Document gDGX4QvE9ZYk35022ykyzg93Q

Grinding the shoe using the No. 8050 Universal Brake Shoe Clamp shown in Figure 15 is similar to the proce dure for using the No. 8250 Fixed Anchor Clamp. Rotate the Handle clockwise 1/8 turn at a time, mov ing the Handle from side to side un til the entire surface of the shoe has been reconditioned by the Abrasive Belt Periodically check the calibration of the Model 890 Brake Shoe Grinder. Refer to Figure 16. To do this: 1. Unlock the Slide. Set it at the 6" setting. 2. Set Micrometer Dial at zero. 3. Put the No. 9632 Calibration Pin through the hole in the Slide. (The Pin is 3/16" in diameter.) 4. Turn the Dial gently back and forth until the Pin drops through under slight pressure. 5. At this point the Dial shouldread zero, and the calibration is correct. Figure IS -- Grinding a brake (ho with the No. 8050 Universal Brake Shoe Clamp IF A CORRECTION IS REQUIREO 1. ' Lock the Slide with the No. 9632 Calibration Pin in place. 2. Loosen both set screws in the Micrometer Dial until the Dial is free. 3. Turn the Micrometer Oial to zero. Use a screwdriver to hold the Micrometer Screw forward against the Slide Key and tighten both Dial Set Flflu/i 16 -- Inortiftf No. 9632 Calf* bration Pin to check calibration .of Modal 890 Shoe Grinder Screws evenly. Study this manual carefully until 4. Release the Slide Lock. Re you are thoroughly familiar with move the Calibration Pin and recheck the dial reading. the procedure lor grinding brake shoes. mmco ammo tools, me. 2m cimmimuin mum mm mum. iwmis com 8 A-4.Z-A-7I PR1NTEO IN U.S.A. NOVO 11002 4