Document g2yvbYKee2aymq29Zbjpz7MQa
Lighting Wire
Solid Tinned Copper
Sotureted OI Sfcid *
Silicon* Rubber
ROCKTHERM SILICONE LIGHTING WIRE Table SR-C, 600 Volts, Max. Operating Temp. 125C
CONSTRUCTION: Solid tinned copper conductor, siiicone rubber extrusion, heavy duty saturated glass braid.
APPLICATION: These cables are designed for use on 600 volt lighting circuits and small power loads
where a high temperature, moisture-resisting cable is required.
ADVANTAGES: Table SR-C conductors offer a mini mum in size and weight for wiring circuits requiring a cable to operate at up to 125 C. continuously.
Size AVVG
Bore
Diameter fin.)
Insulation Thickness in 64ths
Braid Thickness
l mils)
Nominal Finished Diom. {ins.)
Ampacity*
Conduit Sit*'*
Net Weight (Ibt/M-)
14
.06 2 20
.17
30 \h
25
(}12 .08 2 20 .19 40
34
10
.10 3 20
.24
50 %
55
L______w_______ !_____ '__"i ____________A________________________ _tn_________ ________________'A____________Q_A_____ I
Silicon* Rubber
1
Power Cable
ROCKTHERM SILICONE POWER CABLE (NEC Type SA)
Table SR-E, 600 Volts, Max. Operating Temp. 125C
CONSTRUCTION: Stranded tinned copperconductors
insulated with silicone rubber and covered by a
heavy duty asbestos braid with a heat, flame and
moisture-resistant finish.
.
APPLICATION: 600 volt power cable for installation in high ambient temperature locations under- wet or dry conditions.
ADVANTAGES: Rocktherm siiicone rubber insula tion is a very high quality electrical insulation suit able for long term exposure to high ambient and/or conductor temperatures.
Size AWG Or CM
Stranding
Bar* Diameter
fin.)
insulation Braid
Thickness Thickness
in 64ths
(mils)
Nominal
Finished Diom. Ins.
Ampacity*
Conduit Size**
14 7 12 7 10 7 37
67 47 27 1 19
.07 3 40
.09 3
40
.12 3 40
.15 4 45
.rs 4 45
.23 4 45 .29 4 45 .33 5 45
.26 .28 .30 .36 '
.40 .45 .51 .58
30 40 50 65
85 115 145 [70
% % % /
i'a
i'A
I'/s
1/0 2/0 3/0 . 4/0
19
f9 19
.37 5 45 .42 5 45 .47 5 45 .53 5 45
.62 200 2 .67 230 2
.72 265 2 .78 310 2
250,000 300,000 350.000 500,000
37 37 37 37
.58 6 45 .63 b 45 .63 6 45 .81 & 45
.86 335 2'A .9) 380 lYi .96 420 3
uo 500 3
`Ampacity based on 30C. ambient ot 125cC. conductor temperatures, 3 conductors in conduit, per NEC. "Conduit size based on 3 conductors m conduit, per NEC,
^Copyright 1978
Net Weight (Ibi/M'J
40 so 70 100
140 195 290 370
44s 540 660 810
965 1135 1300 1300
RBB 02812
SC-ELEC-07102
Silicon* Rubber
Interlock *<f Armor
ROCKTHERM INTERLOCKED ARMOR (NEC Type SA Singles) 3 Conductors, 600 Volts, Max. Operating Temp. 125C
CONSTRUCTION: Stranded tinned copper conduc tors insulated with Rocktherm silicone rubber and covered with an asbestos braid. Three conductors cabled with fillers when necessary and enclosed in an interlocked armor of either steel or aluminum.
APPLICATION: Rockbestos silicone insulated inter locked armor cable is recommended for use on 600
volt heavy duty power wiring applications, parti cularly where a moisture-resisting insulation is re quired.
ADVANTAGES: This construction is designed to operate at 125C. continuously, and has superior moisture and chemical resistance.
Six*. AWG orMCM
6 4 2 i
I/O 2/0 3/0 4/0
250 300 350 400 500 750
Stranding
7 7 7 19
J9 19 19 19
37 37 37 37 37 61
OvtraJI D(Ofn#t*r (in.)
1.14 1.24 1.37 1.52
1.61 1.71 1.82 t .95
2.12 2.23 2.35 2.45 2.63 3.09
Nat Weight, Lbt./M'
AL Armor
590 775 1030 1350
1600 1920 2300 2770
St**l Armor
890 1120 1475 1790
2070 2400 2900 3320
3270
3800 4325 4900 5880 8823
3860 4450 5000 5600 6650 9730
'Rating based an one 3 conductor coble in air. 40C. ambient, ot I25C. conductor temperatures, per IPC8A.
Ampacity*
98 128 167 192
219 250 286 336
370 415 457 483 558 703
Printed in U S A.
THE ROCKBESTOS COlvlFSVT-q'V' New Haven, Connecticut 06504 USA
RBB 02813