askarels
Meeting - Feb, 17 & 18, 1966
I* QUALITY IMPROVEMENT NEEDS:
.
A. Electrical Values Delivered to Customers
1) Resistivity 100oC.
a) Capacitor Aroclor; 5, 000 X lO^ohm cm (Present min. is 500 X lO^ohm cm)
b) Transformer askarels, 700 to 300 X lO^ohm cm. (Present min. is 100 X lO^ohm cm)
2) Power Factor lOO^C. , 60 eye.
a) Capacitor Aroclor; 0. 15% to 0. 3%
b) Transformer askarels; 1% to 3% (Present min. is 5% as we package but on reaching the customer it may be above 20%)
3) Power Factor 100 C. 1KC
a) Capacitor Aroclor; 0. 02% to 0. 05%
b) Transformer askarels; 0. 15% to 0.3%
REMARKS: French, German, and Japanese askarels conform
with the above as delivered to us. Evidentally, this holds also
as usually delivered to their customers. While we can and at
times do meet these levels on our askarels as freshly earth
refined and placed in our storage--by the time our askarels reach
the customers they are usually considerably off these guide lines.
B. Biphenyl Content:
Capacitor Aroclor: 0. 025% (250ppm) max.
(Competitive material shows none to merely a trace of biphenyl. )
0196775
TOWOLDMONOQ57311
2.
Stability:
Our present limits for capacitor Aroclor are:
Aroclor 1242
Aroclor 1254
1) Hydrolysis
0. 5 ppm
1. 0 ppm
2) Westinghouse Test
1. 0 ppm
3) Monsanto (Thermal)
0. 4 ppm
0. 5 ppm
4) Thermal-chemical
0. 75 ppm
Anniston material runs from occasionally the indicated maximum
to usually 40 to 70% of the maximum values, depending on the
individual test.
More recently WGK has demonstrated their known ability to con form with the maximum limits. Given the right conditions, potentially WGK could do as well as Anniston.
However, the stability analysis of competitive material indicates that the quality of our normally best Aroclor made at Anniston is not as good as comparable material from Japan, England, Germany, and France, as compared in this same order in the following table:
\ 0196776
TOWOLDMONOQ57312
3.
Test: Hydrolysis
STABILITY COMPARISON
of Foreign Made Chlorinated Biphenyl
Aroclor 1242
Aroclor 1254
Kanechlor 300; 0. lppm
Kanechlor 500; 0. lppm
Pyroclor 1242; 0. 08 ppm
Pyroclor 1254; 0. lppm
Clophen A-30; 0. 04ppm
Clophen A-50; 0. 17ppm
Pyralene 1499; 0.04ppm
---------------------------------------
Westinghouse
Pyroclor 1242; 0. 30ppm Clophen A-30; 0. 20ppm Pyralene 1499; 0. 20ppm
Monsanto (Thermal)
Kanechlor 300; 0.2ppm Pyroclor 1242; 0. 09ppm Clophen A-30; 0. 09ppm Pyralene 1499; 0. 09ppm
Kanechlor 500; 0. 2ppm Pyroclor 1254; 0.24ppm Clophen A-50; 0. 34ppm
Thermalchemical
Kanechlor 300; 0.42ppm Pyroclor 1242; 0. 19ppm Clophen A-30; 0. 35ppm
------------------------- -----------------.
Pyroclor 1254; 0. 65ppm
------- -------------------------- --------
Pyralene 1499; 0. 17ppm
------- -----------------------------------
The above stability values appear 3 to 5 times better than our stability
specification limits and in many respects 2 to 3 times as good as our
best Aroclor made at Anniston.
Accordingly, our stability goals needed to be competitive in stability
quality appear clear and orderly.
0196777
TOWOLDMONOQ57313
4.
II. EARTH TREATING EFFICIENCY: This is directed at moisture removal and improvement of Power Factor and Resistivity.
It is not known whether we use the best available earth refining pro cess. Variables are type earth, minus 200 mesh versus 60/90 vs 30/60; drying to below 1% moisture; conditioning temperature; amount of earth; temperature and time of treating; method of treating, i. e. , batch versus percolator; earth removal; storage of conditioned earth.
III. NEED TO CLEAN UP TCB and TTCB ELECTRICALLY There are no electrical quality specifications applicable to Hooker supplying TCB and TTCB for transformer askarels. At prevailing prices Hooker is not receptive to such restrictions.
The electrical properties of our incoming chlorobenzenes are quite bad and we do not check them.
It would seem prudent for us to earth refine these materials, check the results, and not use them if they do not respond satisfactorily.
IV. PACKAGING:
A. Merits of Hot Packaging?
It helps eliminate moisture problem in our factory and would
seem to create the moisture problem at the user end, if the
material cools in storage and transit.
0196728
TOWOLDMONOQ57314
B. Contamination
.
1) From loading lines and pumps
2) From the packages
3) From taped sample bottles
C. Drums
1) Are our drums adequate for international shipment?
2) One coat phenolic vs two coats phenolic formerly used vs
galvanized formerly used, vs galvanized 16 gauge and rolling
rings used by Bayer.
3) Bung gasket material?
5.
V. TEST METHODS
A. Electrical Tests
1) Power factors and resistivity methods, WGK versus Anniston
versus customers
2) Need for capacitance standard to check bridges.
3) Anniston was reading low power factor and also resistivity
incorrectly.
4) Both Anniston and WGK probably would read high power factors
incorrectly.
5) Need PF and Resistivity procedures properly written for
customer use, especially international. This is directed at
instructions that might give chance for customer correlation
with our methods.