CHAPTER 56
1962 Guide And Data Book
causes corrosion of track, bridge structures, and the under side of cars) in transit is eliminated. The capacity of a set of four brine tanks is from 6000 to 7900 lb of crushed ice.
Overhead bunker cars are equipped with eight (for a 40-ft car) or 10 (for a 50-ft car) shallow brine tanks located along tile ceiling of the car. The tanks are filled with crushed ice with (or without) salt through separate hatches in the roof of the car. Water or brine released from the tanks drops onto inclined drain pans located directly under the tanks and then drains down the side wall air flues into floor troughs leading to well traps and drains located at each end of the car. Warm air in the car rises and enters the bunker Space through an opening extending longitudinally at the center of the car be tween the drain pans. Cooled air from around the brine tAhira passes down the side wall flues and is discharged under the floor racks. After being heated by the load, the air rises to the top of tiie car where it is re-cooled and recirculates.
The advantages of overhead bunkers are increased loading space (at the ends of the car) and sufficient air circulation by natural convection to maintain uniform temperature in the load without fans. The disadvantages are increased initial and maintenance costs, increased time required for icing, and the fact that only crushed ice can be used. While only about 200 UJ5. cars are equipped with overhead bunkers, the majority of Canadian cars have overhead bunkers.
Air Gradation
Floor racks, side and end wall flues, and special ceiling
ducts have been provided in refrigerator car construction to
facilitate the circulation of air. Floor racks provide space for
air circulation, under the load. Typical wooden floor racks
consist of crosswise (or herringbone arranged) surface slats,
spaced about one in. apart, attached to longitudinal stringers
spaced about 14 in. on center. The racks are usually con
structed in sections averaging about 4 ft wide and 6 ft long
and are hinged to the side walls. Openings in the longitudinal
stringers permit side to side air circulation and are especially
important in cars equipped with side wall flues. Metal floor
racks designed to support loaded lift trucks are replacing the
usual wooden racks. Height of floor racks varies from about
4%~7M i- Minimum clearance under floor rack slats is 4 in.
Over 40,000 refrigerator cars are equipped with vertical
side wall flues which protect the load from direct contact with
a very warm or cold side wall by permitting air circulation
around the load. Side wall flues are formed by a continuous
plywood or tongue and groove lining spaced 1 to
in
born the regular inside wall by vertical spacers and are open
at the top (above the load) and at the bottom (below the
floor racks). Cars equipped with mechanical refrigeration
have end wall flues in addition to side wall flues. The depth of
flues located at the machinery compartment end of mechanical'
cars varies from 3*/in. when the evaporator is Located in a -
recessed area above the machinery compartment to 12 in.
when the evaporator is located between the end lining and the
machinery compartment bulkhead partition. Flues in the
opposite end of mechanical cars vary in depth from 1 to 2%
in. The side wall flues in mechanical cars, having a ceiling
duct, extend from the ceiling duct to the underside of.the
floor rack slats; and with the complete envelope system they
extend from the ceiling plenum to the air return duct below
the floor.
The principal types of air circulation systems used in
mechanical refrigerator cars are as follows:
1. Open. The air is discharged directly over the load from the evaporator end of the car. The air passes down through the load (and the wall flues) and returns to the evaporator via the chan nels formed by the floor rack stringers.
2. Plenum. Same as the open system except the air is discharged
into a slotted or perforated ceiling supply duct which distributes
the air uniformly over the top of the load.
3. Envelope. The air is discharged into a ceiling duct which,
together with the wall ducts and a special floor duct form a com
pletely closed envelope around the car. The air circulated within
the envelope does not enter the loading area nor does it
from the envelope even when the side doors are opened.
4. Semi-envelope. Same as the envelope system in that the
wall flues extend into the ceiling duct, but the air returns under
conventional open floor racks. The ceiling duct is usually the
same as for the plenum system.
Approximately 13 percent of the mechanical cars have the envelope system, about 3 percent have an open system, and nearly all of the remaining cars have a plenum or semienvelope system. A few mechanical cars have a modified open system with reversed air circulation. In these cars the air is discharged below the floor racks, which are of the solid type with a thick-plywood top, then passes up the side and end wall flues and out over the top of the load. The air is returned to the evaporator through a return air grille located at the top of the machinery compartment bulkhead.
The ceiling duct in mechanical cars is usually aluminum and varies in depth from about 4% in. to 9 in., with a 5 to 6 in. depth most common. Perforations in the ceiling duct usually consist of numerous one or two in. diameter openings uniformly spaced. Some of the mechanical cars have a ceiling
duct with 2 in. shutter openings on approximately 50 in. centers and manually operated louvers for varying (he amount of air circulated within the loading area.
SUPPLEMENTAL REFRIGERATOR CAR
EQUIPMENT
Id addition to the standard refrigerator car construction features, various portable or built-in supplemental equip ment is used with certain types of refrigerator cars. This equipment includes air circulating fans, heaters, mechanical refrigeration (covered separately in the next section of this chapter), and temperature indicating devices.
Forced air circulation in transit is provided by built-in fan systems driven mechanically from the car wheels or elec trically by a generator operated from the car wheel, a special diesel engine, or the mechanical refrigeration power unit.
Heater service is provided by the use of portable heaters placed in and fastened to the bunkers of end bunker cars. About 65,000 portable, thermostatically controlled alcohol heaters have been acquired by the railroad industry for this service; replacing nearly all of the old style charcoal heaters. A limited number of cars are equipped with built-in under slung type charcoal heaters.
Temperature indicating devices, which show the tempera ture of the air inside the car have been installed in a number of refrigerator cars, including all of the mechanical cars.
Air Grculating Fans
Approximately 80,000 refrigerator cars, which include all of the mechanical refrigerator cars and nearly all of the end bunker cars, are equipped with air circulating fans. Forced air circulation reduces the difference in temperature between the various sections of the load and increases the* rate of beat transfer. Fans thus provide better temperature control and reduce the time necessary to bring the load to the desired temperature. All forced air circulation systems in end bunker cars have been designed so that the air flows down through the load and wall flues into the bunkers from below the ' floor racks, up through the ice bunkers, and out the upper bulkhead openings.
All but two of the fan systems used in end bunker cars ob*
Railway Refrigerator Cars
593
frin driving power from the shaft of a small rubber surfaced trheel (about 8 in. in diameter) which is held in contact with the tread of one of the car wheels. Power from the drive 7heel shaft is conveyed to the fan either mechanically or electrically depending upon the type of fan system. Mechan ical fan systems require a drive wheel at each end of the car. Only a single drive wheel is used with electric fan systems.
Tlxe first commercially successful refrigerator car fan sys tem was the floor type shown in Fig. 1. About 40,000 car sets of floor fans were installed during the period from 1938 to 1952. This system consists of two fan housings located under the floor racks about two feet in front of the bottom bunker openings at each end of the car and extending the tridtb of the car. Each housing supports four rubber-mounted ball bearings that carry the shaft on which are mounted seven centrifugal blowers (6% in. in diameter), each operating in a separate compartment of the housing. The blower shaft is belt driven from a pulley mounted on the shaft of the rubber drive wheel. While the direction of rotation of the blowers depends upon the direction of car movement, the air delivery alwayB remains in one direction due to the design of the blower and housing.
A limited number of cars are equipped with mechanically driven fans located in the upper bulkhead openings. Power from the drive wheel b conveyed to the fans by means of a flexible shaft. Either one or two propeller type fans, 15 in. in diameter, are located at each end of the car. With two fans per bulkhead, each b belt driven from pulleys connected to the end of the flexible shaft. When the direction of the car b reversed, the fan rotation b also reversed; but by the use of toting fan blades, the flow of air remains in the same direction.
The fans installed in end bunker cars since 1952 have been electrically driven, of two types. Each type consists of a permanent magnet generator mounted on the rubber drive wheel shaft, and two fan panels located in the upper bulkhead openings, each housing three electric motor driven propeller type fans. The principal differences between the two types are in tiie electrical systems and the fan blades. The electric bn system in the standard ice bunker refrigerator car b a three-phase, low voltage, high current system using threebladed fans, 11% in. in diameter and a six-pole generator with a mechanical reversing switch, which gives the same fan rotation regardless of the direction of car movement. The other electric fan system b a two-phase, three-wire, high vol tage, low current system having four-bladed fans, 13^ in. in diameter, and a four-pole generator with built-in magnetic reversing switch.
Extensive laboratory performance tests have been con ducted* on the two types of electric fan systems. The volume of air circulated in a loaded and iced refrigerator car equipped with either type b about 100 cfm times the car speed in mph. Thus, for a car speed of 60 mph, the total air delivery, would be 6000 cfm (3000 cfm for each of the two fan paneb).
Both the mechanical and electric fan systems have been designed so that the fans may be driven by portable electric motors for precooling before transit and for holding at des tination prior to unloading. This b accomplished by manually moving the drive wheel lever to the off position (which raises the fan drive wheel off the car wheel), mounting a portable Metric motor in the special holding bracket provided on the
underside of the car, and attaching sheaves to the shaft of tbe electric motor and the drive wheel so that the fan drive draft may be belt driven by the electric motor. Two 1 or
np motors are used when precooling a car having mechanical - fans and a single 1,1% or 2 hp motor b used when precooling
a car having electric fans. The standard generator and pre cool motor sheave sizes used for precooling result in fan ro-
tation equivalent to those obtained at car speeds of about 50 to 60 mph. One-half or three-quarter hp motors are com monly used for holding service at destination.
Two types of diesel-electric driven, thermostatically con trolled, fan systems have recently been installed14 in a total of 1000 tingle end bunker cars. Both types are powered by an air-cooled, single-cylinder diesel engine-alternator set located underneath the car. Conventional 40-ft end bunker cars were modified by removing one ice bunker and increasing the ice capacity of the other bunker. Four electric driven fans of conventional design are located in the upper bunker bulkhead opening. Two (or in some cars three) of the fans serve as cool ing fans and the others serve as circulating fans. The circulat ing fans operate continuously and pull air from the loading . area up through special bunker bypass ducts located in the bunker bulkhead. The cooling fans operate at a fixed high speed until the temperature of the air in contact with the thermostat (located in the bunker bypass ducts) has been lowered to the thermostat setting. In one system the cooling fans are then stopped by the controls and the solenoid op erated dampers in front of each cooling fan close auto matically to prevent the flow of air through the bunkers by convection. When the temperature of the return air-rises to the thermostat setting, the controls open the dampers and restart the fans. In the other system when the thermostat has been satisfied, a relay directs the generator power for the cooling fans through energy absorbing resistors to decrease the speed of the fans. At the reduced speed the fans merely ' counterbalance the tendency for flow through the bunkers by natural convection. The thermostat control range is from 30 to 70 F, and a special switch is provided for reversing the cooling cycle operation of the fans described above for heater service. Included in these cars is a tube or pipe located on each tide of the car near the roof at the bunker end for convenience in the introduction of gas for such commodities as grapes and honeydew melons.
All mechanical refrigerator cars are equipped with air cir. culating fans which are usually mounted above the evaporator
coil in the bulkhead between the machinery compartment and the loading area. Nearly all are of the backward-curved cen trifugal type and draw air from the floor through the evapora tor coil and discharge it into the railing distribution duct. The fans consist of two or three blowers mounted directly on the. electric motor shaft or on a separate belt-driven shaft. The fans usually deliver about 4000 cfm and require a 1 hp, 220 volt motor; although, larger capacity fans and motors have also been used.
The condenser fans and engine radiator .cooling fans in mechanical cars are of the propeller type and are usually located on opposite sides of the machinery compartment adjacent to the side louvers. Outdoor air is usually drawn across the condenser coil and into tire machinery compart ment by the condenser fan. A portion of this heated air is used for combustion in the engine and .the balance is ex hausted by the engine radiator fan. Condenser fans are usu ally of 24 to 25 in. diameter, deliver about 8000 cfm, and require a 2 bp, 220 volt motor. The engine radiator fan is usually belt-driven from the engine crankshaft. Some mechanical cars have a horizontally mounted condenser and engine radiator which are incorporated in a tingle frame, are" located at the ceiling of the machinery compartment, and use a 5 hp, 220 volt, motor-driven propeller fan which dis charges the air through louvers in the roof of the car.
Heaters arid Heater Fuels
The use of portable heaters to protect commodities moving in refrigerator cars duriog the winter months began about