I ' ` v/C--'t. r J The specimens shall then be maintained under1/standard conditions' for the period specified in 6.1.1 prior to removal of the mold. The flow test shall be conducted in a forced-draft oven maintained' at 200F, plus or minus 5F. At the completion of the 5-hour exposure period, if either specimen shows any flow or sag, as evidenced by dimension change of the specimen, the sealing compound shall have failed the test. 6.3.5 Non-Volatile Content Fill an aluminum container 2-3/16 in. in diameter and 1-3/8 in. ` in internal depth weighed to the nearest 0.01 gram, with 6 to 8 grams of freshly mixed sealant and immediately weigh the container with its content to the nearest 0.01 gram and place it uncovered in an oven at 200F + 5F for 24 hours. . Remove the sample from the oven and cool it to room temperature. Weigh the container with its content to the' nearest 0.01 gram and calculate the non-volatile content as follows: . .. where; B-C A-C 100 A is the weight of the container and sealant before heating, ' B is the weight of the container and sealant after heating, ' C is the weight of the container. 6.3 .6 \ .Weight Loss : ! Two polyethylene frames with inside dimensions of 1 1/2 inch | i in width, 4 inches in length and 1/4 inch in depth shall be . I ; placed on a 1/4 inch thick polyethylene board and overfilled i I . -with mixed sealant prepared as specified in 6.1.2. The excess J ; overfill shall be immediately struck off with a spatula. After : i two hours at standard conditions, remove the specimens from the i .frames and immediately place each specimen on a pre-weighed 3 inch ' I by 6 inch by 0.050 inch tin plated metal plate and obtain the weight of ' i the specimen to the nearest 0.01 g. After the specimens have conditioned 24 hours at standard conditions, the specimens and metal plates shall be placed in a forced draft oven maintained at 158F .+ 2F for 7 days. : After 7 days remove the specimens from the oven and condition at ' ! 'standard conditions for 4 hours. After conditioning 4 hours, weigh- : i the specimen and metal plate to the nearest 0.01 g. r' -5- .1 DSW 588435 STLCOPCB4093771