SOP#: 11 SOP TITLE: STEAM STRIPPER PHASE SEPARATOR
ORGANICS REMOVAL
H
iPERATOR: DATE:
written by: Claude A. Chaisson date: 4/8/89
reviewed by: CONTROL ROOM date: 01/01/92
H approved bv: Art Reinhardt M date: 02/18/92________________
CHECK ACTION STEPS AS THEY ARE COMPLETED 1 JOB SAFETY INSTRUCTIONS REVIEWED.
2 ENSURE THAT YOU ARE WEARING PROPER SAFETY EQUIPMENT.
3 MAKE SURE THAT THE PIPING TO THE INTERMEDIATE CRUDE TANK IS LINED UP PROPERLY.
k START-UP AN ORGANICS PUMP.
5 THE PUMP IS RUN UNTIL ALL ORGANICS ARE REMOVED, USUALLY UNTIL THE CATALYST PHASE SHOWS UP AT THE SUCTION BLEED.
6 THIS IS USUALLY PUMPED EVERY 4 HOURS OR MORE OFTEN IF NECESSARY.
7. THE LEVEL TRANSMITTER (L-906) WORKS POORLY, AND IT IS DIFFICULT TO FIND AN ORGANICS LEVEL IN THE S/G. SO IF THE SUCTION BLEED AT THE PUMP IS CHECKED, CATCH THE ORGANICS IN A CONTAINER TO AVOID GETTING ANY ON THE PAD OR IN THE TRENCHES WHICH GO TO THE BAT SUMP .
8. THE CONTAINER IS EMPTIED INTO AN ORGANICS COLLECTION DRUM AT
THE TETRA TANK.