Document gEgvpeNVZOe71V1nkNM60mqkQ
B-Line Boiler Company
East 131st Street at Taft Avenue
Cleveland n ^
Manufacturers of Gas Boilers for Hot Water, Steam and *
Vapor Heating; Hot Water Generators; Accessories
B-Line Gas-Fired Boilers
BLine Gas-Fired Boilers are built for use in connection with Steam, Vapor or Hot Water systerns of heating; Industrial Steam Supply Units, and Volume Water Heating Units.
B-Line Boilers are constructed of cast-iron sections assembled with cast-iron push nipples.
W
Ijj
The heat absorbing surface is unusually large and arranged so as to transmit practically all available heat into the water.
B-Line Boiler control system is entirely auto matic in operation, or semi-automatic, if desired. The controls are mechanical, gas operated type, consisting of a hand control valve; gas pressure regulator; snap action fuel control valve to cut on or off, the ful supply at a predetermined steam pressure, or Water temperature; automatic secon dary air control which cuts off the air supply to the combustion chamber when the fire is extin guished, thus eliminating rapid cooling of the . boiler sections. Automatic low water fuel'cut-off is furnished for steam boilers. Thermostatic pilots
^" `*r '
'`
are optional. B-Line Boilers are all fitted with a metal jacketed coveringand heavy asbestos insula
tion. Careful consideration has been given to the means of removing the jacket for cleaning the boiler.
Specifications for B-Line Boilers approved by the American Gas Association follow:
RATINGS--DIMENSIONS
1
Inches |
Equiv. Diam,,
Opening
Floor Space Dimensions
Inches
Number and Size Tappings .
Flows
Returns
Flue Openings
ney
` A*
3'
4*
3'
No.
Diam. Inches
CsIs.PC.oSn.n.ection J
Boiiler Num ber A.G .A. Steam
R ating, Sq. F t. A.G.A. Water . Rating, Sq. Ft. O u tp u t
Btu per Hour Boiler
Horse Power Length W idth
him
C
1
32 410 650
97.920 2.9 30/2 44
2
2
1 6 61
43 610 980
146,880 4.4 34y, 44
2
2
l 6 6 1
54 820 1300
195,840. 5.8
40VS
44
2
2
1 7 7 1/4
65 1020 1630
244.800 7.3 44'/2
44
2
2
1 7 7 1%
76 1220 I960
293,760 8.8 4S'/2 44
2
2
2 6 8 l'/<
87 1430 2280
342.720 10.2
52'/2
44
2
2
2 6 8 I'/r
98 . 1630 2610 . 391.680 11.7
56'/,
44
2
2
2 7 8 I'h
109 1840 2940
440.640 13.2
64'A\ 45
2
2
2 7 9L
1110 2040 3260
489.600 14.6
68'/2
45
2
2
2 7 92
1211 2240 3590
538.560 16.1
ll'/i
45
2
2
3 7 10 2
1312 2450 3910
587.520 17.5
76'/z
45
2
1
2
1
3, 7
10 2
1413 2650 4240
636.480 19.0
80'/2
45
2
1
2
1
3
7 12 2
1514 2860 4570
685.440 20.4
841/2. 45
2
2
2
2
3
7 12 2
1615 3060 4890
734,400 21.9
88'/2 45
2
2
2
2
4
7 12 2
1716 3280 5220 : 783,360 23.4
45 2 2 2 2 4 7 12 2
1918 3670 5870
881.280 26.3 iooy.
45
2
2
2
2
4
7 14 2
2019 3880 6200
930,240 27.8 I04A
45
2, 3
2
3
4
7 14 2
2120 . 4080 6520
979,200 29.2 118'/2 .45
2
3
2
5 7 14 2Vi
2322 . 4490 7180 1,077.120 32.2 126/2. 45 2 3 2 3 5 7 14 i'h
2524 4900 7830 1.175,040 35.1 136'/$
45
2
3
2
3
5
7__ 1 16 i
2726 5300. 8480 1.272,960 38.0 144/2 . 45 2 3 2 3 6 7, 16 3
2928 5710 9130 1.370.880 40.9 l52'/2
45
2
3
2
3
6
7 16 3
3130 6120- 9790 1.468.800 43.9 I6C/2
45
2
4
2
4
6
7 18 3
3332 6530 10440 1,566.720 46.9 168/2
45
2
4
2
4
7
7 18 3
3534 6940 11090 1,664.640 49.7 176'/2
45
2
4
2
4
7
7 18 3
3736 7340 11740 1.762.560 52.7. 184/2
45 ' 2 5, 2
5
8
7 20
3938 7750 12400 1,860.480 55.7 192k
45
2
5
2
5
8
7 20
4140 8160 13050 1,958,400 58.5 200/2
45
2
5
2
5
8
7 20
Height of all boilers to top of draft hood--62 in., to top of covering--54 in.; to center of flow--48J4in.;to center of return-- in., to water line--40 in. Horizontal distance, center flow to center return--25 in. 3 in. return connections standard
on water boilers only. .
624
Boilers, Gas
L. J. Mueller Furnace Go.
Established 1857
338 So. Second St., Milwaukee, Wis.
Gas-Era Gas-Fired Boilers
Adaptable for steam or hot water heating. Completely automatic operation. Cast iron construction for dura bility, with asbestos-lined metallic jacket. Vertical burner adjustment permits use with any manufactured or natural gas. Have steady water line and will not prime. Interior surfaces may be thoroughly cleaned without disturbing jacket. Multiple unit construction permits increase in size when desired. Boiler is highly efficient, securing maximum heat utilization with minimum gas consumption.
Floor Space Inches
793/4* 533/8
87A* 535/B
95`A* 543/4
103 * 343/4
1103/4 * 56/e
120/2 *
128/4 x
5S3453//bJ
1M36V/**x 554433/A4
87/2*1071/4 95% x 109/,
103 x 109>A 1103/4* 1121/1
120/2* 107/4
128V* * 109/2 136 x 109/a
1433/4x 109/2
1__________ .______________
Gas-Era Gas-Fired Warm Air Furnace
Cast iron construction, with lacquered casing in attractive
color. Completely automatic, tamper-proof operation. Burns any gas, natural or manufactured. Accessible for cleaning. Ample free area. Automatic moisture supply. Adaptable for forced air heating on large jobs. Multiple unit construction.
oass
ans.Era Furnace