Document g2zaEKMq6NEqyBVDZ97YVDBJQ
P F. KOHLHAAS
assistant vice president
ENGINEERING
X s4?^
:j I.-: `U
AF`r' 7 7 /;--
fefe/7-,: ,.....
- ^:arMg
April 7, 1955
CHIEF ENGINEER! OF DIVISIONS AND 'ASSOCIATED SUBSIDIARIES P.'-perty of
R E F t i' ii N C ROOM
File No__ %%% Dea: Sir:
' ^4
^RRrn
-'
-4* -1 <3 -J?S
Corrulux Skylights and Windows
The use of skylights and windows, in the design of mill buildings with corrugated steel roofing and siding, has been greatly reduced during the past ^several years due to the following reasons:
** mm % MAY 2 01965 ]
/
a. Ordinary glass is often broken and the use of shatterproof glass throughout could not be justified.
b. Broken glass would not be replaced, causing
an unsightly appearance and unsafe conditions. c. Glass would not be cleaned when dirty. d. Glass required special framing.
There is now on the market a comparatively new product, Corrulux, a glass substitute which overcomes most of these objections. Corrulux is a shatter proof , corrugated, translucent material made from tough weather resistant resins reinforced with fiber glass. It is installed Just like any sheet of corrugated metal or asbestos and fastened down in the same manner as metal or asbestos sheets, requiring no special framing. The manufacturer claims savings over glass in four ways: (l) Engineering, (2) Framing, (3) Total First Cost, and (4-) Maintenance. Corrulux weighs l/2 pound per square foot with a nominal thickness of l/l6 of an inch and will carry more than 100 pounds per square foot on a it- foot span, with the standard 1-1/V1, 2-1/2", 2.67" and. it-.2" corrugations. Corrulux is manufactured by the L. 0. F. Glass Fibers Company, formerly the Corrulux Division of the LibbeyOwens, Ford Glass Company, P. 0. Box 20026, Houston, Texas.
The Safety, Insurance, and Engineering Divisions of the United States Steel Corporation have approved the use of Corrulux under certain conditions. These conditions are outlined in Laboratory Report No. 11864 dated July 1, 1951, revised March 23, 1953, and issued by Factory Mutual Laboratories under the direction of the Associated Factory Mutual Fire Insurance Companies, 184 High Street, Boston 10, Massachusetts. The Report consists of five pages and eleven appendix sheets. Under the heading "Conclusions" on page 4 and 5 of the Report, are stated the conditions under which Corrulux may be used in your plants.
' M Ffti&gr /- <e
7# <?//,
^ /=?/})P/P
/
P. 7- /
*tS USH0 002832
CHIEF ENGINEERING EXECUTIVES
-2-
April 7, 1955
A sufficient number of copies of the Report, for distribution among the plants of your Di-vision, are submitted herewith. Further information on Corrulux and additional copies of the report, if desired, should be obtained from the manufacturer.
We would like to be advised of your reaction with regard to the possible use of this material, and of any contemplated application.
Very truly yours,
Assistant Vice President Engineering
Attach.
RNB:maf cc: J. L. Young
USHO 00283