Document g4RaLLa61rD9w6898dqYqeeq
268
CHAPTER 14
1949. Guide
Tabus 5. Heat Loss Calculation Sheet fob Uninsulated Residence (Fio. {2)
A
B
C
DE
F
G
--
Room or Space
Part op Structure or Infiltration. Air Changes
and Closet
Bedroom B and Closet
Bedroom C and Closet
Bedroom D'
Bathroom 1
Bathroom 2
Living Room
Dining Room
Kitchen and ' Entrance to Garage
_.
Lavette and Vestibule
Entrance Hall
Garage
Recreation Room*!
Walls . Giass
Ceiling infiltration (K)*
Walls Glass Ceiling Infiltration (&)*
Walls Glass
Infiltration ($)*
Walls -Glass Ceiling . Floor over garage Infiltration ($)
Walls Glass Ceiling Infiltration (1)*
-Walls Glass Ceiling Floor over garage Infiltration (1)
Walls Walls (adjoining garage) Glass Floor Infiltration (lH)k
Walls Glass (doors) Glass (windows) Floor Infiltration (1H)1
Walls Walls (adjoining garage) Glass Door Floor ` Infiltration (IK)1-
Walls Walls (adjoining garage) Glass Door Floor Infiltration (IM)k
Walls Door Ceiling* Infiltration^)1
Walls Glass Doors Infiltration (IK)" Floor (heat gain) Gain adjoining rooms
Walls Glass Floor infiltration (D"
Net Abba or ' CoEFqi- Temp.
Heat Loss
Totals
Air Volume
CIENT Dip*.* (Btu per hour) (Btu per hour)
238 sq ft 40 sq ft
252 sq ft
1510 cfhb
0.28
0.45 0.69 0.018*
'80 80 39.8*
. so
156 sq ft 40 sq ft.
170 sq ft 1020 cthb
0.28 , 0.45
0.69 0.018
80
80 39.84 80
114 sq ft
27 sq ft 129 sq ft 874 cthb
0.28 0.45
0.69 0.018*
80 80
39.84 80
118 sq ft 20 sq ft
1X0 sq ft 110 SQ ft G60 cfhb
0.28 - 0.45
0.69
0.25 0.018*
80 80 39.84
35*
80
30 sq ft 14 SQ ft 55 sq ft
440 cfhb
0.28 0.45 0.69 . 0.018*
80 80 39.84
80
79 sq ft 9 sq ft
35 sq ft 35 sq ft
280 cfhb
0.26 . 0.45 0.69 ' 0.25
0.018*
80 80 39.84
35* SO
267 sq ft 94 sq ft 50 sq ft-
294 sq ft 3745 cfhb
0.28 0.39* 0.45
0.018
80 35* 80
80
166 sq ft 35 sq ft 20 sq ft
1G8 sq ft
2140 cfhb
0.28 1.13 0.45
- 0.018*
80 80 80
SO
96 sq ft 51 sq ft
18 sq ft 17 sq ft 125 sq ft
1595 cfhb
0.28 0.39* 0.45
0.51
80 35*
80 . 35
0.01S* 80
82 sq ft \
85 sq ft 9 sq ft
19 sq ft 30 sq ft 383 cfhb
0.28. 0.39* 0.45 0.51
0.018*
80 ' 35* 80 80
SO
39 sq ft 21 sq ft 87 sq ft
1110 cfhb
0.28 0.38 0.69
0.018*
80 SO
39.8* SO
167 sq ft 53 sq ft 44 sq ft 2360 cfhb 185 sq ft
0.28 1.13 0.51
0.018* 0.10
45* 45 45 45
-15
220 sq ft 8 sq ft
287 sq ft
2010 clbb
0.10 1.13 0.10 0.01S*
38. 80
20 .SO
5330 . 1440
6910 2180
3490 1440 4660 1470
2560 970
3540 1260
2650 720
3020 960* 950
670 500 1510 630
1640 320 960 310P 400
5980 1280* 1800
5400
3720 3160
720
3080
2150 700* 650 300
2300
1840 1160* 320 780
550
870 . 640 " 2390 ' 1600
2110 2700 1010 1910 -280* -4410*
S40 720 570 2890
15,860 % 11.060
8.330 8.300 3,310 3.630 14.460 10.680
6.100
4,650 5,500
3,040 5.020
TOTAL
99.940
Heating;Load
269
Table 6. Summary of Heat Losses of Uninsulated Residence (Btu Per Hour)
--- ---------
room or Space
Walls
Ceiling and Roof
Floor
Glass and Door
INFILTRATION
Totals
Bedroom A Bedroom B Bedroom C
Bedroom D Bathroom 1 Bathroom 2
Living Room Dining Room Kitchen Lavette Entrance Hall
Garage Recreation
5330 3490 2560 2650
070
1640 7260 3720 2S50
3000 870 '
-1030* 840
.
6910 4660 3540 3020 1510
960
2390 -1270b
--
960 310
--280* 570
1440 1440 970
720 500
320 1800 3880 950 2100
640
3710 720
2180
1470 1260
950 630
400 5400 30S0 2300
550
1600 1910
2890
15.860
*11.060 S.330 8.300.
3.310 3.630 14.460 10.680
6.100 4.650
5.500 3.040
5.020
Design Totals Operating Totals* Percentages*
33.S50
33.850 3S.6
21.720
21.720 24.8
1.560 1,560
1.8
18.190 18,100
20.7
24.620
12.310 14.1
99.940 87.630
100.0
Wall heat laes of 2110 Btuh minus wall heat gains of 12S0, 700 and 1160 Btuh. b Heat gains of 960,310 Btuh. e Heat gain. d Based on H computed infiltration. e Based on Operating Totals.
wind velocity. Inside temperature from Table 2 is assumed to be 70 F. The attic is unheated. Assume ground temperature to be 50 F (see Fig. 3, Chapter 37) under basement and garage floors and 32 F adjoining basement walls. Estimate infiltration losses by the air change method. No wall, ceiling or roof insulation is to be con sidered in this problem, but all first and second floor windows, except in the garage, are to have storm sash. The building is constructed as follows (heat transmission coefficients U are in parentheses):
Walls: Brick veneer, building paper, wood sheathing, studding, metal lath and plaster (0.28). Walls of dormer over garage, same except wood siding in place of brick veneer (0.26).
Attic Walls: Brick veneer, building paper, wood sheathing on studding (0.42).
Basement Walls: 10 in. concrete (0.10).
Roof: Asphalt shingles on wood sheathing on rafters (0.53).
Ceiling (Second floor): Metal lath and plaster (0.69).
Windows: Double-hung wood windows with storm sash (0.45). Steel casement sash in basement (1.13).
Floor tBedroom D): Maple finish flooring on yeilow pine sub-flooring; metal lath and plaster ceiling below (0.25).
Floor {Basement and Garage): 4 in. stone concrete on 3 in. cinder concrete (0.10).
Solution: The. calculations for this problem are given in Table 5, and a summary of the results in Table 6. The values in column F of Table 5 were obtained'bv multi plying together the figures in columns C, D, and E. The heat losses are calculated to the nearest 10 Btu. See reference notes for Table 5 for further explanation of data.
Attention is called to the summary of heat losses (Table 6) for the uninsulated resi dence. As storm windows are used in this instance the glass and door transmission heat losses of 20.7 per cent are relatively small. The infiltration losses of 14.1 per cent are also comparatively small because the storm windows are equivalent to weatherstripping. In this problem, the wall,.ceiling and floor transmission losses comprise 65.2 per cent of the total.
Example 6. Calculate the heat loss of residence shown in Fig. 2 based on the same conditions as in Example 5 but having construction improved or insulated to obtain coefficients as follows:
Walls, 0.13; Walls of Dormer over Garage, 0.12; Attic Walls, 0.28; Walls Adjoining Garage, 0.18; Basement Walls {Recreation Room), 0.10^
Roof, 0.53.
Ceiling {Second Floor), 0.15.
Windows (Same as in Example 6).
Floor {Bedroom D), 0.18.
Solution: The procedure for calculating the heat losses is similar to that for Example 5. A summary of the results is given in Table 7.