Document g2kjwneoQmOaE93wYa5rO2Na9
Robert L. Lembke, M.D.
(conoco)
To
Mr. James A. DeBernardi
Date 9-26-75
Attached for your information is a copy of Dr. Steffey's report to me covering his industrial hygiene inspection of the Lake Charles VCM Plant, September IS, 1975.
The report is self explanatory.
We appreciate the hospitality shown Dr. Steffey during his visit to your plant.
Robert L. Lembke, M. D. Medical Director
ems att Carbon copies with att: R. E. Lehmkuhl Robert Gerwig Leon Vernon David Kuhn
CC/?
Interoffice Communication
tn<\'
1 /*'
ik-
To Robert L. Lembke, M.D.
From
Oran D. Steffey
Date September 26, 1975
Subject
ANNUAL INDUSTRIAL HYGIENE INSPECTION - LAKE CHARLES VCM PLANT
t&AJjJU
4**JbJe*Z*I
An Industrial Hygiene inspection was made of the Lake Charles VCM Plant
on the afternoon of September 18, 1975. The purpose of the inspection
was to physically check the installation from the standpoint of OSHA
Standards which cover General Environmental Control-Sanitation and
general use of toxic and hazardous materials.
The following areas were covered from a general industrial hygiene standpoint:
Main Office Maintenance Warehouse No. 2 Instrument Shop
Control Building Warehouse No. 1 Welding Laboratory
The following comments are made relative to the above areas of the VCM Plant:
Main Office and Control Room - These areas were found to be in good condition.
Maintenance - The storage area over the office should be cleaned and straightened. Materials should be stored in an orderly manner. This area is not posted for maximum load limit. There seems to be some doubt as to some previous engineering figures which were issued as to the load limit to be used. This should be arrived at, posting should be done, and the load should be adjusted accordingly.
Warehouse No. 1 - Some shelving has large heavy items such as large valves stored on upper levels. It is recommended that these types of items be placed on the lowest level of shelves. This would not only remove the possibility of a heavy item dropping on someone but would allow for easier access to the materials.
Warehouse No. 2 - Floors in this warehouse should be swept and maintained in cleaner condition. Some items are stored on upper level shelves in very unstable conditions. It is recommended that heavy items be stored on lower shelves for easier and safer handling. There are some palleted
items which should be re-palleted and stacked in a safer manner.
Welding - This area was found to be in good shape.
Instrument Shop - This area was found in fairly good shape.
CCR 000016546
Robert L. Lembke, M.D. September 26, 1975 Page Two
Laboratory - This area has been improved. The First Aid room has been cleaned and painted. The exterior of the lower cabinets in this room should be washed and should be kept clean.
The conditions in this plant are very good. Much effort is being made to keep working areas clean and safe. The people are to be commended for their interest shown.
Emphasis must be made for a continuous effort in support for health in all phases of work in the plant since there will be an increased demand as the result of the standards making program in OSHA.
The Medical Division should receive a copy of the summary of the Monthly Monitoring Results. Those which have previously been compiled should be issued so that medical information can be brought up to date concerning any potential exposures to personnel in the VCM Plant
C.
a/ w to
^r
Industrial Hygienist
rla