Document gDOqeNy4jkG5aKoqQbNkgJKxV

OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION ENVIRONMENTAL PROTECTION AGENCY Presentation on these agencies' requirements for the asbestos industry to Johns-Manvilie Asbestos Fiber Division Customers Presented By E. M. FENNER Director, Technical Relations Environmental Affairs Department . Johns-Manville Corporation December 3 and 4, 1973 CHEV BB 0002864 rr Tx xk?scrir OSHA asbeszcc p.~r.--.ci-r- z*.z *zandzrds for occupational exposure.- zo acbartcp.. SECOND - EPA eird.zsio.Ti sue*idards for asbestos. Both of these are cr vital importance to Jchns-Manville as a miner and miller cz asbestos fiber and a manufacturer of asbestos-containing products, and tc you,, our customers, who also manufacture products with asbestos. In discussing the OSHA standards, I will briefly review the five sections that I consider most important insofar as your operations are concerned, and recommend what changes I think industry should strive for when these standards are officially reopened by the Department of Labor. It presently appears that the Department of Labor will not form an Advisory Committee. Instead, within the next few months, they will publish in the Federal Register their proposed new asbestos standard, and request comment from all interested parties. This probably will be followed by a Public Hearing and the promulgation of the final revised standards. (Slide 2) CHEVBB 0002865 Tho five sections I'll disease cr; (1) Standards - The standard.1: airderne asbestos fiber in the workplan.-. (2) Monitoring - The method cl determining whether or not you meet tile fiber standards. (3) Methods of Compliance - The specified procedures. (4) Medical. (5) Labeling. Let's look at the fiber standards first. (Slide 3) Here they are. Presently, they call for a maximum of 5 fibers greater than 5 micrometers in length per cubic centimeter 8 hour time-weighted average concentration and 10 fibers greater than 5 micrometers in length per cubic centimeter ceiling concentration. Effective July 1, 1976, the time-weighted average concentration standard becomes 2 fibers greater than 5 micrometers in length per cubic centimeter. In all cases the standard is referring to all fibers greater than 5 micrometers in length that can be seen in the collected sample by phase contrast light microscopy at approximately 430X magnification. CHEV BB 0002866 -3- These and similar standards arc frequently referred to as Threshold Limit Values or TLVs. (Slide 4) This is the definition of a TLV. Threshold Limit Values refer to airborne concentrations of substances and represent conditions under which it is believed that nearly all workers may be repeatedly exposed, day after day, without adverse effect. What stand should industry take concerning the fiber standards during the review of the asbestos regulations? We should take the position that Bill Reitze just expressed that the level of 5 fibers per cubic centimeter is low enough to protect exposed employees against the biological effects of asbestos and that since 2 fibers per cubic centimeter will provide an added margin of safety, there is no need for a standard below 2. Now, how do you determine whether or not your workplaces meet the required standard? (Slide 5) By monitoring. You perform what is generally referred to as an Industrial Hygiene Survey. The asbestos standards require that CHEVBB 0002867 -4- (Slide 6) Within 6 months of publication of the regulations, every employer shall cause every place of employment where asbestos fibers are released to be monitored' in such a way as to determine where every employee1s exposure to asbestos fibers is below the prescribed limits. Monitoring is done by the membrane filter/personal air sampler technique. It requires that the employee wear an air sampler. (Slide 7) Here is one of our employees wearing the sampling device. A plastic holder containing a membrane filter is fastened to his collar in his breathing zone, open end down, so it samples the same air his nose breathes. Clipped to his belt is a battery powered vacuum pump connected to the filter holder with a rubber hose. The pump draws workplace air through the filter which collects the particulate and fibrous dust present in the air. (Slide 8) This is a close-up view of the equipment showing the pump, the filter holder and connecting hose. CHEV BB 0002868 with this -- because I think rhe present standard could be interpreted as requiring the monitoring of such operations. The standards should be modified to eliminate the requirement that the use of non-labeled fiber locked-in products be monitored. Next, (Slide 11) Methods of compliance. The asbestos standard very clearly defines these methods. I'll discuss only one -- engineering controls. (Slide 12) Engineering standards such as, but not limited to, isolation, enclosure, exhaust ventilation and dust collection shall be used. This is a very sound and very logical requirement that should be followed with any dust generating process or material, regardless of whether or not it contains fiber. Why? Because any dust in sufficient quantities is potentially hazardous. If you are looking for help in designing dust control systems ^ there are two very good publications: The one mentioned on the slide, which is prepared by the and American National Standards Institute - ANSI Z9.2-1971 this book INDUSTRIAL VENTILATION by the American Conference of EV BB 2870 -7- ir's OSHA's intention to greatly expand the methods of compliance section in the revised standards. Why, because they have encountered difficulty with monitoring. Apparently they don't intend to eliminate monitoring, but instead place it in a subordinate role to be used as a check upon the effectiveness of the application of their written methods of compliance which they now refer to as "Standards of Performance". I understand that OSHA presently plans to write these standards of performance for all facets of the asbestos using industry. That will be a tremendous job. Next subject. (Slide 13) Medical. The standard requires that (Slide 14) "The employer shall provide initial and annual comprehensive medical examinations to each of his employees engaged in occupations exposed to airborne concentrations of asbestos fiber." 5 There is no doubt that medical examinations are a necessity for employees exposed to significant quantities of asbestos fiber. However, during the standards review, our industry should recommend a modification. CHEV BB 0002871 The phrase "exposed to airborne concentrations of asbestos fibers" is the key to this medical requirement. NTOSH - National Institute for Occupational Safety and Health -- recommended in their criteria for occupational exposure to asbestos that for the purpose of medical surveillance -- (Slide 15} "The term exposed to asbestos will be interpreted as referring to time-weighted average exposures above 1 F/cc or peak exposures above 5 fibers per cc." The intent of this NIOSH recommendation was to eliminate the requirement for medical examination when an employee's exposure was below 1/2 the TLV. Inclusion .of this thinking into the revised standard would satisfactorily and logically limit the medical surveillance requirements. Now, (Slide 16) Labeling. The standards presently require that: (Slide 17) CHEV BB 0002872 "Caution labels shall be affixed to all products containing asbestos fibers, or to their containers, except that no label is required where asbestos fibers have been modified by a bonding agent, coating, binder or other material so that during any reasonably foreseeable use, no airborne concentrations of asbestos fibers in excess_ of the prescribed exposure limits will be released." The required wording of the label is:- (Slide 18) "Caution contains asbestos fibers avoid creating dust Breathing asbestos dust may cause serious bodily harm" Now, what is my point concerning labeling? In the forthcoming OSHA review proceedings industry should strongly take the stand that this labeling requirement need not be modified, since in its present form it provides all the protection necessary for the purchaser and user of asbestos containing products. This will prevent labels from being applied to such materials as cans of automobile underbody coating, rolls of asbestos roofing CHEV BB 0002873 10 cartons of vinyl asbestos ti 3 <=* and the wrappings of flooring roll goods. This also will prevent the label wording from being changed to include such words as "cancer producing*. I believe we have an excellent chance of achieving this goal, since we have much data to support our claim that significant quantities of fiber - from a health standpoint - are not released during "any reasonably foreseeable use" from the non-labelled products in which the fibers axe firmly "locked-inH. (Slide 19) Now - EPA. The Environmental Protection Agency published in the Federal Register of April 6r 1973, National Emission Standards for three hazardous air pollutants -- asbestos, beryllium and mercury,. The standards for asbestos are unique because there are no emission standards or nulnbers -- instead the regulations are written around (Slide 20) "No visible emissions" Such emissions are defined as any emissions which are visually detectable without the aid of instruments and which contain particulate asbestos material. An asbestos using mamifacturing operation that has no visible emissions is automatically in CHEVBB ftnn?R74 -il compliance* If am asbestos using plant has visible emissions but these emissions do not contain asbestos particulate as determined by microscopic examination of am emission sample, the operations is also in compliance. If a manufacturing operation does have asbestos containing visible emissions, then control devices must be installed and the standard requires that (Slide 21) a fabric bag filter be used in all cases except where the character of the emissions would render such a filter unsuitable, in which case (Slide 22) a high energy wet scrubber must be used. (Slide 23) There are. several notable deliberate exceptions from coverage under these standards. One of the most important is field fabrication. Field fabrication of any asbestos containing product is not subject to these standards. EPA's rationale for this is that if the field fabricating operation conforms to OSHA asbestos standards, potential airborne emissions will be satisfactorily controlled. CHEV BB 0002875 /_> -12I'm sure you have questions on these two subjects. As Jack Solon requested -- please hold them until the end of our formal presentation. Now. Noel Hendry -- fiber handling systems. CHEV Bji 0002876