Document gDg1xXpa1mXmK9orNx7zGXpaV
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION III
1600 John F Kennedy Boulevard Four Penn Center
Philadelphia, Pennsylvania 19103
Report Title: Inspection Date(s): Regulatory Program(s): Type of Activity: Facility Name: Permittee(s): Facility Operator: Facility Address: Lat/Long: County/Parish: Permit Number: NAICS & SIC Codes: Unique Project #:
Clean Water Act Compliance Inspection Report 08/25/2022 National Pollutant Discharge Elimination System (NPDES) Pretreatment Industrial User Inspection Pennex Aluminum Pennex Aluminum Pennex Aluminum 50 Community Street, Wellsville, PA 17365 40.0524, -76.93907 York PAP132000 423510/5051 3E22WN033A
Facility Representative(s):
Point of Contact
Nathan Foor Training Coordinator Pennex Aluminum
Phone: 717-432-9647
Email: NFoor@pennexaluminum.com
EPA Inspectors:
Aaron Thomson - EPA Inspector (3ED33)
Phone: 215-814-2116
Email: Thomson.aaron@epa.gov
Report Preparer Signature/Date
Supervisor Signature/Date
Aaron Thomson, Inspector
1600 John F. Kennedy Boulevard (3ED33)
Philadelphia, PA 19103
JESSICA
Digitally signed by JESSICA DUFFY
DUFFY
Date: 2023.06.06 07:48:21 -04'00'
Jessica Duffy, Acting NPDES 2 Section Chief 1600 John F. Kennedy Boulevard Philadelphia, PA 19103
Date Date
Pennex Aluminum Pretreatment Industrial User Inspection
08/25/2022
Table of Contents
I. Introduction ......................................................................................................................................................... 3 A. Inspection Opening Conference ............................................................................................................... 3 B. Weather and Precipitation Conditions...................................................................................................... 3
II. Facility Activity/Walkthrough ........................................................................................................................... 3 III. Observations ..................................................................................................................................................... 4 IV. Records Review .............................................................................................................................................. 10 V. Closing Conference.......................................................................................................................................... 10 VI. List of Attachments......................................................................................................................................... 10
Unique Project #: 3E22WN033A
Page 2 of 10
I. Introduction
Pennex Aluminum Pretreatment Industrial User Inspection
08/25/2022
On August 15, 2022, Aaron Thomson (hereinafter,
or the
) an inspector
Region III conducted an on-site inspection of the
Pennex Aluminum facility (hereinafter, Pennex , or facility pretreatment program. The facility is an
aluminum extrusion plant, which receives raw aluminum, melts it, casts it into logs and then extrudes it,
creating a finished product. The facility is located at 50 Community Street, Wellsville, PA 17365. The purpose
CWA ) and the
applicable Federal Pretreatment Regulations. The Pennsylvania Department of Environmental Protection
was invited to the inspection but chose not to attend. No controlling document or permit was
provided by the Facility as of writing this report.
A. Inspection Opening Conference The EPA Inspector arrived at the facility at approximately 11:00 AM for the on-site inspection. Inspector Thomson met with the following facility representatives:
Name
Aaron Thomson
Nathan Foor Gary Yeager
Table 1: Inspection Attendee List
Affiliation
Telephone
Email
EPA Region III Inspectors and Contractors
EPA - Philadelphia
215-814-2116
Thomson.aaron@epa.gov
Site/Facility Representatives
Pennex Aluminum
717-432-9647
NFoor@pennexaluminum.com
Pennex Aluminum
717-432-9647
None provided
Inspector Thomson displayed their credentials to Mr. Gary Yeager
, Maintenance
Manager at Pennex and Mr. Nathan Foor
Foor
at the
outset of the inspection, and explained the purpose of the inspection was to observe compliance with the Federal
Pretreatment Regulations. The EPA Inspector informed Mr. Yeager that any information that the Facility
inspection and it would be
B. Weather and Precipitation Conditions During the inspection, the weather was sunny with a high of 90 degrees Fahrenheit.
II. Facility Activity/Walkthrough The Pennex Aluminum facility is an aluminum casting and extrusion manufacturing plant. The facility receives raw aluminum scrap which are melted and cast into cylinders of aluminum which are then extruded. The
the POTW conveyance system includes backwash water generated from the water-cooling system process used on metal during the extrusion process, blowdown from non-contact cooling water, and sanitary wastewater. According to Mr. Yeager, the wastewater (backwash) generated during the extrusion process is collected in an equalization storage tank where it is monitored for pH, Oxygen-Reduction Potential (ORP) and conductivity. Backwash both leaving and entering the EQ tank is filtered to remove physical media. When the conductivity of the water in the EQ exceeds desirable process limits, the pH of the wastewater is measured with a probe to ensure it is still within permitted discharge limits, if necessary the pH is adjusted with neutralization, and then moved to a reservoir tank to be discharged to the POTW conveyance system. Mr. Yeager stated the probe is calibrated
Unique Project #: 3E22WN033A
Page 3 of 10
Pennex Aluminum Pretreatment Industrial User Inspection
08/25/2022
not been supplied by the Facility as of writing this report. Mr. Yeager stated that the water is discharged in batches, automatically, approximately once per day shift. According to Mr. Yeager, the facility calibrates pH, ORP and conductivity daily, and Guardian (no location/further information given) calibrates their systems monthly. Mr. Yeager stated that the monitoring system runs 24/7 and will notify their phones via email if any issues occur.
Inspector Thomson requested information or documents relating to the categorical industrial user status of the facility, as of writing this report and as of writing this report, the requested documents have not been provided by the Facility. A Categorical Industrial User (CIU) is subject to the Federal Pretreatment Regulations 40 CFR Part 403. Categorical Industrial User Regulations 40 CFR Part 433.15 details the pretreatment standards of an existing aluminium forming point source, extrusion subcategory. The facility discharges to the Wellsville publicly owned treatment works (POTW). Because the facility discharges into a POTW without an approved pretreatment program, EPA is designated as the Control Authority per 40 CFR Part 403.3(f), and as such is the authority for inspections under section 308 of the CWA.
After the opening conference, Mr. Yeager led a tour of the processes that contribute to the wastewater discharge
to the sewage system.
monitoring probe console (Attachment 1
Photographs 1 and 2). Next, Inspector Thomson was led to the filtration system, a tank with granular activated
carbon (GAC) filter media, (Attachment 1 Photographs 3 and 4), which was adjacent to the equalization tank
(Attachment 1 Photograph 5).
(Attachment 1 Photographs 6 and 7).
tank (reservoir tank holding post-
treatment wastewater)
point (Attachment 1 Photograph 8) and leads the
.
sampling station, where expired buffers were observed (Attachment 1 Photographs 9, 10 and 11). Finally,
ed wastewater (Attachment 1 Photograph 12) including a flow meter and shutoff valve. This concluded the site tour.
III. Observations A checklist was utilized during the review and is provided below. The checklist is divided into sections, with Observations listed under each section. Photographs were taken during the inspection by Inspector Aaron Thomson, and are provided in Attachment 1. Not all photographs taken during the inspection are included in this report.
Visual Observations pertaining to each section are listed at the end of each section.
Section 1. General Information
General Description of Processes and Products Are there any alternates to effluent monitoring conducted? (e.g., TTO/TOMP, Waiver requirements?) Describe in
Yes No N/A Comments aluminum casting/extrusion
No info provided
Unique Project #: 3E22WN033A
Page 4 of 10
Provide production rates for all processes subject to production based standards and include: 1) Process 2) production rate used for calculating limits 3) production rate for last 12 months Any anticipated changes in processes or production rates? List the production rate listed on the approval letter Shift information, list 1) Shift # 2) No. of Employees 3) Hours 4) Work Days Is production seasonal? If yes, describe List all visual observations pertaining to this section
Pennex Aluminum Pretreatment Industrial User Inspection
08/25/2022
No info provided
4 shifts/day runs 24/7, discharges approximately once per day shift
Section 2. Categorical Industry
Categorical Industry? Category(s): Subcategory(s): Regulatory New Source Date: New source? List of categorical processes List of other operations producing wastewater
List all visual observations pertaining to this section
Yes No N/A Comments No info from facility provided
40 CFR Part 433.15, Subpart A: Metal Finishing.
wastewater that is discharged) Rinse/wash
Information or documentation regarding categorical status was requested by Inspector Thomson at the time of the inspection and as of writing this report the Facility has supplied
no further documents or information
Section 3. Characterization of Wastewater Discharges (CFR 433.15)
Yes No N/A Comments
Describe the time of day discharge to sewer occurs Are discharges seasonal (if yes, describe)
Batch Discharge, once per day shift
Unique Project #: 3E22WN033A
Page 5 of 10
Pennex Aluminum Pretreatment Industrial User Inspection
08/25/2022
Attach a block flow diagram of manufacturing process in the Facility Activity section of the inspection report, including: chemical storage area, and wastewater generated. Identify all regulated, unregulated and dillution wastewater discharges. Include sample location, discharge flow rates and method of disposal*. Note any recent changes. *disposal method CD - Continuous discharge to sanitary ND - Not discharged or disposed BD - Batch discharge to sanitary sewer HH - Hauled as hazardous waste OD - Other disposal - not to sanitary sewer HW - Hauled as nonhazardous waste
List all visual observations pertaining to this section
Section 4. Pretreatment Facility
Pretreatment installed?
Briefly describe treatment processes and operation.
Describe sludge storage and disposal method Describe appearance of effluent at time of inspection. List all visual observations pertaining to this section
Yes No N/A Comments Consists of filtering physical media,
measuring/neutralizing pH Water is filtered through granular activated carbon. Filtered water is measured for pH,
conductivity and ORP and, if necessary, neutralized to bring pH with permitted parameters before being discharged to the
POTW n/a
n/a monitoring to verify that no further
treatment is necessary
Section 5.
Self Monitoring
Yes No N/A Comments
Does facility have a sampling plan or protocol including use of 40 C.F.R. Part 136 techniques (obtain copy)?
Not Provided
Is sampling location (identified on block flow diagram) the same as in control mechanism? If no, explain.
Not Provided
Is this sampling location permanently identified by a sign, painted number, or other means?
Is this sampling location shown on the chain of custody form?
Unique Project #: 3E22WN033A
Not Provided Page 6 of 10
Are any parameters monitored by approved methods more frequently than required at permitted sampling location?. If yes to previous question, are all results submitted to the control authority? Does facility resample and report within 30 days of discovering a violation? Are sampling records maintained on site? Describe for how long. Is flow determined as required by permit? How is flow determined (i.e., estimated or measured)? Is flow measurement appropriate?
Is flow measurement device calibrated?
Does the facility have an operator's manual for its pH meters? Does the facility do a proper 2-point calibration of its pH meter in accordance with the operator's manual?
Is other monitoring equipment (e.g. DO meter) calibrated? Describe how often if yes.
Is sampling and analysis done in-house or by contract? If by contract, list company. Is QA/QC program for sampling and analysis adequate? Obtain copy of plan if available. List all visual observations pertaining to this section
Pretreatment
Pennex Aluminum Industrial User Inspection
08/25/2022
Not Provided
Not Provided
Not Provided
Not Provided
Not Provided Measured continuously (meter)
Guardian (no info available) 1/month
Expired buffers Monthly by Guardian (no
info available)/daily calibration by facility
Not Provided
Not Provided Buffers observed were expired
Section 6.
Hazardous Waste Management
Yes No N/A Comments
Is IU aware of RCRA regulations?
Does facility generate any hazardous waste? If yes, indicate type of waste, method of management on site and means of disposal on a separate sheet. Describe any spillage problems or any other releases that are observed.
Inspector Thomson asked for description of process to remove/haul physical
media generated from filtration, no info provided
Has facility notified POTW and EPA of any hazardous waste discharges to the sewer?
List all visual observations pertaining to this section
Section 7. Spill Prevention
Yes No N/A Comments
Unique Project #: 3E22WN033A
Page 7 of 10
Has the facility had any spills or been responsible for slug loads? List dates of events in comments. If yes to previous question, was POTW notified? Does the facility have spill notification procedures posted? Has the facility evaluated its need for a spill prevention plan at least every two years?
If yes to previous question, was it determined that they needed one?
Does the IU have a spill prevention (SP) plan to address spills to the POTW?
If spills occurred- Did the IU follow procedures outlined in the spill plan at the time of spills?
If spills occurred- Were procedures effective in containing the spill?
Is the facility keeping records of spill events? Have there been any changes in spill procedures recently. Describe if yes. List all visual observations pertaining to this section
Pennex Aluminum Pretreatment Industrial User Inspection
08/25/2022 Facility not aware of any
spill/slug
Not Provided
Not Provided
Not Provided
Section 8.
Recordkeeping Review.
Yes No N/A Comments
Current IU control mechanism (through EPA, not a permit)
Not Provided
Notices and correspondence with control authority including:
a. Self monitoring report transmittals?
Not Provided
b. BMR if required?
Not Provided
c. Other?
Not Provided
Do sampling records include:
a. Date of sampling event?
Not Provided
b. Time of sampling event?
Not Provided
c. Name of sampling person and affiliation?
Not Provided
d. Sample collection method?
Not Provided
e. Method of sample preservation?
Not Provided
f. Description of sample location?
Not Provided
g. Name of person conduction analysis?
Not Provided
h. Date of analysis?
Not Provided
i. Time of analysis, if applicable (i.e., BOD, Cr?)
Not Provided
j. Sample analyses method?
Not Provided
Is type of sample specified in control mechanism?
Not Provided
Unique Project #: 3E22WN033A
Page 8 of 10
Are all parameters monitored at the required frequency? Note any discrepancies in comments. Analytical results? Are all monitoring results sent to the Control Authority? Are copies sent to the POTW? Appropriate production records for production based standards? Documentation of flow rates and volumes? Are records maintained at least 3 years? List all visual observations pertaining to this section
Pennex Aluminum Pretreatment Industrial User Inspection
08/25/2022
Not Provided
Not Provided Not Provided Not Provided
Not Provided
Not Provided Not Provided
Section 9. EPA Sampling
Were samples taken? Describe sampling location, method, and time: List all visual observations pertaining to this section
Yes No N/A Comments
Section 10. Stormwater
Does facility have a stormwater permit? If yes, describe what type of permit along with issuance and expiration dates Does facility have a stormwater pollution prevention plan? Describe any BMPs that the facility is currently implementing. List all visual observations pertaining to this section
Yes No N/A Comments
According to Mr. Yeager, no stormwater permit is necessary on site
Section 11. Current Compliance Status
Indicate compliance with: a. effluent limits (indicate in comments the date range reviewed) b. monitoring (indicate in comments the date range reviewed) c. recordkeeping/reporting (indicate in comments the date range and records reviewed) List all visual observations pertaining to this section
Yes No N/A Comments
Not Provided Not Provided Not Provided
Unique Project #: 3E22WN033A
Page 9 of 10
Pennex Aluminum Pretreatment Industrial User Inspection
08/25/2022 IV. Records Review As part of the inspection, prior to the inspection via teleconference and during the inspection, Inspector Thomson requested the following documentation be sent via email up to two weeks after the inspection: Control mechanism, 2 years worth of monitoring reports with chain of custody and sample results and slug/spill control plans (Attachment 1, Photograph 13). Additionally, during the inspection, Inspector Thomson asked for information relating to the categorical status, the removal and haulage of waste generated from the filtration system as well as process flow diagrams relating to the pretreatment. No information or documentation was provided by the facility as of writing this report.
V. Closing Conference After the facility inspection, the EPA Inspection Team met with the facility representatives for a closing conference. The EPA Inspection Team shared preliminary observations with the facility. The EPA Inspection Team reiterated to the facility representatives that all preliminary observations discussed were not compliance determinations. Any and all preliminary observations shared were subject to further investigation by EPA upon the additional review of records and documentation. Additional observations may be contained in this inspection report that were not identified at the time of the closing conference after EPA reviewed additional materials following the inspection.
The inspection concluded at 1:00 PM
VI. List of Attachments Attachment 1. Photo Log Attachment 2. Detailed Facility Report _ ECHO _ US EPA
Unique Project #: 3E22WN033A
Page 10 of 10