268 CHAPTER 14 1949. Guide Tabus 5. Heat Loss Calculation Sheet fob Uninsulated Residence (Fio. {2) A B C DE F G -- Room or Space Part op Structure or Infiltration. Air Changes and Closet Bedroom B and Closet Bedroom C and Closet Bedroom D' Bathroom 1 Bathroom 2 Living Room Dining Room Kitchen and ' Entrance to Garage _. Lavette and Vestibule Entrance Hall Garage Recreation Room*! Walls . Giass Ceiling infiltration (K)* Walls Glass Ceiling Infiltration (&)* Walls Glass Infiltration ($)* Walls -Glass Ceiling . Floor over garage Infiltration ($) Walls Glass Ceiling Infiltration (1)* -Walls Glass Ceiling Floor over garage Infiltration (1) Walls Walls (adjoining garage) Glass Floor Infiltration (lH)k Walls Glass (doors) Glass (windows) Floor Infiltration (1H)1 Walls Walls (adjoining garage) Glass Door Floor ` Infiltration (IK)1- Walls Walls (adjoining garage) Glass Door Floor Infiltration (IM)k Walls Door Ceiling* Infiltration^)1 Walls Glass Doors Infiltration (IK)" Floor (heat gain) Gain adjoining rooms Walls Glass Floor infiltration (D" Net Abba or ' CoEFqi- Temp. Heat Loss Totals Air Volume CIENT Dip*.* (Btu per hour) (Btu per hour) 238 sq ft 40 sq ft 252 sq ft 1510 cfhb 0.28 0.45 0.69 0.018* '80 80 39.8* . so 156 sq ft 40 sq ft. 170 sq ft 1020 cthb 0.28 , 0.45 0.69 0.018 80 80 39.84 80 114 sq ft 27 sq ft 129 sq ft 874 cthb 0.28 0.45 0.69 0.018* 80 80 39.84 80 118 sq ft 20 sq ft 1X0 sq ft 110 SQ ft G60 cfhb 0.28 - 0.45 0.69 0.25 0.018* 80 80 39.84 35* 80 30 sq ft 14 SQ ft 55 sq ft 440 cfhb 0.28 0.45 0.69 . 0.018* 80 80 39.84 80 79 sq ft 9 sq ft 35 sq ft 35 sq ft 280 cfhb 0.26 . 0.45 0.69 ' 0.25 0.018* 80 80 39.84 35* SO 267 sq ft 94 sq ft 50 sq ft- 294 sq ft 3745 cfhb 0.28 0.39* 0.45 0.018 80 35* 80 80 166 sq ft 35 sq ft 20 sq ft 1G8 sq ft 2140 cfhb 0.28 1.13 0.45 - 0.018* 80 80 80 SO 96 sq ft 51 sq ft 18 sq ft 17 sq ft 125 sq ft 1595 cfhb 0.28 0.39* 0.45 0.51 80 35* 80 . 35 0.01S* 80 82 sq ft \ 85 sq ft 9 sq ft 19 sq ft 30 sq ft 383 cfhb 0.28. 0.39* 0.45 0.51 0.018* 80 ' 35* 80 80 SO 39 sq ft 21 sq ft 87 sq ft 1110 cfhb 0.28 0.38 0.69 0.018* 80 SO 39.8* SO 167 sq ft 53 sq ft 44 sq ft 2360 cfhb 185 sq ft 0.28 1.13 0.51 0.018* 0.10 45* 45 45 45 -15 220 sq ft 8 sq ft 287 sq ft 2010 clbb 0.10 1.13 0.10 0.01S* 38. 80 20 .SO 5330 . 1440 6910 2180 3490 1440 4660 1470 2560 970 3540 1260 2650 720 3020 960* 950 670 500 1510 630 1640 320 960 310P 400 5980 1280* 1800 5400 3720 3160 720 3080 2150 700* 650 300 2300 1840 1160* 320 780 550 870 . 640 " 2390 ' 1600 2110 2700 1010 1910 -280* -4410* S40 720 570 2890 15,860 % 11.060 8.330 8.300 3,310 3.630 14.460 10.680 6.100 4,650 5,500 3,040 5.020 TOTAL 99.940 Heating;Load 269 Table 6. Summary of Heat Losses of Uninsulated Residence (Btu Per Hour) --- --------- room or Space Walls Ceiling and Roof Floor Glass and Door INFILTRATION Totals Bedroom A Bedroom B Bedroom C Bedroom D Bathroom 1 Bathroom 2 Living Room Dining Room Kitchen Lavette Entrance Hall Garage Recreation 5330 3490 2560 2650 070 1640 7260 3720 2S50 3000 870 ' -1030* 840 . 6910 4660 3540 3020 1510 960 2390 -1270b -- 960 310 --280* 570 1440 1440 970 720 500 320 1800 3880 950 2100 640 3710 720 2180 1470 1260 950 630 400 5400 30S0 2300 550 1600 1910 2890 15.860 *11.060 S.330 8.300. 3.310 3.630 14.460 10.680 6.100 4.650 5.500 3.040 5.020 Design Totals Operating Totals* Percentages* 33.S50 33.850 3S.6 21.720 21.720 24.8 1.560 1,560 1.8 18.190 18,100 20.7 24.620 12.310 14.1 99.940 87.630 100.0 Wall heat laes of 2110 Btuh minus wall heat gains of 12S0, 700 and 1160 Btuh. b Heat gains of 960,310 Btuh. e Heat gain. d Based on H computed infiltration. e Based on Operating Totals. wind velocity. Inside temperature from Table 2 is assumed to be 70 F. The attic is unheated. Assume ground temperature to be 50 F (see Fig. 3, Chapter 37) under basement and garage floors and 32 F adjoining basement walls. Estimate infiltration losses by the air change method. No wall, ceiling or roof insulation is to be con sidered in this problem, but all first and second floor windows, except in the garage, are to have storm sash. The building is constructed as follows (heat transmission coefficients U are in parentheses): Walls: Brick veneer, building paper, wood sheathing, studding, metal lath and plaster (0.28). Walls of dormer over garage, same except wood siding in place of brick veneer (0.26). Attic Walls: Brick veneer, building paper, wood sheathing on studding (0.42). Basement Walls: 10 in. concrete (0.10). Roof: Asphalt shingles on wood sheathing on rafters (0.53). Ceiling (Second floor): Metal lath and plaster (0.69). Windows: Double-hung wood windows with storm sash (0.45). Steel casement sash in basement (1.13). Floor tBedroom D): Maple finish flooring on yeilow pine sub-flooring; metal lath and plaster ceiling below (0.25). Floor {Basement and Garage): 4 in. stone concrete on 3 in. cinder concrete (0.10). Solution: The. calculations for this problem are given in Table 5, and a summary of the results in Table 6. The values in column F of Table 5 were obtained'bv multi plying together the figures in columns C, D, and E. The heat losses are calculated to the nearest 10 Btu. See reference notes for Table 5 for further explanation of data. Attention is called to the summary of heat losses (Table 6) for the uninsulated resi dence. As storm windows are used in this instance the glass and door transmission heat losses of 20.7 per cent are relatively small. The infiltration losses of 14.1 per cent are also comparatively small because the storm windows are equivalent to weatherstripping. In this problem, the wall,.ceiling and floor transmission losses comprise 65.2 per cent of the total. Example 6. Calculate the heat loss of residence shown in Fig. 2 based on the same conditions as in Example 5 but having construction improved or insulated to obtain coefficients as follows: Walls, 0.13; Walls of Dormer over Garage, 0.12; Attic Walls, 0.28; Walls Adjoining Garage, 0.18; Basement Walls {Recreation Room), 0.10^ Roof, 0.53. Ceiling {Second Floor), 0.15. Windows (Same as in Example 6). Floor {Bedroom D), 0.18. Solution: The procedure for calculating the heat losses is similar to that for Example 5. A summary of the results is given in Table 7.