Document gDD9Rd2QZ4j8J6EB8pr55m0oJ

General Sales Department ^ American ^ ^tandapd Radiator ^ ^aititapj CORPORATION February 24, 1950 GSD-22422-TJS PLAINTIFF'S EXHIBIT ,:P\p. O. Box 1226 Pittsburgh 30. P*. C'v- Mr. Lincoln Pierce, Manager BOSTON SALES OFFICE Mr. W. F. Johnson, Manager NEWARK SALES OFFICE Mr. D. J. Keefe, Manager NEW YORK SALES OFFICE Mr. W. T. Reed, Manager PHILADELPHIA SALES OFFICE c/c Mr. L. A. Kelly, D.S.M. New York Sales Office Mr. H. H. Steck, D.S.M. Washington Sales Office This is to announce the availability of the No. 704 Biltin Taco Tank Type Water Heater of 65 gallon capacity for use with the No. W-0-351-B Arcoflame Oil Heating Unit and the No. W-O-351 Boiler, details of which were given you in our letter of January 20, 1950, reference GSD-12015-SJS. This heater, like the No. 601 Biltin Taco Tankless Heater for this boiler, is of the trombone type and has a 4" header for installa tion in the back section. When ordered for use with the W-O-351 Boiler, the No. 704 Heater vdll be invoiced at $15.80 Trade Price extra. Whei the No. 704 Tank Type Heater is desired instead of the No. 601 Tankless Type presently shown with the No. W-O-351-3 Arcoflame Oil Heating Unit, order should so specify, and a deduction of $4*20 will be made from the Trade Price of $265.40 for the Oil Heating Unit for this sub stitution. apply, Regular Wholesalers' Discounts, Terms and Freight Conditions Descriptive literature, Form No. 856, giving ratings, dimen sional information and other data for both the W-0-351-B and W-O-351 is enclosed for your information. Additional quantities may be obtained from the Advertising Department by listing requirements on Requisition Form ARSS-35. lours very truly. 20333 Jos. Salamone, Manager General Sales Department _Now BETTER HEATING at LOWER COST FOR SMALLER HOMES--with the AMERiCAN-c$tai?dat*d W-O-351-B OIL FIRED BOILER-BURNER UNIT a small, quality built cast iron boiler--complete with big boiler features carefree, automatic oil fired heating for hot water systems 9 The perfect choice for those who plan to use oil for heating smaller homes, this American-Standard boil er-burner unit offers all the advan tages of carefree, completely auto matic heat. Designed exclusively for oil firing and built for installation in all types of hot water heating systems, it is a superior unit that will provide an abundance of comforting warmth through years of dependable service. Versatile and compact, this unit can be installed in any basement or first floor location, in basementless houses and similar buildings. Its wet base construction features waterways that extend completely under the combus tion chamber, providing cooler floors under the boiler, accelerated water circulation, and additional heating surface for greater efficiency. Its trim, colorful jacket, distinctive in the new Forge Red finish just perfected by American-Standard, is smooth, easy to keep clean, and harmonizes with modern surroundings. African First in heating ... first in plumbing 20334 (OSH ' A ie n iq a -I) HERE'S A DURABLE CAST IRON BOILER-BURNER UNIT FOR HOT WATER INSTALLATIONS The Automatic Oil Fired American-Standard W-O-351-B Boiler-Burner Unit More heat, quicker heat, comforting radiant heat, dependable automatic heat, lower cost heat--all are assured when the W-O-351-B is installed. For the advanced design of this quality built wet base boiler--matched with the famous Arcoflame Oil Burner-- provides a combination that is hard to beat in appearance, performance and durability. This unit is tried and proven--built to give years of dollar-saving heating comfort and trouble-free service plus the convenience of an automatic domestic hot water supr' A special Biltin Taco Tank or Tankless Type Water Heater provides hot water the y 'round. This outstanding boiler is also sold for use with any standard burner--the boilc onlv is designated W-O-351. Ask your Heating Contractor for details about the Ameri can-Standard time payment plan that makes modernization easy. THESE CONSTRUCTION FEATURES ASSURE A LIFETIME OF SATISFACTION Biltin TACO Water Heater -- provides \ear round domestic lux water automatically. Tank or Tankless T\pe, both specially designed for this boiler for installation through back saiuiii. Special Tankless Tvpc, illustrated, nukes use ol new extruded imeural finned tube surfaces m earn urcater heat transfer in coil. Kssures maximum etfuicno and ample supply nf hot water. Included, at rio extra cost, with W-0-5SI-B: optional equipment, at slight ad ditional cost, with W-O -551. Boiler Sections--made of durable cast iron, the one metal that has proven best user the sears for use in heating equipment. Sections are factory assembled and shipped reads to inMali. Joints between sections are machine around to assure a tight, close fit. Doors--constructed of heaw cast iron, with cast iron heat protecting bailie lininus to pre sent warping and heat loss. Precision tilted to eliminate mlilcration of air. Two-Pass Flues--oiler maximum heat ab sorbing surface. Multi-finned water tube sur faces extract extra heat units from hot gases. Observation Port -- permits observing oil dame when desired without disturbing combus tion or dame characteristics. Swing cover re mains in place, closed, unless port is in use. Arcotlame Oil Burner--assures peak per formance: a quality burner that complies with commercial standards. CS-75. Provides the best in oil heating and maximum boiler output. Model M, pedestal tvpc, Arcoflame recommend ed; boiler available without burner. RATINGS and DATA HOT WATER ONLY Water Content--relatively small amount of water to heat in waterways, permits more rapid heat transfer and quicker pick-up. Combustion Space--designed to burn oil efficiently and without waste: sciemificallv pro portioned with correct area of effective heating surface to assure maximum heat from fuel burned. Crown sheet baffle is furnished. Combustion Chamber--permits using heat ing surface of the boiler to best advantage: eliminates danger of breakage during shippir or handling. Heat Lib-O-Rator high tempet ture steel combustion chamber especially adapt ed to (bis boiler is installed at the factors. Jacket--harmonizes with surroundings in vir tually any location. Smartly stvJed. in attractive new Forge Red finish. Smooth, casv to keen clean surface. All parts are die cut and form* easily assembled. Modern and distinctive. Burner Plate -- made of rigid steel with heavy HA-inch insulation securely fastened in angle channels. Effective seal assures gas and air tight construction. Made with H/v-inch burner tube hole to ftt the Arcoflame: has 5Cl inch concentric knockout ring to accommodate burners with various sized tubes. Wet Base Construction -- waterway tend underneath combustion chamber, pros ing extra heating surface and increased effi ciency. Keeps floor cooler, safer for first floor or basementless house installations. Controls--provide safe, positive operation. The controls furnished are the finest available; combine to maintain the desired room tempera ture. uniformlv and dcpendjbh. throughout the heating season. Model N'umber InvuJIed K idi.ii ion M| k. toms Output MBH Size ot ( himnev Nozzle - C.li. , -Size 1 icight pvr hr. | ( nthes) lfeet) V, -0-351-B* W O- 551 :o 120 I :5 1 H x 8 1 ()' H x 8 20 20 hoilcr-Berncr l.'nd. /rnJudes Mit'lcl M Artollame Oil Burner < pedestal tvpeJ; Biltin lam Water Heater: md factors installed Heat Lib-O-R nor high temperiturt* steel combustion chamber. :see icjndard Jiquip.nent. Boiler onlv. ,css Arcullame Oil Burner and jrrjnged tor but less biltin Tjcu Water Heater. Firing Kate. CJlIons per hour. When turtmhed less Arcofiamc Oil Burner, it is recommended that boiler he fired at the specified firing rate and with an oil burner that complies w oh commercial standards (,S-"5, Location ttjpp/ng) H n F Cj (inches) (.ontrol Application * , 1 W jtcr Limit (.ontrol 11 , , 1 or Relief Valve Water Reverse Acting Low Limit (.ontrol. Tankless Tvnc Heater ` Operating Temperature Control. Tjnk Tvnc Heater t Water Heater , (Operating Temper.pure (.ontrol. 1 j Tankless Tvpc He _r Onlv STANDARD EQUIPMENT The W-O-351-B Boiler-Burner Uni standard equipment includes; W -0-551 Wi't Base Oil Boiler with Hush Jacket Model M Arcuflame Oil Burner (pedestal-type) with Detroit No. CA-701 buck Control No. H Arcotlame (.ontrol Set (Detroit No. CA-655 Immersion Limit Control. No. -U1-CH ''Timed Cy cling" Thermostat l and nozzle. Additional controls, it desired, arc also available at slight extra cor-t. No. 601 Biltin Taco Tankless Type (180-gal. cap x or No. 70-f Tank Type Ui5-g.il. capacity) Heater Heat Lib-O-Hator high temperature steel combustion chamber Draft Stabilizer Standard equipment tor (he boiler onlv includes: W-O-*51 West Base Oil Boiler with Flush Jacket, and Heat Lib-O-Rator high temperature steel com bustion chamber. Complies with A.Si.M.E. Standards Arcoflame Oil Burner Listed by Underwriters' Laboratories Form No HEATING AND PLUMBING 30--25M--2 50--116,H 20335 American Standard &Radiator ^amtarn PITTSBURGH >0. PA. AMERiCAN-<$tandard products including the W-0-351-B boiler-burnei unit, are all built to the same uni formly high quality and backed by the technical experience and manufactur ing skill of the American Radiator & Standard Sanitarv Corporation, a name synonvmous with health and comfort. Primed in U.S.A.