Residue to Aroclor 1142
1. Concentration of the 4,4'-DCBP Isomer
4,4'-DCBP has a high melting point (148*C). For this reason only a small amount can be tolerated in Aroclor 1242. Otherwise this compound may precipitate out of the Aroclor at low temperatures. Fig. 1 in the appendix plots
the solubility in Aroclor 1016 (essentially equivalent to Aroclor 1242) of 4,4'-DCBP at various temperatures. Aro clor 1242 made by chlorination of biphenyl contains 2.5 area t 4,4'-DCBP. It is essential that Aroclor 1242 made
by chlorination of MCBP residue contain no more than this
level of 4,4'-DCBP.
MCBP residue contains about 568 p-CBP. This Isomer is a
precursor to 4,4'-DCBP. As the residue is chlorinated, the level of 4,4'-DCBP rises from about 4 area 8 to a maximum of 17-18 area 8, then begins to fall as chlorination is continued. When the chlorination level has reached that of Aroclor 1142, the reaction mass contains about 3.2 area 8 of 4,4'-DCBP (as compared to 2.5 area 8 in normal
-CONFIDENTIAL-
MONS 040765
Aroclor 1142 -- see Fig. 1_5 in the appendix). This level is then further reduced by isomerization over AlClj.
The levels of 4,4'-DCBP given in Fig. 15 represent levels
which we believe can be achieved in baTch chlorination in
Aroclor Department equipment. We know of various Conditions
that can cause higher levels of 4,4'-DCBP to be foraed.
These are discussed below.
'
a. It is essential that the chlorination be carried out batchwise and not in the continuous equipment. Con tinuous chlorination would give Aroclor 1242 with a wider spread in homologs and, consequently, a higher level of 4,4'-DCBP.
b. Chlorine gas bubble size will have an effect. Very
small bubbles (as formed through a frit) will cause a wider homolog spread and higher levels of 4,4'-DCBP. Fortunately, the gas spargers in the Department will give larger rather than smaller bubbles, so this should be no problem in the plant.
c. Higher catalyst levels (0.54 FeClj compared to 0.054
normal level) and higher reaction temperatures (250*C compared to 150*C normal) will cause higher levels of 4,4'-DCBP in the finished chlorination mass.
d. The most serious problem (in that it will probably occur in the first batch of a MCBP run) is contamination of the Aroclor 1111 with more highly chlorinated Aroclor, as Aroclor 1142. This contamination will be concentrated
in the MCBP residue. The effect of its presence will be to give a MCBP Tesidue with a higher than normal degree of chlorination. This means that less chlorine will be added to bring the residue to Aroclor 1142. The effect on the 4,4'-DCBP concentration will be as though the residue were under chlorinated. The level of 4,4'-DCBP in the Aroclor 1142 will be higher than normal. As an example, Aroclor 1111 made in the Aroclor Department batch chlorinators was contaminated with about 0.54 Aroclor 1154. The Aroclor 1142 made from MCBP residue fromthis--crude contained fBoutLjL. 0. area 4 4,4'-DCBP- Tf this becomes a problem in the plant, what can be done is to overchlorinate .slightly to bring the 4,4'-DCBP down to normal levels. This overchlorina tion however must be such as not to exceed a specific gravity at 65*C of 1.361. Otherwise the finished Aro clor 1242 will be out of specification on pour point and viscosity. It is absolutely essential that contamination with Aroclor 1142 be minimized as much as possible to prevent this problem occurring.
-CONFIDENTIAL-
MQNS 040766
-22-
D, Isomerization of Aroclor 1142
1. AICI3 Catalyst Level
The process calls for a level of 0.2S% AlClj. Higher levels than this may cause corrosion of the steel reaction vessel. Lower levels may give no isomerization or insufficient iso
merization. If, on isolated batches, isomerization does not take place, more catalyst should be added.
2. Reaction Temperature
Temperatures above 250C may cause tar formation. Lower temperatures may not give isomerization. Temperature seemed to have little effect on corrosion of steel.
3. Moisture
It is essential that the catalyst and reaction mass be pro tected from moisture. AlClj will react with water, forming
HC1. The isomerization reaction will not take place if moisture is present or if the materials have been exposed
to moisture.
4. Reaction Time
The isomerization should be essentially complete in 4 hours. We recommend that the batch be sampled and analyzed for level of 4,4'-DCBP after 4 hours. If the level is 2.6 area I or less, the reaction can be terminated.
5. Corrosion
A 30 hours test of steel showed uniform corrosion at a rate of 4 mils/year. We recommend that corrosion coupons be placed in the plant isomerization reactor to follow corrosion over a more extended time period.
E. Distillation of Isomerlzed Aroclor 1242
1. Lime Treatment
. . The'crude isomerlzed Aroclor 1142 should be contacted with * O.St lime for 2 hours before being distilled. This will
ensure that the AlClj catalyst has been killed. Otherwise colored distillate may be obtained, and it may be contami nated with AlClj which has sublimed over.
2. Distillation Conditions
The distillation was carried out batchwise in the labora tory at a pressure of 40 Torr. Suitable product was obtained
-CONFIDENTIAL-
MONS 040767
with up to 97.01 of the charge being distilled over. Once
the crude has been suitably treated with line there should
be no difficulty in distilling semi-continuously (i.e.,
with crude feed to the stillpot).
',
Miscellaneous
1. Changeover from Aroclor 1016 to MCBP
The only difficulty seen here is the effect of contamination of MCBP streams with Aroclor 1142, causing higher than
normal levels of 4,4'-DCBP in Aroclor 1242 made from MCBP residue (see the discussion under part C-l of this section
of the report). It is essential that this contamination be held down to a minimum. Plant experience will give us fur ther guidance.
2. Changeover from MCBP to Aroclor 1016
This problem has already been faced in the Department when
MCS-1109 was produced tneTe. MCS-1109 was a form of MCBP.
What was learned in that changeover can equally well be
applied here.
.
3. Critical Process Variables
In the following table are listed those process variables, their proper values and allowable tolerances which are criti cal to satisfactory operation of the process. The selection of these variables for inclusion in the table should not
be taken to mean that all the other process variables are of no consequence. It is only that these are of special importance.
MQNS 040760
Variable
TABLE II
ALLOWABLE VARIATIONS IN CRITICAL PROCESS VARIABLES
Value
Allowable Variation
Effect
CSLORIKATIOK TO MOCW* 1111
Specific gravity of Aroclor 1111
.
1.056 at 85 *C
.001
Too much variation here will upset the fractionation material balance, reduce product yield, and possibly cause out-of-spec product.
Chlorine split to aa^> stage
17.75 lbs/hr
0.9 lb/hr
If too much chlorination is performed in any one
stage, the hocaolog distribution will be widened.
. Unconverted biphenyl and PCB levels will increase
and product yield will decrease.
NCBP FRACttOHATIOW Lisa treatment
Colum hud pnasura Stlllpot inti Control
emulative distillate flow
330 Torr *20,000 gal.
No free BCl Excess line 5 Torr 100 gal.
100 gal.
Inadequate lime treatment will allow free BCl to
Is)
-*>
enter the colum. Ails will cause stress corrosion 1
cracking.
Larger variations may cause the colmn to flood or dwp.
Increases in level may cause excessive entrainment into the column. Lowered levels will cause losses of o-CBP to the forecut.
Cumulative distillate measurements are used in the forecut to determine points of changing rsflux ratio and end of crude and slop cut feeds to the stillpot. Late changes will cause loss of o-CBP to the forecut.
HONS 040769
Variable
Bead tecpersture at end of forecut
Value *222*0
Refractive index of distillate *1.6088 at start of product fraction at 20*C
TAB12 II (coat'd.) A1lovable Variation
2*C
0.0002
Effect
This temperature rise signals the end of the forecut. A late change will cause loss of o-CBP to the fore cut. An early change will cause the slop cut to be large and high in biphenyl.
This signals the start of the stain fraction. An early change here would cause the product to be out of specification on biphenyl content. A lata changa will decrease the size of the product fraction.
Crystallizing point of distillate at end of product fraction
53*C
CHLORINATION TO AROCLOR 1142
Specific gravity of reaction mass
4,4'-DCBP content of finished raction naes
1.355 at 63*C 3.1 area %
t 0.5*C
to.0001
0.3 area %
This signals the end of the stain fraction. A lata change here will cause the product to be out of specification on *-CBP and possibly also on PCS's. An early change will decrease the size of the product fraction.
VN>)
Variation outside this range will cause the Aroclor 1242 product to be out of specification.
Highar than normal levels of 4,4'-DCBP will most likely have been caused by contamination with highly chlorinated biphenyls. If this is the case, the 4,4'-DC8P level can be lowered by slight overchlorination, not over a specific gravity of 1.361 at G5*C.
ISOMERIZATION Reaction toperature
250*C
t 10*C
Higher temperatures may cause tar formation. Lower temperatures may give insufficient isomerization.
level of 4,4*-0C8P in finished reaction mass
2.5 area I
<. 2.6 area %
Higher levels of 4,4'-DCBP may cause problems of solids formation at low temperatures during consumer use of the product.
M0NS 040770
_________ Variables ,
Aroclor 1242 QXSTTLLATIOW Collar of distillate
Value
Table XX - Uatinoid
Allowable Variation
Effect
IS AFBa
< 20 area
a high color will naan insufficient line treatment
of tha Aroclor 1142 crude or else entr&inaent of
stillpot liquid into the vapor.
'
N9*
HONS 040771
RAW MATERIAL SPECIFICATIONS HONS 040772
Monsanto
-2882601
...
DIPHENYL (BIPHENYL)
RAW UATITR1AL SPECIFICATION
UUiMTIPi A. E. Leisv J. Leyerle
mol wt. 154.20 tVPtMQMS 2/6/69 . NMUCTIIUITII
WGK
246 SURRLIBR
.10/23/70
Anniston Plant
APPROVAL! ICH % ,
. M m---------.------ -- QUAaLIT--YB---CONTROL fCMyf*tf_C_h_M_l_a_i)_!_J__________________
R. Blowers
c>-o
CMCMCAL FORMULA
: _ 2 x 16 os. W.M.
LIMITS
J.MU..SY *
MQTMQR
UNRESTRICTED INFORMATION
(R) .Appearance and Color
Light Yellow Cryst. Solid
10,252
(R) Crystallising Point (R) HjO GENERAL. INFORMATION
68.7*C. , min. ppm me*.
10,298 13,155
Distillation Range:
.
' First Drop to
2.5*C., max.
10,299
Dry Point
Must include 2S5*C. within range
This specification is the property Of Monsanto Company and is for
internal use only.
'
HONS 040773
Monsanto
RAW MATERIAL SPECIFICATION
PARDU6TI9N A. E. Lelsy
J. Leverle
T. W.
-29-
iiAk eoc 38800 PLANT W.O.K.
V7/70 APPROVAL*
Dalton
MAT MlAL Lime, Hvdrated WIN* OCPTt. 287. 7S0. 246
_
Mississippi Lime Co.
W. R. Richard QUALITY CONTROL (CMf CAmiIiO
B. R1nMT4.Q ________________________ _ CMKMCAL POAMULA
Ca (0H)2
B/IV69LL 16 na. W.M. Rnfcfcle
Appearance
Assay (Ca(OH)g) Carbonates as
(CaC03) Magnesium Sulfates (as S03)
Pine white or slightly gray powder, free from lumps or gritty material. 92.000, min.
3.00jt, max. 0.500, max.
0.300, max.
10,188
10,191 10,193 10,192 10,189
Supplier's certificate of analysis to be sent on day of shipment to:
Chief Chemist, Monsanto, Sauget, Illinois
(tO Rssfla* AsWftli, All MAn At\mly*+4 tr re|ui< infh
HONS 040774
Monsanto
W. C, Kruromrich Plant RAW MATERIAL SPECIFICATION
PAAO. CUEM.CMtLNYelsv J. Leyerle
IICWtATI.M
, -30-
33500 WGK
Ferric Chloride Anhydride 233
Jan. 31, 196< APPROVALS
ntte*acM
McKesson It Robbins .
.
W. R. Richard
'
* eoNTaok. fCMsf CAiifstf
R. Blowers T, Bell
CHAMICAL -O-MUL A
mol wt, 162.21
Fe Cl,
lAHRbK PON ANAITIII 1x8 os. W.M. Bottle
LIMIT*
UNRESTRICTED INFORMATION
IIIMBD VT Hlggerson/Stites MCTMOO
J.F.Q.
Appearance
Black powder or Granules
16-A
Assay
97.0%. rain.
.
22-570
Sulfate s
0.05%, max,
120-570
Ferrous Salts
Trace, max.
S-570-1
Solubility:
112-B
' 10:10 of Water
Complete to (lightly . turbid, max.
10:10 of Formula 30 Alcohol
Complete to (lightly turbid, max.
i MQNS 060775
^,n** Monsanto Chemical Company
monOANIC CHKMICALI OIVISION
RAW MATERIAL
( SPECIFICATION
ym irrirrm---------------12/7/67
tssut *6.
,
-31-
Chlorine P6I UII iu-----------
WOK
103 SUPPLIER*
Liquid URBRMOBA .
Monsanto - WGKrummrich Plant
"* Q XOSf Internal 18850 External
7/11/66
Pittsburgh Plate Glass
production (rim* klrnmpr/ O D. Dreasel_______________ R. F. Neunuobsl AUTHOR'ISO (V**tty UtfflPl IIamUt/
Diamond Alkali
APPROVALS rkicarch Mia DintturJ r , Pirry, J r. QUALITY CONTROL (OtUf
W. J. Gresham
QCNKRAL OCSCairriON
A clear* heavy liquid* amber to greenish yellow in color. For use in the manufacture of ACL products.
eMARACTSftimc* Appearance
Assay - cl, Iren as FsClj. 6 HjO
as Fe Non-Volatile
Matter. Moisture, H.O
UMTS
A clear amber to greenish-yellow heavy liquid 99.5% Min. 0. 005%, max. 10 ppm max. 40 ppm Max,
40 ppm, max.
PFAA*0 .
MCTNOO MO. 10,748
....
10,688
10,660
(
T# MOMS 040776
-32-
Monsanto
W. G. Krummrich Plant RAW MATERIAL
8.1059
SLANT
W.G.K.
fhlnrinp 236, 237
SPECIFICATION
2/8/72
*
APPROVALS
WOTvTRFB------------------------------------------------------
\ W. Dalton
D. R. Dill
'.
.QWALItV CONTROL (Chief CheaafeO
R. M. Blowers
CMKMICAl PORMULA
Cl2
NEW
Color Chlorine Moisture (H20) Sulfate Carbon Tetrachloride
PONIUPLK
AMALvata
LIMITa
R.Sorrell/S-Shaultcr MCTHOO
Amber to Greenish Yellow
10,748
95%, tlin.
75 ppm, Max.
12,793
10 ppm, Max.
500 ppm, Max.
* No current vendors specification identified by Research.
Supplier's certificate of analysis to be sent on day of shipment to: Chief Chemist, Monsanto., Sauget, Illinois 62201.
flO RtWMi AnMfSlli Atl lMn Analysed %y feginal nlp>a
MQNS 040777
i;i;IaAnvaki; river rusfrr
n.v.-
it::: tat jvc
1
incaticm
t.. Snniosol 100
PROe'Gl/JD JpV J. C. Wyji'ant
M* '` ALUMINUM CHLORIDE ANHYDROUS trttjfr-
CHEN 1 CAL FOSCULA
aici3
. J. Quinn -1- Delaware** River J. H. Wi IImore -4- Dc-litv/j re R tver r. R# ftirkcr !- Delaware River J.j. Connolly -l- Delaware River
L.J. Ewmj; -l- Delaware River Q. E.Thompson -1- CO/T3E J. F". Ilerber -1- C0/T;)0 J.C. Wygant -1- GO/T3E Standards Dept. -4- JFQ
::0L.t.'T. 133.3-1
Zrr-c.% jvi wit it.
1/25/71!
i 1/21/74
,
sy.-'PUz\'Js
roasample
analysis
________ STAUFFER CHEMICAL COMPA NY*4-oz. WM Glass- Stoppered Ponies
IJOTl: all samples processed by this tentative SPECIEICATION WILL REOUIRE DISPOSITION or
THE AUTHORIZED RELCASINC A CENT.
TESTS
UNRESTRICTED PURCHASE LIMITS
________ PROCEDURES
On each loc Appearance
,
Grayish to light yellow crystalline
powder
:
D.R. 13-354
J-F-Q16-A
Identity tests: Aluminum Chlorine
Positive Positive
62-11560
Iron Upon request
Aluminum chloride (AICI3)
Aluminum, free
0.05% maximum
98.5% minimum 0.01% maximum
13-356 70-11560
. 13-358 22-11560 77-11560
Subllmablcs
98.5% minimum
Water Insolubles
0 12% maximum
- 13-359 66-11560
Relapsing Information
1. All shipments must comply with these specifications. Monsanto, at its option, may elect to
accept material not meeting specifications provided notification is given by the vendor before
shipment Is made.
-
2. Shipper's analysis, covering the above specifications and any other routinely determined proper ties, will be mailed to the Chief Chemist, Delaware River Plant, the aame day shipment is made.
*3. The Manufacturing Department will sample and submit samples from 4 or 5 containers for anslysls.
HONS 040778
The specification shown here for AICI3 is for the actual material used in the laboratory work. Suppliers other than Stauffer Chemical Company can certainly be considered, but their AICI3 should be checked out in laboratory studies to make certain that it is suitable for this pro cess.
HONS 040779
Hasp--------------
YSZToZ MATDMii.
Nitrogen Gas
RAW MATERIAL
jL. ^GK
See Below (3)
IPECIPICATION
H .3/29/68
Air Reduction Sale* Co.
'
*eeHovAL
.
J.y. M.
T. W.D.
R. H. Mllla
ODeG.
O.D.D.
" E.D.M.
J.M.C.
.
E.L.M. VALITV COHTHOC (CAM
.J.A.S. .
W. j; Greeham
'
'
Grad* - O. P. Special Nitrogen
itMUIUI OIUII__"
2/18/65 INUUtlMTIt
....... iwi * Ihil--------------------- lUusa at
L. E. Hornback
UMT
M9NM
A..ay (1) Oxygen Hydroget) ' Day Point
-Nitrogen > '
' Argon
Oxygen Carbon Dioxide i - Acetylene
`
-99.9%, min. ' 0.1%, max. .
0% -76 *F.
'
Typical Analyeie 99.78% 0.12%
. . 00005% .00005%
(2)
(1) . Nitrogen plae inert rare gaie* i
(21 . - Any analyeee to be obtained from eupplier on requeet.
(Jj- 212, 244, 246, 247, A-282, A-216, 269, 267, 270, B-270 k 211.
HONS 040780
-36C ANALYTICAL PROCEDURES
A chromatographic procedure for analyzing mixtures df biphenyl and monochlorobiphenyls is included in the appendix. This method will be required to analyze Aroclor 1111 and the final product, MCBP, as well as process streams from fractionation. Also in the appendix is a procedure for measuring acidity in limed Aroclor 1111. A chromatographic method for determining the level of 4,4'-DCBP in Aroclor 1142 or 1242 is given in the appendix. These will be required in the residue chlorination and Aroclor 1142 isomerization steps. For all other specifications and analyses, analytical method numbers are given on the specification sheets. The following table (Table III) indicates sample frequency and analyses required for process control.
(
( -CONFIDENTIALMONS 040781
Step
Stream 5 No.
TABLE III SAMPLES, FREQUENCY AND ANALYSES
Frequency of Saapline
Sample Size
Chlorination to Aroclor 1111
Crude Aroclor 1111'- Stress 13
4 to 8 hours
1 quart
MCBP Fractionation Lined crude Stream 16
Slop Cut Stream 22
m Product Cut Stream 23
w m Product cut Stream 23
Every 24 hours
Once or twice each batch near end of slop cut
Once or twice each batch near end of product cut
Once each batch
1 pint
1 pint of
instantaneous distillate
1 pint of instantaneous distillate
1 quart, of sam ple representa tive of total product fraction
Chlorination to Aroclor 1142
Reaction mass Stream 31
Once or twice each batch near end of chlorination
1 quart
Isomerization
Reaction mass Stream 33
Once each batch after 4 hours of reaction
1 pint
Aroclor 1242 Distillation
Distillate Stream 38
Once at start of run
1 quart
Finished Aroclor 1242
Product Tank Stream 39
Once for each dis tillation batch
3x4 pint bottles
Analyses Required
Specific gravity at 85 or 65*C Free SCI and excess lime GLC orRI for % biphenyl
Crystallizing point
GLC and other analyses for speci fications
Specific gravity at 65*C
GLC for content of 4,4'-DCBP
Distillate color to maJte certain lime treatment was adequate. All analyses required for specifications.
-37
HONS 040782
-38-
(
PRODUCT SPECIFICATIONS
c
MONS 0407B3
-39
Tentative specifications for Aroclor 1111 have been included below strictly as a guide to aid in manufactureof MCBP.
AROCLOR 1111 (Tentative Specifications)
The following specifications have been derived from laboratory analyses and experiments. Deviations from these specifications may cause
deterioration of yield and quality of the final product.
Biphenyl Concentration o-Chlorobiphenyl
m-Chlorobiphenyl f-Chlorobiphenyl
,2'-Dichlorobiphenyl
< 481 26-1/2*
0-3.5* > 15*
< 2*
The following tentative specifications are required
for the manufacture of Aroclor 1242 from MCBP
residue.
.1
Aroclor 1142 before isomerization
area t 4,4'-DCBP 3.51 max.
(
Aroclor 1142 after isomerication area * 4,4'-DCBP 2.6* max.
Tentative specifications for MonochloTobiphenyl:
Composition
Biphenyl
0.6* max.
o-Chlorobiphenyl
80.0 min.
m-Chlorobiphenyl
4.0* max.
p-Chlorobiphenyl
Remainder
Folychlorobiphenyls
1.0* max.
Physical Properties
Sp. Gr. 2S*C/15.S*C Refractive Index * 25*C
1.152-1.162 1.6092-1.6112
-CONFIDENTIAL-
MONS 040764
Monsanto
W. G. Itrumrorich Plant FINISHED PRODUCT SPECIFICATION
PRODUCTION
A. E. Lc i sv
AL
C. Paton
peftouet
Arcelor 1242 , Electrical Grade
PL AMT
PAOQuct CooC
lespr.
1 246
W.G.K.
ottl KPItCTtvl
811.01
' *Al( tool
Sales. to 810.90
9/8/72
1040-241-16-03
APMKOVALA
W. P. Richard *
# QUALITY CONTROL (CMnl ChttnltV
H. J. Horner
'
CMCMIC AL FORMULA
MOL WT.
lAAMPLC rOM AMALV9I9
luUgiD IV
10/22/69
13 x Ot Amber Bottles |R.McCutchan/S.Shaulter
IIMITIC
LIMIT#
UNRESTRICTED INFORMATION
(R) Color (APHA
(R) Condition
(Ri Sp. Gr. 9 25/15.5`C.
iR) Acidity (mg. KOH/g.)
(R) Moisture (HjO)
(R) Refractive Index 9 25"C.
(R) Inorganic (Free) Chlorides
(R) Pour Point
'
(R) Dielectric Constant
(60 cycles 9 100'C.)
40, Max. Clear
1.381 - 1.392 0.010, Max. 35 ppm., Max.
1.6240 - 1.6260 0.05 ppm., Max.
-14*C. or lower
4.75 - 4.95
10,084 10,084 10,114 10,087
10,620 10,125 12,741
10,115 T-2273
(R) Hydrolysis Stability Test (As Chlorides)
0.5 ppm., Max.
1*672
!R) Monsanto Stability Test (As Chlorides)
0.4 ppm., Max.
11,503
IR) Distillation Range (ASTM D-20, Corrected)
10% Distilled by Wt. 90% Distilled by Wg.
325C., Min. 360^., Max.
10,117
Sulfates Dielectric Strength 9 25*C.
Flash Point (eF) Fire Point
Hone 35 KV, Min.
338 - 392 None
12,169 11,605 10,123 10,123
Corrosion Test (16 hours. 9 IlCC. with bright .Aluminum Foil.) Change in wt. of A1 %
0.0
A.C. Color (APHA) A.C. Condition
A.C. Acidity (mg. KOH/g.)
A.C. Inorganic (Free) Chlorides Vise. 9 100*F. (SUS)
60, Max. Clear 0.010, Max. 0.05 ppm., Max.
82 - 92
10,084 10,084 10,087
12,741 10,086
(R) Power Factor 9 lOO^C.,
Bulk
60 cycles, Max. Drums
(H) Rvui/m A maty $ it. All ethmr* Aumly ltd by rifniil Only
Internal Customer 0751-- --O T-2273 2.0 4.0'
GENERAL INFORMATION - PAGE 2
tO
o*o
</>
-41-
Characteristics
GENERAL INFORMATION
Specific Heat S 25"C.
Coefficient of Expansion (25-65'C.)
Fixed Chlorine
'
SPECIAL CUSTOMER REQUIREMENTS
General Electric Thermal Chemical Chlorides
Westinghouse
Hydrolizable chlorine (Westinghouse Stability Test)
Limits
0.30 0.00068'cc/C. 42.5 - 43.54
0.65 ppm., Max.
1.0 ppm., Max.
Methods
12,722 T-2219
(
(
MONS 0<0786
' monsamo
W . C. Krummrich h Anniston
FINISHED PRODUCT
j SPECIFICATION
*K#*i*fi*N
Ault.________________ ___
-42mmumn - - * -- *
-
nsev.
/-i.i
Aroclor 1242 Non-Electrical Grade 1WGK240 27 wnsr---------------------- pr6oUIt CVBK------------
WGK t, Ann.
81101-82612
Sales
10AV7-5 IWUIM
1040-240-04/11/16-03/09
"" '
'
uuty
icwemim
a. :i. 3lower3
...................
IMIMH FORMULA
Mixture
t^iRiuy
*
0/23/67
M4RI.S MS AWUVIM
3 x 16 oi. W. M. Bottles
UMT
UNRESTRICTED INFORMATION
() Condition <R> Color, A PHA (R) Sp. Cr', (25/15. 5*C.) (R) Acidity (mg. KOH/g.) >*) Moisture (HtO) {ppm)
Cleer 100 mtx. 1,381 - 1.392 0.010, mex. 50, max.
|S. Sis,,itL'r/J. CLitj*
Mf|
WOK 10084 10084 10114 10087 10620
Anniur.on G-l 046 052 050 047
Distillation Range
{ASTM D-20 Corrected)
10% Distilled by wt.
90%
.................. .
Viscosity fil00*F. (SUS)
Flesh Point (*F)
Fire Point
325'C. , min. 360 *C., mex.
82 - 92
338 - 392
None
10117
14-31 54
10086 10123 10123
049 14/6 54 14-28 54
(
MONS 040787
PHYSICAL CONSTANTS DATA
Specific gravities of MCBP were measured. The results were
Temp. c
Specific Gravity
20-1/2
1.161
54 1.133
70 1.120
MONS 040788
-44
PHYSICAL CONSTANTS DATA
A ;i I' 'I .CM i 142. fTrchnicn 1J_
it MUC*I III* 4L*I oImvi a
O.AVT547
l(i \ M. Ellfnhiire I _NAMt_________
In r. nhi -_-_---
k ___
7/5/57 Total Clt41. 5 - 42.57.
iguf.'e.nyi___ _Sl)JCCt 12-2Lij-i____
llrown lo black oiTv i i`lt>jS|3Z?>Er.`i..1 ':JM -'54__ "
lr-i i * . .; .1
ltmi.il' -'- lU.ii... JDIL.
Unlaw runt * Itnitm, rr.it-t 4 ._JS!!1...
Ciw;t.il: ;u.,; Hcinl
l&liiit I'a-j
r'T) _________ ______ ____
Sji^nti."i-.iii._____ 65/15.5c
1.348-1, 360
Sik-cs 12-21-5-1
_
Syrijij mi inly ___25/15. S^C Pm'*'. 0 si. >r> *C
10. 5
Cm llif-t t A
RriiwiuV
fall., Kri M^-huw (Hefrnnrr)___
Ijltl-i VtcM Spgctiwn
VtMV'ir _______________
Vi,.- 1*
_________
Stifle*; l c.'ilitii __________ L-i_______
S-kNmy fa __________
'$9H!biti!v hi . ____
- . ___ _____
Soli<biHy m _
. _________
Si-. Gr. 1cinp .CncXf45.0--.lQ5'GL-jJL-gflaflT
_SC5
Fust, Pci.n "r .iiawi c. o. c. fire f'-'-n4 C_____________
H-.r 1 O-iXiuMion______________
Item ol Fwriion___
Ib-fV n.illly Icat.Ai/eiiii.l (,.H-...I lim-l el Fmleg_________
Her.; M "IV*,_________ Spneilic Hen_____________
C,.licet Ttapeiatvn__________
Ctil-I:lClHWC_
ftum-.itiDC flpn-Jjrl
350 None
HONS 040789
Teimlr t'*** Krltttutfl
ScliWftrlz. ll.S. liiin.J.11 n 11fc Service I5ti 11. *' '-
I "Indiinlrlnl Piilsuns.^ .ll.-i^at-fe and-Solvcnt^"--
NOTE: Ft.ir 4witnl,in ,iiiImh,LAAjp lArMICtJ
i/ M^l'leONrtf *#! */ **.**>.
-4.S-
PHYSICAL CONSTANTS (Cont'd^J_ PHYSICAL AND CUBICAL DATA
plphcnyl Specific cravlty: 0.992 At 75e>C/*>C.
'
The swann chemical company bulletin of l';'>0 (;avc thermal data on diphenyl.
Viscosity of plphcnyl (from Anniston piles)
1CT~
170 ieo
190 200 220
250 >00
>50 400
440
4B2
Cent!poises
--nw
l.>09 1.206 1.114 . 1.0>4 0.001
0.752
0.57** 0.459 o.y/'i o;>i> o.28>
ric Heat (from Anniston
V
200 >00 400 500 bOO 700 800 900 1000
B.T.U./lb.
0.416 0.470 0.5*17 0.61b 0.658 0.679 0.686 0.690 0.696
w /7
MQNS 040790
-46-
PHYSICAL AMD CHEMICAL DATA (cont'd.
Diphenyl (cont'd.)
Another record gives the following values for liquid diphenyl:
c.- SP. Kcat cals ./gr-.i
100 150 200 250 500 550 400 450
Vapour CP ", o.46o ?5U'C.
0.560 0.580 0.412
0.460 0.518 0.575 0.610 0.625
0.625
s *p0oc. (D* A. Roper, Dcoign Data for units 4 & 5) penalty of Liquid Diphenyl (from Anniston files)
prams./eg
75 0.9885 100 O.9695 150 O.9294 soo 0.8885 850 0.8470 joo 0.8010 550 0.7510 400 O.6916 450 0.6100
Heat of vaporization; 65.4 p. cal,/g. at 258.5p.
o(
/I / it
MONS 040791
V.
-47-
V
Safety and Toxicity Data" Taken in part from the Standard Manufacturing Process for the Manufacture of Aroclcrs, in Dept. 246, W. G. Krummrich Plant. New material has been added, and some changes were made in the old material.
HONS 0*0792
-48-
Safetv Equipment
The following is a list of safety equipment (personal and depart
mental) required in department 246.
'
1. Fire extinguishers;
A. Dry Chemical (3) - Southwest corner Bldg. OR - Main Floor
- West wall at top of stairs of Second Floor.
B. Carbon Dioxide Snow - Southwest corner of Bldg. OR - ground level.
2. Chlorine Gas Masks (4) - Southwest corner, second floor
. - Control room, second floor
- Bast side, outside control room
. - Wall, Southwest corner of sprinkler house, main floor.
3. Scott Air Masks - West of Lean-To
4. Safety Showers (2) - Southeast corner of Bldg. OR - ground level.
- Southeast corner of Bldg. OR - 2nd Floor.
5. Davis Vapotester
6. Eve Baths
7. Sprinkler System
Safety Precautions
The following are safety precautions followed in the operation of department 246.
1. Safety Equipment of Employee
Each employee has the following safety equipment: (1) Sard hat,
(2) Safety glasses, (3) Goggles, (4) Rubber and canvas cloves, -(5) Rubber overshoes. Special equipment may be issued as
necessary for performing a particular job in a safe manner.
2. Sampling of Crude Aroclor
The samplc3,,oC Aroclor taken during the chlorination reaction
are hot (i50*C).
Precaution must be taken to avoid skin con
tact of samples and inhalation of Hydrogen Chloride, Chlorine
and Aroclor vapors.
HONS 040793
-49-
3. Fires
Fires may result from the ignition of leaking gas, Xylene, Diphenyl, rags, paper, wood, etc. Automatic fire extinguishers
and sprinklers have been installed to combat fires.
.4 Explosions
'
'
Explosions may be caused from accumulated pockets of natural gas
or a rapid burning of Diphenyl in a closed container such as a Chlorinator. Chlorinators are equipped with a 10' diameter pressure relief line with a rupture disc made to burst at 22 psi in case Diphenyl within the Chlorinator ignites.
5. Toxicity
Toxicity does not present a serious problem. However, a complete
daily change of clean clothes is supplied to each person and time is allotted at the end of each shift to take a bath. Instructions
are also issued to avoid actual skin contact with Biphenyl and Aroclor as much as possible and to wash hands and face before
eating.
6. Miscellaneous
There are many accidents that can occur that may be classified as health and safety hazards. These accidents may result from
such things sb broken process lines, acid leaks, steam leaks, etc.
The worst inherent hazards are as follows:
a. Free Chlorine from ruptured line or major leak. b. HC1 Gas from ruptured line or major leak. c. Dropping bottoms from stills. d. Hot Aroclor and Diphenyl.
CRUDE AROCLOR 1111
Toxicity: This material has a crystallizing point of 31.7* C. Since it is an Aroclor, it should have a medium toxicity range for liquid ingestion and high toxicity for vapor inhalation. The maximum allow able concentration (M.A.C.) is 1 mg/cubic meter.
Fire Hazard: Since this material contains high concentrations of bi phenyl, it is very flammable and will burn when exposed to heat or flame or oxidizing materials. It has a flash point of 121* C.
Other Hazards: This material can cause dermatitis, systemic poison ing from the fumes, and yellow atrophy of the liver. There are skin, mucous membranes and eye hazards encountered in handling this material.
treatment and Antidotes: Call a physician and remove patient from ( imas.
MDNS 040794
-50-
Storane and Handling! Protect the skin, lungs, and eyes by wearing
approved protective clothing, respirator, and goggles. People who
V handle this material at elevated temperatures should have medical
supervision, and the air should be sampled to insure compliance with
M.A.C, There are no special storage restrictions under normal condi
tions except store in a ventilated area.
,
Shipping: There are no special shipping restrictions.
FERRIC CHLORIDE (FeCl-j)
Toxicity: This material is a solid under normal conditions and is nontoxic or has a rating as low.
Fire Hazard: There is no fire hazard under normal conditions, but it
will emit toxic fumes at high temperatures.
Other Hazards: Some people are allergic to this material and may develop skin rash, and there is an eye hazard.
Treatment and Antidotes: Call a physician.
Storage and Handling: Protect the skin with approved protective clothing, avoid the breathihg of FeCl, dust, wear approved respirator
with adequate cartridge, and protect the eyes with approved goggles.
There are no storage regulations.
Shipping: There are no shipping restrictions.
DIPHENYL (C6H5C6H5)
Toxicity: This material is a solid at normal conditions and is medium toxic. The M.A.C. of vapor is 2 mg/cubic meter of air. If ingested the lethal dose is 2.4 g/Xg of body weight. The fumes are not danger ously deadly, but they are poisonous over a prolonged time.
Fire Hazard: Diphenyl is very flammable and will burn when exposed to heat or flame or oxidizing materials.
Other Hazards: Diphenyl is not too corrosive to skin, but it will affect the eyes. .
Treatment and Antidotes: Wash eyes with water and get the patient to fresh air. Try to get patient to vomit, and call a physician.
Storage and Handling: This material can be stored in steel containers away from fire hazards and oxidizing agents. Wear suitable clothes and approved goggles when handling diphenyl.
Shipping: Ship in cars or other suitable containers with a red warning ( label of flammability.
HONS 040795
-51-
LIME c(oii)2
( Toxicity: Lime is not dangerously toxic, and it is regarded as more of a nuisance. This material is a solid or slurry,
Fire Hazard: This material is not flammable.
Other Hazards: Lime is very hazardous to the eyes. It will burn the shin also, and the dust will affect the mucous membrane. '
Treatment and Antidotes: Flood eyes and skin with large quantities of water. If lime is ingested, get patient to vomit and call physician.
Storage and Handling: Lime can be stored in steel containers, and people should wear protective clothing, respirators, and rubber or chemical safe goggles when handling lime.
Shipping: There are no special restrictions for shipping, but the containers should have a white label, a caustic warning.
HYDROGEN CHLORIDE (HC1)
Toxicity: This material is a gas under normal conditions and is very
toxic. The M.A.C. is 5-10 ppm and a concentration of 1500-2000 ppm
would be fatal to humans in a few minutes.
.
Fire Hazard: There is no fire hazard under normal conditions, but wet ( gas reacts with some metals to form hazardous hydrogen.
Other Hazards: This material is hazardous to teeth, skin, eyes, and mucous membranes.
Treatment and Antidotes: Hash profusely with water, if injested, eat chalk, magnesium hydroxide, egg whites, and milk, and also administer oxygen. Call a physician.
Storage and Handling: This material Bhould be stored in a cool, well ventilatod area away from oxidizing agents. This material can be
stored in rubber lined, glass, or tantalum vessels. People handling this material should wear suitable clothing like rubber goggles or chemical safe grades and approved pack or canister gas masks.
Shipping: Shipping containers must have a white warning label and a non-flammable label. Ship in appropriate containers such as rail car
or carboy. .
CHLORINE (Cl2)
Toxicity: This material is a gas under normal conditions and is very toxic. The M.A.C. is 0.35 to 2 ppm. A concentration of 1000 ppm s would be rapidly fatal. Least concentration with detectable odor is ( 3.5 ppm.
MONS 040796
-52-
Firs Hazard! There ia no fire hazard under normal conditions, . but there is an explosion hazard if chlorine is mixed with a strong ( reducing agent such as hydrogen or hydrocarbons at high temperature.
Other Hazards This material causes eye, skin, and-mucous membrane
irritation.
.
-
Treatment and Antidotes The patient should be given oxygen immedi ately and treated for shock. Call a physician.
Storage and Handling This material should be stored in a venti lated and cool place away from fire hazards. When handling, wear a gas mask or approved respirator, clothing and rubber or chemical safe goggles. In strong chlorine concentrations, wear canister gas
masks, Scott air pack, or oxygen breathing apparatus.
Shippingi The shipping containers must have a green gas label and a non-flammable label on. Ship in steel cars or cylinders.
MONOCHLOROBIPHENYL
Toxicity: This material has a crystallizing point near rocm temper
ature. It tends to supercool, so that it is usually in the liquid form. It is an Aroclor and so should have a medium toxicity range
for liquid ingestion and high toxicity for vapor inhalation. The maximum allowable concentration is 1 mg/cubic meter.
r Fire Hazard: This material has some flammability, it has a flash point (open cup) of 154*C.
Other Hazards: This material can cause dermatitis, systemic poison
ing from the fumes, and yellow atrophy of the liver. There are akin, mucous membranes and eye hazards encountered in handling this material.'
Treatment and Antidotes: Call a physician and remove patient from fumes.
, Storage and Handling: Protect the skin, lungs, and eyes by wearing
approved protective clothing, respirator, and goggles. People who handle this material at elevated temperatures should have medical supervision, and the air should be sampled to insure compliance with H.A.C. There are no special storage restrictions under normal con ditions except store in a ventilated area.
Shipping: Thera are no special shipping restrictions.
AROCLORS 1242, 1254, 1142 and 1154
MONS 040797
Toxicity: This material is a liquid under normal conditions and has a medium toxicity range for liquid ingestion and high toxicity for vapor inhalation. The maximum allowable concentration (M.A.C.) is
( 1 ag/cubic meter.
Fire Hazard: There is no fire hazard under normal conditions. Aroclor mixes (Xylene, Toluene, Butyl Acetate, etc.) may burn and
explode at high temperatures when explosed to flames.
-53-
ALUMINUM CHLORIDE
Description: Yellowish-white granular crystals.
'
Formula: A1C13
Constants:
Mol. Wt. 133.35 M.P. 192.4*C B.P. 180.2*C (sublimes)
Density 2.44 Vap. Press. 1 imn ( 100.0*C
Toxicity: See Chlorides and Hydrochloric Acid
Disaster Control: Dangerous: when heated to decomposition, it emits highly toxic fumes of hydrochloric acid; will react with water
or steam to produce heat, toxic or corrosive fumes.
Storage and Handling: Section 7 of "Dangerous Properties of Industrial Materials" by Sax.
(
(
MONS 040798
-54-
^ EWVIRONMEWTAL PROTECTION
Thera is a total of six byproduct streams from this process. The largest of these is Stream 12,69.1 lbs. of scrubbed' MCI gas. Based on past plant experience in the offgas scrubbing tower, it is estimated that this gas will contain approximately 45 ppet of total sfehlorobiphenyls. It can be disposed of as is presently done by piping it to the chlorosulfonic acid department.
Two of these byproduct streams are distillation residues,2.1 lbs. of MCBP fractionation residue (Stream 26) and el.7 lbs. of Aroclor 1142 distillation residue (Stream 37). Both streams contain, besides PCB's, lime and PaCl), and Stream 37 contains, in addition, AlClj. Both streams should be passed on to a straight takeover still for recovery of polychlorobiphenyl values. The final residue from this distillation should be incinerated.
The last three waste streams to be considered are vent losses from
the various distillations. The vent loss from fractionation
' (Stream 20) was calculated on the basis of an air leakage rate of .
'/ 15 lbs/hr, and a condenser outlet temperature of B0*C. The total
organic vent loss amounts tO'0.31 lb/hr of which 0.08 lb/hr is '
monochlorobiphenyl (almost all'o-CBP). The rest (0.23 lb/hr) is
'biphenyl. PCB concentrations in this vent loss should be in the
ppm range.
t
( The second vent loss to be considered is Stream 25, vent loss from
distillation of fractionator residue. This vent loss was calculated on the basis of 15 lb/hr air leakage and a condenser outlet temper ature of 97*C. This vent loss is-2.7 Ib/hr. 66% of this is monochlorobiphenyls. The rest is PCB's. This quantity could be cut in half by distilling at 80 Torr rather than 40 Torr. Since the material is approximately 23% chlorine, it should be possible to do this. A further reduction could be obtained by paasing this vent stream through a cold condenser to reduce the gas temperature to perhaps 40*C. Most of the vapor passing the first condenser would freese out in this vent condenser. The condensate could be melted off the cooling coils at appropriate intervals and collected for incineration. In this way, the vent loss from the still would be reduced to 0.08 lb/hr of which perhaps 20% would be PCB's and the rest monochlorobiphenyls.
The last vent loss is from the Aroclor 1242 still. This loss is
estimated to be 0.08 lbs/hr of PCB's. However, since Aroclor 1242 is presently manufactured at the Xrumnrich Plant, actual plant ex perience should provide the best guide as to the actual vent loss.
It is very likely that, in the future, distillation vent losses will have to be reduced to lower the amounts of PCB's entering the atmosphere, especially if monochlorobiphenyl is considered as a PCB. It may be possible to do this by the addition of cold vont condensers or bads packed with solid adsorbents.
-CONFIDENT IAL-
hONS 040799
(
APPROVED:
-ssD. R. Cova
J. F. Quinn Manager, Engineering Technology
W. R. Richard Manager, R4D
J. R. Savage Manager, Manufacturing
ft. M. Kountz Managering, Engineering
( MONS 040800