Document gY08RNLyVGXmDZQ7Rve0703G

DownloadRandom document
Fluororesin Products for Manufacturing Processes of paper Lining tank (PTFE), lining piping (PTFE, PFA), lining valve (PTFE, PFA), insertion tube (PTFE, PFA), gasket (PTFE), bellows (PTFE, PFA) Flexible hose (PTFE, PFA), pliable hose (PTFE, PFA) PFAS used in the products is PTFE and PFA, which are polymer materials, and there is no concern about exposure, leakage, or environmental release of eluates. (Reference: SDS of PTFE in Daikin Industries, SDS of PFA in Daikin Industries) This product is to be used under the following conditions. Subject to use: Wetted parts of devices for storage, transportation and supply for chemical solution in paper manufacturing process. Fluid to be used: Hydrogen peroxide, Sodium peroxide, Chlorine dioxide, Hypochlorite, Chlorine, Sodium sulfite, Sodium hydroxide, Sodium chlorate, etc. Usage EnvironmentRT180 Use ConditionsNot to be affected by fluids in the use environment and no leakage. No elution of metal ions in chemicals Thought there are some materials to satisfy specification written above for example rubber with high-resistance for chemicals or Polyvinyl chloride, the former and the latter are lack of lifespan and strength each other.They affect productivity and product price. Reference: Plastic Data Handbook, Kogyo Chosakai Publishing Co., Ltd. As mentioned above, the presence of fluororesin product is essential for chemicals used in manufacturing processes of paper. We propose a regulatory exemption for the above reasons. Attachment 1: PTFE Safety Date Sheet r FDA IKt~ Printing date 06.02.2023 Safety data sheet Version number I Page 1/6 Revision: 06.02.2023 SECTION1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifier Trade name: POLYFLON PTFE M-12, 18, 18F, 391S, 392, 393 Article number: M 1.2 Relevant identified uses of the substance or mixture and uses advised against: No further relevant information available. 1.3 Details of the supplier of the safety data sheet Manufacturer/Supplier: DAIKIN INDUSTRIES, LTD. CHEMICALS DIVISION: OSAKA UMEDA TWIN TOWERS SOUTH 1-13-I Umeda, Kita-ku, Osaka-shi, Osaka, 530-0001, Japan Phone: Fax: Further information obtainable from: http://www.daikin.com/ 1.4 Emerrencv telephone number: Japan: China: +86-21-34151689 South Korea: Americas: CHEMTREC (Outside US/Canada: Europe: +49-211-179 225-0 SECTION 2: Hazard identification 2.1 Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008 The substance is not classified, according to the CLP regulation. 2.2 Label elements Labelling according to Regulation (EC) No 1272/2008: Not applicable Signal word: Not applicable SECTION 3: Composition/information on ingredients Information on ingredients: CAS: 9002-84-0 Polytetrafluoroethylene SECTION 4: First aid measures 100% 4.1 Description offirst aid measures General information: Seek medical treatment. After inhalation: In case of inhaling decomposed gases: supplyfresh air and consult a doctor in case of complaints. After skin contact: Immediately wash with water and soap and rinse thoroughly. After contact with the molten product, cool rapidly with cold water. Do not pull solidified product off the skin. After eye contact: Rinse opened eyefor several minutes under running water. Consult an ophthalmologist in case of complaints. After swallowing: If symptoms persist consult a doctor. 4.2 Most important symptoms and effects, both acute and chronic: Nofurther relevant information available. 4.3 Indication of any immediate medical attention and special treatment needed: No further relevant information available. SECTION 5: Firefighting measures 5.1 Extinguishing media Suitable extinguishing agents: Usefire extinguishing methods suitablefor surrounding conditions. For safety reasons unsuitable extinguishing agents: Nofurther information available. 5.2 Special hazards arisingfrom the substance or mixture: Formation of toxic gases is possible during heating or in case office. Attachment 2: PFA Safty Date Sheet r DAIKIN Printing date 06.02.2023 Safety data sheet Version number 1 Page 1/6 Revision: 06.02.2023 SECTION I: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifier Trade name: NEOFLON PFA AP-201, 202, 210, 220, 230, 201SH, 211SH, 215SH,221SH, 230SH, 231SH Article number: AP2 STD 1.2 Relevant identified uses of the substance or mixture and uses advised against: No further relevant information available. 1.3 Details of the supplier of the safety data sheet Manufacturer/Supplier: DAIKIN INDUSTRIES, LTD. CHEMICALS DIVISION: OSAKA UMEDA TWIN TOWERS SOUTH 1-13-1 Umeda, Kita-ku, Osaka-shi, Osaka, 530-0001, Japan Phone: Fax: Further information obtainable from: httpillwww.daikin.com/ 1.4 EmerRencV telephone number: Japan: China: +86-21-34151689 South Korea: Americas: CHEMTREC (Outside US/Canada: +1-703-527-3887) Europe: +49-211-179 225-0 SECTION 2: Hazard identification 2.1 Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008 The product is not classified, according to the CLP regulation. 2.2 Label elements Labelling according to Regulation (EC) No 1272/2008: Not applicable Signal word: Not applicable SECTION 3: Composition/information on ingredients Information on ingredients: CAS: 26655-00-5 Pmfluoro(alkoxy alkane) Additional information: For the wording of the listed hazard phrases refer to section 16. SECTION 4: First aid measures 100% 4.1 Description offirst aid measures General information: Seek medical treatment. After inhalation: In case of inhaling decomposed gases: supplyfresh air and consult a doctor in case of complaints. After skin contact: Immediately wash with water and soap and rinse thoroughly. After contact with the molten product, cool rapidly with cold water. Do not pull solidified product off the skin. Consult a doctor in case of complaints. After eye contact: Rinse opened eyefor several minutes under running water. Consult an ophthalmologist in case of complaints. After swallowing: If symptoms persist consult a doctor. 4.2 Most important symptoms and effects, both acute and chronic: No further relevant information available. 4.3 Indication of any immediate medical attention and special treatment needed: Nofurther relevant information available. SECTION 5: Firefighting measures 5.1 Extinguishing media Suitable extinguishing agents: Usefire extinguishing methods suitablefor surrounding conditions. For safety reasons unsuitable extinguishing agents: No further information available. 5.2 Special hazards arisingfrom the substance or mixture: Formation of toxic gases is possible during heating or in case offire. Attachment 3: Chemical resistance of various resins Attachment 4: Heat resistance of various resins Attachment 5: Purity of fluororesin VALQUA Handbook Technical Section