Document gD7nvZoQBaBy7bzypGK6pKqLQ

118 CHAPTER 6 : v- :' -hi 1948 GuiAi (k)Table 2. Conductivities and Conductances (C)'of Building and Insulating Materials--Concluded C'o--najut'U.m.tus (k) are pwerjwtnc!h?7* j/cr thickness (ian*ncduIyrti)t_W_<_*u__a_o__n_cf_oe_oj l()Q(Faahnr.e/bnrhethiticdkengersees temperature difference) or construction stated! not per inch thickness. Material', Description CoNDUcrrvm Dsxsnrl MEAN] on - (Lbpbb Co Ft) Temp ('Fahb Deq^ CoNDUCTANCB (*) XO INSULATING MATERIALS --Continued> >' Insulatcnq Bo, 7--Continued Made from licorice rooi_ 34 in. inflating birds'without special 16.1 finish/ (eleven samples).^_______ 1 in. Insulating board0... 165 to 215 135 Loom Fill Ttme , Made from ceiba fibers.. Made from ceiba fibers............ .................... Fibrous material made -from dolomite and silica. fibrous material made from slag... Redwood barlr Redwood hark.. Glass wool fibers 0.0003 in. to O.obo in. in diameter. Granular insulation node from combined silicate of lime and alumina. Expanded vermiculite......... ........................ Expanded, vermiculite, particle size-- 3 + 14 Regranslated cork about % in. particles Hand applied granular mineral wod 2 in. to 6 in. thick; horizontal position*. No covering. 4 in. machine blown granular mineral ' wool, horizontal position6. No covering Rock wool......... ......................... 1.90 1.60 150 9.40 3.00 5.00 150 6.2 8.10 6.05 *- to r.i3 5.74 10.0 Szjlb Insdlationb.._ . 1 Corkboard, no added binder,, Corkboard, no added binder... Corkboard, no added binder... Corkboard, no added binder,.. Corkboard.. Corkboard, asphaltic binder... Chemically treated hog hair with fflm~rf asphalt. Sugar cane fiber insulation blocks en . cased in asphalt membrane. Made from 85 per cent nnd 15 per cent asbestos..' Made from shredded Wood and i*mPTyfc ' Made from shredded wood and cement_ 14.0 10.6 7.0 5.4 -8.7 145 10.0 195 245 90 90 90 90 90 75 70 -86 '73 054 053 to 0.40 054 053 054 057 057 051 056 057 054 .0.48 052 051 050* to 053 050 0.27 054 050 057 ' 055 059 052 058 050 051 0.46 0.77 Resibtakcb Per Inch- . For Thickness] Thickness Listed (I) a) 3.03 to 250 2.94 4.35 4.17 3.70 3.70 3.22 3.84 3.70 4.17 2.08 3.12 352 ' 353 to 3.03 353 3.70 2.94 353 3.70 4.00 3.45 3.12 357 1.96 2.17 1.30 (3) (3) (3) (1) (1) (3) (3) (3) (1) ((13)) (4) ((11)) ((11)). 4) (1) (3) (3) (1> (3) (4) See notes on Pass 115. 1 Surface Conductance The surface conductance of a wall is the combined heat transfer to or . : from'the jvaU by radiation, convection and conduction. Each of the : threei portions making up the total may vary independently of the others, ; thus iaffecting the total conductance. The heat transfer by radiation ; between two surfaces is controlled by the character of the surfaces : (emissivity), the. temperature difference between them, and the solid . angle through which they see each other. The heat transfer by convection ' and conduction; is controlled by the roughness of the surface, by air movement arid temperature difference between the air and the surface. ' The importance of the effect of temperature of surrounding surfaces on the surface conductance due to the effect on radiation is illustrated in- Authority Heat Transmission Coefficients of Building Materials 119 Table 3, which applies to a vertical surface at 80 F, with ambient air at .70 F and effective emissivity equal to 0.83l. In many cases, because the heat resistance of the internal parts of the wall is high compared with the surface resistance, the surface factors are of minor importance. In other cases, e.g. single glass' windows, the surface resistances constitute almost the entire resistance and are there fore very, important. In a building heated by convection there is only a slight difference between- the temperatures of the interior wall surface and the surroundings, but if the building is heated by radiant panels there . may be a considerable difference *. (See also Chapter 31.) The convection part of the surface conductance coefficient is affected markedly by air movement. This is illustrated by Fig. 3, which shows the surface conductances for different materials at a mean temperature of 20 F and for wind velocities up to 40 mph. These include the radiation portion of the coefficient, which for ordinary building materials under these conditions would be constant at about 0.7 Btu. Table 3. Variation in Surface Conductance Coefficient with Different Temperatures of Surrounding Surface Subrounding Surface Temperature 75 K Convection--Btu per (hr) (sq ft)___ Radiation--Btu per (hr) (sq ft)____ Total--Btu per (hr) (sq ft)------------ 6.6 '4.4 11.0 70 F 6.6 8.6 15.2 69 F 6.6 9.6 16.2 60 F 6.6 17.0 23.6 50 F 6.6 24.9 31,5 Due to these variations for different conditions the selection of surface conductance coefficients for a practical building becomes a matter of judgment. In calculating the over-all heat transmission coefficients for the walls, etc. of Tables 5 to 18, 1.65 has been selected as an average inside surface conductance and 6.0 as an average outside surface conductance for a 15-mile wind. These values apply only to ordinary building ma terials and should not be used for bright metal surfaces having a low emissivity. In special cases, where surface conductance coefficients become important, factors in the over-all rates of heat-transfer, more-selective coefficients may be -required. The surface conductance values given in Table 1, Section A are based on recent tests and are for still air conditions and surface emissivities of 0.83 and 0.05 respectively, and may be used where it is desirable'to differentiate between horizontal and vertical surfaces or where coefficients applicable to low-emissivity surfaces arc required. Air Space Conductance The transfer of heat across an air space involves the boundary surfaces as well as the intervening air,.consequently the factors influendng surface conductance play an important part in determining the conductance of the air space, .The coefficients given for air space conductance represent the total conductance from surface to surface. The. radiation portion of the coefficient is affected by the. difference in temperature between the boundary surfaces and by their respective