Document gEEeNG7Bw8YKoagx6X4qpyZkV
852
CHAPTER 39
1951 Guide
horsepower ratings. The constant horsepower type of motor is consider ably larger than the constant torque motor, due to the fact that the same horsepower must be developed at either reduced speed or high speed.
In selecting two-speed motors for fan, pump, blower, or compressor applications, it is usually found that two winding motors are more expensive than the single winding type. The control cost for two-speed, two wind ing motors, however, is more economical, and therefore the combined price of both motor and control for the two winding motor is only slightly higher. Because of the improved performance of the two winding motors, and because of the factor of safety provided by two independent windings, the increased cost is frequently worth the difference.
Single Phase Motors
Single phase induction motors have auxiliary windings or devices for starting, and are classified by the method used.
Table 7. Typical Application Requirements of Synchronous Motor Drives Showing Starting, Pull-In and Pull-Out Torques
Application
Method or Connecting Moron
ro Load
Torques
Conditions Start Pull- Pulling in Out
Remarks
1 Exhaust and venti Coupled or belted Usually loaded SO 60-125 150 WR1 of fan must be
lating
considered
Cycloidal positive
e Blowing engines re
1 ciprocating
Coupled or engine type
Engine type
Unloaded Unloaded
40-60 40-60 150 Two-speed motors sometimes used
40 40-60 150
Turbo high speed - Direct connected or Unloaded (in- SO 50 150 WR* of blower must
step up gear
. take closed)
be considered
Air
Engine type
Unloaded
40 30 150 Flywheel effect im
i portant
1 Ammonia and am High speed--belted Unloaded (by 40 30 150 Flywheel effect im
monia booster.
Low speed--engine by-pass)
portant
type occasionally
coupled
ti 6 Freon
High speed--belted Unloaded (by 45 50 150 Flywheel effect im
Low speed--engine by-pass)
portant
Gas reciprocating High speed--belted Unloaded (by 40 Low speed--engine by-pass)
SO - 160 Flywheel effect im portant
Capacitor start motors develop high starting torque in fractional hp rat ings, and moderate starting torque in larger ratings. They are used' for. constant speed drive such as fans, blowers and centrifugal pumps. During the starting period, a winding with a capacitor in series is connected to the motor circuit and when the motor comes up to speed, a centrifugal switch cuts the capacitor and second winding out of the circuit.
Two-value capacitor motors develop high starting torque employing a starting capacitor and a running capacitor. The starting capacitor gives high starting ability, but is suited for short time operation only, and is cut out for the running condition by a centrifugal switch. The running ca pacitor gives high efficiency at full speed. These motors are used, on compressors, reciprocating pumps and similar equipment which may start under heavy load.
Permanent split capacitor motors have low starting torque and are ideally
Motors and Motor Controls
853
suited for small fan drives. Operation is similar to the capacitor start motor, except that the capacitor is not cut out when running.
Repulsion-Induction motors develop high starting torque. The motors have two rotor windings--a squirrel cage for running and a wound rotor connected to a commutator for starting. No switching device is required to change from starting to running winding as this is accomplished by a gradual shift with speed in the magnetic flux path, so that near rated speed the motor operates completely on the squirrel cage winding.
Repulsion Start-Induction Run motors are similar to the repulsioninduction motor, but they have only the commutator winding. They are supplied with a centrifugal short circuiting switch which shorts the com mutator bars when the motor comes up to speed to obtain a winding ap proximately like the squirrel cage in its function.
Fig. 10. Speed-Torque Characteristics of Single Phase Motors
Repulsion-Induction and Repulsion-Start-Induction Run motors are suit able for applications such as industrial compressors requiring high break away torque, and where commutator and brush noise are not factors.
Split Phase motors have a high resistance auxiliary winding which is
in the circuit during starting, but is disconnected through the action of a
centrifugal switch as the motor comes up to speed. Under running con
ditions it operates as a single phase induction motor with one winding in
the circuit. These units are available for the small horsepower ratings,
and when equipped with a high slip rotor may be used for adjustable
varying speeds through line voltage control. The motors are ideally
suited for fan duty.
-
Speed-torque characteristics of single phase motors are shown in Fig. 10.