Document g44rK2zYJzLozZNOMYE962Jq
Inter Olfica
Personnel and Organization Staff
Hr. Gar/ Bejma, Safety Engineer Reboarch and Engineering Center
5 April 1983
oe R. Quarles S. Pant M.D.
Subject! Bulk Sample Analysis for Asbestos
The sample from the Trane heater core test stand (Ityno lab) that you submitted
on March 21, 1983 vas analyzed for the presenoe of asbestos type and percentage.
Environmental Research Group, Ino. of Ann Arbor performed the analysis by
polarized light microscopy (PLM).
'
Results indicate positive identification for asbestos!
11% chrysotile 27% amosite
Therefore, this material must be regarded as containing asbestos, and all aspects
of OSHA Asbestos Regulation 29 CFR 1910.1001 must be complied with. Please
inform all appropriate parties of these findings, and ensure that the Company
asbeotoo policy is followed.
A. R. Amberg, Industrial Hygienist Industrial Hygiene & Toxicology Department Employee Health Servioes
8006 2039 SCF-FORD-3299
PRODUCED BY FORD