Document g2ab37zY8GVL0825Qy1pjak1e

IC/ETP-88 HIGH TEMPERATURE LIQUID PHASE HEAT TRANSFER FLUID 300F. TO 750F. Monsanto TOWOLDMONOQ40228 V *-A Heat transfer fluids are intended only for indirect heating pur poses. Under no circumstances should this product contact or in any way contaminate food, ani mal feed, food products, food packaging materials, food chem icals, pharmaceuticals or any items which may directly or in directly be ultimately ingested by humans. Any contact may con taminate these items to the ex tent that their destruction may be required. Precautions against ignitions and fires should be taken with this product. NOTICE: Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent. MONSANTO MAKES NO WARRANTIES AS TO THE FIT NESS FOR A PARTICULAR PURPOSE OR MERCHANTA BILITY OF ANY PRODUCT RE FERRED TO, no guarantee of satisfactory results from reliance upon contained information or recommendations, and disclaims all liability for any resulting loss or damage. In certain countries of Western Europe and the Far East, Mon santo sells Therminol Heat Transfer Fluids under the brand name "Santotherm" heat trans fer fluids:' Corresponding Therm inol and Santotherm fluids are identical in composition. 2/77 Supercedes Bulletin No. IC/FF-43 Therminol" 88 synthetic heat transfer fluid offers outstanding high temperature heat transfer properties along with high temperature pumpability. Up to 750F., Therminol 88 fluid is ideally suited as an alternative to hard-to-handle inorganic salts. Therminol 88 fluid is designed for use in non-pressurized in direct heating systems. It delivers efficient, dependable process heat with no need for high pres sures or costly venting equipment. Therminol 88 is not classified as a fire-resistant heat transfer fluid Consequently, the use of protective devices may be re quired to minimize fire risk The insurer of your property should be consulted relative to this matter. To minimize fluid oxidation,sys tems utilizing Therminol 88 fluid should be blanketed with an inert atmosphere A system relief valve should also be provided. Therminol 88 offers long service life within its recommended op erating temperature range, and is non-corrosive to metals com monly used in the design of heat transfer systems. LYRICAL PROPERTIES'' Composition............................ Mixed Terphenyls Appearance.............................Crumbly wax-like flakes at room temperature. Light amber liquid above Melt Point Odor.........................................Faint, pleasant Moisture Content....................500 ppm Melt Point Begins to soften.................. 140F. (60C.) Completely liquid................ 293F. (145C.) Flash Point, COC.....................375F. (191 C.) Fire Point, COC....................... 460F. (238C.) Autogenous ignition temperature (ASTM)........... >1000F. (>538C.) Coefficient of Thermal Expansion............................ 0.00047F."' (0.00085C."') Boiling Range 10%.......................................687F. (364C.) 90%.......................................784 F. .418 C Molecular Weight....................230 Kinematic Viscosity @ 600F. .0.38 cSt Heat of Vaporization (Calculated)......................... 108 BTU/LB. (60 cal/g.) This data is based upon samples tested in our laboratory and is not guaranteed for all samples Write us for complete sales specifications for Therminol 88 fluid 0634944 Registered Trademark of Monsanto Company TOWOLDMONOQ40229 VARIATIONS OF PROPERTIES WITH TEMPER AT Temper ature F. c, ib/gal Density ID/It3 g/ml Specific Heat BTU/ lb. F. cal/g C. Thermal Conductivity BTU/ hr-ftF. heal/ hr-mC. Viscosity Absolute Kinematic Ib/hr-ft cSt Vapor Pressure torr (mm Hg| g/cm* 77 25 200 93 250 121 9.43 - 70.55 - - 1.133 - - - - 300 149 350 177 400 204 450 232 500 260 550 288 600 316 650 343 700 371 750t 399 800 427 850 454 900 482 8.42 8.25 8.01 7.84 7.67 7.50 7.34 7.09 6.92 6.75 6.59 6.25 6.17 63.05 61.80 59.93 58.68 57.44 56.18 54.94 53.06 5182 50.67 49.32 46.82 46.20 1.01 0.99 0.96 0.94 0.92 0.90 0.88 0.85 0.83 0.81 0.79 0.75 0.74 0.467 0.482 0.497 0.511 0.525 0.540 0.554 0.569 0.584 0.599 0.613 0.628 0.642 t Maximum recommended bulk temperature 750F (399Cl - - 0.467 0.482 0.497 0.511 0.525 0.540 0.554 0.569 0.584 0.599 0.613 0.628 0.642 - - 0.0738 0.0725 0.0712 0.0699 0.0686 00673 0.0660 0.0647 0.0634 0.0621 0.0608 0.0595 0.0581 _ - .1099 .1079 .1060 .1041 .1021 .1002 .0983 .0963 .0944 0925 .0905 .0886 .0865 __ --- _ 0 38 1.57 1.2 002 0.28 1.16 4.5 .006 020 0.37 11 015 0.16 0.70 28 .038 012 0 55 65 .088 0.10 0 46 175 0.238 0.08 0.38 260 0.354 0.07 0 33 450 0.612 006 0 29 800 1 088 0.05 0.25 1100 1.496 0.04 0.23 1500 2.040 0.04 0.20 2250 3060 0.04 0.19 3000 4.080 Th/s dfllB is based upon samples lesled in our laboraiory and is not guaranteed (or all samples Write us tor complete sales specifications for Thermmol b8 fluid 06349A5 TOWOLDMONOQ40230 TY '.NO ` ' Therminol 88 heat transfer fluid is practically non-toxic by inges tion in single doses and by single dermal applications. It is a slight eye irritant and it is not irritating to skin. Although no special handling precautions appear necessary, as with any industrial chemical good industrial practices and personal hygiene should be observed in handling to minimize exposure. In case of contact, re move chemical by flushing eyes or skin with plenty of water. Fluidsoiled clothing should be laun dered before reuse. There is no vapor exposure prob lem when transferring Therminol 88 from its shipping container to the heat transfer system. On the other hand, vapors emitted by Therminol 88 heated to elevated temperatures may be mildly ir ritating and cause discomfort on prolonged exposure. In heat transfer installations, the fluid is used in a closed, non-pressurized system free from leaks and with the expansion tank vent trapped so as to condense any vapors. Consequently, there should be little or no opportunity for workers to come in contact with vapors. While Therminol 88 poses no serious problems with respect to the environment, as a concerned supplier to industry, Monsanto urges the user to maintain a tight system, to correct leakage promptly, and to exercise care in the handling and disposal of this and all other such products. A tight maintenance program not only protects the environment, but keeps employes comfortable, the working area clean, and the system running smoothly. THERMINOL" 88--PRESSURE DROP* TURBULENT FLOW INSIDE CLEAN, ROUND TUBING AND PIPING THERMINOL" 88 --HEAT TRANSFER COEFFICIENTS* TURBULENT FLOW INSIDE CLEAN, ROUND TUBING AND PIPING Monsanto Monsanto Industrial Chemicals Co. 3 unit o! Monsanto Company 800 N. Lindbergh Blvd., St. Louis, Mo. 63166 Phone: (314) 694-1000 0634946 2-3922-0677-92-- Litho m U S A TOWOLDMONOQ40231