Document gDeMQa7jpEvZKrZ1Rd02yqq6G
TO E. L. Moore General Offices
H. J. Horner G. A. Hippe D. L. Weber J. J. Zeman - G. 0. W. B. Papageorge - G.O. G. D. Nelson - G.O.
The Krummrich Plant AR&D Group has completed their study of PCB's in Monsanto-manufactured ACL's and in purchased ACL's (FMC's CDB products). This was precipitated by an article published in the newspapers in October 1971 in which two University of Wisconsin researchers found PCB's in machine dishwashing compounds produced by Economics Labs (Electrosol and Finish). Since ACL and CDB are used as the disinfectants in these, they were suspect.
The WGK ACL plant used PC3's (Pydraul A-200) principally in the
hydraulic systems of the two Krupp centrifuges and the compactor.
In late 1970, the decision was made to seek an acceptable
substitute for Pydraul A-200 in ACL. The substitute found was
Pydraul A-200-B (a terphenyl). The changeout was done as
follows:
.
- South Centrifuge - February 1971
North Centrifuge - Early April 1071
Compactor
- Early April 1971
The systems were not completely drained on changeout and a
residual level of 1% to 5$ PCB was left in the system. Further
changecuts and fluid loss replacement have diluted any PCB's
in these systems to essentially zero.
The results obtained by the WGK lab are as follows:
Date Produced
Grade
Granulation Lot No.
PCB Level (ppb)___
ACL
1970, March 1970, March
ACL-59 ACL-59
R R
KM-33 KM-60
78 '1
PCB (Pydraul A-200) Replaced with PCT (Pydraul A-200-3)
IM-IO (fV 11-65
DSW 384782 STLCOPCB4101137
E. L. Moore PCB's in ACL
Page 2 2/22/72 WGK
1
Date Produced
ACL (cont'd.)
Grade
Granulation Lot No.
PCB Level (ppb) -
1971, .May 6 1971, May 19 1971, July 21 1971, Aug. 6
1971, Dec. 27
1971, Dec. 27 1971, Dec. 30
acl-66 ACL-66 ACL-66 ACL-66
ACL-85 ACL-85 ACL-85
Crude CYA (ACL Raw Material)
XG R R XG R XG R
'
KA-4563 KA-312Q KA-3130
KA-4617 KA-5410
--
KA-5412
6l* 6 1 9
5 1
3
1972, Jan. 20 Crude CYA '
--
--
2
FMC - CDB
- FMC Lot
1971, Oct. 1971, Oct. 1971, Oct.
acl-6o
ACL-59 ACL-60
G
128482
Interference**
XG
129601
Interference**
XG
130307
Interference**
*During the time this lot was produced;, two totes of old ACL-66 Powder (produced prior to Pydraul changeout) were being reworked thru*the compactor. This is the most probable reason PCB level is high, i.e. rework contained a high leYel of PCB which appeared in the new finished compacted product.
*Analyses were made by an adaptation of the basic PCB method. In the three FMC samples, the plant was unable to determine if PCB's were present because the FMC samples contained substances that interfered with our method of detection.
The test run by our lab is accurate down to 3 ppb. The "back ground" level of PCB's is in the 0-3 ppb range and can cause some problems in interpreting lower results.
CONCLUSIONS
'
1. Since the change to Pydraul A-200-B, the PCB level in Monsanto
ACL has dropped significantly and does not appear to be a
problem. No further work is planned since Monsanto's ACL
appears to be acceptable on PCB level.
..
2. FMC-produced ACL contains some substance (undetermined) which interferes with PCB determination -- we do not know if FMC-ACL contains PCB's or how much.
pSVJ384783
STLCOPCB4101138
E. L. Moore PCB's in ACL
Page 3
2/22/72 WGK
CONCLUSIONS (Cont'd.)
'
3. The research people at Wisconsin may have been misled by this interference to believe that machine dishwashing compounds (with FMC-ACL) contained PCB's.
q
_ UL
D. D. M^ckelson
bp
I
I
dS 3^84
STLCOPCB4101139