Monsanto rue*-* 'N*vr * LOCATION* John VanderKooi - Research Laboratories - AKRON 1010 July 21, 1978 tc E. J. Young R. W. Wise PCB IN HEAT TRANSFER SYSTEM A. B. Sullivan R. L. Liss - B3NJ R. Liss to R. W. Wise - July 17 1978 G. D. Glasgow - 1250 Dayton J. Finch TO D. Wood St. Louis B2SD A fresh sample of Therminol (taken 7/20/78) has been sent to G. D. Glasgow. Previous assays of the PCB content reported levels of chlorine of 1.34 and 1.38% in February, 1974. In May, 1976, the chlorine level was reported to be 1.25% (or 3% Therminol FR-1). The assay reported in 1978 was 1.8% PCB. The total volume is 1500 gals, in the main system. In. addition, a 2500 gal. storage tank is underground. Currently, we have an estimated 285 gals, left in the storage tank and 100 gals, in a tower room tank. We have 60 gals, in metal drums and 1 drum of Therminol soaked oil sponge. There has been no new Therminol added to our system since the 1973 changeover. c jd J. VanderKooi PCB-ARCH-EXT0377837