Document gDeMQa7jpEvZKrZ1Rd02yqq6G

TO E. L. Moore General Offices H. J. Horner G. A. Hippe D. L. Weber J. J. Zeman - G. 0. W. B. Papageorge - G.O. G. D. Nelson - G.O. The Krummrich Plant AR&D Group has completed their study of PCB's in Monsanto-manufactured ACL's and in purchased ACL's (FMC's CDB products). This was precipitated by an article published in the newspapers in October 1971 in which two University of Wisconsin researchers found PCB's in machine dishwashing compounds produced by Economics Labs (Electrosol and Finish). Since ACL and CDB are used as the disinfectants in these, they were suspect. The WGK ACL plant used PC3's (Pydraul A-200) principally in the hydraulic systems of the two Krupp centrifuges and the compactor. In late 1970, the decision was made to seek an acceptable substitute for Pydraul A-200 in ACL. The substitute found was Pydraul A-200-B (a terphenyl). The changeout was done as follows: . - South Centrifuge - February 1971 North Centrifuge - Early April 1071 Compactor - Early April 1971 The systems were not completely drained on changeout and a residual level of 1% to 5$ PCB was left in the system. Further changecuts and fluid loss replacement have diluted any PCB's in these systems to essentially zero. The results obtained by the WGK lab are as follows: Date Produced Grade Granulation Lot No. PCB Level (ppb)___ ACL 1970, March 1970, March ACL-59 ACL-59 R R KM-33 KM-60 78 '1 PCB (Pydraul A-200) Replaced with PCT (Pydraul A-200-3) IM-IO (fV 11-65 DSW 384782 STLCOPCB4101137 E. L. Moore PCB's in ACL Page 2 2/22/72 WGK 1 Date Produced ACL (cont'd.) Grade Granulation Lot No. PCB Level (ppb) - 1971, .May 6 1971, May 19 1971, July 21 1971, Aug. 6 1971, Dec. 27 1971, Dec. 27 1971, Dec. 30 acl-66 ACL-66 ACL-66 ACL-66 ACL-85 ACL-85 ACL-85 Crude CYA (ACL Raw Material) XG R R XG R XG R ' KA-4563 KA-312Q KA-3130 KA-4617 KA-5410 -- KA-5412 6l* 6 1 9 5 1 3 1972, Jan. 20 Crude CYA ' -- -- 2 FMC - CDB - FMC Lot 1971, Oct. 1971, Oct. 1971, Oct. acl-6o ACL-59 ACL-60 G 128482 Interference** XG 129601 Interference** XG 130307 Interference** *During the time this lot was produced;, two totes of old ACL-66 Powder (produced prior to Pydraul changeout) were being reworked thru*the compactor. This is the most probable reason PCB level is high, i.e. rework contained a high leYel of PCB which appeared in the new finished compacted product. *Analyses were made by an adaptation of the basic PCB method. In the three FMC samples, the plant was unable to determine if PCB's were present because the FMC samples contained substances that interfered with our method of detection. The test run by our lab is accurate down to 3 ppb. The "back ground" level of PCB's is in the 0-3 ppb range and can cause some problems in interpreting lower results. CONCLUSIONS ' 1. Since the change to Pydraul A-200-B, the PCB level in Monsanto ACL has dropped significantly and does not appear to be a problem. No further work is planned since Monsanto's ACL appears to be acceptable on PCB level. .. 2. FMC-produced ACL contains some substance (undetermined) which interferes with PCB determination -- we do not know if FMC-ACL contains PCB's or how much. pSVJ384783 STLCOPCB4101138 E. L. Moore PCB's in ACL Page 3 2/22/72 WGK CONCLUSIONS (Cont'd.) ' 3. The research people at Wisconsin may have been misled by this interference to believe that machine dishwashing compounds (with FMC-ACL) contained PCB's. q _ UL D. D. M^ckelson bp I I dS 3^84 STLCOPCB4101139