Document gDRrp8wE3JrZNRQoZLzKJovq3
S Monsanto
from (name ft location)
DATE
:
SUBJECT
:
REFERENCE
:
TO :
INDUSTRIAL CHEMICALS CO.
R. h. Mi 11 s, So. 2nd St., St. Louis, Mo.
December 3, 1971 Santicizer 790 - Mocan
L. 0. Raether LRAET .
tc: W. Farrar - Res 1 Vt~J . R. Darby - Res 1 - ' R. N. Brell - RBREL
R. W. Bucknell - RBUCK R. V. Johnson - RJOHN P. R. Graham - PGRAH J. A. Cannon - Res 3 A. W. Morgan - Res 3 N. W. Touchette - Res 3
You had asked for identification and analysis of Santicizer 790 from Mocan.
Samples were obtained from two drums in the warehouse.
These two samples had the same refractive index so
should be the same material. A GLC scan gave a
typical curve for this type of product. The samples
contained 0.2% alcohol and 0.3% other low boilers.
One sample was sent to the JFQ analytical lab and
the following analysis obtained.
-v
Appearance
Acidity, meq/lOOg.
Color, APHA
Moisture
.
Refractive Index
at 25
.
Specific Gr. at 25/25
S-790 Modah ' ' Specification
V.Slt. Opalescent
0.08
'''
20
0.08%
Clear,oily liquid 0.12 max. 50 max. 0.10% max.
1.4826
1.481-1.485
0.9770
0.973-.978
The S-790 met all specifications except for clarity. I could see no haze in the sample.
!
i
j ds
R. H. Mills
-
r
-v,,;.. .
<
`
. - -
...
DSW 587618
STLCOPCB4092954