Document g2avgB8K491rjkOQyKG77JQK9

,. ..SEARCH AND development report No, 227*J, January 17, 1973 GENERAL OFFICE W. G. KRUMMRICH PLANT ichutzenhofer, H. L. Campbell (H. J. Horner) ; various river water samples with sufficient sensitivity 'i sub-parts per billion levels. led for Krummrich Plant PCB strategy as related to Federal' water quality requirements. al procedures have been applied to river water samples -of reaching PCB levels compatible with the.vEPA e of 0.01 ppb. from sampling sites on the Mississippi River north of ,c out-fall show positive PCB levels of at least an ' magnitude larger than 0.01 ppb. Data from a Missouri .ip-ling is inconclusive and re-sampling is recommended. K. L. Schutzenhofer H. L. Campbell DSW 310803 CONFIDENTIAL is the property of Monsanto Company and the recipient j* responsible for its safekeeping fion. It contains confidential informal ion of Monsanto Company which must not be revealed to unauthor ized persons or sent outside the company without proper authorization. is to be retained in a secure file or de strayed* STLCOPCB4070789 ' AR&D Report No. 227** Page 2 January 17, 1973 Details Foreword The Environmental Protection Agency (EPA) guideline for PCB In receiving waters is expected to be 0.01 parts per billion (ppb). Calculations based on current Krummrich losses would indicate a level, in the Mississippi River, at less than this concentration. However contamination from hon-plant sources is expected, due to the wide use of PCB in the past -- plasticizers, solvents, insulators, etc. At present no data is available, relating the PCB levels in the Mississippi (or other near-by rivers) north of the Plant outfall. . Three (3) one-gallon samples of river water were taken at sites at or near the Chain of Rocks (Mississippi), north of the Illinois river (Mississippi) and at St. Charles (Missouri River). Analyses were performed using techniques adapted or developed in this laboratory, during recent months, for reaching PCB levels compatible with the EPA guideline. Experimental Two different procedures were used to examine the samples. Both utilize a minimum one-gallon sample size, giving at least a four-fold increase in detection limit over our present analytical method. The basic difference in these techniques is the manner in which the PCB' s are collected or isolated from the water sample. A brief description of the procedures follow. A. Charcoal Column Filtration This procedure is an adaptation of Berg's charcoal method for separation of PCB's from DDT group pesticides. Our technique is based on the fact that PCB's are adsorbed from water onto charcoal and can be quantitatively removed with cold benzene. The choice of charcoal is critical - only Fisher cocoanut charcoal for decolorizing will work. . Recoveries of 75? for Aroclor 12*12 and 92? for 125** were obtained, and presented no observed alteration to overall GC peak profile. Using a filter column containing about 1.5 gram of charcoal the thru-put is 1.5 liters of . particulate-free water per hour. The system can handle up to J? microgram of PCB. Practically, the filtration is limited to 2-3 gallons of sample as much larger' volumes ' would become quite time consuming. SW 310804 ' STLCOPCB4070790 AR&D Report No. 2274 Page 3 January 17, 1973 Experimental (Continued) .. B. Aluminum. Sulfate Sedimentation This method is currently under examination in our laboratory, and as such can only be considered as semiquantitative at best. It is based on observations - in . this lab and of other workers - that low levels of PCB and some organochlorlne pesticides are almost completely removed from surface waters by sedimentation techniques (contaminants are adsorbed on slowly descending particulate matter). In this work, 1.2 grams of Al2(S0lj)3 18 H2O per gallon was added to the water sample and sedimentation allowed to proceed over night. Although clarification is apparent in several hours total "settling-out" requires much longer periods of standing. The sediment or precipitate is collected by filtration after decantation of the supernatant, and analyzed for adsorbed PCB using standard procedures. As indicated, this method is now under evaluation, and capacity and recovery data have not been obtained at this time. The volumes of water that ' can"be treated and analyzed in this manner, although more than that of the charcoal filtration, is also limited in that very large quantities would become too cumbersome to handle in ordinary laboratory equipment. , C. Analytical Background (Blanks) Analytical blanks were obtained periodically to establish the apparent laboratory and reagent PCB-background at the times of the analyses. This Involved working thru all steps of each procedure, in addition to examining several Individual chemicals and pieces of equipment for contamination. Results - Discussion The most critical point in this work was to be able to reach PCB levels that are compatible with the EPA guideline of 0.01 ppb. This has been achieved in part by being able to analyze large volumes of water. In addition, changes in gas chromatographic operational parameters have resulted in an improved instrumental sensitivity. With the AR&D instrument 0.03 nanograms, per micro liter can be detected over base-line noise. This provides a lower detection limit, taking the equivalent of one-gallon of water as sample, of 0.01 ppb. Unfortunately our laboratory background of apparent PCB1s limits our lowest reportable level to about 0.05 ppb at best. DSW 310805 STLCOPCB4070791 AR&D Report No. 227^ Page 4 January 17, 1973 Results - Discussion (Continued) The analytical data obtained by the two procedures are summarized in the attached Tables I and II. Results from the charcoal-column filtration (Table I) have been corrected for the appropriate analytical blanks. Both sites on the Mississippi River, north of the Plant show positive levels at least an order of magnitude above the 0.01 ppm guideline. The PCB's found were essentially of the Aroclor 125^ type. The result, by charcoal filtration, of the sample from the Missouri River Indicates that it Is almost free of PCB residue. The amount was approximately equal to our analytical background. " Table II shows the range of the quantities found by the sedimentation procedure.- the values are uncorrected for analytical background. Unfortunately during the period of analysis by this technique, the PCB background was inconsistent and varied over a greater than normal range. We felt that under such circumstances, the assignment of any given background value to a set of analyses Is unrealistic. Except for. one sampling site the remainder were run In duplicate, using a fresh gallon sample for each analysis. The background range reported gives the highest and lowest value obtained during the analytical interval. It can be seen that all the samples are positive with respect to this background. It should be noted also, that by the sedimentation technique, a . definite PCB residue is indicated in the sample from the Missouri. The reason for this disparity betv'/een procedures is not apparent. An evaluation of the data from either of the two methods indicates the presence of PCB residues in the Mississippi north of the Krummrich out-fall. The sampling sites were fab enough up-stream to preclude any contribution from our waste discharges. Results from the Missouri River analyses are inconclusive at this time, and when practicable additional sampling should be undertaken. K. L. Schutzenhofer H. L. Campbell dy DSW 310806 STLCOPCB4070792 [ ' . * . AR&D Report No. 227*1 f. January 17, 1973 Table I ` PCB's by Chardoal Column Filtration Sample ppb - corrected for anal, blank Miss, at Chain of Rocks, 12/13/72 0.22 Miss, north of Illinois River, 12/20/72 . 0.19 ' Missouri River, 12/13/72 <"0.05 (1) Table II PCB*s by Sedimentation with Al2(SOi4)^ Sample. ______ _ . Miss, at Chain of Rocks, 12/13/72 Miss, north of Illinois River, 12/20/72 Missouri River, 12/13/72 Anal. Background range in ppb - uncorrected for anal. * - background 0.21 to 0.39 0.39 (2) 0.2*1 to 0.31 0.05 to 0.17 (3) 1. or less than twice anal, blank. 2. single analysis only. 3. based on one-gallon sample size. DSW 310807 STLCOPCB4070793