Document g2LxzLrR5Kg5qY68VVn6a25pN
fesanto
PROM t NAM E ft LOCAIiONl
//____ ( fin oh
,D. D. Mickelson Krummrich
DATE : February 22, 1972
SUBJECT
:
PCB's In ACL
REFERENCE
TO :
.. .
E. L. Moore General Offices -
fee,
fc
cc= E. R. Billen F. M. Regula
R. M. Blowers G. L. Bratsch H. J. Horner G. A. Hippe D. L. Weber J. J. Zeman - G. 0. W. B. Papageorge - G.O. G. D. Nelson - G.O.
The Krummrich Plant AR&D Group has completed their study of PCB's in Monsanto-manufactured ACL's and in purchased ACL's (FMC's CDB products). This was precipitated by an article ' published in the newspapers in October 1971 In which two University of Wisconsin researchers found PCB's in machine dishwashing compounds produced by Economics Labs (Electrosol and Finish). Since ACL and CDB are used as the disinfectants in these, they were suspect.
The WGK ACL plant used PCB's (Pydraul A-200) principally in the hydraulic systems of the two Krupp centrifuges and the compactor In late 1970, the decision, was made to seek an acceptable substitute for* Pydraul A-200 In ACL. The substitute found was Pydraul A-200-B (a terphenyl). The changeout was done as follows:
South Centrifuge - February 1971
North Centrifuge - Early April 1071
Compactor
- Early April 1971
' The systems were not completely drained on changeout and a residual level of lfi to 5^ PCB was left in the system. Further changeouts and fluid loss replacement have diluted any PCB's in these systems to essentially zero.
The results obtained by the WGK lab are as follows:
Date Produced
Grade
Granulation Lot No.
PCB Level (pob)
ACL
1970, March ' 1970, March
ACL-5 ACL-59
R KM-JJ R KM-60
78 1
PCB (Pydraul A-200) Replaced with PCT (Pydraul A-2C0-B)
x
DSW 295956
STLCOPCB4065900
E. L. Moore PCB's in ACL
Page 2
2/22/72
WGK
1
Date Produced
Grade
Granulation Lot No.
PCB Level (ppb) _
ACL (cont'd.)
1971, .May 6
1971, May 19 1971, July 21
1971, Aug. 6
1971, Dec. 27 1971, Dec. 27
1971, Dec. 30
ACL-66' ACL-66 ACL-66 ACL-66
ACL-85
ACL-85
ACL-85
*
Crude CYA (ACL Haw Material)
1972, Jan. 20 Crude CYA
XG
R R
XG
R
XG
R
\
--
KA-4563 KA-312Q KA-3130 KA-4617 KA-5410
--. KA-5412
__
6l* 6 1
Q
5
1
5
2
FMC - CDB
FMC Lot
1971, Oct. 1971, Oct. 1971, Oct.
ACL-60
ACL-59 ACL-60
G
128482
Interference**
XG
129601
Interference**
XG
130307
Interference**
During the time this lot was produced., two totes of old ACL-66
Powder (produced prior to Pydraul changeout) were being reworked
thru*the compactor. This is the most probable reason PC3 level
is high, i.e. rework contained a high level of PCS which appeared
in the new finished compacted product.
Analyses were made by an adaptation of the basic PCB method. In
v the three FMC samples, the plant was unable to determine if PCB's
were present because the FMC samples contained substances that
interfered with our method of detection.
.
The test run by our lab is accurate down to 3 ppb. The "back ground" level of PCB's is in the 0-3 ppb range and can cause some problems in interpreting lower results.
CONCLUSIONS
.
1. Since the change to Pydraul A-200-B, the PCB level in Monsanto ACL has dropped significantly and docs not appear to be a problem. No further work is planned since Monsanto's ACL appears to be acceptable on PCB level.
2. FMC-produced A'CL contains some substance (undetermined) which interferes with PCB determination -- we do not know if FMC-ACL contains PCB's or how much.
x'
DSW 295957
STLCOPCB4065901
E. L. Moore PCB's in ACL
Page 3 2/22/72 WGK
CONCLUSIONS (Cont'd.)
'
3. The research people at Wisconsin may have been misled by this interference to believe that machine dishwashing compounds (with FMC-ACL) contained PCB's.
bp
\
ckelson
(
1
DSW 295958
STLCOPCB4065902