Document g2yvbYKee2aymq29Zbjpz7MQa

Lighting Wire Solid Tinned Copper Sotureted OI Sfcid * Silicon* Rubber ROCKTHERM SILICONE LIGHTING WIRE Table SR-C, 600 Volts, Max. Operating Temp. 125C CONSTRUCTION: Solid tinned copper conductor, siiicone rubber extrusion, heavy duty saturated glass braid. APPLICATION: These cables are designed for use on 600 volt lighting circuits and small power loads where a high temperature, moisture-resisting cable is required. ADVANTAGES: Table SR-C conductors offer a mini mum in size and weight for wiring circuits requiring a cable to operate at up to 125 C. continuously. Size AVVG Bore Diameter fin.) Insulation Thickness in 64ths Braid Thickness l mils) Nominal Finished Diom. {ins.) Ampacity* Conduit Sit*'* Net Weight (Ibt/M-) 14 .06 2 20 .17 30 \h 25 (}12 .08 2 20 .19 40 34 10 .10 3 20 .24 50 % 55 L______w_______ !_____ '__"i ____________A________________________ _tn_________ ________________'A____________Q_A_____ I Silicon* Rubber 1 Power Cable ROCKTHERM SILICONE POWER CABLE (NEC Type SA) Table SR-E, 600 Volts, Max. Operating Temp. 125C CONSTRUCTION: Stranded tinned copperconductors insulated with silicone rubber and covered by a heavy duty asbestos braid with a heat, flame and moisture-resistant finish. . APPLICATION: 600 volt power cable for installation in high ambient temperature locations under- wet or dry conditions. ADVANTAGES: Rocktherm siiicone rubber insula tion is a very high quality electrical insulation suit able for long term exposure to high ambient and/or conductor temperatures. Size AWG Or CM Stranding Bar* Diameter fin.) insulation Braid Thickness Thickness in 64ths (mils) Nominal Finished Diom. Ins. Ampacity* Conduit Size** 14 7 12 7 10 7 37 67 47 27 1 19 .07 3 40 .09 3 40 .12 3 40 .15 4 45 .rs 4 45 .23 4 45 .29 4 45 .33 5 45 .26 .28 .30 .36 ' .40 .45 .51 .58 30 40 50 65 85 115 145 [70 % % % / i'a i'A I'/s 1/0 2/0 3/0 . 4/0 19 f9 19 .37 5 45 .42 5 45 .47 5 45 .53 5 45 .62 200 2 .67 230 2 .72 265 2 .78 310 2 250,000 300,000 350.000 500,000 37 37 37 37 .58 6 45 .63 b 45 .63 6 45 .81 & 45 .86 335 2'A .9) 380 lYi .96 420 3 uo 500 3 `Ampacity based on 30C. ambient ot 125cC. conductor temperatures, 3 conductors in conduit, per NEC. "Conduit size based on 3 conductors m conduit, per NEC, ^Copyright 1978 Net Weight (Ibi/M'J 40 so 70 100 140 195 290 370 44s 540 660 810 965 1135 1300 1300 RBB 02812 SC-ELEC-07102 Silicon* Rubber Interlock *<f Armor ROCKTHERM INTERLOCKED ARMOR (NEC Type SA Singles) 3 Conductors, 600 Volts, Max. Operating Temp. 125C CONSTRUCTION: Stranded tinned copper conduc tors insulated with Rocktherm silicone rubber and covered with an asbestos braid. Three conductors cabled with fillers when necessary and enclosed in an interlocked armor of either steel or aluminum. APPLICATION: Rockbestos silicone insulated inter locked armor cable is recommended for use on 600 volt heavy duty power wiring applications, parti cularly where a moisture-resisting insulation is re quired. ADVANTAGES: This construction is designed to operate at 125C. continuously, and has superior moisture and chemical resistance. Six*. AWG orMCM 6 4 2 i I/O 2/0 3/0 4/0 250 300 350 400 500 750 Stranding 7 7 7 19 J9 19 19 19 37 37 37 37 37 61 OvtraJI D(Ofn#t*r (in.) 1.14 1.24 1.37 1.52 1.61 1.71 1.82 t .95 2.12 2.23 2.35 2.45 2.63 3.09 Nat Weight, Lbt./M' AL Armor 590 775 1030 1350 1600 1920 2300 2770 St**l Armor 890 1120 1475 1790 2070 2400 2900 3320 3270 3800 4325 4900 5880 8823 3860 4450 5000 5600 6650 9730 'Rating based an one 3 conductor coble in air. 40C. ambient, ot I25C. conductor temperatures, per IPC8A. Ampacity* 98 128 167 192 219 250 286 336 370 415 457 483 558 703 Printed in U S A. THE ROCKBESTOS COlvlFSVT-q'V' New Haven, Connecticut 06504 USA RBB 02813