Document gLKOJZeYNKdOKdRoM4OEO9qq
Boilers
Weil-M'Lain
SCIENTIFIC COMBUSTION
BOILERS
WEIL-McLAIN COMPANY
Manufacturing Division
Michigan City, IndM Erie, Pa.
General Offices
Chicago, 111.
Smokeless Type
Weil-McLain Long Firing Period Smokeless Boilers are now making smokelessness popular with every one--for three primary reasons:--
First: They require considerably less firing attention than smokeless boilers in general.
Second: They are simple to fire.
Third: They are not limited to free burning types of soft coal for effective operation.
STEAM
Size
Rating Sq. Ft
72Z& 822-S 922-S 1022-3
752-S 852-S 9523 10523
7823 8823 9823 10823
7043 : 6043 9043 10043 11043 12043 13043
8443 9443 10443 11443 12443 13443 14443 15443 16443
1810 2105 2400 2695
2460 2995 3530 4065
4210 5060 5800 6550
6800 7850 8900 9950 11,000 12,000 13,000
8480 9605 10,730 11,855 12,980 14,105 15,230 16,225 17,125
WATER
Size
722-W 822-W 922-W 1022-W
752-W 852-W 952-W 1052-W
782-W 882-W 982-W 1082-W
704-W 804-W 904-W 1004-W II04-W 1204-W 1304-W
844-W 944-W 1044-W 1144-W 1244-W 1344-W 1444-W 1544-W 1644-W
Rating Sq. Ft
2990 3475 3960 4445
4060 4940 5825 6710
6950 8350 9570 10,810
11,200 12,900 14,600 16,300 18,000 19,650 21,300
13,990 15,850 17,700 19,550 21,400 23,275 25,125 26,770 28,250
Area Com-
- plete
Firebox at
Grate Sq. Ft.
Net
of Fuel Grates Sq. Ft.
7.03
8.11 9.19
10.26
4.88 5.% 5.96 7.03
8.10 9.30 10.50 11.70
5.70
6.90 6.90
8.10
11.47 13.22 14.97
16.72 .
7.97
9.72 11.47
13.22
15.00 17.50
20.00 22.50 25.00 27.50
30.00
11.40 13.90
16.40 18.90 18.90 21.40 21.40
20.85 23.60 26.35 29.10 31.85
34.60 37.35 40.10
42.85
15.35 18.10 20.85.
20.85 ' ` 23.60
23.60 23.60
23.60
23.60
580
Water Line Height Inches
46 46 46 46
51 " 51 51 51
55 55 55 55
57 57 57 57 57 ,, 57 57
58 58 58 58 58 58 58 58 58
Outlets and Inlets Number
and . Size Each Inches
2-3'/, 3-3'/2 3-3'/, 3-3'A
2-3'/, 3-31/5 33'/, 33'/,
2-4 3-4 3-4 4-4
2-5 3-5 3-5 4-5 4-5 5-5 5-5
3-5 3-5 4-5 4-5 . 4-5 4-5 5-5 5-5 5-5
mended Chimney
Sizes
12x12x40 12x12x45 12x12x50 12x12x55
12x12x45 12x16x45 16x16x45 16x16x50
16x16x50 16x16x55 16x20x55 16x20x60
20x20x60 20x20x65 20x20x65 20x24x65 20x24x65 20x24x70 24x24x70
20x20x60 20x20x65 20x20x70 20x24x70 24x24x70 24x24x75 24x24x75 28x28x75 26x28x80
Boiler Cleanser, Boiler Lea\ Seal
The Vinco Company, Inc.
75 Vesey Street, New York, N. Y.
Cable Address--VTncomp, New. York
Vinco for Internal Cleansing of New, Remodeled and Old Heating Systems
Vinco Superfine Boiler Leak Seal
What Vinco Is
Vinco (Latin. " I con quer"), a positively harm less insoluble powder cleanser for new. re
modeled and old heating systems.
What Vinco Does
Vinco permanently re moves all the oil. grease, scale and dirt from the internal surfaces and from the boiler water without the labor of blowing boilers over the top.
By this thorough cleansing Vinco stops foaming, priming, surging, incomplete circu lation and poor radiation.
The heating system is thus enabled to function in the best manner permitted by the design.
Cracked boiler sections, which most often result from priming, and sudden slugs of cooled water, are prevented.
How Vinco Works Each minute grain of Vinco powder absorbs several times its own weight of oil, rust and dirt. These larger grains of absorbed impurities then settle and are blown through the bottom, according to direc tions on each can.
Vinco for all New and Remodeled Systems
Gives the heating system a clean bill of health from the start and puts every well-engineered system into first class operating condition before turning over to the owner. Use these specifications:
Vinco Specifications for Steam and
Vapor Systems
Cleaning the System--Upon completion of the installation, the contractor shall clean the system by the Vinco method to remove oil, grease, rust and dirt from the boiler using,*-......lb. of Vinco. in exact accordance with manufacturer's directions.
This compound must remain in the boiler for 36 actual steaming hours, -which corresponds to six or seven days average operation. At the end of this period, boiler must be thoroughly drained and flushed before refilling with clean water.
*ln writing specification, insert in this space number of pounds of Vinco to be used in accordance
with the following schedule. For systems having:
Up 351 601
to *
350 600 1100
sa.aft. a
ouf
radiation
3 lb.
5a
* ____________ 8
1101 - 1400 1401 1800
* a
* a
*
10 " ........13 "
1801 * 2100 2101 * 2700 2701 * 3100
"
m
* *
. ,,15 *
. .18 . _20
3101 * 3700 "
... .23 "
3701 4200 4201 4600
"
* a
*
... ..26 * . ..28 "
4601 5000 " * . .
____ 30 *
Above 5000 sq. ft. use an additional pound of Vinco for each additional 300 sq. ft. of radiation.
In determining amount of Vinco to be used all radiation may be taken at actual rating.
Vinco Specifications for Hot Water Systems
Cleaning the System--Upon completion of the installation, the contractor shall clean the system by the Vinco method using **....... lb. of Vinco in exact accordance with manufacturer's special directions for hot water systems, given on their cans.
Only one half above quantities required for hot water systems.
Vinco for Old Systems Annual cleaning of the old heating system adds years of life to the boiler, prevents rust deteriora tion and saves much fuel and fire attendance.
For old systems use only one half quantities given in specifica tion table.
Our Free "Certified Chemically
Correct" Laboratory Service Vmco and the free services of the Vinco laboratories give you the assurance that the boiler water is chemically correct. Then if the trailer still foams, throws water or does not perform properly, it .is time to look for mechanical flaws.
We promptly diagnose and permanently correct water line troubles aue to impure water. Groping in thedark, guess work, needless piping changes and recriminations- are thus eliminated.
Our Three-fold Guarantee 1. Vinco contains no potash, lye, soda of any kind, oil, acid,
or other harmful ingredients. 2. Vinco meets every performance claim. Purchase price is
refunded if results are not entirely satisfactory when Vinco has been used according to directions. 3. Your time, money and comfort are further safeguarded by our free laboratory service which sees the most punling "water line" problem through with you if you wish.
Vinco Distributors Vinco is distributed nationally by Burnham Boiler Corpora tion, Crane Company, United States Radiator, National Radiator. It is sold through leading jobbers in the United States.
Patents are pending upon the product and method < application. Unlawful imitation will be prosecuted.
Vinco Superfine Liquid Boiler Seal
A new and better leak seal, evolved by the same original research and authoritative science responsible for Vinco Boiler Cleanser. It will give the same prompt, sure results. It makes speedy and permanent re pairs of all boiler and heat ing system leaks.
It is fine to tighten up new jobs. The directions are simple to follow.
QUANTITIES
Steam and Vapor Systems
Use 1 quart Vinco Liquid Boiler Seal to each 6 sq. ft. grate area.
Hot Water Systems
Use 2 quarts Vinco liquid Boiler Seal to each 6 sq. ft. grate area.
581
/