Document gD5ZLj1Q3411VYEJbVpoyJXpq

FlC 39-2 -- Fountains should be conveniently located so that employees can maintain their daily water intake tamers of salt tablets at the dnnking fountains, with instructions posted nearby, or to supply the fountains with dilute (0 9 per cent) salt solution Use of salt tablets is essential on heavy, hot jobs where salt loss from per spiration can lead to heat cramps Some workers may be on salt-restncted diets, but they will have already been warned about their own salt requirements and are not likely to be doing heavy work Other persons are nauseated bv fairly high salt concentra tions This condition can be avoided by the use of enteric-coated salt tablets which pre vent dissolving of the salt m the stomach, by the use of impregnated tablets which dissolve slowly in the stomach, or to some extent by the use of salt tablets containing dextrose Diabetics who may be working in the plant should be warned about tablets containing dextrose and, if necessary, should be provided with tablets without the sugar Where city water is available on construc tion work, a water line can be extended to upper floors as the building is erected A standard dnnking fountain can be installed on each floor On some types of work, such as highway, pipeline, power line construction, and timber clearing, the drinking water source is so re mote that it is impractical to pipe water to the job Some companies have successfully solved this problem by using portable dnnk ing fountains These fountains have an in sulated tank equipped with an angle jet drink ing nozzle The tank has an air pump and pressure release valve so that it can be pumped up to the necessary operating pres sure Containers should be kept scrupulously clean and should be stenlized daily with steam, boiling water, or chlorine solution Under no circumstances should use of a common drinking cup or ladle be permitted If drinking cups are required, they should be single-service paper cups kept m a sanitary container at the dnnking faucet, with a re ceptacle provided for disposal American Standard A117 1, section 5 7 Making Buildings and Facilities Accessible to, and Usable by, the Physically Handicapped mentions modifications necessary for use by the physically handicapped Dnnking fountains are usually not per mitted to be installed in any toilet room Bubblers are usually not permitted by codes to be installed as an integral part of--or con nected to--another fixture, such as a lavatory or sink Carafes (vacuum-type bottles) that are frequently used m private offices are a po tential source of bacterial contamination They should be rinsed and refilled daily and cleaned penodically, using a sanitizer, such as a cationic quartemary ammonium germi cide Washrooms and locker rooms American Standard Z4 1, Minimum Require ments for Sanitation in Places of Employ ment, serves as a guide to the types and sizes of washroom, locker rooms, and accessones A large, single washroom and locker room may be sufficient for a compact plant employ ing fewer than 500 people Washrooms in a large one-story plant generally are scattered throughout the building If the plant con sists of a series of separate buildings with only a few people working in each, all the facilities may be placed in a centralized build ing This arrangement has been successful in such establishments as chemical plants, oil refineries, and railroad yards If the plant is relatively small, it is advis able to have the dressing rooms, lockers, and washrooms near the entrance In a larger plant it is better to have these facilities in 1213