Document gDDQNQq9pE2MM29kDg8MjBY53

Boilers Utica Heater Company UTICA, New York . 1R43 Grand Central Term'l 365 E. Illinois St. Chicago. III. . ^ ___ Representatives In Principal Jobbing Centers New VoEK' N' Y' Utica-Imperial SUPER-SMOKELESS Boilers Burn Soft Coal Smokelessly--Use Any Available Fuel Patented January 10, 19St. Utica-Imperial SUPER-SMOKELESS Boiler Cut-away View. Shawini Priautr, an* Salary CoaAusticn Chambers and A., /-Ids SUPER-SMOKELESS BOILERS Are designed to operate smokelessly when burning soft coal. They utilize any avail able fuel, burning either hard coal, solt coal, lignite, coke, fuel oil or gas with ex ceptional efficiency and decided economy. elimination of smoke-- Is attained by consuming the smoke and soot within the boiler. This complete combustion is due to the admission ol highly heated air through water-jacketed inlets, in the baffle wall at the rear of the fire box. The admixture of oxygen at this point instantly converts the heavy gases into incandescent flames of unusual heat ing capacity. The smoke and soot are actually used as fuel and clean chimney and flues are maintained at all times. SUPER-SMOKELESS Boilers comply with the most rigid smoke ordinances and are recommended by foremost heating engineers and leading architects for impor tant buildings. CONSTRUCTION-- SUPER-SMOKELESS Boilers have a single grate and are of sectional cast iron construction. Cast iron is highly resistant to corrosion and preferable to steel where low pressure permits using it. The sectional construction permits easy handling in shipment as well as installation m com pleted buildings. The baffle wall is a specially designed water section of the boiler It has a series of water-jacketed air inlets above the firebed and is covered on the side facing the fire by high-test plastic firebrick. OPERATION-- SUPER-SMOKELESS Boilers are ex tremely simple to operate. No special skill or high priced help is required. Long firing periods are the rule and little care or attention is required for successful, smokeless operation. 348 Utica Heater Company Boilers Capacities and Dimensions of Utica-Imperial SUPER-SMOKELESS Boilers Number Steam Ratings Sq. Ft. Number Water Ratings Sq. Ft. Grate Area Sq. Ft. No. and Size of Outlets (Inches) Diameter of Smoke Collar (Inches) Length of Smoke Box (Inches) Length of Sections (Inches) Length of Sections and Smoke Box (Inches) S-245 S-246 S-247 S-248 S-249 $-335 S-336 S-337 S-338 S-339 S-3310 S-405 S-406 S-407 S-408 S-409 S-4010 S--4011 S--4012 S-4013 S-4014 S-4015 S-4016 S--4017 S-4018 S-4019 S-4020 S-4021 S-4022 S-4023 S-4024 1200 1500 1800 2100 2400 2000 2500 3000 3500 4000 4700 2750 3500 4250 5000 5750 6500 7250 8000 8750 9500 10250 11000 11750 12500 13250 14000 14750 15500 16250 17000 W-245 W-246 W-247 W-248 W-249 1920 2400 2880 3360 3840 W-335 W-336 W-337 W-338 W-339 W-3310 3200 4000 4800 5600 6400 7520 W-405 4400 W-406 5600 W-407 6800 W-408 8000 W-409 9200 W-4010 10400 W-40II 11600 W-4012 12800 W-4013 14000 W-4014 15200 W^40I5 - 16400 W-4016 17600 W-4017 18800 W-4018 20000 W-4019 21200 W-4020 22400 W-4021 23600 W-4022 24800 W-4023 26000 W-4024 27200 4:96 6.16 6! 16 7.36 7.36 1-4 2-4 2-4 2-4 3-4 7.32 1-5 9.10 2-5 10.87 2-5 12.65 . 2-5 14.42 3-5 16.20 3-5 9.68 12.03 14.38 16.73 19.08 21.43 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 1-5 2-5 2-5 3-5 3-5 3-5 3-5 4-5 4-5 4-5 4-5 4-5 4-5 4-5 5-5 5-5 5-5 5-5 5-5 5-5 12 21% 37% 59 12 21% 45/, 67% 14 20 53% 73% 14 20 62 82 14 20 70% 90% 15 23 37% 60% 15 23 45/, 68/, 15 . 23 53% 76% 16 21% 62 83/, 16 21% 70% 91% 16 21% 78% 100 18 27/2 37% 64% 18 27'/2 45/, 73 16 27/, 53% 81% . 18 2$ 62 89% 18 27/z 70% .97% 18 27/2 78/, 106 20 26 86% M2% 20 26 95 121 20 26 103% 129% 20 26 II1/2 137/, 20 26 119% 1453% 20 26 128 154 20 26 136% 162% 20 26 144% 170% 20 26 152% 1783% 20 26 161 187 20 26 169% 195% 20 26 177% 203% 20 26 185% 211% 20 26 194 220 Capacities and Dimensions of Utica-Duplex SUPER-SMOKELESS Boilers Number Steam Ratings Sq. Ft. Number Water Ratings Sq. Fl Grate Area Sq. Ft, . No. and Size of Outlets (inches) Diameter of Smoke Collar (Inches) Length of Smoke Box (Inches) Length of Sections (inches) Length of Sections and Smoke Box (Inches) S-827 8500-- W-827 1360) 28.76 8 28 17 53% 70% S-828 -10000 W-828 16000 28.76 8 28 17 62 79 S-829 11500 W-829 18400 33.46 8 28 17 70% 87% S-8210 13000 W-8210 20800 33.46 8 28 17 78/, 95% S-82II 14500 W-8211 23200 38.16 8 28 17 863% 103% S--8212 16000 W-8212 25600 38.16 8 28 17 95 112 S--8213 17500 W-8213 28000 42.86 8 28 17 103% 120% S-8214 19000 W-8214 30400 42.86 8 28 17 111/2 128% S--8215 20500 W-8215 32800 42.86 8 28 17 119% 136% $-8216 22000 W-8216 35200 47.54 8 28 17 128 145 S-8217 23500 W-8217 37600 47.54 8 28 17 136% 153% - S--8218 25000 W-8218 40000 47.54 8 28 17 144% 161% 'Height of water line: 24 series. 45H inches; 33 series. 53 inches; 40 series. 57 inches; 82 series, 57 inches. Equipment Shipped with Boilers' All Super-Smokeless Boilers are provided with equipment of the best type. Steam. Boilers are equipped with Water Column with gauge glass and compression cocks; Retard Steam Gauge with Bourdon brass tube spring, Non-Glare Dial, syphon and cock; All-brass Pop Safety Valve, A. S. M. E. Standard; and Automatic All-metal Damper Regulator suitable for low pressure. Every boiler is furnished with a complete set of firing tools, consisting of shaker handle, hook, hoe, slice bar and flue brush with handle. Duplex Steam Boilers are equipped with Steam Header, Return Yoke, and Equalizer fitted with Hartford Connection which may be used or not, as desired. y 349