o< American Standard Inc.
trade price book for
AMERICAN-STANDARD
Hydronic Heating Equipment*
'Hvdroruc* . the science of heating and cooling with water.
PRODUCTS
Boilers--Cast Iron Electric Packaged Boilers Gas-Packaged Units Non-Pkg Boilers Modular Boilers Miscellaneous Options Tankless Water Heaters Oil-Packaged Units Non-Pkg. Boiler Burner Units Boilers Only Miscellaneous Options Tankless Water Heaters Combustion Chambers (A-5) Pressure Fired Boiler Burner Units Oil Gas Gas/Oil Comb. Miscellaneous Options Tankless Water Heaters
Oil Burners and Controls
Zone Valves
Hydronic Assembling Tools
Non-Ferrous Radiation Baseboard Panels--Heatrim Convector--Multifin Cabinets
General Information
Repair Parts Relerence
Terms
PAGE
36 2-5, 9 6-8. 13. 14 10-13 15-18 16-17 19-20 21.31 22. 32 23 23. 30 32
24, 26 28 29 25, 27 25.30
33. 34
33
35
37-40 41, 43 42, 44
45
45
43
HH-75-1
January 1,1975
Cast Iron Boilers Non-Ferrous Radiation
15644
PACKAGED BOILERS GAS FIRED WATER
rs\ AMERICAN
LS STANDARD
HYORONIC HEATING
GPM(X) PACKAGED GAS BOILERS
Completely assembled, pre-wued and jacketed. Regularly supplied for 115 volt 60 cycle power .-i.upiv with '24 volt system or
self energizing controls at no extra charge, i Specify controls desired I Ruilt-in purge valve. Built-in air separator (patented "Eliminaire") Intermittent circulator operation. Design certified by A.G.A. for combustible floor and c loset installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for propane gas--optional for natural gas at
109c reduction of rating as indicated by model number suffix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2.1100 feet.
WATER -- for natural gas -- 100% shut-off
--
'
packaged boiler
number
A.G.A.
input Mbh
A.G.A. output
Mbh
net
l=B=R rating
Mbh
GPM(X)-3 GPM(X)-4 GPM(X)-5 GPM(X)-6 GPM(X)-7
GPM(X)-8
66 99 132 165 198
231
52.8 79.2 105.6 132.0 158.4
184.8
46.1 68.7 92.2 114.8 137 4
160.9
WATER -- for propane gas -- 100% shut-off
GPM(X)-3R GPM(X)-4R GPM(X)-5R GPM(X)-6R GPM(X)-7R GPM(X)-8R
60 90 120 150 180 210
48 41.7 72 62.6 96 83.5 120 104.3 144 125.2 168 146.1
net rating aq. ft. water
307 458 615 765 916 1073
278 417 557 695 835 974
Trad e Price*
with standaf d equipment
GPM(X)
GPM
with lest
axpanaion tank
expansion tank
$418.00 457.00 521.00 595.00 668.00
740.00
$386.00 427.00 493.00 567.00 640.00
713.00
approx. shipping waight
201 244 288 341 387 434
418.00 457.00 521.00 595.00 668.00 740.00
386.00 427.00 493.00 567.00 640.00 713.00
201 244
288 341
387 434
Ordering Examples: 1. Packaged boiler with standard equipment: 1 GPMX-6 boiler with 24 volt controls Nat. gas, 1000 Btu, .6 sg.
2. Packaged boiler with optional equipment: 1 GPMX-7R boiler with 24 volt controls for constant circulator operation. Nat. gas. 1000 Btu. .6 sg. 1 conversion kit frdm natural to propane gai.
3. Packoged boiler with stondord equipment-. 1 GPMX-4R boiler with 24 volt controls Propane gas. 2500 Btu. 1.53 sg.
Standard Equipment
V800 series manifold gas valve Draft Hood
Expansion Tank
114" Circulator with Piping
Wiring Harness
Auto Air Vent
ASME relief valve, 30 lb.
Automatic Fill Valve Dtain vake
Specify 24 Volt . . . or . . . Specify Self Energizing
T822D thermostat
T822D thermostat
L4080D limit control
L8148G limit and eneuiatoi leiav <l"V\i
R8226R transformer (40VA)
and circulator relay
Optional Equipment
Constant circulation (24 V) L4081B limit and teveise acting cnrulat-M contiols with AT20D transformer. Fuinished at no additional cha c*'
Constant circulation (S.E.) L4081B limit and reverse acting cnculatm control and TS822A theimostat. Furnished at no additional rhaiu--
Conversion Kits: Boilers must be specified with suffix lettei R. Redi...... propane latings apply.
Natural to Piopanegas............................................ Trade Price $8.80 Propane to Natutal gas.................................................... * Trade Price $8.80
Zone .valve packages are available for water boiler* For detail.- and prices, see page 33.
15645
HH-75-1
^ See page 48
` : r ;- s
Page 2
AMERICAN Si STANDARD
HYDRONIC HEATING
PACKAGED BOILERS GAS FIRED WATER
G-2 PACKAGED GAS BOILERS
Completely assembled--pre-wired--controls for forced circulation--del'iv ;ark"t. Available with or without tankless heater for domestic hot water. Built-in air separator < patented "Eliniinaire"). 3d lbs. water working pressure. Regularly furnished for 115 volt, 60 cycle with 24 volt control system. Listed rating for installations at sea level to 2,000 feet.
WATER--for nqturol and propane gases--100% shut-off
packaged boiler
number
A.G.A.
input Mbh
A.G.A.
output Mbh
tankless heater number
A l=W=H rating
net
l=B=R rating Mbh
net rating
sq ft water
Trade Price with standard
equipment
approx. shipping
weight
Packaged boilers with factory installed tankless heater
G-24-DPT G-25DPT G-26-DPT G-27DPT
90 120 150 180
72 96 120 144
218 222 222 222
2 Vi 3
3 Vi 3`/2
62.6 83.5 104.3 125.2
417 556 695 834
$628.00 702.00 771.00 835.00
Packaged boilers less heater
G-23-DP G-24-DP G-25-DP G-26-DP G-27-DP
60 90 120 150 180
48 72 96 120 144
41 7 62 6 83 5 104.3 125 2
278 417 556 695 834
494.00 581.00 650.00 733.00 783.00
A Gallons o< water per m nute healed from 40F 13 14QF w th 2OOF do ne'- water tem perature
416 481 551 620
333 403 472 542 603
Ordering Examples: 1. Packaged boiler less heater with standard equipment. 1 G-24-DP boiler Nat gas, 1000 Btu, .6 sg. 2 Packaged boiler with factory installed heater with optional equipment. 1 G-26-DPT boiler with ribbon burners and Nat. to Propane conversion kit. Na` gas. 1000 Btu. 6 sg. 3 Packaged boiler with standard equipment 1 G-25 DP boiler with ribbon burners Propane gas. 2500 Btu. 1 53 sg
See page 48
Standard equipment
V8<)<) Series manifold gas valve
ll* " Circulator with piping ASME relief valve Draft hood (for G-23 only, shipped
in separate carton)
Pressure and temperature uaiiLm Wiring harness AT20D transformer (24V, less
heater boilers only)
Additional standard equipment for boilers with heater
Tankless heater as listed above T822D (24V.) thermostat L8124E (24V.) or L8124B (S.E.) triple Aquastat relay
Additional standard equipment for boilers less heater
T822D (24V ) or TS822A (S.E.) thermostat L4081B i 24 V. and S.E. 1 combination high limit and cn culatoi conti n!
Optional equipment
Self-energizing controls with VS82n gas valve, available when spe< u
on order ..................................................................................
no cii.i'c
L8118E (24V.) or L8118G (S.E.I combination limit lelay
nochaiuo
Natural to Propane gas convei mom kits. Oidei bnilei 'with i::u.... bui tiers" and "Natui al to Propane convei sum kit":
G-23 thiu G-27....................................................................... V Trade Price $7.65
Flooi shield for combustible flooitng. Add .-urtix letti-i
number
....
I....... add $4 45
Note: Manual opening featute is furnished with -elf-enei mzing r .. as li.-ted above. Zone valve packages aie available foi watei bodei- Fm detailpi ice-, -ee page 33.
15646
.. -
Page 3
C v 3' zz 3 .
C
PACKAGED BOILERS GAS FIRED STEAM
d AMERICAN STANDARD
HYDRONIC HEATING
G-2 PACKAGED GAS BOILERS
Completely assembled--pre-wired--controls for steam spplication-- flush or deluxe jacket.
Regularly furnished for 115 volt, 60 cycle with 24 volt control system. Listed ratings for installations at sea level to 2,000 feet.
STEAM--for natural and propane gases--100% shut-off
packaged
boiler number
A.G.A.
input Mbh
A.G.A.
output Mbh
not IsBsR rating
Mbh
tq ft
G-23-SP* G-24-SP* G-25-SP* G-26-SP* G-27-SP*
60 90 120 150 180
48 72 96 120 144
36 54 72 90 108
Add suffu letter "F" for flush or "D" for deluxe jacket
150 225 300 375 450
Trado Prico with standard equipment
flush Jackat
deluxe Jacket
$414.00 503.00 578.00 649.00 711.00
$436.00 524.00 600.00 669.00 733.00
approx. shipping
weight
310 376 443
518 581
15647
Standard equipment
V800 Series manifold gas valve No. 67-GAR (24V. and S.E.) low
water cut-off Gauge glass with trim Draft hood (for G-23-D and G-23-F
thru G-27-F,shipped in separate carton)
T822D (24V.) or TS822A (S.E.) thermostat
PA404A (24V. and S.E.) pressure limit control
AT20D transformer (except S.E.i AS ME safety valve Steam gauge
Ordering Examples:
1. Packaged boiler with standard equipment: 1 G-26-SP0 boiler Nat. gas, 1000 Btu, .6 sg.
2 Packaged boiler with optional equipment: 1 G-24-SPD boiler with self-energizing controls Nat. gas, 1000 Btu, .6 sg.
3 Packaged boiler with standard equipment: 1 G-27-SPD boiler with ribbon burners Propane gas, 2500 Btu, 1,53 sg.
Optional equipment
Self-energizing controls (with VS820 gas valve) .......................... no charge Floor shield for combustible flooring ................................................. add $4.45 Natural to Propane gas conversion kits. Order boiler "with iibb.m burners" and "Natural to Propane conversion kit":
G-23 thru G-27 ........................................................ Trade Price $7.65
Note: Manual opening feature is furnished with self-energizing contmias listed above. For Additional Optional Equipment, See page 15 & 16. For substitution of No. 47-2 low water cut-off and feeder combinat.mi specify on order and add .................................................................................. $56.00
HH-75-1 See page 48
Page 4
Por compete scectficaiions re'er to Technical Catalog Bulletin Form No 7*8-2 'Bev 5 74)
d AMERICAN STANDARD
HYDRONIC HEATING
PACKAGED BOILERS GAS FIRED WATER
G-2 PACKAGED ALL-PURPOSE GAS BOILERS
Completely assembled--pre-wired--for forced circulation or gravity installation--deluxe jacket.
Built-in air separator (patented "Eliminaire"). 30 lbs. water working pressure. Regularly furnished for 115 volt, 60 cycle, with 24 volt control system. Listed ratings for installations at sea level to 2,000 feet.
WATER--for natural and propane gases--100% shut-off
packaged bailor
number
A.QJk.
input Mbh
A.Q.A. output Mbh
not lasBaR rating
Mbh
not rating sq ft watar
G-23-DPG G-24-DPG G-2S-DPG G-26-DPG G-27-DPG
60 90 120 150 180
48 72 96 120 144
41.7 62.6 83.5 104.3 125.2
278 417 556 695 834
Trad# Price with
standard oquipmant Iota thermostat
$362.00
451.00
530.00
603.00
666.00
approx. Shipping woight
307 373 438
511 574
15648
Standard equipment
V800 Series manifold gas valve L4080B (24V. and S.E.) immersion
limit control ASME relief valve
Pressure and temperature gauge AT20D transformer (except S.E.) Draft hood (for G-23-DPG only
shipped in separate carton!
Ordering Examples:
1. Packaged all-purpose boiler with standard
equipment: 1 G-25-0PG boiler Nat. gas, 1000 Btu, .6 sg.
2. Packaged all-purpose boiler with
equipment: 1 G-26-0PG boiler with self-energizing controls Nat. gas, 1040 Btu. .65 sg.
optional
3. Packaged all-purpose boiler with standard equipment: 1 G-24-DPG with ribbon burners Propane gas. 2500 Btu, 1.53 sg.
Optional equipment
Self-energizing controls (with VS820 Series gas valve I available when specified on order ........................................................................................ nochaige Natural to Propane gas conversion kits. Order boiler with "ribbon burners" and "Natural to Propane conversion kit'':..Y Trade Price S7.65
Note: Manual opening feature is furnished with self-enei gizing conti oU as listed above. Thermostats for 24V. and S.E. control systems are available. For model and prices, see page 34. Zone valve packages for water boilers. For details and pi ices, see pace 33. Floor shield for combustible flooring ............................. Tiade Price $4.45
See page 48
por cob'ce'e sceo' ca'-ons
'z
Page 5
cai Caia'og Bui'e' ,n C0rrr, NO 718-2 1 Rev 5 74i
HH-75-1
NON-PACKAGED BOILERS GAS FIRED WATER AND STEAM
rsi AMERICAN ksJ STANDARD
HYDRONIC HEATING
G-2 NON-PACKAGED ALL-PURPOSE GAS BOILERS
Sections assembled--for Water with or without tankless heaters for domestic hot water. Steam without tankless coil.
Flush or deluxe jacket. 30 lbs. water, 15 lbs. steam working pressure.
Regularly furnished for 115 volt, 60 cycle, with 24 volts control system. Listed ratings for installation at sea level to 2,000 feet.
WATER--Natural and Propane Gases--100% shut-off. (Available with factory installed Tankless heater, see options, page 16>
boiler number
A.GA. input Mbh
A.GA.
output Mbh
not l=B=R
ratine
Mbh
not rating sp ft wator
** Tradt Prico with standard equipment
loss thonmostat
flush Jacket
doluxo jackot
approx.
Shipping w.lght
G-23-*W G-24-*W(T) G-25-*W(T)
G-26-*W(T) G-27-*W(Tj G-28-*W(T)
G-29-*W(T) G-210-*W(t) G-211-*W(T)
60 90 120
150 180 210
240 270 300
48 72 96
120 144 168
192 216 240
41.7 62.6 83.5
104.3 125.2 146.1
167.0 187.8 208.7
278 417 556
695 834 974
1113 1252 1391
$327.00 414.00 494.00
567.00 628.00 701.00
772.60 835.00 906.00
$349.00 436.00 516.00
589.00 650.00 723.00
794.00 857.00 928.00
'Substitute letter "F" for flush or "D" for deluxe jacket. Suffix "T" denotes forced circulation boiler equipped with factory installed tankless heater (see page 15 for added charge )
295 353 426
500 566 630
699 790 863
STEAM--Natural and Propane Gases--100% shut-off.
G-23-*S G-24-*S G-25-*S
G-26-*S G-27-*S G-28-*S
G-29-*S G-210-*S G-211-*S
60 90 120
150 180 210
240 270 300
48 72 96
120 144 168
192 216 240
36 54 72
90 108 126
144 162 180
*Substituta letter "F" for flush or "O*' for deluxe jacket.
150 225 300
375 450 525
600 675 750
$385.00 472.00 552.00
625.00 686.00 759.00
831.00 893.00 965.00
$407.00 494.00 574.00
647.00 708.00 781.00
853.00 915.00 987.00
310 368 442
517 583 648
718 809 883
0
Ordering Examples.1. Non-packaged all-purpose water boiler with standard equipment and flush jacket.1 G-27-FW boiler Nat. gas, 1000 Btu, .6 sg. 2. Non-packaged all-purpose water boiler with optional equipment and deluxe jacket: 1 G-210-DWT boiler with (1) No. 232 tankless heater installed Nat. gas, 1000 Btu, 6 sg. 3. Non-packaged all-purpose steam boiler with standard equipment and flush jacket: 1 G-25-FS boiler with ribbon burners Propane gas, 2500 Btu, 1.53 sg.
Standard equipment
V800 Series manifold gas valve AT20D Transformer (except S.E.) Drain valve
Draft hood (for G-23D and all flush jacketed boilers, shipped in separate carton)
Additional standard equipment
Water boilers
ASME relief valve Pressure and temperature gauge L4080 (24V. and S.E.) Aquastat
limit control
Steam boilers
ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure
limit control No. 67-GAR (24V. and S.E.) low
water cut-off Gauge glass with trimmings
Optional equipment
Side outlet ASME steam safety valve available--no charge if specified. Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit":
G-23 thru G-27 ..................................................................... Trade Prices 7.65 G-28 thru G-211 ...................................................................Trade Price $10.30 Floor shield for combustible flooring ................................... Trade Price S 4.45 Additional optional equipment--see pages 15, 16 & 18. Thermostats--see page 34.
Note: Zone valve packages for water boilers. For details and prices, see page 33.
HH-75-1 See page 48
Page 6
For comoieie specifications refer to Technical Catalog Bulletin Form No 710-2 (Rev 5 7*1
15649
IAMERICAN kSJ STANDARD
HYDRONIC HEATING
NON-PACKAGED BOILERS GAS FIRED WATER
G-40 GAS BOILERS--WATER
Deluxe jacket with built-in draft hood. Regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system
(self energizing optional). 50 lbs. water working pressure. Listed ratings for installation at sea level to 2,000 feet.
WATER--For Natural and Propane Gases--100% Shut-Off. For Built-In Water Heaters, see page 16.
boiler number
G-403-W G-404-W G-405-W
G-406-W G-407-W G-408-W
G-409-W G-4010-W G-4011-W
G-4012-W G-4013-W G-4014-W
A.Q.A. input Mbh
150 225 300
375 450 525
600 675 750
825 900 975
A.Q.A. output
Mbh
120 180 240
300 360 420
480 540 600
660 720 780
net l=B=R
rating Mbh
104.3 156.5 208.7
260.9 313.0 365.8
417.4 469.6 521.8
574.0 626.2 678.4
net rating *q. ft. water
695 1043 1391
1739 2086 2434
2782 3130 3479
3827 4175 4523
Trade Price with
atandard equipment leaa thermostat
$ 543.00 691.00 837.00
992.00 1147.00 1265.00
1412.00 1559.00 1707.00
1859.00 2006.00 2153.00
approx. shipping weight
744 921 1117
1297 1475 1647
1820 1994 2195
2364 2533 2702
chimney eixe
inaide dlam. in.
height fact
8 15 8 15 8 15
10 15 10 15 10 15
10 15 12 15 12 15
12 15 12 15 15 15
NOTE: Available as factory assembled sections in all sizes
Trade Price per section $11.00
Standard equipment
V800A Combination Gas Valve: G-403 and G-404 for Natural Gas V800B Combination Gas Valve: G-403 thru G-407 for Propane Gas G-S0AAG Combination Gas Valve: G-405 and G-406 for Natural Gas V88A or B-50 Diaphragm Gas Valve: G-407 thru G-4014 for Natural Gas
G-408 thru G-4014 for Propane Gas
Gas pressure regulator (except propane gas)
Manual main gas shut-off valve -- AT20D Transformer (except S.E.)
Manual pilot gas shut-off valve where diaphragm gas valve is standard.
L62GB (24V.) or CS591A (S.E.) combination pilot switch and valve with auxiliary pilot valves (100% shut-off)
Drain valve -- Water heater opening cover plates
ASME relief valve
Pressure and temperature gauge
L4006A (24V. and S.E.) immersion limit control t
Zone valve packages are available for water boilers. For details and prices, see page 33.
Thermostats--see page 34.
Ordering Example:
Water boiler with standard equipment: 1 G406-W boiler Nat. gas, 1000 Btu, .6 sg.
Other optional equipment (See pages 15, 16 and 18)
15650
See page 48
Page 7
For complete specifications refer to Technical Catalog Bulletin Form No. 728-2 (flev. 2 2'71)
HH-75-1
NON-PACKAGED BOILERS GAS FIRED STEAM
^AMERICAN IS STANDARD
HYDRONIC HEATING
G-40 GAS BOILERS--STEAM
Deluxe jacket with built-in draft hood. Regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system
(self energizing optional). 15 lbs. steam working pressure. Listed ratings for installation at sea level to 2,000 feet.
STEAM--For Natural and Propane Gases--100% Shut-Off. For Built-In Water Heaters, see page 16.
bofltr number
G-403-S G-404-S G-405-S
G-406-S G-407-S G-408-S
G-409-S G-4010-S G-4011-S
G-4012-S G-4013-S G-4014-S
A.Q.A. input Mbh
150 225 300
375 450 525
600 675 750
825 900 975
A.Q.A. output
Mbh
120 180 240
300 360 420
480 540 600
660 720 780
not 1=8= R rating
Mbh
q. ft.
90.0 135.0 180.0
225.1 270.1 315.1
360.1 405.1 450.0
495.2 540.0 585.1
375 563 750
938 1125 1313
1500 1688 1875
2063 2250 2438
Trada Prtca with
tandard aquipmant Im tharmoatat
$ 603.00 750.00 897.00
1052.00 1207.00 1324.00
1472.00 1618.00 1767.00
1918.00 2066.00 2212.00
approx. hipping wafght
744 921 1117
1297 1475 1647
1820 1994 2219
2388 2557 2726
ehimnay tisa
fnaida diam. In.
haight faat
8 15 8 15 8 15
10 15 10 15 10 15
10 15 12 15 12 15
12 15 12 15 15 15
NOTE: Available as factory assembled sections in all sizes
Trade Price per section $11.00
Standard equipment
V800A Combination Gas Valve: G-403 and G-404 for Natural Gas V800B Combination Gas Valve: G-403 thru G-407 for Propane Gas G-S0AAG Combination Gas Valve: G-405 and G-406 for Natural Gas V88A or B-50 Diaphragm Gas Valve: G-407 thru G-4014 for Natural Gas
G-408 thru G-4014 for Propane Gas Gas pressure regulator (except propane gas)
Manual main gas shut-off valve -- AT20D Transformer (except S.E.) Manual pilot gas shut-off valve where diaphragm gas valve is standard. L62GB (24V.) or CS591A (S.E.) combination pilot switch and valve
with auxiliary pilot valves (100% shut-off) Drain valve -- Water heater opening cover plates ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure limit control Gauge glass with trim No. 67-GAR (24V. and S.E.) low water cut-off Side outlet ASME steam safety valve available. No charge if specified. Thermostats--see page 34.
Ordering Example-.
Steam boiler with optional equipment: 1 G-409-ST 1 No. 226 tankless heater with controls Nat gas, 1000 Btu, .6 sg.
Other optional equipment (See pages 15, 16 and 18)
HH-75-1 See page 48
Page 8
For compleie specifications refer lo Technical Catalog Bulletin Form No 728-2 (Rev 2 2 71)
15651
ra AMERICAN LSJstandard
HYDRONIC HEATING
PACKAGED BOILERS GAS FIRED
WATER ONLY
GWP PACKAGED GAS BOILER
(Single Boiler Installation)
Completely assembled--pre-wired--forced circulation only--jacketed. Relief valve, temperature pressure gauge--draft hood included but shipped separately. 50 lbs. working pressure. Built-in air separator (patented "Eliminaire"). Regularly furnished for 115 volt, 60 cycle with 24 volt control system. Listed ratings for installations at sea level to 2,000 feet.
WATER--100% shut-off--Natural and Propane Gas
pockoged boiler
number* GWP-5 GWP-6 GWP-7
A G A. input Mbh 264 330 396
AG.A output Mbh 211.2 264 0 316.8
net 1=1=1
Mbh 183.5 229.6 275.7
chimney tue
Initde dio. in.
height feet
7 15
8 15
8 15
opprev. hipping weight
613 716 823
Trade Price with
itandord equipmen. Iei rhermottot $580.00 701.00 835.00
Standard equipment
Combination automatic gas valve Gas pressure regulator
(except propane) Manual main gas shut-off valve Manual pilot gas shut-off valve AT-20D transformer (except S.E.) Pilot Valve & Switch Drain Valve ASME Relief Valve
Pressure-Temperature Gauge
Deluxe Jacket
L4080D Immersion Limit Control
Draft Hood
Drilled Port Burners are standard for natural gas.
Ribbon Burners are standard for propane gas and optional for nat ural gas.
Optional equipment
Self Energizing controls
N'o charge
Zone Valve Packages are available (for details and prices see page33.1
* Add suffix "R" to model number if ribbon burners are desired
Example: GWP-5R
Optional constant circulation (24 volt) L4081B limit and reverse acting circulator controls ........................................................ Add Trade Price $13.85
Electronic Control Panel Systems, see page 18 for prices. For applica tion and details, contact American Standard.
Sections tested for 100 psi working pressure Trade Price add per section $11.00
Thermostats--see page 34.
See page 48
Page 9
For como'ete soeof'Cations refer to Technical Catalog Bulletin Forrn No 70269*2 (Rev 12 70)
15652
HH-75-1
NON-PACKAGED MODULAR GAS FIRED WATER ONLY
AMERICAN Si STANDARD
HYDRONIC HEATING
GWM GAS MODULAR BOILER HOOK-UP (Modular Boiler Installations)
T.v 1ILVM Modular Boiler Hook-up is a combination or multiple of five, siv or seven .'I'./iii nWM boiler modules. Factory assembled sections with burners, eras manifold, and automatic ttas valve mounted. Deluxe jacket, controls and draft hood are shipped separately. The patented "Eliminaire" is standard. Furnished for 115 volt, (id cycle power supply with 21 volt control system. (Selfenergizing controls are not available). Tested and equipped for 50 PSIG woikinp pressure. Indicated ratings are for installation at sea level to 2.000 ft. elevation.
GWM BOILER MODULES - Natural and Propane Gas: 100% Shut-Off.
module boiler number* GWM-5
AG A input Mbh
264
AGA
output Mbh
211 2
net 1 -J= rating
Mbh
183.5
GWM-6
330
264 0
229.6
GWM-7
396
316 8
275.7
appfOK ihtpping
weight! lb*. 629
735
846
Trad* Price with
itandard equipment
let! thermotiat $563.00
684.00
818.00
Ji
Standard equipment
Combination automatic Gas Valve
Gas pressure regulator (except propane)
Manual Main Gas shut-off valve
Manual pilot gas shut-off valve Transformer Relay R8227B Pilot valve and switch Drain Valve ASME Relief Valve(s) as required
Pressure-Temperature Gauge a.required
Deluxe Jacket
L4080D Immersion Limit Control
Draft Hood Drilled Por t B uinets standard
for natural gas.
Ribbon burner? standard for propane gas and optional for natur al gas.
Optional equipment
1. Factory fabricated Water Manifold for Primary/Secondary circulation. Includes interconnecting supply piping (Boiler to manifold). Inter connecting return piping and circulator not included. Trade Price add per module S55.00
2. Factory fabricated Water' Manifold for Parallel Boiler Hook-up In cludes interconnecting supply and return piping (boiler to manifold) Trade Price add per moduteS111-00
3. Electronic Control Panel Systems, see page 18. For application and details, contact American Standard.
4. Sections tested for 100 psi working pressure. ..................................................................... Trade Price add per section $11.00
Thermostats--see page 34.
Add suffix "R" to module boiler' number if ribbon burners are desned Example -- GWM-5R
rl H -' 5 -1 See page 48
: v ^ s
Page 10
* C 2 5 9 - 2 e'2 '!
15653
rjIA MERICAN IS STANDARD
HYORONIC HEATING
NON-PACKAGED MODULAR GAS FIRED
WATER ONLY
GWM GAS MODULAR BOILER HOOK-UP (Modular Boiler Installations) The following :,oi!et' unit-c in <Ir!.000 BTC input increments are achieved with module holier combination*
MODULAR BOILER HOOK-UPS -- Natural and Propane Gas - 100% Shut-Off.
unit number
GWM-528 GWM-S94 GWM-660 GWM-726 GWM-792 GWM-8S8 GWM-924 GWM-990 GWM-1056 GWM-1122 GWM-1188 GWM-1254 GWM-1320 GWM-1386 G WM-1452 GWM-1518 GWM-1584 GWM-1650 GWM-1716 GWM-1782 GWM-1848 GWM-1914 GWM-1980 GWM-2046 GWM-2112 GWM-2178 GWM-2244 GWM-2310 GWM-2376 GWM-2442 GWM-2S08 GWM-2574 GWM-2640
GWM-2706 GWM-2772 GWM-2B38 GWM-2904 GWM-2970 GWM-3036 GWM-3102 GWM-3168 and upward
^ See page 48
modular composition
$ sect
2 1
~
-- --
2 1
-- -- --
1
-- --
_ -- _ -- -
--
-- -- __ --
_ -- _ -- __ --
_
6 it.
i 2
1
--
1
2 3 2
1
--
3 4 3 2
1
--
5
4 3 2
1
5
4 3 2
1
--
5
4 3 2
1
--
5
4 3 2
7 ..cl
_
-
1 2
-
_
--
1
2 3
_
1 2
3 4
-
1 2 3
4 5 1
2 3 4
5 6 2
3 4 5
6 7 3
4 5 6
7 8
gross input Mbh
528 594 660
726 792 858
924 990 1056
1122 1188 1254
1320 1386 1452
1518 1584 1650
1716 1782 1848
1914 1980 2046
2112 2178 2244
2310 2376 2442
2508 2574 2640
2706 2772 2838
2904 2970 3036
3102 3168
grots output
Mbh
422 4 475.2 528 0
580 8 633 6 686.4
739 2 792 0 844.8
897 6 950 4 1003 2
1056.0 1108 8 1161 6
1214,4 1267 2 1320 0
1372.8 1425 6 1478 4
1531 2 1584 0 1636 0
1689 6 1742 4 1795 2
1848.0 1900 8 1953 6
2006 4 2059.2 2112.0
2164 8 2217 6 2270 4
2323 2 2376 0 2428 8
2481 6 2534 4
net output
Mbh
367 0 413.9 459 1
504 3 551.3 596 5
643 5 688 7 733.9
780 9 826 1 873 0
918 3 963 5 1010 4
1055 7 11026 11478
1193.0 1240 0 1285 2
1332.2 1376 4 1422.6
1467 8 1516 5 1561 7
1607 0 1652 2 1697 4
1746 1 1791.3 1836.5
1881.7 1927 0 1975 7
2020.9 2066.1 2111.3
2156.5 2205.2
approx. shipping weight
| Trade Price
with ifandard equipment I let* thermostat
1258 1364 1470
1581 1692 1993
2099 2205 2316
2427 2538 2834
2940 3051 3162
3273 3384 3675
3786 3897 4008
4119 4230 4521
4632 4743 4854
4965 5076 5367
5478 5589 5700
5811 5922 6213
6324 6435 6546
6657 6768
$1107.00 1228.00 1349.00
1483.00 1617.00 1771.00
1892.00 2013.00 2147.00
2281.00 2416.00 2556.00
2677.00 2812.00 2946.00
3080.00 3214.00 3342.00
3496.00 3630.00 3764.00
3898.00 4033.00 4160.00
4294.00 4429.00 4563.00
4697.00 4831.00 4959.00
5093.00 5227.00 5361.00
5496.00 5630.00 5757.00
5892.00 6026.00 6160.00
6294.00 6428.00
Modular Operating Control Package Options
1. Four stage immersion type opeiating contioi. (one required for up to
4 modules)
Trade price add per control $95.00
2. Immersion type operating controls with individual outdoor resets. Tiade price add per module $64.00
3 Eight stage boiler sequencing eonttol panel system with outdoor leset. ! one required for up to 8 modules) Ti ade pi ice add per control $363.00
4 Sections tested for U>0 psi woiking pressure. ......................................................................Trade Price add per section $11.00
Page 11
15654
"1M-
NON-PACKAGED SINGLE OR MODULAR--GAS FIRED WATER ONLY
^AMERICAN LSJstandard
HYORONIC HEATING
GW NON-PACKAGED GAS WATER (Single or Modular Boiler Installations)
The GW non-packaged boiler designed for forced circulation only. Factory assembled sections. Jackets, burners and manifolds shipped separately. Includes relief valve, tem perature-pressure gauge, and draft hood. The patented "Eliminaire" is standard.
Boiler tested and equipped for 50 PSIG working pressure. Furnished for 115 volt. 00 cycle power supply with 24 volt controls. Self-energizing controls available at no addi tional cost.
Ratings shown are for installations at sea level to 2000 ft. elevation.
INDIVIDUAL BOILERS - WATER - 100% shut-off - Natural and Propane Gas
boiior numb*'*
A G A. input
Mbh
A.G A. output
Mbh
chimnoy me
not Initde
Mbh diet. m.
height fool
GW-8
GW-9 GW-10
462 528 594
369 4 422.4
475.2
321.7 367.0 413.9
9 10 10
15 15 15
opproi thippmg weight
938 1052 1177
Trado Pnco with
tlondord equipment leu thomiotiat
$ 903.00 977.00
1051.00
MODULAR BOILERS -- WATER -- 100% shut-off -- Natural and Propane Gas
unit numbor
modulo' competition
8 toct.
9 oct. 10 toct
gi^st inpv' Mbh
groit output Mbh
not output Mbh
GW-924 GW-990
GW-1056 GW-1122
2
--
--
--1 --2--
--1
924 990 1056
1122
739 792 845
898
644 689 734
781
GW-1188 GW-1386 GW-1452 GW-1518
GW-15B4 GW-1650 GW-1716 GW-1782
GW-1848 GW-1914 GW-1980 GW-2046
----
2
3--
2
1
2 --_.
--3--
--2 --
2
---
3
4
--
--
3 1--
2 2 --.
1 3--
1188 1386 1452 1518
1584 1650 1716 1782
1848 1914 1980 2046
950 1108 1162 1214
1267 1320 1373 1426
1478 1531 1584 1637
826 964 1010 1056
1103 1148 1193 1240
1285 1332 1376 1423
approi. thipping woightt
1876 1990 2104 2229
2354 2814 2928 3042
3156 3281 3406 3531
3752 3866 3980 4094
Trade Price with ilondard oquipmtni
loti thormottot
$1806.00 1880.00 1954.00 2027.00
2101.00 2709.00 2783.00 2857.00
2930.00 3004.00 3078.00 3152.00
3612.00 3686.00 3760.00 3834.00
Standard equipment
Combination automatic gas valve
Pressure-Temperature Gauge
Gas pressure regulator (except propane)
Manual gas shut-off valve
Manual pilot gas shut-off valve
L-4080D Immersion Limit Control Deluxe Jacket Draft Hood
AT-20D Transformer (except SE) Pilot Valve and Switch Drain Valve
Drilled Port Burners standard for natural gas.
Ribbon Burners standard for propane gas and optional for
ASME Relief Valve
natural gas.
Optional equipment
Sections tested for 100 psi working pressure.
............................................................................ Trade Price add per section $11 00
Self-energizing controls
.............
no charge
Thermostats--see page 34.
Electronic Control Panel System, see page 18. For application and de tails, contact American Standard.
Modular Operating Control Package Options
1. Four stage immersion type operating control (one required for up to
4 modules)
Trade Price add per control $95.00
2. Immersion type operating controls with individual outdoor resets (one
required for each module).
Trade Price add per module S64.00
3. Eight stage boiler sequencing control package with outdoor reset (one
required for up to 8 modules)
Trade Price add per control $363.00
'Add suffix "R" to model number if ribbon burners are desired. Example: GW-8-R
HH-75-1 See page 48
Page 12 c0, cc'T'c'eie soec'iicanons refer 'O Technical Cjta1 c-? 3ciie'in cc
No *0289-2 (Rev '2 70'
15655
^AMERICAN LSJ STANDARD
HYORONIC HEATING
NON-PACKAGED. GAS FIRED WATER
G-10 GAS BOILERS --
AGA approved inputs 800 MBH to 6400 MBH. Single combustion chamber--jacketed. Available with built-in heaters for storage tank or tankless application. 50 lbs. water working pressure. Integral draft hood rear outlet--optional top outlet--natural gas only (except G-10I0) available at no extra charge. Regularly furnished for 115 volt, 60 cycle power system with 24 volt controls. Listen ratings for installation at sea level to 2,000 feet.
WATER -- Natural Ga* -- 100% Shut-Off. For Built-In Water Heaters, see page 1 7.
boilar number
A.G.A. Input
Mbh
A.G.A. output
Mbh
a net 1 = B = R rating Mbh
IsBsR piping and
pick-up
factor a
PTrada Price
net rating sq. ft. watar
with standard
equipment lest
thermostat
ipproi. shipping
weight
chimney size
inside diam. in.
ht. ft.
G-105-W G-106-W G-107-W
G-108-W G-109-W G-1010-W
G-1011-W G-1012-W G-1013-W
G-101 i-W G-101S-W G-1016-W
G-101 T-W G-1018-W G-1019-W
G-1020-W G-1021-W G-1022-W
G-1023-W G-1024-W G-1025-W
G-1026-W G-1027-W G-1023-W
G-1029-W G-1030-W G-1031-W
G-1032-W G-1033-W
800 1000 1200
1400 1600 1800
2000 2200 2400
2600 2800 3000
3200 3400 3600
3800 4000 4200
4400 4600 4800
5000 5200 5400
5600 5800 6000
6200 6400
640 800 960
1120 1280 1440
1600 1760 1920
2080 2240 2400
2560 2720 2880
3040 3200 3360
3520 3680 3840
4000 4160 4320
4480 4640 4800
4960 5120
556.5 695.7 834.8
973.9 1113.0 1252.2
1391.3 1530.4 1669.6
1808.7 1947.8 2087.0
2226.1 2365.2 2504.3
2643.5 2782.6 2921.7
3060.9 3200.0 3339.1
3478.3 3617.4 3756.5
3895.7 4034.8 4173.9
4313.0 4452.2
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15
3710 4638 5565
6493 7420 8348
9275 10203 11131
12058 12985 13913
14841 15768 16695
17623 18551 19478
20406 21333 22261
23189 24116 25043
25971 26899 27826
28753 29080
$ 1697.00 2067.00 2433.00
2824.00 3156.00 3493.00
3846.00 4293.00 4824.00
5212.00 5539.00 5880.00
6236.00 6611.00 7002.00
7327.00 7717.00 8058.00
8446.00 8803.00 9131.00
9521.00 9893.00 10160.00
10421.00 10826.00 11154.00
11480.00 11822.00
2706 3153 3627
4107 4584 5077
5568 6146 6659
7179 7752 8248
8744 9253 9765
10301 10778 11341
11851 12360 12891
13384 13876 14374
14878 15368 15891
16406 16936
14 14 14
16 16 18
18 20 20
22 22 22
22 24 24
24 26 26
26 26 28
28 28 28
30 30 30
30 30
20 20 20
20 20 20
20 20 20
20 20 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30
a The net l = 8 = R ratings shown are based on the factors shown <n the piping and pickup column American-Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements.
Ordering Examples:
1 Water boilar 1 G-1G13-W boiler Nat gas. 10GQ 8tu. 6 tg
Standard equipment
V88A or B50D gas valve(s) Gas pressure regulator (except
Propane gas) Manual main gas shut-off valve Manual pilot gas shut-off valve AT20D Transformer Ribbon type main burners ASME relief valve
Drain valve Draft hood
L62GB combination pilotstat and H17BA1 pilot valves
Pressure and temperature gauge L4006A immersion limit control Thermostats--see page 34.
Optional equipment 80 lbs. water test--Trade Price per
section ..................................................$11.00 Factory assembled sections thru
G-1011 Trade Price per section $30.00
Other optional equipment:
See pages 15. 17 and 18
G-10 GAS BOILERS -- WATER for Propane Gas
Propane Gas Ratings are determined by reducing the Natural ratings above by 10%. Example: G-105-W A.G.A. input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current Technical Literature Trade Prices, Chimney Sizes and shipping weights remain the same as shown
above.
See page 48
Page 13
Fcr ccmoie'e sceciNcations 'e'ef to Tec^n-cat Ca'a'cg Buiietm FcrrTi No 688-2 :nev 12 '2>
HH-
15656
NON-PACKAGED GAS FIRED STEAM
d AMERICAN STANDARD
HYDRONIC HEATING
G-10 GAS BOILERS
AGA approved inputs 800 MBH to 6400 MBH. Single combustion chamber--jacketed. Available with built-in heaters for storage tank or tankless application. 15 lbs. steam working pressure. Integral draft hood rear outlet--optional top outlet natural gas only (except G-1010) available at no extra charge. Regularly furnished for 115 volt, 60 cycle power system with 24 volt controls. Listed ratings for installations at sea level to 2,000 feet. Factory sections assembled thru G-1011 optional nod Trade Frice $23.00 per section.
STEAM -- For Natural Ga$ -- 100% Shut-Off. For Built-In Water Heaters (G-10SS thru G-10I4S only) See page! 7.
boiler number
A.G.A. input
Mbh
A.G.A. output
Mbh
a net 1 = 8 = R rating
Mbh
sq. ft.
1=B=R
piping and pick-up factor a
''Trade Price with standard equipment less
thermostat
approx. shipping
weight
chimney size
inside diam. in.
ht. ft.
G-105-S G-106-S G-107-S
800 1000 1200
640
480.1
2000
1.333 $ 1757.00
2706
14
20
800
600.1
2501
1.333
2126.00
3153
14 20
960
720.2
3001
1.333
2497.00
3627
14
20
G-108-S
1400
1120
840.2
3501
1.333
2B88.00
4107
16
20
G-109-S
1600
1280
962.4
4010
1.330
3226.00
4584
16
20
G-1010-S
1800
1440
1095.1
4563
1.315
3552.00
5077
18
20
G-1011-S
2000
1600
1227.9
5116
1.303
3960.00
5568
18
20
G-1012-S
2200
1760
1361.2
5672
1.293
4422.00
6146
20
20
G-1013-S
2400
1920
1489.5
6206
1.289
4902.00
6659
20
20
G-1014-S
2600
2080
1614.9
6729
1.288
5290.00
7179
22
20
G-1015-S
2800
2240
1739.1
7246
1.288
5617.00
7752
22
20
G-1016-S
3000
2400
1863.4
7764
1.288
5958.00
8248
22
30
G-1017-S
3200
2560
1987.6
8282
1.288
6314.00
8744
22
30
G-1018-S
3400
2720
2111.8
8799
1.288
6749.00
9253
24
30
G-1019-S
3600
2880
2236.0
9317
1.288
7139.00
9765
24
30
G-1020-S
3800
3040
2360.2
9834
1.288
7466.00
10301
24
30
G-1021-S
4000
3200
2484.5
10352
1.288
7853.00
10778
26
30
G-1022-S
4200
3360
2608.7
10870
1.288
8195.00
11341
26
30
G-1023-S
4400
3520
2732.9
11387
1.288
8584.00
11851
26
30
G-1024-S
4600
3680
2857.1
11905
1.288
8942.00
12360
26
30
G-102S-S
4800
3840
2981.4
12422
1.288
9269.00
12891
28
30
G-1026-S
5000 .
4000
3105.6
12940
1.288
9657.00
13384
28
30
G-1027-S
5200
4160
3229.8
13458
1.288
10031.00
13876
28
30
G-1028-S
5400
4320
3354.0
13975
1.288
10295.00
14374
28
30
G-1029-S
5600
4480
3478.3
14493
1.288
10560.00
14878
30
30
G-1030-S
5800
4640
3602.5
15010
1.288
10964.00
15360
30
30
G-1031-S
6000
4800
3726.7
15528
1.288
11292.00
15891
30
30
G-1032-S
6200
4960
3850.9
16046
1.288
11617.00
16406
30
30
G-1033-S
6400
5120
3975.2
16563
1.288
11959.00
16936
30
30
i The net l = 0 = R ratings shown are based on the factors shown m the piping and pickup column American-Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements.
Standard equipment
V88A or B50D gas valve(s) Gas pressure regulator
(except propane gas) Manual main gas shut off valve Manual pilot gas shut-off valve AT20D Transformer AbMt safety valve Steam gauge Ribbon type main burners
Optional equipment
Factory assembled sections thru G-1011 Trade Price per section $30.00
Drain valve Draft hood L62GB combination pilotstat and
H17BA1 pilot valves PA404A pressure limit control Gauge glass with trimmings No. 67AR Low Water cut off Thermostats--see page 34. Side outlet ASME steam safety valve available. No charge if specified.
Other optional equipment:
(See pages 15, 17 and 18).
Ordering Eiamples:
$tm boiler with standard equipment 1 G1Q15 S boiler Nat. gas. 1000 Btu. 65 sg
G-10 GAS BOILERS -- STEAM for Propane Gas
Propane Gas Ratings are determined by reducing the Natural Gas ratings above by 10%. Example G-105-S A.G.A. Input 800 less 10%=720 Mbh Input (' Propane Gas. Detailed Propane Gas ratings are shown in current G-10 Techr Literature. Trade Prices, Chimney Sizes and shipping weights remain the as shown above
HH-75-1 ^ See page 48
Page 14
For complete specifications refer 10 Technical Catalog Bulletin Form No 603*2 (Rev 12 72)
15657
fSI AMERICAN caSTANDARD
HYDRONIC HEATING
miscellaneous options
GAS BOILERS
MISCELLANEOUS OPTIONS -- NON-PACKAGED GAS BOILERS
G-2, G-40 AND G-10 BOILERS:
"IS" Equipment: boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. L4006A im mersion operating control for use in storage tank is re quired and will be furnished when specified on order at extra Trade Price $16.90. This control operates gas valves on boiler electrically as required.
No. 47-2 boiler water feeder and cut-off combination is available instead of the 67-AR with G-2, G-40 and G-105 thru G-108 steam boilers at additional Trade Price .$55.65
Low water cut-offs for water boilers: No. 63 cut-off for water working pressures of 50 lbs., or less. Trade Price .....$57.50
No. 150 cut-off for water working pressures in excess of 50 lbs. available when specified. Trade Price .................... $85.90
Try-cocks and tappings: for steam boiler to meet local code specify on order. Trade Price ............................................ $5.70
G-2 BOILERS: "DW" (Direct Water) equipment: In addition to water boiler standard equipment, page 6, includes pressure gauge. 8u lb. ASME relief valve, L4006A Aquastat for storage tank, tank thermometer, name and rating plate for 80 lbs. water working pressure. Specify boiler with "DW" equipment. Trade Price ...............................................................................$22.20
Floor shield for combustible flooring: Add suffix letter "C" to boiler number. Trade Price ............................................$4.45
G-2 AND G-40 BOILERS:
Self-energizing control: All size G-2 and G-40 for propane gas. All G-2 and G-40 thru G-4010 for natural gas. Equip ment includes: S.E. gas'valve, Q313A Thermopile Gen erator and a L4006 S.E. limit control (water boilers less heater) or an L8124B Triple Aquastat Relay (water boilers with heater) or a PA404A Pressuretrol (steam boilers less heater). For steam boilers with heater L4006A S.E. immersion operating control will be turnished in addition to the Pressuretrol. Furnished at no additional charge when specified on order. Special thermo stat required, for Trade Price, see page 34.
No. 101-24V electric water feeder can be added to the No. 67-GAR low water cut-off regularly furnished with steam boilers to provide low water cut-off and feeder combina tion at additional Trade Price .........................................$75.00
Zone circulator control for water boiler with tankless heat er and combination immersion control-relay: use one T822D $7.70 thermostat and one R845A $22.35 relay for second and/or third zone.
Water flow regulators sized for tankless heater involved will be furnished with heater when specified on order to meet local Utility requirement. Trade Price per heater.......$4.45
G-40 AND G-10 BOILERS:
No. 51-2 boiler water feeder and cut-off available instead of No. 67-AR regularly furnished with G-109 thru G-1033 steam boilers. Trade Price .................................................. $85.00
G-40 BOILERS:
Boilers with Tankless Heaters: water (for foiced circula tion) and steam boilers. Heaters are limited to boiler size.as shown in ratings table on next page. Specify heatei and add suffix "T" to boiler number.
G-10 BOILERS:
Pilot filters for G-10 available at no additional charge when specified on order to meet local utility codes.
G-10 Steam Boiler external water heater tappings in cover plates: maximum size 114". Specify number of cover plates. Trade Price per tapping ....................................... $5.70
G-10 Right End Section Steam Trim Tappings for pressure gauge and water column fittings or for auxiliary conti ols furnished as standard equipment at no additional charge.
Modulating gas valve: the G-10 boiler can be specified with the V4062/5055B gas valve for Hi-Lo-off operation. Valve permits adjustment of the Lo-fire operation down to a minimum of 20% of the boiler input. Operation of the valve should be controlled by a SPST operating control Specify on order and add to the Trade Price of the buiiei with regular equipment. G-105 thru 1018 ....................................................................$218.00 G-1019 thru 1033 ................................................................. $275.00
See page 48
Page 15
15658
HH-
TANKLESS HEATERS-GAS FIRED WATER AND STEAM
AMERICAN ^iSTANDARD
HYDRONIC HEATING
G-2 TANKLESS HEATERS
G-2 NONPACKAGED ALL PURPOSE BOILER: Factory Installed tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation. See table below for I=W = H ratings and applicable boiler size. Specify heater, add suffix "T" to boiler number ar^ "factory installed." Add Trade Price shown.
Ratings
btftlcr number
G-24 G-25 G-26 G-27 G-28 G-29 G-210 G-211
A G A. input Bfu/hr
90,000 120.000 150.000 180.000 210.000 240.000 270.000 300.000
hctr nt
2`/2 -- -- --
-- --
--
--
l = W = M R<tm|
heater 722
heater 226
----
3-- 3'/. -- 312 4 3`.5 a/4 3 V, 4'/4 3'r) 41 \ 3'/r 4>/;
heefer 232
___
-- --
-- --
4'4 4% 5
G-2 PACKAGED AND NON PACKAGED ALL-PURPOSE BOILERS:
Tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation I = W = H tankless heaters can be installed in opening used for gravity tapping flange cover. See table for I = W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below.
heater number
218 222 226 232
Trade Prices factory installed
$55.00 61.00 75.00 87.00
sold separate
$32.00 39.00 53.00 65.00
'L8124E for 24 Volt or L8124B for SE, Triple Aquastat Relay furnished with heater (packed in trim box).
Water flow regulator. Specify on order. Trade Price.... $4.45
G-40 TANKLESS HEATERS -- STEAM OR FORCED WATER BOILERS
Ratings (Gallons per minute*)
Trade Prices
HEATER NO.
HEATER WITH CONTROLS
Water
Steamer
HEATER ONLY Watar or Steam
210
222 22$ 232 445 460
$55,00 61.00 75.00 07.00 105.00 113.00
$48.00 55.00 69.00 81.00 99.00
108.00
$32.00 39.00 53.00 65 00 83.00 91.00
Tankless heaters with controls for water boilers: L812IE
combination immersion control-relay packed in trim box
in place of standard limit control.
$4.45
Tankless heaters with controls for steam boilers: L4006A
immersion operating control packed in trim box in addi
tion to PA404A pressure limit control.
$16.90
Water flow regulator. Specify on order. Added Trade Price ........................................................................................................
(1) Additional L4006A operating control required for steam boiler-heater combinations shown shaded. Add to above heater w/control Trade Price ........................
G-40
F.M. or F.I.A. equipment F.I.A. requires ipeelel gas train PLUS F.I.A. electronic panel
F.M. A F.I.A. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY)
BOILER NUMBER
ADO TO BOILER TRADE PRICE IT
F.M.('I
F.I.A.(*)
G-403 thru G-4014
$112.00
$589.00
111 FM gas control equipment includes two manual shul-ofl valves, a lest vent valve and one AH2/V710 Hydromotor Valve
'1` F I.A, gas control equipmenl includes two manual sfiut-oII valves. HI and to pressure switches, two AH2/V710 Hydromoior Valves and a vent valve
Note: A low water cut-off for water boilers (50 lb. or 80 lb. water working pressure) will be furnished as required.
No. 63 ............................................................. Trade Price $57.50 No. 150 .......................................................... Trade Price $85.90
Boiler
HEATER 218 HEATER 222 HEATER 226 HEATER 232 HEATER 445 HEATER 460 Steam Water Steam Water Steam Water Steam 1Mater Steam Water Steam Water
G-403
3 4--
--
--
--
--
--
--
--
--
G-404
3 V2 4
4 4 Vi -- -- -- -- -- -- --
G-405 G-406 G-407
m ivt
3%
4 4 4
4 4 Vi 5'/i 6
4 4 Vi 5 Vi
6
4 4 Vi
6 6 Vi
----
----
---- ----
7 7 Vi -- --
-- -- --
G-408 G-409 G-4010
G-4011 G-4012 G 4013 G-4014
3% 3 Vi
3% 3A 3 Vi 3 Vi
4 4 4 4 4 4 4
4 4 V3 4 4 xh 4 4 Vi
4 4 Vi 4 4 Vi 4 4 Vi 4 4 Vi
6 6'/i 7 Vi 8 8l/i 9 6 6 Vi 7% 8 8 Vi 9
6 6 Vi 7% 8 8 Vt 9 6 6 Vi 7 VI 8 8V4 9 6 6 Vi 7 Vi 8 8 Vi 9 6 6 Vi 7 Vt 8 8 Vi 9 6 6 Vi 7'h 8 8 Vi 9
-- -- -- 11 12
13 13
*Gtiions of wafer per minute raised trom 40F to 140 F with 200 F boiler water temperature.
_
-- -- -- -- -- -- -- 12 13 14 Vi 15 Vi
HH-75-1 See page 48
Page 16
15659
fjl AMERICAN ISSTANDARD
HYDRONIC HEATING
TANKLESS HEATERS-GAS FIRED WATER AND STEAM
G-10 BOILERS -- TANKLESS OR TANK TYPE HEATER
No. 1023 heater is available in any quantity. Specify number
required. Trade Price each
$45.40
G-10
F.M or F t A. equipment
F l A requires special qas train PLUS F r a e'pci'on.r
The ratings table on this page shows the ratings attained if more than one heater is connected in parallel.
F.M. & F.I.A. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY) AOO TO BOILER TRAOE PRICE V
Copper pipe manifolds, factory assembled for multiple heater parallel hookup, shipped in boxes of 2 manifold assemblies per box, when specified with heaters, are avail able at the following charges:
Manifold Assembly Two Heater Three Heater Four Heater
Trade Price
$9.85
$14.95
$18.75
BOILER NUMBER
G-105 thru G-106 G-107 G-108 thru G-1011 G-1012 thru G-1017 G-1018 G-1019 thru G-1030 G-1031 thru G-1033
F.M.(')
$ 98.00 116.00 101.00 164.00 221.00 229.00 294.00
F.I.A.(')
$591.00 637.00 770.00 878.00 957.00
1019.00 1185.00
All G-10 water boilers and sizes G-105S thru G-1014S steam boilers can be provided with sections for insertion of heaters at no extra charge, add suffix letter T to boiler number and specify the number of sections with heater openings. Cover plates to close unused water heater openings will be furnished only if specified on order at Trade Price each .......................................................................$6.05
When specified, the G-10 water boiler with heater can be provided with the combination L8124E in place of the L4006A limit control. Trade Price ................................$22.00
1,1 PM, gat control equipment includes two manual shut-off valves, a test vent valve and one AH2/V710 Hydromotor Valve
'7' F I A gas control equipment includes two manual shut-off valves, hi and LO pressure switches, two AH2/V710 Hydromoior Valves and a vent valve
When No. 1023 heaters are used in steam boilers, the L4006A operating control will be required for installation in a heater tapping. Trade Price ................................... $16.90
When the No. 1023 heaters are used in a storage type domestic hot water system, the L4000A operating control will be required for insertion in a storage tank. Trade Price .............................................................................................$16.90
NO. 1023 HEATER RATINGS TANKLESS APPLICATION
boiler number
no. of tankless
heaters
intermittent draw
heater rating gpm @ 100 rise
pressure drop (with manifolds)
PSI
G-105- G-1033 G-105 - G-1033
G-106 - G-1033 G-108 - G-1033
1 2 3 4
4%
7>/z 10
12%
NOTE: Heaters for Steam Boilers available S thru 14 sections only.
19 14
12
11
STORAGE TANK APPLICATION
boiler number
number of
heaters
continuous draw
100 rise gpm
recovery capacity 100 rise
gph
boiler output required
mbh
G-105 - G-1033 G-105 - G-1033 G-106 - G-1033 G-108 - G-1033
G-1011 - G-1033 G-1013 - G-1033 G-1014 - G-1033 G-1016 - G-1033
G-1018 - G-1033 G-1020 - G-1033 G-1022 - G-1033 G-1024 - G-1033
1 2 3 4
5 6 7 8
9 10 11 12
4
240
200
7
420
350
10
600
500
13 780 650
16
960
800
19 1,140 950
22
1,320
1,100
25
1,500
1,250
28
1.680
1,400
31
1,860
1,550
34
2,060
1,700
37
2.220
1,850
NOTE: Heaters for Steam Boilers available 5 thru 14 sections only.
storage tank size gala.
500 500 500 1,000
1,000 1,000 1,500 1,500
1,500 2,000 2,000 2,000
See page 48
Page 1 7
15660
HH-75- *
ELECTRONIC CONTROLS
I AMERICAN fia STANDARD
HYORONIC HEATING
GAS BOILER ELECTRONIC CONTROL PANEL SYSTEMS
(FOR 115 voir, to CYCLE > PHASE POWER ONLY)
Panel System EPG-M: Provides manual ignition, 100% safety shut-off with electronic supervision of pilots 1 to 3. Main burners and pilots are turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Baso valves and thermocouples and Q-179B electronic flame rod and pilot; RA890F protectorelay installed on panel; 3 ft. flame rod wire per pilot.
Panel System EPG-ES: Provides electronic supervision of each pilot (1 to 3) and interrupted continuous burning pilot electronically turned off and electrically relighted on every cycle to achieve positive component check of relays and pilot system. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panels with 2-4 seconds response timing and alarm con tacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot.
Panel System EPG-E: Provides electronic supervision of each pilot (1 to 3) and intermittent electric ignition of all pilots. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panel with 2-4 seconds response timing and alarm contacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot.
Panel System EPG-M(FIA): Specifically designed to meet FIA requirements. Provides constant burning manually lighted electronically supervised pilots (1 to 3). 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; alarm bell, alarm silencing switch; purge timer, all factory assembled in master panelRA 890P protectorelay installed in panel; Baso valves and thermocouples and Q-179B electronic flame rod pilot; 3 ft. flame rod wire per pilot.
ADDITIONAL CHARGES-^Trade Price
Specify on order type of system desired, as described above, and add charge for boiler size involved to Trade Price of boiler with regular equipment.
PANEL SYSTEMS EPG-M
boiler no
system no.
added charge (1)
GW, G-40
EPG-M 1
$250.00
G-105 thru G-1012
EPG-M1
250.00
G-1013 thru G-1023
EPG-M2
480.00
G-1024 thru G-1033
EPG-M3
718.00
PANEL SYSTEMS EPG-E
boiler no.
system no.
GW, G-40
EPG-E1
G-105 thru G-1012
EPG-E1
G-1013 thru G-1023
EPG-E2
G-1024 thru G-1033
EPG-E3
added charge (1) $276.00 276.00 508.00 762.00
PANEL SYSTEMS EPG-ES
boiler no.
system no.
added charge (1)
GW, G-40
EPG-ES1
$329.00
G-105 thru G-1012
EPG-ES1
329.00
G-1013 thru G-1023
EPG-ES2
561.00
G-1024 thru G-1033
EPG-E S3
817.00
PANEL SYSTEMS EPG-M(FIA)
boiler no.
system no.
added charge
GW, G-40
EPG-MI(FIA)
$455.00
G-105 thru G-1012
EPG-MI(FIA)
455.00
G-1013 thru G-1023
EPG-M2(FIA)
696.00
G-1024 thru G-1033
EPG-M3(FIA)
946.00
Flame Rod Wire: Trade Price per foot Ignition Cable: Trade Price per foot .
$ .50 $1.05
(') Note: It purge timer is desired, specif/ on order and add $75.00 Trade Price
'Trade prices apply to equipment when shipped with boiler. For field conversions, price on application.
HH-75-1 See page 48
Page 18
15661
d AMERICAN STANDARD
HYDRONIC HEATING
PACKAGED BOILER-BURNER UNITS
WATER ONLY
DP (T)-95/105 PACKAGED BOILER-BURNER UNITS
Boiler-burner unit; dry base design--with DH-F flame retention burner (1725 RPM). Nozzles for two firing rates provided. Furnished with controls for forced circulation. Tested and equipped for 30 lbs. water working pressure. 115/60/1 electrical charac teristics.
WATER
packaged unit
number
grota l=B=R
output mbh
l=8=R burner capacity
gph
tanfclass heater
number
lankleas heater capacity
gpm
net l=8=R
rating
mbit
net reting
sq. ft. water
Trade Price with
standard
equipment
approi. shipping weight
noaale siaes
Packaged units with factory installed lankless heater with R-8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control.
DPT-95
95
.90 218
3
82.6
550 $686.00 496
90-80'S
and
DPT-105 105
1.00
218
3
91.3 608 686.00 496 i.oo-so's
Packaged units less tankless heater with L4080B Aquastat limit control, and separate R8184G light sensing primary control.
95 .90 105 1.00 --
82.6
550 $636.00
-- 91.3 608 636.00
`Gallons of watar par minute from 40*F to 140*F with 200gF boiler water temperature. NOTE. Water volume 9.6 gallons.
481 .90-80'S and
481 1.00-80'S
________
Standard equipment:
Model DH-F Arcoflame oil burner with sling mounting cad cell, bracket and leads. T822D thermostat. Light weight fire brick combustion chamber. Nozzles--Two (high firing and low fir ing rate) each boiler. Draft regulator. ASME relief valve. Pressure and temperature gauge. 1)4" circulator and piping. Wiring harness. Drain valve.
Optional equipment:
Two-stage fuel unit for DH-F oil burn er. Specify on order. Trade Price... $8.30
Ordering Examples:
. Packaged unit with healer with jtondard equipment: I DPT-95 boiler-burner unit
2 Packaged unit lest heater with standard equipment: 1 DP-95 boiler-burner unit
W See page 48
Page 19
For complete specifications refer to Technical Catalog Bulletin Form No. 72131-2 (6'72)
^ i 5662
HH-75-1
PACKAGED BOILER-BURNER UNITS WATER ONLY
fISSJI ASTMAENRDICAARND
HYDRONIC HEATING
VP(T) PACKAGED BOILER-BURNER UNITS
Boiler-burner unit--wet base design--with DH-F flame retention burner (1725 RPM). Nozzles for multiple firing rates provided. Furnished with controls for forced circula tion. Tested and equipped for 30 lbs. water working pressure. 115/60/1 electrical characteristics.
WATER
No. Sections
ptckeged unit
number
groee
output mbh
l=B=R burner eepeclty
ph
Unkl heeler
number
tenkleee heater capacity
flpm
not i=b=r
rating
mbh
not rating
sq. ft. water
Trade Prlco with
tandard equipment
ipproi. hipping weight
wator volume (gal.)
noxsfe iioo
Packaged units with factory installed tankless heater ^`.th R8!,2.D/^"?^fVl7^Thir`ion'ohlgh 'TV low 'imit
*9
ana circulator control, light sensing primary control.
VPT-115
115
1.05 130 3 Vi 100.0 667 $ 737.00 575
15.6
1.00-80 Hago ES
and
3
VPT-130
130
1.15 130
3% 113.0 753
737.00
575
15.6
1.10-80 Hago ES
VPT-140
140
1.25 130 3 Vi 122.0 814 737.00 575
15.6
1.25-80 Hago ES
VPT-170
170
1.50
131
4% 147.8 985
890.00
685
20.0
1.50-80 Hago ES
4 and
VPT-190
190
1.70
131
4V4 U5.2 1102
890.00
685
20.0
1.65-80 Delevan B
VPT-230
230
2.05 132 6
200.0 1333 1004.00 795
24.4
2.00-70 Monarch R
5 and
VPT-2S0
250
2.25 132 6
217.4 1449 1004.00 795
24.4
2.25-70 Monarch R
Packaged unlla leaa tanklesa healer
With R8182F Aquastat-relay combination, limit and circulator control, light sensing primary control, one heater opening cover plate.
VP-115
115 1.05
100.0
667 $ 686.00
560
15.6
1.00-80 Hago ES
and
3
VP-130
130
1.15
--
-- 113.0 753
686.00 560
15.6
1.10-80 Hago ES
VP-140
140 1.25
122.0 814
686.00 575
15.6
1.25-60 Hago ES
VP-170
170
1.50
--
-- 147.8 985
838.00 670
20.0
1 50-80 Hago ES
4 and
VP-190
190
1.70
--
-- 165.2 1102
838.00 670
20.0
1 65-80 Delevan B
VP-230
230
2.05
--
-- 200.0 1333
926.00 780
24.4
2.00-70 Monarch R
5 and
VP-250
250
2.25
--
217.4 1449
926.00 780
24.4
2.25-70 Monarch R
'Gallons ol water par minute from 40*F to 140'F with 200F boiler water temperature.
Standard equipment:
Model DH-F Arcoflame oil burner with sling mounting cad cell, bracket and leads. T822D thermostat. Pre-cast refractory combustion target wall.
Draft regulator. ASME relief valve. Pressure and temperature gauge. 1(4" circulator with piping. Wiring harness. Drain valve.
Ordering Examples: \. Pockoged unit with heoter with stondard equipment: 1 VPT-115 boiter-burner unit 2. Packaged unit less heater with standard equipment: 1 VP-115 boiler-burner unit
Optional equipment:
Zone valve packages are available for water boilers. For details and prices, see page 33. Two stage fuel unit for DH-F oil burn er--specify on order. Trade Price... $8.30 Jacket extension. Trade Price .......$35.00 R-8182-D Aquastat relay combination for use with tankless coils for conver sion of boiler without tankless heater. Trade Price add .................................... $7.70 For tankless heater information, see page 23.
15663
HH-75-1 ^oa pal'd dP
Page 20
For comoie'e soeci'icaticns reter 'o Technical Catalog Bulletin For-n No ?263-2 rRev 8 741
d AMERICAN STANDARD
HYDRONIC HEATING
NON-PACKAGED BOILER-BURNER UNITS
WATER AND STEAM
V-3 NON-PACKAGED ALL-PURPOSE BOILER-BURNER UNITS
Boiler-burner unit--wet base design--with DH-F flame retention burner ( 1725 RPM). Sections assembled--nozzles for two firing rates provided. Flexible for steam, water, forced or gravity circulation--with or without tankless heater. 30 lbs. water working pressure, 15 lbs. steam. 115 volt, 60 cycle, single stage electrical characteristics.
WATER
WBT Forced circulation units with factory installed tankless heater include R8182D aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control.
WB Forced circulation units less heater include R8182F aquastat combination, limit and circulator control, light sensing pri mary control.
Section Designator
bolter burner
unit number
groee l = B=fl
output mbh
l = B=R burner
capacity sph
tan Ideas
heater number
tankless heater
rating
gpm
net l=B=R
rating mbh
r Trada Price Trade Price
net standard itandard
rating equipment equipment
aleam
less
with
sq. ft.
tankless
tankless
appro*. shipping
weight
notile used
V-34 V-36
V3-116WB(T) V3-128WBm
V3-172WB(T) V3-186WBm
V3-228WB(T) V3-244WBIT)
V3-284WB(T) V3-302WB(T)
116 128 172 186 228 244 284
302
1.05 222 4% 1.15 222 4%
1.55 226 5% 1.70 226 5% 2.10 232 7 2.25 232 7 2.60 445 8'/4 2.80 445 8'/4
100.9 111.3 149.6 161.7 198.3 212.2 247.0 262.6
___ $ 613.00 -- 613.00 -- 789.00 -- 789.00 -- 957.00 _ 957.00 -- 1112.00 -- 1112.00
$ 656.00 656.00
846.00 846.00 1026.00 1026.00 1199.00 1199.00
613 613 790
790 967
967 1144 1144
1.00-80" Hago ES 1.10-80 Haao ES 1.50-80" Hago ES
1.65-70" HaaoES 2.00-70 Monarch R 2.25-70 Monarch R 2.50-70" Delevan B 2.75-60" Delevan B
WBG Gravity units less heater includes L4080B aquastat limit control, and separate R8184G light sensing primary control.
V-3b
V3-116WBG V3-128WBG V3-172WBG V3-186WBG V3-228WBG V3-244WBG V3-284WBG V3-302WBG
116 1.05 128 1.15 172 1.55 186 1.70
228 2.10 244 2.25 284 2.6tf 302 2.80
___ -- -- -- -- --
----
____
100.9
___
607.00 Not Avail.
613
1.00-80 Hago ES
-- 111.3 -- 607.00 Not Avail. 613 1.10-80 Haao ES
-- 149.6 -- 783.00 Not Avail. 790 1 50-80" Hago ES
-- 161.7 -- 783.00 Not Avail. 790 1.65-70 Haao ES
-- 198.3 -- 952.00 Not Avail. 967 2.00-70 Monarch R
-- 212.2 -- 952.00 Not Avail. 967 2.25-70 Monarch R
--
247.0
-- 1107.00 Not Avail. 1144
2.50-70 Delevan B
--
262.6
-- 1107.00 Not Avail. 1144
2.75-60 Delevan B
STEAM SBT Steam units with factory installed tankless heater includes PA404A Pressuretrol, L4006A aquastat operating control, and
separate R8184G light sensing primary control. SB Steam units less heater include PA404A Pressuretrol, and separate R8184G light sensing primary control.
V-33
V-35 V-36
V3-116S8(T)
V3-128SB(T! V3-172SB(T) V3-186SB(Ti V3-228SB(T) V3-244SB1T) V3-284SB(T) V3-302SB(T)
116 128
172 186
228 244 284
302
1.05 222 4'/4 1.15 222 4 V* 1.55 226 5 Vi 1.70 226 5 Vi 2.10 232 6 Vi 2.25 232 6 Vi 2.60 445 7 Vi 2.80 445 7 Vi
87.1 363
607.00
96.0 400
607.00
129.1 538
783.00
139.4 581 171.1 713
783.00 952.66
183.1 763
952.00
213.1 888 1107.00
226.6 944 1107.00
548.00 548.00 708.00 708.00 857.00 857.00 1000.00 1000.00
613 613 790 790 967 967 1144 1144
1.00-80 Hago ES 1.10-80 Haao ES 1.50-80 Hago ES 1.65-70 Haao ES 2.00-70 Monarch R 2.25-70 Monarch R 2.50-70 Delevan B 2.75-60 Delevan B
^ Gallons ot water per minute heated from 40F to 140"F with 200*F boiler water temperature.
'W See page 48
Standard equipment:
Model DH-F Aicoflame oil burner sling mounting, cad cell, bracket and leads.
T822D thermostat. Pre-cast refractory combustion target wall.
Draft regulator.
Drain valve.
Units WITH water heater: 1 cover
plate with
control tapping.
Units LESS heater: 2 cover plates for
heater openings.
Water: ASME relief valve. Pressure and temperature gauge.
Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings.
Ordering Examples: 1. All-Purpose boiler-burner unit with standard equipment: For forced circulation, with heater: 1 V3-I16/128WBT boiler-burner unit For gravity circulation: 1 V3-172/ 186WBG boiler-burner unit 2. All-Purpose boiler-burner unit with optional equipment: For forced circulation, less heater: 1 V3-228/244WB boiler-burner unit with stage fuel unit.
Optional equipment:
Zone valve packages are available for water boilers. For details and prices, see page 33. Others--see page 23.
Page 21
For complete speciricaiions refer to Technical Catalog 8ulletin Form No. 73-166-2 16/73)
HH-75-1
15664
NON-PACKAGED OIL FIRED BOILERS WATER AND STEAM
^AMERICAN kSi STANDARD
HYDRONIC HEATING
V-3M ALL-PURPOSE OIL FIRED BOILERS
The non-packaged all-purpose boiler only, with sections factory assembled, tested and equipped for 30 psi working pressure for water, 15 psi steam.
WATER
WT--Forced circulation boiler only with factory installed tankless heater. W--Forced circulation boiler only less heater.
Section Designation
boilar nunrbar
V-33M V-34M V-35M V-36M
V3M-92W(T) V3M-110Wm V3M-138W(T)
V3M-156Wm V3M-184W(T)
V3M-202Wm
V3M-230W(T) V3M-248W(T)
gross )=B=R output
mbh
92 110
138 156 184 202 230 248
l=B=R bumar capacity
gbh
.85 1.00 1.30 1.45 1.70 1.90 2.15 2.35
tankless haatar numbar
222 222 226 226 232 232 445 445
tankless haatar rating gpm
4 4 5 5 6 6 7 7
nat l=B=R
rating mbh
80.0 95.7 120.0 135.7 160.0 175.7 200.9 215.7
Trada Prlca standard equip. lata tanklasa haatar
$327.00 327.00 437.00 437.00 560.00 560.00 664.00 664.00
Trada Prlca standard aquip.
with tankiass haatar
$355.00 355.00 478.00 478.00 610.00 610.00 729.00 729.00
approx. shipping
weight section
assy
613 613
790 790
967 967 1144 1144
STEAM
ST--Steam boiler only with factory installed tankless heater. S--Steam boiler only.
Section Designation
boiler numbar
groaa l=B=R
output mbh
l=B=R
bumar capacity
gbh
tanklasa haatar
numbar
tanklaaa haatar
rating gpm
net is=B=R
rating mbh
net ^ Trade Prlca y? Trade Prlca
l=B=R standard aquip. standard*equip.
sq. ft.
lass tankiass
with tankless
steam
haatar
haatar
V-33M V-34M
V-36M
V3M-92S(T) V3M-110Sm V3M-138S(T) V3M-156Sm V3M-184S(T) V3M-202Sm V3M-230S(T)
V3M-248S(T)
92 110 138 156 184 202 230 248
.85 1.00 1.30 1.45 1.70 1.90 2.15 2.35
222 222 226 226 232 232 445 445
4
69.0
288
4
82.5
344
5 103.5 431
5 117.0 489
6 138.0 575
6 151.5 631
7 173.3 722
7 186.0 775
327.00 437.00 437.00 560.00 560.00 664.00 664.00
355.00
478.00 478.00 610.00 610.00
729.00 729.00
A Gallons of water per minute heated from 40*F to 140TF with 200*F boiler water temperature. Only oil burners capable of developing 10% CO{, such as the OH-5 burner, may be used with V-3M oil fired boilers.
approx. shipping weight section
sss'y
613 613 790 790 967 967 1144 1144
HH-75-1 See page 48
Standard equipment: Pre-cast refractory combustion chamber. Drain valve.
Water: ASME relief valve. Pressure and temperature gauge.
Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings.
Optional equipment: See page 23.
Note: Boilers with factory installed tankless
heater are shipped with one water heater
opening cover plate with
control tap
ping. Boilers less factory installed heatei
are shipped with an additional water heatei
opening cover plate (blank).
Zone valve packages are available for water
boilers. For details and prices, see page 33
Ordering Examples:
1. Water boiler less heater with standard equip ment: 1 V3M-92/110W boiler
2. Steam boiler with heater with standard equip
ment: 1 V3M-138/156ST boiler
3. Water boiler with heater with optional equip ment: 1 V3M-230/248WT boiler with lacket ex tension
Page 22
For complete speciftcalions refer to Technical Catalog Bulletin Form No 73-166-2 (6/73)
15665
d AMERICAN STANDARD
HYDRONIC HEATING
OPTIONAL EQUIPMENT OIL FIRED BOILERS
OPTIONAL EQUIPMENT
VP(T) PACKAGED BOILER-BURNER UNITS V-3 NON-PACKAGED BOILER-BURNER UNITS V-3M NON-PACKAGED BOILER ONLY
JACKET EXTENSIONS
V-3 and V-3M jacket extension provides 17*4" acoustical enclosure in front for concealment of oil burner and con trols--specify on order. Trade Price Add .................. $50.60
LOW WATER CUT-OFF--McDonald & Miller No. 67AR low water fuel cut-off. Trade Price ........................................$43.00
Controls and control sets are shown on page 31.
MISC. V-3 BOILER-BURNER UNITS
Two-stage fuel unit. Trade Price ...................................... $8.30
Order R8182D Aquastat-relay combination to permit use of tankless heater with boiler-burner units furnished less water heater. Trade Price ................................................... $7.70
Order R8182E Aquastat-relay combination to provide room thermostat control of circulator. Trade Price.....$6.00
FOR V-3 ALL-PURPOSE AND VP(T) BOILER-BURNER UNITS
For substitution of No. 4 control set consisting of T822D thermostat, L4081B Aquastat limit and circulator control, plus R8184G light sensing primary control, instead of R8182F combination control, for non-packaged boilerburner units for forced circulation LESS heater. Added Trade Price ............................................................................. $15.30
For substitution of No. 5 control set consisting of T822D thermostat, L8124C Aquastat, limit, reverse and operating control, circulator relay, plus R8184G light sensing pri mary control, instead of R8182D combination control, for non-packaged boiler-burner units for forced circulation WITH tankless heater. Added Trade Price ................ $6.05
The No. 5Z Control Set can be used for circulator zoning with boiler-burner units with tankless heater. 1 No. 5Z set is required for each zone in addition to the first zone which is controlled by the No. 5 Control Set or equivalent. Added Trade Price .................................. ............................ $30.05
TANKLESS HEATERS FOR V-3, V-3M AND VP BOILERS
Heaters can be ordered for separate shipment for use with units or boilers specified less heater as follows:
RATINGS--Gallons of water per minute from 40'F to 140"F with 200"F boiler water temp.
boiler number
HEATER 222 HEATER 226 HEATER 232 HEATER 445 HEATER 130 HEATER 131 HEATER 132 Steam Water Steam Water Steam Water Steam Water Steam Water Steam Water Steam Water
V3-116/128
4V4 4%
V3-172/186
4V4 4%
V3-228/244
41/4 4%
V3-284/302
41/4 4%
V3M-92/110
4 4V2
V3M-138/156
4 41/2
V3M-184/202 4 4V2
V3M-230/248
4 41/2
VP.-115/130/140 -- --
VP-170/190
----
VP-230/250
----
51/4 5% 5V4 5Y4 5V4 5%
5 51/2
5 5V2
5 5 V2
--
--
--
--
----
6 V4 6V4
7 7
6 6% 6 6% ---- ----
----
7V4 8V4
7 7y4
--
--
--
--
----
--
--
----
-- 3V2 -- 3V2 -- 3V2
--
--
-- -- -- --
--
--
4% 4%
--
--
-- --
--
--
--
-- --
6
Note: Because of unique boiler design a second heater may be installed in V3 and V3M water boilers which will increase the intermittent draw rating.
* Appropriate controls must be ordered in addition to heater only above.
Trade Prices
HEATER HEATER ONLY NUMBER Watr A Staam
222 $39.00 226 53.00 232 65.00 445 83.00 130 43.00 131 43.00 132 69.00
See page 48
Page 23
HH-75-1
15666
NON-PACKAGED PRESSURE FIRED BOILER-BURNER UNITS WATER AND STEAM
AMERICAN 5J STANDARD
HYORONIC HEATING
PFA-3 PRESSURE FIRED BOILER-BURNER UNITS
Jarketed--forced draft with ilame retention oil burner. Sealed sections--with or without tankless heaters. 50 lbs. water wo-kitur pressuie. 15 lbs. steam. 115 volt. 00 cycle |N>.ver sunnly.
WATER
beilerburner
number
grots 1 =1=1
Mbh
* 1 = 8=8
(opacity gph
tankless number
IsWsN
rating
net 1 = 8=1
Mbh
net rating sp. ft. water
Trade Price
standard equipment
apprexweight
vent site diam. in.
Forced circulation units with factory Installed tankless neater : No. 5 control set -- T8220 thermostat, L8124CI Aguastat, reverse and operating control, c irculator relay, R8184G light sensing pri mary control.
PFA-34-WT PFA-35-WT PFA-36-WT PFA-37-WT
300 375 450 526
2.65
226
6.0
260.9
1739
$1234.00
3.30
232
7.5 326.1 2174
1396.00
3.95
445
9.0
391.3
2609
1563.00
4.60
445
9.0
457.4
3049
1713.00
905 1096 1287 1481
8 8
8 8
Forced circulation units less heater: No. 4 control set -- T822D thermostat, L4081B Aguastat limit and circulator control. R8184G llgnt sensing primary control.
PFA-34-W PFA-35-W PFA-36-W PFA-37-W
300 2.65 375 3.30 450 3.95 526 4.60
260.9 326.1 391.3 457.4
1739 2174
2609 3049
$1167.00 1316.00
1466.00 1617.00
894
1085 1276 1470
8 8 8 8
STEAM
bailerburner
number
gross 1 =8=8
Mbh
* 1 = 1=1
(opacity 9Ph
tankless number
1 = W=H
rating
net 1 = 8=1
Mbh
net 1 = 8=8
Trade Price
standard
opprex.
weight
vent sixe diam. m.
Steam units with factory installed tankless heater; No. 2 control set -- T822D thermostat, PA404A Pressuretrol, L4Q06A Aguastat operating control, R8184G ligh sensing primary control.
PFA-34-ST
300
2.65
226
6.0 225.1
938
$1231.00
905 8
PFA-35-ST
375
3.30
232
7.5
281.3
1172
1393.00
1096
8
PFA-36-ST
450
3.95
445
9.0
337.6
1407
1560.00
1287
8
PFA-37-ST
526
4.60
445
9.0
394.6
1644
1710.00
1481
8
Steam units less heater: No. 1 control set - T822Q thermostat. PA404A Pressuretrol, R8184G light sensing prima ry control.
PFA-34-S PFA-35-S PFA-36-S PFA-37-S
300 2.65 375 3 30 450 3.95 526 4.60
225.1 281.3 337.6 394.6
938 1172 1407 1644
$1161.00 1313.00 1460.00 1611.00
900 1091 1282 1476
8 8 8 8
Nozzle sizes furnished with the above units- (S -- solid: H -- hollow) PFA-34. 2.50 gph 70* S. PFA-35. 3 25 gph 45' S. PFA-36. 4.00 gph 45* S: PFA-37. 4 50 gph 30* S.
tGallons of water per minute heated from 40*F to 140*F wilh 200'F boiler water temperature
Vent needs to extend 3 feet above highest part of roof. Start-up service--price on application.
Standard Equipment
Water: ASME relief valve Pressure and temperature gauge
Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing cad cell with bracket and leads: V4046B
instantaneous oil valve; Syracuse elec tronic time delay; drain valve.
boiler-burner unit
PFA-34 PFA-35
oil burner
LC-334-A3 LC-334-A
boiler-burner unit
PFA-36^
PFA-37 f
oil burner LC-534-A
Units WITH water heater: 1 cover plate with 4L" control tapping.
Units LESS water heater: 2 cover plates for heater openings.
Steam: ASME safety valve Steam gauge Gauge glass with trimmings
Optional Equipment
Available in split assemblies. Specify nn order. Trade Price...................... $25.50
Zone valve packages aie available foi water boilers. For details and purer,
see page 33.
Foi other optional equipment
page
Ordtring Examples:
1. Pressure fired boiler-burner unif wilh standard equipment with heater for water1 1 PFA-34-WT boiler-burner unit
2. Pressure fired bailer-burner unit with op tional equipment less healer for steam: 1 PFA-37 S boiler-burner unit with jacket extension
HH-75-1 W See page 48
Page 24
-or cc~iD'ete SDecificaiions re'er io Technical Caia'og 3LMet'o Form no 91 *4-2 3ev 3 *
15667
_ AMERICAN STANDARD
HYORONIC HEATING
PFA-3 OPTIONAL EQUIPMENT
PRESSURE FIRED BOILER-BURNER UNITS
WATER AND STEAM
Jacket extension. Trade Piice .............................................$50.60
No. 5-Z control set for circulatoi z>ninc; with PFA-3 boiler-burner unitsequipped for tankless heater. 1 N'o. 5-Z set required for each zone in addition to the fit.-t zone which is controlled by the No. 5 control set or equivalent. Trade Price .................................................................................$30.05
McDonnell & Miller No. 67AR low water fuel cut-orf for steam. Trade Price ........................................................... $42.35
McDonnell & Miller No. i>3 low water cut-otf for water. Trade Price .................................................................................$57.50
Controls and control sets are shown on page 34.
I=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR PFA-3
Heaters tested with boilers. Built-in tankless heaters can be ordered for separate shipment with units or boilers specified less heater as follows:
unit no.
PFA-34 PFA-35 PFA-36 PFA-37
l = B =* burner copocity gph
2.65
3.30
3 95
4.60
heater no.
226 232 445 445
IsWs i rating
water
team
6.0 6 0 7.5 7.5 9.0 9.0 9.0 9.0
CfllloM of wafer per minyfe from 4QPF fo 140*F with 700*F boilor wafer temperaiwre Appropriate controls must Be ordered m addition to healer only aoove
preiigre drop thru heater
at ratod flow
23 psi 36 psi 37 psi 37 psi
healer only* Trode Price
$53.00 65.00 83.00 83.00
See page 48
Page 25
HH-75-:
15668
OIL BOILER-BURNER UNITS STEAM AND WATER
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
Jacketed--forced 'haft with <>il 50 lbs. water working j>i ""in o-- [' Equipped for tanK'e^ heaters.
-t-Mv\ . j \<. ..
preuure fired boiler-bumer unit number
off
grots
1 =i=
output
1=8 = 1 bumor
(Opacity
oil *p*
piping ond pickup factor
$ foam
wotir
no 1 =B = rofing
Mbh
itoom wafer
itoam
not
q. ft. orator
Trod# Price with itondard equipment
oil
vont til#
in.
approx
imate
hipping weight
burner model luppl.ed with itondard equipment
... Oil
PFA-504-* O(T) PFA-505-* O(T) PFA-506-' O(T)
620 786 950
5.45 6 90 8.35
1.333 1.333 1 333
1.15 1.15 1 15
465 1 589 6 712.7
539.1 683.5 826.1
1938 2457 2969
3594 4557 5507
$1944.00 2291.00 2554.00
10 10 10
1840 2210 2520
95A-1 -8702-JBT 96A-M-6131 -JC-T 96A-M-6131-JC-T
PFA-507-* O(T) PFA-508-* 0(T) PFA-509-* O(T)
1116 1282 1446
9.80 11.20 12.65
1.333 1.330 1.315
1.15 837.2 970.4 1 15 963 9 1114 8 1.15 1099 6 1257.4
3488 4016 4582
6469 7432 8383
2924.00 3241.00 3469.00
10 10 14
2880 3190 3550
96A-B-8316-JC-T 96A-B-8318-JC-T 96A-B-8318-JC-T
PFA-510-* O(T) PFA-511-* O(T) PFA-512-* O(T)
1612 1776 1944
14.10 15.55 16 95
1 302 1 292 1 288
1.15 1238.1 1401.7 1.15 1374.6 1544.3 1.15 1509.3 1690 4
5159 5728 6289
9345 10295 11269
4065.00 4714.00 5087.00
14 14 14
3935 4285 4645
96A-T-A-8419-JC-T 97A-T-A-8614-JC-T 97A-T-A-861 4-jC-T
PFA-513-* O(T) PFA-514-* O(T) PFA-S15-* O(T)
2108 2272 2440
18 40 19.85 21.25
1 288 1 288 1.288
1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7
6819 7350 7893
12220 13171 14145
5331.00 5580.00 6101.00
14 14 14
4955 5317 5675
97A-T-A-861 4-JC-T 97A-T-A-861 5-JC-T 97A-T-2-7635-E-1
PFA-516-* O(T) PFA-517-* O(T) PFA-S18-* O(T)
2604 2768 2936
22.70 24.15 25.60
1.288 1.288 1.288
1.15 2021.7 2264.3 1 15 2149.1 2407 0 115 2279 5 2553.0
8424 8954 9498
15095 16047 17020
6492.00 6720.00 7168.00
18 18 18
5985 6345 6750
97A-HI-L.O-2-7685-E-I 97A-HI-LO-2-7685-E-1 98A-HM.O-2-7771-E-1
PFA-519-* O(T) PFA-S20-* O(T) PFA-521-* O(T)
3100 3260 3430
27 00 28.45 29.90
1 288 1.288 1.288
1.15 2406 8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6
10028 10546 11096
17971 18899 19884
7420.00 7663.00 7951.00
18 18 18
7060 7420 7780
98A-Hi-lo-2-7771 -E-l 98A-Hi-lo-2-7771 -E-l 98A-Hi-Lo-2-7771-E-l
_____
Height 3 feet above highevt part of roof
The net l = B~R rating! ihown are bated on piping and pick up allowances listed above. American-Standard should be consulted before selecting a boiler for installations having unusual piping ond pick-up requirements.
Available as assembled una or with assembled sections--see cage 2" Substitute tetter "S" for steam; "W" for water. Start Up and One Year's Service . . . Price on Application
Suffix (Tl denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heaters, see page 27.
Nozz'es sizes--see page % Nozzle sizes, gph, furnished with the above on burners are as follows:
unit no. gph. typo
unit no. gph. type
unit no gph. typo
unit no. gptv typo
unit no. 9Ph. type
unit no gph iyp
PFA-504 2 2.75 90H
PFA-505 2 3.50 90H PFA-506 2 4 00 80H PFA-507 1 4 50 70H
1 5.00 70H PFA-508 2 5 50 80H
PFA-509 1 6.00 80H PFA-512 2 7 00 70 = H
1 6 50 80'H
1 2.50 70H
PFA-510 2 5 50 90H PFA-513 2 7 00 70H
1 2.75 90H
1 4.00 70H
PFA-511 2 6 50 80H
1 2 00 80H PFA-514 2 8.00 60'H
PFA-514 1 3 50 60 H PFA-517 1 10 00 90'S PFA-520 1 8.00 80'S
PFA-515 2 8 00 70H PFA-51B 1 7 50 90'S
1 8 50 80'S
1 5.00 70H
1 8.00 90S
1 12 00 80>S
PFA-516 2 7.00 90S
1 10 00 90'S PFA-521 2 8 OQ 80 S
1 8.50 90S PFA-519 2 7 50 80S
1 14 00 80'S
PFA-517 2 7 00 90`S
1 12 00 80 S
hh-75-1 See page 48
Cj-
r?'e' *c
Page 26
Cr.i:5
N2 ?' 2
~"
15669
PFA-5 pressure fired boiler-burner units
Standard Equipment--All Boilers
Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve.
Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve.
Standard Equipment--Oil Fired
Flange mounted oil burner--D7A-T-A, dTA-T-J, 97A Hi-Lo and 98A Hi-l.o burners furnished with flange and pedestal. On 95-A1, 96A-M. 06A-B, UdA-T-A and 97A-T-A hurners. factory installed cad cell, bracket and leads, R8185E light sensing primary control; V4046B instantaneous oil valve,
ST70A1002 electronic time delay. On 97A-T-2, 97A Hi-Lo-2 and 98A Hi-Lo-2 burners. R4150A control--provides pre purge and post-purge, Q520A base, factory installed C7013A photo cell; delayed and instantaneous oil valves, nozzles. 2 stage fuel unit on all burners.
Standard Motor Voltages
PFA-504 thru PFA-510 PFA-511 thru PFA-521
115/60/1 230/60/1
Ordering Examples: PFA-5 boiler-burner unit for steam with standard equipment. 1--PFA-514-SO boiler-burner unit PFA-5 boiler-burner unit for water with optional equipment. 1--PFA-511 -WO(T) with jacket extension; 4 No. 548 tankless heaters; with L6006A control.
Optional Equipment--Oil Fired
Oil Hcii iif-; t^mpped f-r T M M. i etui i *emont> f..i ['FA-''11 :* ._:i f' [ \-`h
A>Id'1'( Tiade ['net'
$215.00
RMI-MOi < f"I ['FA-MI \ ` I '11 J ' I f 1 !' \ - A J 1
,.( |
to meet V.M. re<|im eu m.* : K .imm -\t ;n.-1<;.I< -: K n \
which providers pie- itf ti )-' i-1,';.-- < ToplA
tn i \ '
and t^*i2'A Rase, i
Oil Rutnet>fm FI.A. i < | *.t: i ::: ^ r ' L j ' i oi a ppis`.
Oil hurners for PFA-olo thru I'FA-MM f.u Mu--a< ;ir Code requirement.--- ['rice on applicatuui
Prewired Control Panels on burnei--- Piin^ -m m tton.
Optional dinners anil assembly arrangement- ;; .low.
PFA-5 OPTIONAL ASSEMBLY AND OIL BURNERS
PFA-504 PFA-505 PFA-506
PFA-507 PFA-508 PFA-509
PFA-510 PFA-511 PFA-51 2
PFA-51 3 PFA-514 PFA-515
PFA-51 6 PFA-517 PFA-518
PFA-519 PFA-520 PFA-521
ABC oil burners
assembled sections
add to Trade Price
packaged boiler unit
80 lbs. water test
jacket extension
Gordon-Piatt oil burners
96A-T-A-8406 JBT 96A-T-A-8408 J0T 96A-T-A-8408 JCT
5163.00 153.00 153-00
96A-T-A-8409 JCT 96A-T-A-8410 JCT 96A-HI-LO-A-8808 JCT
96.00 96.0Q . 350.00
96A-HI-LO-A-8808 JCT 254.00
$ 99.00 165.00 198.00
231.00 264.00 297.00
330.00 363.00 396.00
429.00 462.00 495.00
528.00 561.00 594.00
627,00 660.00 693.00
$666.00 684.00 702.00
719.00 737.QQ 848.00
869.00 889.00 910.00
929.00 949.00 969.00
990.00 1010.00 1031.00
1050.00 i 1071.00 | 1091.00
$ 44.00 55.00 66.00
$85.15 85.15 85.15
RL 6 2-Q-03-F4B RL 6 2-0-Q3-F48 RL 5 2-0-03-F4B
$82.50 61.00 61 00
77.00 88.00 99.00
85.15 85.15 85.15
RL 8 0-0-05-F4B RL 8 1-0-05-F4B RL 8 1-0-05-F4B
28 00 28 00 28 00
110.00 121.00 132.00
85.15 85.15 85.15
RL 3 2-0-1Q-F4B RL 8 2-0-1Q-F4B PL 3 2-0-10-RJB
77 00
--
--
143.00 154.00 165.00
176.00 187.00 198.00
|
209.00 220.00 231.00
85.15 85.15 85.15
RL a 2-0-15-F4B RL 8 3-0-1 5-F4B RL 8 4-0-20-P4B
85.15 85.15 85.15
RL 8 4-0-2C-'4B , RL 10 1-0-20-F4B RL 10 l-OMO-MB
85.15 85.15 85.15
! RL 10 1 -0-30-GP 1 COR- F4B RL 10 1 -0-30-GP 10QR- F4B
' RL 10 i -3-30-GD 1Q0P-F4B i.
___ --
-- --
--
--
___ --
--
See page 48
Pace 2~
15670
HH-'h'
GAS BOILER-BURNER UNITS STEAM AND WATER
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
Jacketed--forced draft with gas burner 50 lbs. water working: pressure--15 lbs. steam working: pre.-suie. Equipped for tankless heaters.
preiture ftred boiler-burner emit number
greu 1 =S =*
BUfput Mbh
goi __________
PFA-504-' G(T) PFA-505-' G(T) PFA-S06-' G(T)
620 786 950
11
l=tsl burner
copocitp
763 966 1169
piping and pickup factor
iteom
1 333 1 333 1 333
: water i________ 1 i 1 15
1 15 1 15
net st B = R rating
j net
Mbh
team
wotir
j ,
!| :tleam
rating
*0- ft. water
465 1 539.1
589.6 683 5 712.7 826 1
1938 2457
2969
3594 4557 5507
PFA-S07-* G(T) PFA-508-* G(T) PFA-509-* G(T)
1116 1282 1446
1372
1568 1771
1 333 1 330 1 315
1 15 837 2 970.4
1 15 963 9 1114.8 115 1099.6 1257.4
3488 4016 4582
6469 7432 8383
PFA-510-* G(T) PFA-511-' G(T) PFA-512-* G(T)
1612 1776 1944
1974 2177 2373
1.302 1.292 1 288
1.15 1238.1 1401.7 1 15 1374.6 1544 3
1.15 1509 3 1690 4
5159 9345 5728 10295 6289 11269
^ Trod. Price wtlh tfondard equipment
gai
$3111.00 3434.00 3687.00
4114.00 4446.00 4674.00
5273.00 5990.00 6386.00
Vttlf
lit. diem.
tn.
appreiimat. ihipptng weight
burner ncdtl suppled with ifondord equipment
got
10 1840 ; 86 2 G-03 R4795 B 1 2S 10 2210 R6 2-G-03-R4795-8 1 2S 10 2520 R6 2-G 03-R4795 B 12
10 2880 R8-G-05 R4795-B 12 10 3190 i R8-G-05-R4795-8 15 14 3550 R8-G-G5-R4795-B 15
1 14 3935 1 R8.1 G-05-R4795-B 20 14 4285 R8.2-G-05-4150A-H 20 14 4645 R8 3-G-10-4150A-H 20
PFA-513-' G(T) PFA-514-* G(T) PFA-515-* G(T)
2108 2272 2440
2576 2779 2975
1 288 1.288 1 288
1 15 1636 6 1833.0 1.15 1764.0 1975 7 1 15 1894 4 2121 7
6819 12220 7350 13171 7893 14145
6699.00 14 4955 R10 9-G-10-41 50A-H 20 6948.00 14 5315 R10 9-G-10-41 50A-H 20
7170.00 14 5675 R 10.9-G-10-41 50A-H 20
PFA-516-* G(T) PFA-517-* G(T) PFA-518-* G(T)
2604
2768 2936
3178
3381 3584
1 288
1.288 1 288
1 15 2C21.7 2264.3
1.15 2149 1 2407 0 1 15 2279 5 2553.0
8424 15095 8954 16047 9498 17020
7650.00 7678.00 8124.00
18 5985 R10-G-15-4150A-H 25S
18 6345 R 10-G-15-4150A-H 25S 18 6750 R 10.1 -G-1 5-4150A-H 25S
PFA-519-' G(T) PFA-520-' G(T) PFA-521-' G(T)
3100 3260 3430
3780 3983 4186
1 288 1 288 1 288
1 15 2406 8 2695 7 10028 17971 1 15 2531 1 2834 8 10546 18899 1 15 2663 0 2982.6 11096 19884
8628.00 18 7060 i R10 1 G 20-4150A H 25
8872.00 18 7420 R 10.1 -G-20-4150A-H 25 9160.00 18 7780 R10 1 -G-20-4150A-H 25
The net 1=B=R ratings shown are based on piping and pick-up allowances listed above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements.
'Substitute letter "S" for steam. 'W for water START-UP AND ONE YEAR S SERVICE: INCLUDED IN TRAOE PRICE OF GAS UNIT I Suffi iT) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Woter Heaters, see page 27.
Height 3 feet obove highest part of roof.
Available as assembled unit or assem&iec secmons--see cage ;'
Standard Equipment--All Boilers Steam: PA404A Pressuretrol, ASME safety valve, steam
gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure arid
temperature gauge, drain valve.
Standard Equipment--Gas Fired Flange mounted gas burner. Standard burner controls meet latest UL requirements. Dual automatic gas valves for add ed reliability. Gas-electric ignition. Electronic program ming controls and components are factory wired in a con trol cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burners equipped to operate with 1,000 Btu, 0.6 specific gravity natural gas.
Ordering Examples: PFA-5 boiler-burner unit for steam with standard equipment. 1-- PFA-514-SG boiler-burner unit PFA-5 boiler-burner unit for water with optional equipment. 1 --PFA-511-WG{T) with jacket extension; 4 No. 548 tankless heaters. Specify gas pressure available at gas train inlet.1
(1) Surcharge for Start-Up and Service west of Mississippi River. Contact American-Standard for details.
Gas and Gas-C'i Burners not stocked ai Bond Plant 3 lo 4 weeks lead lime for sriioment of Standard Equooed Burners after recent of order a) Hadronic Order Service Center
Optional Equipment
PFA-5 units for Factory Mutual and Factory Insurance
Association minimum requirements at the following add ed charges:
boiler tic#
F M.
got hred ---------------
F I A.
PFA-504-510
$682.00
$ 827.00
PFA-511-515
811.00
1074.00
PFA-516-521
811.00
1074.00
For prices of gas burners for use with other than 1000 Btu, 0.6 specific gravity natural gas. or at gas pressures above or below pressures shown in current literature, consult vour American Standard District Office.
High Risk F.M. or F.I.A. requirements .
Hi-Lo Fire Control ........
Modulating Fire Control
Alarm System pre-wired and mounted on control cabinet.............................
Optional Combustion Controls Controls to meet local requirements
Price on
Application
For Additional Optional Equipment and assembly a: rangements, see page 27.
Standard Motor Voltages
unit number
gai burner*
PFA-504-511 PFA-512-521
115-601 230-60-3
Other optional motor voltages--Price on Application.
HH-75-1 W See page 48
Page 28
oo e'e soeci' cai'ons 'e'er *o T.?:"n cai Ca:3'0g SuUenn Form No 9115-2 Rev 2 6 *2
15671
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
Jacketed--forced draft with combination ga.'/oi! buiner. 50 lbs. water working1 pressure--15 lbs. steam working pressure. Equipped for tankless heateis.
GAS-LIGHT OIL BOILER-BURNER UNITS
STEAM AND WATER
pretture fired unit number
gop--- light oil
grot*
1 =B=I
output Mbh
1=8=R 1 burner 1
gat input Mbh
!
piping and
net
____tleam 1 water tleam
= 1=1 rolmg
water
1 net
| o- i'-
water
Trod*
Price with tiondord equipment
| 1
vent
tic*
got---oil
PFA-504-* GO(T) PFA-505-* GO(T) PFA-506-* GO(T)
620 763 786 966 950 1169
1 333 1 333 1 333
1 15 465 1 539.1 1 15 589 6 683 5 1 15 712.7 826 1
1938 i 3594 $3636.00 i 10 2457 ; 4557 3959.001 10
2969 5507 4309.00 10
PFA-507-* GO(T) 1116 1372 PFA-508-* GO(T) 1282 1568
PFA-509-* GO(T) 1446 1771
1 333 1 330
1,315
1 15 837 2 970 4 1 15 963 9 1114.8 1 15 1099 6 1257 4
3488 4016 4582
6469 7432 8383
4679.00 5082.00 5310.00
to 10 14
PFA-510-* GO(T) 1612 1974
PFA-511-* GO(T) 1 776 2177 PFA-512-* GO(T) 1944 2373
1 302 1 292 1 288
1 15 1238.1 1401 7 1 15 1374 6 1544 3
1 15 1509.3 1690 4
5159 9345 5728 10295 6289 11269
5961.00 6443.00 6927.00
14 14 14
PFA-513-* GO(T) 2108 2576 PFA-514-* GO(T) 2272 2779 PFA-515-* GO(T) 2440 2975
1 288 1.288 1 288
1 15 1636 6 1833 0 1 15 1764 0 1975 7 1 15 1894 4 2121 7
6819 12220 7350 13171
7893 14145
7243.00 7492.00 7714.00
14 14 14
PFA-516-* GO(T) 2604 3178 PFA-S17-* GO(T) 2768 3381 PFA-518-* GO(T) 2936 3584
1.288 1 288 1 288
1 15 2021 7 2264.3 1 15 2149 1 2407 0 1 15 2279 5 2553.0
8424 15095 8954 16047 9498 17020
6190.00 8418.00 8768.00
18 18 18
PFA-519-* <:0(T) 3100 3780 PFA-520-* GO(T) 3260 3983 PFA-521-* GO(Tl 3430 4186
1 288 1 288 1.288
1 15 2406 8 2695.7 10028 17971 | 9188.00 1 15 2531 1 2834 8 10546 18899 9548.00 1 15 2663 0 2982 6 11096 19884 9836.00
18 18 18
| approx-
1 J (hipping |
weight
`
burner model tupplied wif ttondard equipment
gat--ol
1840 2210 2520
2880 3190 3550
R6.2-GO-03-R4795-B 12S-F40 R6 2-GO-03-R4795-B.12S-F48 R6.2-GO-03-R4795-B.12-F4B
R8-GO-05-R4 795-8 12-F3 R8-G005 R4795-8 15-F3 R8GO05R4795 B15-F3
3935 R8 1GO-05 R4795 B 20 F3 4285 R8.2 G0 07 4150A-H 20-F4H
4645 R8.3-GO-10-4150A-H 20-F4H
4955 R10.9-GO 10-4150A-H 20 F4H 5315 R10 9-GO-10-4150A H 20 F4H 5675 R10 9-GO-10-4150A H 20-F4H
5985 R10-GO-15-41 50A-H 25S F4H 6345 R10-G 0-15-41 50A-H.25S-F4H 6750 R10 1GO-20-4150A H 25S-F4H
7060 R10 1GO-20-4150A-H 25-F4H 7420 R 10.1 G0-30-4150A-H 25-F4H
7780 RIO 1GO-30-4150A H 25-F4H
The net I -- B -- R ratings shown are based on piping and pick-up allowances listed above American-Standard should be consulted before selecting a boiler for Installations having unusual piping and pick-up requirements
Substitute letter "S" for steam; ' W" for water START-UP AND ONE YEAR'S SERVICE INCIUOEO IN TRADE PRICE OF GAS Oil UNIT'D Suffix (T) denotes boiler with openings in center section for tankless heoters when specified. For Built-in Water Heaters, see page 27
Height 3 feet above highest part of roof.
AvailaOle as assemoied unit or assented sect-ons--see ca-e J'
Standard Equipment--All Boilers
Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve.
Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve.
Standard Equipment--Gas-Light Oil Fired
Flange mounted combination gas-oil burner. Standard burner controls meet latest UL requirements. Manually operated fuel switch for dual fuel change-over. Dual auto matic gas valves for added reliability. Gas-electric ignition.
Electronic programming controls and components are fac tory wired in a control cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section: proven pilot. Standard burner equipped to operate on No. 1 or No. 2 fuel oil and 1,000 Btu, 0.6 specific gravity natural gas.
Standard Motor Voltages
.nil numb*.
ga.-oil burn*..
PFA 504-510
PFA-511 PFA-512-521
115-60-1
230-60-1 230-60-3
Other optional motor voltages--Price on Application.
(1) Surcharge for Start-Up and Service watt of Mississippi River. Contact Americon*Stondord for detoils.
15672
Ordering Examples: PFA-S boiler-burner unit for steam with standard equipment 1 -- RFA-51 4-SGO boiler-burner unit. PFA-5 boiler-burner unit for water with optional equipment 1 --PFA-5 H -WGO(T) with jacket extension, 4 No. 548 tankless heaters. Specify got pressure available at gas train inlet.
Nozzle s^es, gph, furnished witn combination gas-iignt on burners are as follows. (nozzle capacity is dependent on on pressure )
unit no. gph. type
unit no. gph. type
unit no. gph type
PFA-504 1 4 00 90H PFA-505 1 5 00 90H PFA-506 1 6 50 90H PFA-507 2 4 00 90S PFA-508 2 4 00 90S PFA-509 2 5.00 90S
PFA-510 2 5 00 90S PFA-511 2 5 50 90S PFA-5! 2 2 6 00 90S PFA-513 2 7 00 60S PFA-514 2 7 00 60S PFA-515 2 7 00 60S
PFA 516 2 7 00 60S PFA-517 2 8 00 60S PFA-518 2 8 00 60S PFA-519 2 8.00 60S PFA-520 2 8 50 60S PFA-521 2 9 00 60S
Optional Equipment
PFA-5 units for Factory Mutual and Factory I nsui an<>*
Association
requirements at the following aim
ed charges:
got-oil fired
boiler tit*
F.M.
fIA
PFA 504-510 PFA 511-515 PFA-516-521
S 824.00 1059.00 1054.00
$ 899.00 1227.00 1239.00
Automatic Fuel Changeover Trade PriceT!................................................................. $237.00
For prices of gas-oil burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office.
High Risk F.M. or F.I.A. requirements
Hi-Lo Fire Control .
..
Modulating Fire Control
Price
Alarm System pre-wired and mounted on control cabinet
Optional Combustion Controls
on Application
Controls to meet local requirements
Additional optional equipment and assemble ai i angf n:..... .. --see page 27.
Gas and Gas-Oil Burners not stocked ai Bona Plant 3 to 4 .vee*s -.-it t.me lor shipment of Slandard Equipped Burners aUe' 'ece^ot o' vre* ai H-ydronic Order Service Center
See gage 48
r0, :o, oie'e scec : v-O'-s
Page 29 > - '*> 3 C a'a'Cg 5
:-2 o.;.
Hh-75-'
OPTIONS--A-5/FRA-5/PFA-S TANKLESS WATER HEATERS LOW WATER CUT-OFFS
TS\ AMERICAN SiSTANDARD
HYDRONIC HEATING
TANKLESS WATER HEATERS FOR A-5, FRA-5 AND PFA-5
Tankless water heaters are available in any quantity at the following: Trade Prices:
hoetor ftvmb*' used with
pres, drop at rated flow
Trod# Price eoch
530 548
A-5. FR-A-5 PFA-5
15 psi 16 psi
$54.00 89.55
PFA-5 units with tankless water heaters require additional controls at current prices as follows:
STEAM: L4006A Aquastat operating: control.
Trade Price
$16.90
WATER: L6006A Aquastat operating; and circulator
control.
Xrade price
$17.95
Cover plate required to dose unused water heater
in*rs will be furnished if specified on order for
t>p-
boder. Trade Price each ..........................................................
PFA-5 A-5. FRA-5
... Trade Price each..................... $5.45
Factory assembled copper pipe manifold for parallel hook up of multiple heaters are available as follows:
irailNId
ainmSIy
'WT.od* Filc
f|.*.s
2 Heater............................................................................ . $11.05
3 Heater
........................................................................ 16.00
4 Heater ............................................................................
20.50
A-S end Fl-A-S beilo*
A-5 or FR-A-504-T A-5 or FR-A-505-T thru 507-T A-5 or FR-A-508-T thru 509-T A-5 or FR-A-510-T thru 511-T
mas. no. af optningi
2 3 4 5
MA-S bailor
PFA-504-T PFA-505-T thru 506-T PFA-507-T thru 508-T PFA 509-T thru 511-T
mas. ne. af opening*
1 2 3 4
PfA-S beilar
PFA-512-T thru 514-T PFA-515-T thru 51 7-T PFA-518-T thru 519-T PFA-520-T thru 521-T
mos. na. of opening*
5 6 7 8
The following table shows ratings attained if more than one heater is connected in parallel:
A-5 or FR-A-5-T all sues A-5 or FR-A-5-T all sizes A-5 or FR-A-505-T thru 511-T A-5 or FR-A-508-T thru 511-T A-5 or FR-A-510-T thru 511-T
no of heoleri
1 2 3 4 5
rofing gpm.
4 7 10 13 16
bailor number
PFA-5-T all sizes PFA-505-T thru 506-T PFA-507-T thru 508-T PFA-509-T thru 511-T PFA-512-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PFA-520-T thru 521-T
Gallon* of l*r par minulo roiiod from 40*F lo 1 40*F with 200*F bailor want ttmptroNr*.
no of hooter*
i 2 3 4 5 6 7 8
rotlng gpm
8 16 24 32 40 48 56 64
McDonnell & miller low water cut-offs
STEAM: No. 369 Low Water Cut-off for A-5, FR-A-5, PFA-5 ............................................... $ 34.30
No. 47-2 Feeder and Cut-off for A-5, FR-A-5, PFA-504 thruPFA-509
98.00
No. 51-2 Feeder and Cut-off for PFA-510 thru PFA-521 ........................................ 127.05
WATER--50 PSI: No. 63 Low Water Cut-off for A-5, FR-A-5 and PFA-6
57.50
WATER--80 PSI: No. 150 Low Water Cut-off for PFA-5 ........................................
85.90
"W See page 48
paqe 30
15673
^AMERICAN L5J STANDARD
HYDRONIC HEATING
OIL FIRED BOILER-BURNER UNIT WATER AND STEAM
FR-A-5 FLAME RETENTION BOILER-BURNER UNITS
Jacketed -- fid ib>. w a t o i precision ground ---wi:h m wuh.mt .ankle" -ate-
am wiii k.nu |' i`"lM ' \ I'l Ml , V 1 V
- 1' i . a
WATER
boiler-burner unit number
gross l=8=R output
Mbh
t=0=R
burner capacity
*ph
net 1--S=R rating
Mbh
net rating
sq. ft. water
Trade Price with standard equipment
For Built-in Water Heaters, Steam and Water Boilers, see page 27.
FR-A-504-WB(T) FR-A-505-WB(T) FR-A-506-WB(T)
FR-A-507-WBCT) FR-A-508-WB(T) FR-A-509-WB(T)
FR-A-510WB(T) FR-A-511-WB(T)
384 472 560
648 736 824
912 1000
3.55 4.30 5.10
5.90 6.70 7.45
8.25 9.05
333.9 410.4 487 0
563.5 640.0 716.5
793.0 869 6
2226 2736 3246
3756 4266 4776
5286 5797
SI 394.00 1542.00 1798.00
1963.00 2288.00 2453.00
2630.00 2805.00
approx. shipping
weight
chimney size
1576 1827 2110
2367 2626 2890
3144 3392
12 x 12 * 15 12 x 12 x 20 12 x 12 x 20
12 x 16 x-20 12 x 16 x 20 12 x 16 x 20
16 x 16 x 20 16 x 16 x 20
STEAM
boiier-bumer unit number
gross
1=B--R output
Mbh
l = B=sR burner
capacity gph
net 1 = 8 = R rating
Mbh
sq. ft. steam
^ Trade Price with standard equipment
approx.
shipping weight
chimney size
FR-A-504-SB(T)
FR-A-505-SB(T) FR-A-506-SB(T)
384 3.55 472 4 30 560 5.10
288.1 354.1 420.1
1200 1475
1750
1394.00 1542.00 1798.00
1577 1828 2112
12 12 12
15
FR-A-507-SBCT) FR-A-508-SB{T) FR-A-509-SB(T)
FR-A-510-SB(T) FRA-511-SB(T)
648 736 824
912 1000
5.90 6.70 7.45
8.25 9.05
486.1 552.1 618.2
684.2 750.2
2025 2301 2576
2851 3126
1963.00 2288.00 2453.00
2630.00 2805.00
2369 2628 2892
3147 3395
12 12 12
16 16
'WAGC nozzle sizes ocn furnished for rdovp ,n:s eRA-5CA 3 5 30 D FRA-503 * 30 f> cRA-50d .5 FRA-509 7 5 45' P FRA-510 3 45 P FRA-511 9 45 P
Suffix "T" denotes unit with openings in center sections for tankless heaters Start-up and one year
i- 5C * i ;C 3
5 5 45
vailaoie. Price on application
Standard equipment Fiance mounted ml burner with 2-stage fuel unit; delayed oil vahe on model LC-TU-A and in>taiuaneo burnei.>; light .'pnsme primary control.
IA
boiler-burner unit number
oil burner
FRA-504 thru FRA-507 LC-534A-D 41752 FRA-508 thru FRA-511 HC-34-A-D 41751
Draft regulator Drain valve
15674
Water: No. 3 control set: T822D thermostat L4080B Aquastat limit control Nozzle(s)
ASME relief valve Pressure and temperature gauge
Steam: No. 1 control set: T822D thermostat PA404A Pressuretrol Nozzle(s)
ASME safety valve Steam gauge Gauge glass with trimmings
S" lb.'. 'Autei test. Trade Pi ice pei >ectiuii .. facket nxteii.'ion Tiade Fb ice
Optional Equipment
$11.00 $56.00
Cover plate it><|ihmi m i )..-? .inur'd
furnished if >|)eci!,pd >>\\ -a dec fm "T" ivpe
Price each
....
F .l $5 45
Fm I'act-u \ Mutual Appinval and Ma>'aenii>ett.- codr i ji|uirements. special electronic flame -afegiianl conttnl.> aio available, witn IMl-V'A Pi ntectoi elay, <*-7ni:>A photoi eil. and <atVtv oil \ al ve.
oil hosting unit
burner model
added Trade Price charge
Control sets other than those included in Trade Price of FR-A-5 boiler-burner units will be furnished on order at the following added charges:
Control Sot
ddd chorgo
Steam control set No. 2 Water control set No 4 Water control set No 5 Water control set No. 5-Z
S16.90 12.15 25 85 30.05
FRA-504 *hru FRA-507
LC-534A-D 41431
$282.00
'Addon zone Use only with No 5 Cont-ol Set The No 5 Z control set for circular zoning on units wah tanniess heaters }
Ordering Examples:
F RA-508 thru FRA-51 1
HC-34-A-D 41431
282.00
l. Boiler burner unit with standard equipment 1 FR A 506 SB oil heating und 2 Boiler burner unit tor steam with optional equipment 1 FR A 509 SB T with No .
control set, 3 No 530 tankless heaters, l 3 heater manifold
See page 48
Rjqe 3t
OIL FIRED BOILERS WATER AND STEAM
rsi AMERICAN LSI STANDARD
HYDRONIC HEATING
A-5 OIL FIRED BOILERS
WATER
Jacketed--.50 lbs. water working ptessure--15 lbs. steam working; picture. Sections with or without tankless heater.
boiler number
gross
f=B=R output
Mbh
l= 8=R
burner capacity
*Ph
net 1 = B=r R
rating Mbh
net rating sq ft water
Tredo Price
For Built-in Water Heaters, Steam and Water Boilers, see page 27.
approx. shipping weight
Ixa
A-504-W(T) A-505-W(T) A-506-W(T)
A-507-W(T) A-508-WfT) A-509-W(T)
A-510-W(T) A-511-W(T)
261 346 426
508 588 668
748 830
2.55 3.30 4.00
4.75 5.55 6.30
7.00 7.65
227.0 300.9 370.4
441.7 511.3 580.9
650.4 721.7
1513 2006 2469
2944 3408 3872
4336 4811
$1002.00 1151.00 1311.00
1477.00 1636.00 1794.00
1959.00 2129.00
1518 1770 2025
2282 2539 2794
3050 3298
8 x 12 x 15 8 x 12 x 20 12 x 12 x 20
12 x 12 x 20 12 x 16 x 25 12 x 16 x 25
12 x 16 x 25 16 x 16x30
STEAM
boiler number
A-504-SC0 A-505-S(T) A-506-S(T)
A-507 S(T) A-508-SC0 A-509-S(T)
A-510-S(T) A-511-S(T)
gross 1=8=R output
Mbh
261 346 426
508 588 668
748 830
1=8=R burner capacity
gph
2.55 3.30 4.00
4.75 5.55 6.30
7.00 7.65
net lsB = R rating
Mbh
sq ft steam
195.8 259.6 319.6
816 1082
1332
381.1 441.1 501.1
1588 1838 2088
561.1 622.7
2338 2594
Trad# Price
$1002.00 1151.00 1311.00
1477.00 1636.00 1794.00
1959.00 2129.00
approx. shipping weight
1519 1771 2027
2284 2541 2796
3052 3300
chimney size
8x 12x 15 8 x 12 x 20 12 x 12 x 20
12 x 12x20 12 x 16x25 12 x 16 x 25
12 x 16 x 25 16 x 16 x 30
Suffix "T" denotes boiler with openings in center sections for tankless heaters.
Standard equipment:
Optional equipment:
Water: ASME relief valve Pressure and temperature gauge Drain valve
Cover plate required to close unused watei heatei openings furnished if specified on order for "T" type boiler. Tiacie Price each ................................................................................... $5.45
Steam: ASME safety valve
Zone valve packages are available for water boilers. For details and prices, see page 33.
Steam gauge
Oil Burners available on
Gauge glass with trimmings
special order .............................................. Price on Application
Drain valve
Jacket extension: Trade Price ........................................... $56.00
Ordering Examples:
1 Boiler only (or steam with standard equipment: 1 A 507 S boiler.
2 Boile' only for water with optional equipment: 1 A-506 W boiler with jacket extension
80 lbs. wate>' test. Trade Price per section....................$11.00
For complete specifications refer to Technical Catalog Bulletin Form No 753-2 'Rev 2 5"
A-5 OPTIONAL EQUIPMENT
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit number
A-504 A-505 A-506 A-507, A-508 A 509, A-510, A-511
Heat Ub-O-Retor model No. included
14-A 15-A 15AA 16-A 17-A
maximum firing rate gallons per hour
2.55 3.30 4.00 5.55 7.65
Trade Price
$51.00 51.00 65.00 65.00 74.00
approx. shipping weight
158 163 176 180 200
HH-75-1 'W See page 48
Page 32
15675
fS\ AMERICAN caSTANDARD
HYDRONIC HEATING
oil burners
OPTIONAL EQUIPMENT
DH OIL BURNERS The DH burner. 115 volt, 60 cycle power supply.
model number
DH-4-F DH-5-F DH-5 DH-8 DH-15 DH-23
topocity gal.
per hour
.55 - 3.00 .55 - 3.00 .55-3.00 .65 - 3.00 .65 - 3.00 .65 - 3.00
air tube diam. length
mounting
Trede Price with neicle
include* factory fnttalled cod call
with no. 1 or no. 3 control cot and primary control
with primary control and
itoiile
Uu cod coll
44
sling
$208.00
45
sling
208.00
45
sling
208.00
4 8 (pedestal! 218.00
4 15 < r >
4 23 l flange >
218.00 218.00
$186.00 186.00 186.00 191.00 191.00 191.00
$148.15 148.15 148.15 153.70 153.70 153.70
app hip weight
gwtth control
lot
55 55 55 60 64 68
boUar bumtr unit oil bumor controls
Disc-turbulator combina tions for DH oil burner are as follows:
Selection of nozzle:
V-3M boiler unit DH-5
| Primary control, controls. ! Cad cell factory installed. I Draft regulator.
Note: For V-3M units pressure ring is packed with DH-5 burner.
firing rata no.
firing rata tph
nozzlo pray
.55 to 1.25 60'-70* hollow i .65-1.10
or solid 2 .90-1.75
3
1.80-2.50
above 1.25 60` 70* solid
4 2.35-3.00
Oil burners listed in this Price Book are approved by the National Board of Fire Underwriters, comply with U. S. Government Commercial Standard CS-75, and are for use with No. 1 or No. 2 fueloil.
Capacities of oil burners using No. 1 or No. 2 fueloil are for installations at sea level and at elevations up to 1,000 feet. Reduce by 4% for each additional 1,000 feet above sea level.
corcblete speed
rafar
The correct disc-turbulator combination is furnished in stalled in the DH burner for nozzle size specified on order.
Two-stage fuel unit available for DH oil burners.
Trade Price ............................................................................. $8.30
Controls and control sets are shown on page 31 Ordering Examples:
1. Oil Burner 1 DH-5 oil burner with No. 5 control set and 1 25 gph 70solid nozzle for V3M-138WT boiler-burner unit
2. Oil Burner 1 DH-23 oil burner with No. 3 control set. 1 50 gph 60 solid nozzle, with pedestal.
HYDRONIC ZONE VALVE PACKAGES
No. Z-2 Package for 2 Zones
No. Z-3 Package for 3 Zones
No. Z-4 Package for 4 Zones
1 T822D thermostat
2 V8043F
zone valves soldered to
manifold
Less transformer
^ Trade Price
$106.00
2 T822D thermostats
3 V8043F
zone valves soldered to
manifold
Less transformer
^ Trade Price
. . $140.00
3 T822D thermostats
4 V8043F
zone valves soldered to
manifold
With transformer
w Trade Price
$190.00
Each zone valve package consists of 2, 3, or 4 Honeywell " zone valves soldered to manifold with 1!4" NPT
inlet, wired to low voltage leads for transformer and all
If W' system piping is used, a H x H nominal copper to copper flush bushing can be soldered to any or all of the \ " zone valves on the manifold. Flush bushing not furnished.
(auxiliary) switches wired in parallel with a pre-wired harness. On-the-job wiring requires 115 volt line to transtoi mer. low voltage connections to circulator conttol. and low voltage wiring to each thermostat.
One less thermostat is furnished than the number of zone valves per package. An additional thermostat is required when zone valve package is used on boiler furnished less
thermostat.
40 VA transformer is not required when control L8148G or
If 40 VA transformer is wanted with No. Z-2 or No. Z-3 Pa<
age prices.
.........
!26B with power for 3 zone valves, is supplied with boiler.
*es, specify on order and add to the above Zone Valve Pack* ., . w Trade Price each $4.00
Honeywell V8043F
Zone Valve sold separately
Trade Price each $25.00
'W See page 48
For comDlele specifications refer to Technical Catalog Bulletin Form No 2560*2 (1 69)
Page 33
15676
HH-O-
CONTROL SETS, CONTROLS
^AMERICAN eiSTANDARD
HYORONIC HEATING
CONTROL SETS FOR BOILER-BURNER UNITS
Control set
no. 1 steam
no. 2 steam
for boiler without domestic hot water
boiler with year-round domestic hot water, tankless heater
no. 3 gravity water
no. 4 forced water
briler without domestic hot water, immersion control
boiler without domestic hot water
no. 5
V-3, V-3M, A-5, FR-A-5 units only with
forced water year-round domestic hot water
no. 5-Z forced water
V-3, V-3M, A-5, FR-A-5 units only. (1 no. 5-Z set is required for each zone in addition to the first zone which is controlled by the no. 5 control set or equivalent.)
control number
TS220 PA404A
T822D PA404A L4006A
T822D L4080B
T822D L408IB
T8220 L8124C
T822D R845A
contents of control set
description
Thermostat Pressuretrol
Thermostat Pressuretrol Aquastat operating control
Thermostat Aquastat limit control
Thermostat Aquastat limit and circulator control
Thermostat Aquastat limit, reverse and operating control, circulator relay
Thermostat Relay
edd to Trade Price of oil basic control set
$16.90
$12.15
$25.85 $30.05
number
description
T822D ? TS822A T882A* L4006A L4006E L4081B L4080D L4080B L6006A
L8124C L8124B
L8124E
L404C L604A L8148E
thermostat, adjustable heater 0.18 to 0.8 amp.
thermostat, millivolt
thermostat, electric clock Aquastat operating control Aquastat operating control; locks out on high limit settirg; manual reset
Aquastat limit and circulator control
Aquastat limit control Aquastat operating and circulator control Aquastat limit, reverse and operating control, circulator relay:
line voltage burner control, horizontal case for gas or oil millivolt burner circuit for gas with manual-auto switch, vertical case
low voltage burner circuit for gas, vertical case. Power for 2 zone valves
Aquastat-relay combination, high limit and line voltage circulator control. horizontal case: Pressuretrol w/man. reset SPDT operating controller low voltage burner control for gas. Power for 2 zone valves.
L8148G
millivolt burner control for gas. Power for 3 zone valves.
CONTROLS
^ Trade Price
number
description
Trad* Price
$ 7.70 7.70
37.20 16.90 19.40 25.15 13.00 13.00 17.95
38.85 36.30 38.15
34.20 33.95 24.40 26.85
PA404A RA89A RA832A R845A R8226B R81820
R8182E
R8182F
R8184G
120320
Pressuretrol
relay, SPST relay, DPST relay, DPST
Transformer and circulator relay
Aquastat-relay combination, high and low limit; providing room thermostat control of circulator: light sensing primary control, less cad cell; safety switch timing 70 seconds. For use with tankless.
Aquastat combination, high limit: providing room thermostat control of circulator: light sensing primary control. less cad cell; safety switch timing 70 seconds. For use less tankless.
Aquastat combination, high limit: providing room thermostat control of burner and boiler water temperature control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless.
light sensing primary control, less cad cell:
control number
safety-w*tch tlming-eecond* gph
R8184G1005
60
R8184G1021
30
R8184G1013
15
cadmium sulfide cell only
3 3-7 7-20
$19.35 17.75 22.35 22.35 13.00
58.20
56.50
50.55
30.55 34.45 34.45
2.40
`To substitute T882A* for T822D Thermostat; specify on order control set with suffix "B" and add difference to trade price from above.
HH-75-1 See page 48
Accessories and controls included in this price book are for use In conjunction with American-Standard products. Page 34
15677
^AMERICAN csiSTANDARD
HYORONIC HEATING
hydronic assembling
TOOLS
PACKAGED HYDRAULIC ASSEMBLING TOOL: All necessary parts to assemble any American-Standard sectional boiler, except long tie rods, shipped in one packing case; the long tie rods are furnished in their own wooden box. Total weight approximately 250 lbs.
Trade Price - $700.00
HEATRIM COPPER TUBE BENDING TOOL: Designed to bend riser tube connections for Model R Heatrim baseboard panels. Complete instructions for tool use included.
Trade Price each -- $18.50
HEATRIM RISER HOLE TEMPLATE: This tool accurately and quickly lo cates riser hole locations for Model R Heatrim panels. Consists of template (two pieces), 8 ft. steel tape and com plete instructions.
yr Trade Price each -- $3.50
ALUMINUM NIPPLE-SETTING-HAMMER:
--consists of a 2 lb. 1'k" diameter aluminum head and a 14" long hard wood handle. The aluminum head will not damage the nipple edges and per mits the heavy blows necessary to set nipples to the recommended depth quickly.
Trade Price each -- $5.80
SECTION BUMPING BLOCK: -- made of a 6" x 6" x 18" hardwood block with a convenient steel handle for swinging the tool. Its purpose is to bump a sec tion onto the pre-set nipples of the previous section to the recommended depth, prior to pulling the section up.
Trade Price each -- $17.05
TT See page 48
Page 35
15678
HH-75-1
PACKAGED BOILERS ELECTRIC WATER
fSI AMERICAN LSISTANDARD
HYDRONIC HEATING
PACKAGED ELECTRO-HYDRONIC BOILERS
ELECTRA ^
ELECTRA II
ELECTRIC CENTRAL HEATING BOILER WITH INTEGRAL LIMIT CONTROL
. E 38076___________ No ooo ooo,
Pre-wued for 240 volt, three wire, 60 cycle, single phase service.
Designed and equipped with con trols for forced circulation.
Tested and equipped for 30 lbs. water working pressure.
packaged boiler number
EP-34 EP-51 EP-68 EP-82
number of
elements
2 3 4 5
output watts
10.000 15,000 20,000 24.000
output btuh
34,130 51,195 68.260 81,912
mp 240 volts
41.7 62.4 83.2 100.0
Trade Price with atenderd
aquipment
$541.00 559.00 582.00 603.00
approi. hipping weight
98 99 100 102
Output ratings based on 240 volts. Reduce output ratings for other voltages as follows: 230 volts, 8% ; 220 volts, 16% ; 208 volts, 25%.
ELECTRA II--WATER
packaged unit
number
number
of elements
EP-7 EP-10 EP-14 EP-17 EP-20
i i i
i i
output wetta
2,000 3,000 4,000 5,000 6,000
output
btuh
6.826 10,236 13,648 17,060 20,472
amps # 240 volts
8.34 12.50 16.65 20.81 25.00
Trad* Prica with standard
equipmant
$270.00 270.00 270.00 270.00 270.00
approx. hipping weight
49 49 49 49 49
Standard Equipment
ELECTRA
T822D thermostat AT72D low voltage transformer R8154 sequencing control L4008J adjustable immersion type
limit control Allen-Bradley 836CP11-HKAZS
high pressure switch with EP-68 and EP-82 only
J. W. Hobbs M4440 low pressure switch
L V4 " circulator Expansion tank (diaphragm type)
Automatic air vent ASME relief valve Pressure and temperature gauge Drain valve
ELECTRA Optional Equipment
Sequencer Package: Available for field installation on EP-68 and EP-82 Boilers in addition to regularly furnished sequencing relay. Package con tains all necessary equipment and instructions for the installation of one (EP-68) or two (EP-82) 24A11-4 Sequencer(s) provides a 45 second current delay between the third and fourth elements of the EP-68 or be tween the third, fourth and fifth elements of the EP-82. Standard R8154 relay provides a 1/120th of a second (`a cycle) current delay between each
element.
Saquancar Package
Trada Prlca
EP-68 EP-82
$15.55 30.05,
Note: Zone valve packages are available for water boilers. For details and prices, see page 33.
ELECTRA II T822D thermostat Circulator with piping Drain valve ASME relief valve Pressure and temperature gauge Expansion tank (diaphiam type) L4080D immersion limit control J. W. Hobbs M4440 low pressure switch Automatic air vent
15679
HH-75-1 See page 48
Page 36
For comofete specifications refer to Technical Catalog Buiiet-n Fom No 2'29-2 iDev 3 70i . 315*2 iRev 4 9 '0i
I AMERICAN L2J STANDARD
HYDRONIC HEATING
HEATRIM PANELS
MODEL R HEATRIM PANELS
SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For Vi" Model R-750 and Vi" Model R-50.9 Panels)
DESCRIPTION
ordering number
packaged
MODEL R-750-A COMPLETE ASSEMBLED UNITS (Single Pack)
includes 1 each of front and
back panel,
element,
damper, support
brackets, slide cradles and
1 set joining pieces. (See
Mote #1) Finished with
white prime paint. All
factory assembled.
Box Color Coded-Red Orderlies Example:
1-box R-750-A4
R-750-A2 R-750-A3 R-750-A4 R-750 A5 R-750-A6 R-750-A7 R-750-A8
'per lineal foot
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
Trad* Pric*
approx.
hwiepipgihntg
$ 2.65
$ 5.30 7.95
10.60 13.25 15.90 18.55
2120
5 7 9 12 13 16 18
MODEL R-500-A COMPLETE ASSEMBLED UNITS (Single Pack)
includes 1 each of front and back panel. 4" element, damper, support brackets, slide cradles and 1 set joining pieces. (See NoteAtl) Finished with white prime paint. All factory assembled.
Box Color Coded--Green
Ordering Example:
1--box R-500-A3
R500-A2 R 500 A3 R-500-A4 R-500-A5 R-500-A6 R-500-A7 R-500-A8
'per lineal foot
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
MODELR ENCLOSURE ONLYASSEMBLED (Single Pack)
includes 1 each of front and back panel, damper, support brackets, slide cradles and l set joining pieces. (See Note #1) Finished with white prime paint. All factory assembled.
Box Color Coded-Black
Orderini Example:
1-box R-3-A
R-3-A R-4-A R-5-A R-6-A R-7-A R-8-A R-10-A R-12-A
'per lineal foot
3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 10 ft. length 12 ft. length
$ 2.52 $ 5.04
7.58 10.08 12.60 15.12 17.64 20.16
$ 1.30 S 3.90
5.20 6.50 7.80 9.10 10.40 13.00 15.60
5 7 9 11 14 15 18
6 8 10 11 13 15 17 19
MODEL R ENCLOSURES ONLYUNASSEMBLED (Bulk Pack)
includes 3 sets of front and back panels, dampers with Hips, support Drackets, slide cradles and 2 sets of joining pieces. (See Note #1) Finished with white prime paint. Unassembled.
Box Color Coded-Blue
Orderini Eixmpte:
1-box R-5-B
R-3-B R-4-B R-5-B R-6-B R-7-B R-8-B R-IO-B R-12-B
'per lineal foot
$ 1.17
three 3' lengths thre.: 4' lengths three 5' lengths three`6' lengths three 7' lengths three 8' lengths three 10' lengths three 12' lengths
$10.53 14.04 17.55 21.06 24.57 28.08 35.10 42.12
For comparative and estimating purposes only. Hole #1: Joining pieces not included on 2 ft. or 3 ft. sections.
15680
w See page 48
Page 37
Fcr complete soecificahons refer to Tecrrmca1 Catalog Bulletin Form No 1140-2 (Rev 2 22i
16 21 26 30 35 40 48 58
HH-75-1
HEATRIM ELEMENTS AND ACCESSORIES
rSl AMERICAN LSJ STANDARD
HYORONIC HEATING
MODEL R HEATRIM ELEMENTS AND ACCESSORIES
mm Jftllllllllllliri
DESCRIPTION
E-750 f3*" tube* ELEMENTS ONLY 'Bulk Pack) Individuallv boxed and strapped into a bundle of six equal lengths. Ordering Example:
1 -bundle E-750-3
ordering number
E-750-3 E-750 4 E 750-5 E-750 6 E-750-7 E-750 8
packaged [ Trade per i Price
per lineal foot $ 1.43
six 3' lengths six 4' lengths six 5' lengths six 6' lengths six T lengths six 8' lengths
$25.74 34.32 42.90 51.48 60.06 68.64
approx. shipping weight
9 12 16 18 22 25
E-500 ('V tube) ELEMENTS ONLY 'Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths
Ordering Example: 1-bundle E-500-4
E-500 3 E-500-4 E 500 5 E-500 6 E-500-7 E 500-8
per lineal foot S 1.30
six 3' lengths six 4' lengths six 5' lengths six 6' lengths six T lengths six 8' lengths
S23.40 31.20 39.00 46.80 54.60 62.40
8 10 12 16 19 21
ACCESSORIES
End Cap-3" wide-Right Hand End Cap-3" wide-Left Hand Valve Enclosure-4" wide--Right Hand Vahe Enclosure-4" wide-Left Hand Valve Enclosure-6" wide-Right Hand Valve Enclosure-6" wide-Left Hand Inside Corner-hinged front and top-90 Inside Corner-back piece-900 Inside Corner-one-piece front and top-l35a , 45 Inside Corner-back piece-l35/45 Outside Corner-90o Outside Corner-135/45 Filler piece set-7" wide Filler piece set-14" wide Wall End Piece-3" wide Return tubing wire hangers Connecting tubing wire hangers Joining piece set-2" wide Extra support brackets with slide cradles and damper
clips Tube bending tool
NOTE: F mished with white prime paint.
RA-ECR-03 RA-ECL-03 RA-VER-04 RA VEL 04 RA VER-06 RA VEL-06 RA ICF-90 RA ICB 90 RA-ICF-45 RA ICB-45 RA OCF-90 RA-OCF 45 RA-FPS 07 RA-FPS-14
RA-WEP-03 RA-WHR-50 RA-WHS-50 RA-JPS-02
box of 10 box of 10 box of 10 box of 10 box of LQ box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 5 box of 10 bag of 50 bag of 50 box of 20 sets
RA-SBP 20 box of 20 sets
_
*For comparative and estimating purposes only
NOTE: Add 25' . to price when ordennc in less than quantities indicated above.
$10.84 10.84 14.67 14.67 22.41 22.41 13.38 4.27 13.34 4.07 16.01 18.68 10.80 8.26 5.60 2.67 2.81 9.41
6.93 18.50
4 4 9 9 10 10 3 4 2 2 5 3 9 9 4 -- -- 5
5 --
15681
HH-75-1 See page 48
s~ec * : ati ~ ^ s re`e'
Paqe 38
T :i 3 v >
9. ?' ~
*. : 'J0-3
m AMERICAN LSJstandard
HYDRONIC HEATING
HEATRIM PANELS
MODEL SS HEATRIM PANELS, ELEMENTS AND ACCESSORIES
SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For %" Model SS75 and 1" Model SS-100 Panels)
DESCRIPTION
MODEL SS-75 COMPLETE UNITS (Dual Pack)
Box includes 2 each of front and back panel, h " element, damper, support brackets and slide cradles and 1 joining piece set (see Note -1). Finished with off-white prime paint. Ordering Exampla:
1 -box SS-73-6
ordering
number
packaged
P*r
Trode Price
per lineal foot $ 4.07
approx
shipping
wetghi
SS-75-2 SS-75-3 SS-75-4 SS-75-5 SS-75-6 SS-75-7 SS-75-8
Two 2 ft. lengths Two 3 ft. lengths Two 4 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths
$16.28 24.42 32.56 40.70 48.84 56.98 65.12
14 20 26 33 39 46 52
MODEL SS-100 COMPLETE UNITS (Dual Pack)
Box includes 2 each of front and back panel. 1" element, damper, support brackets and slide cradles and 1 joining piece set (see Note =1). Finished with olf-white prime paint.
Ordering Exampla: 1-box SS-100-5
SS-100-2 SS-100-3 SS-100-4 SS-100-5 SS-100-6 SS-100-7 SS-100-8
*per lineal foot $ 4.57
Two 2 ft. lengths
Two 4 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft lengths
$18.28 27.42 36.56 45.70 54.84 63.98 73.12
14
20 26 33 39 46 52
MODEL SSI-75 COMPLETE UNITS (Single Pack) Assembled
Box includes 1 each of front and back panel. 4i" element, damper, joining piece set (see Note =1), support btackets and slide cradles. Finished with offwhite prime paint.
Ordering Example: 1-box SSI-75-7
SSI 75-2 SSI 75-3 SSI 75-4 SSI 75-5 SSI 75-6 SSI 75-7 SSI 75-8
per lineal foot $ 4.24
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
S 8.48 12.72 16.96 21.20 25.44 29.68 33.92
7 11 14
18 21 25 28
MODEL SSI-100 COMPLETE UNITS (Single Pack) Assembled
Box includes 1 each of front and back panel, 1" element, damper, joining piece set (see Note =1). support brackets and slide cradles. Finished with offwhite prime paint.
Ordering Example: I--box SSI-100-4
SSI 100-2 SSI 100-3 SSI 100-4 SSI 100-5 SSI 100-6 SSI 100-7 SSI 100-8
per lineal foot S 4.73
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
$ 9.46 14.19 18.92 23.65 28.38 33.11 37.84
7 11 14 18 21 25 28
NOTE #1: Joining pieces not included with 2 ft. or .'3 ft. sections.
For comparative ana estimating purposes only.
See page 48
Page 39 rc* zt^o'e'e sreci' ca|,crs *ere' :c T-?c--i C r
Pc'~i N: 9233-2
15682
HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES
{AMERICAN k5J STANDARD
HYDRONIC HEATING
MODEL SS HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES
Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools anti churthe The SS Heatrim is ideal for residential "lr>"1 to heat" areas such as bathrooms, hallwass. ett
DESCRIPTION
MODEL SS
ENCLOSURES ONLY
(Bulk Pack) Box includes 4 each of front and back panel, damper, sup port brackets, connecting tube wire hangers and 3 joining piece sets (see Note -1). Fin ished with off-white prime paint. Ordering Example
1--box SS-8
MODEL SSI
ENCLOSURES ONLY
(Single Pack) Assembled
Box includes 1 each of front and back panel, damper, joining piece set (see Note =1), sup port brackets and connecting tube wire hangers. Finished with off-white prime paint. Ordering Example:
1-box SSI-6
ES-75-8 (J/4" tube)
ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of H" element and slide cra dles. Ordering Example:
1-box ES-75-8
ES-100-8 ()" tube)
ELEMENTS ONLY (Bulk Pack)
Box includes eight 8 foot lengths
of 1" element
dles. Ordering Example:
1-box ES-100-8
and
slide
cra
ACCESSORIES
rdtrlnf
nwmbr
SS-3 SS-4 SS-5 SS-6 SS-7 SS-8
SSI-3 SSI-4 SSI-5 SSI-6 SSI-7 SSI -8
ES-75-8
ES-100-8
r Troa.
frit.
per lineal foot $ 2.15
Four 3 ft. lengths Four 4 ft. lengths Four 5 ft. lengths Four 6 ft. lengths Four 7 ft. lengths Four 8 ft. lengths
$25.80 34.40 43.00 51.60 60.20 68.80
per lineel foot $ 2.37
3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
$ 7.11 9.48
11.85 14.22 16.59 18.96
per lineal foot 1.98
Eight 8 ft. lengths $126.72
per lineal foot $ 2.42
R. H. 2%" End Covers (Extend to Floor) ..................................................... ...
L, H. 2ti" End Covers (Extend to Floor) .....................................................
R. H. 6" End Covers (Extend to Floor) ..........................................................
L. H. 6" End Covers (Extend to Floor) ......................................................... Inside Corner Covers ............................................................................................. . . R. H. Valve Enclosures with hinged access doer ...................................... ... L. H. Valve Enclosures with hinged access door ...................................... ...
Wall End Pieces (Extend to Floor) .................................................................. ...
Outside Corner Covers ...........................................................................................
14" Filler Pieces ......................................................................................................
2" Joining Piece Sets ...........................................................................................
Support Brackets, Slide Cradles, Damper Clips.........................................
Return Pipe Hangers .............................................................................................
Damper Joiners ...
.................................
.................................
Connecting Tube Hangers ...............................................
.................... . .
Not*: Add 25% to price when ordering in lest than quontitie* indicated above.
SS-ECR-25F SS-ECL-25F SS-ECR06F SS-ECL-06F
SS-IC-90 SS-VER-06H SS-VEL-06H
SS-WEP-25F SS-OC-90 SS-FPS-14 SS-JPS-02 SS-SBP-24 SS-WHR-50 SS-OJ-50 SS-WHS-50
for comparative and estimating purpose! only. Note #1: Joining pieces are not included with 3 ft. sections.
Box of 12 Box of 12 Box of 12 Box of 12
Box of 12 Box of 12 Box of 12
Box of 12 Box of 4 Box of 6 Box of 24
Box of 24 Box of 50 Box of 50 Box of 50
$18.70 18.70 22.70 22.70
9.35 40.05 40.05
6.65 16.05 16.05
6.70 13.30
6.65 5.00
8.00
shipping weight
31 42 52 63 73 84
11 14 18 22 25 29
42
9 9 7 7 5 13 13 4 5 14 4 10 1 1 3
HH-75-1 See page 48
Page 40
co-ceie specifications reier to Technical Catalog Bulletin Form No 9239-2 [Rev t 73i
15683
^AMERICAN iSdSTANDARD
HYORONIC HEATING
MULTIFIN CONVECTORS
TYPE K - STOCK MODEL - FREE STANDING Expanded prices For use on two-pipe steam and hot water systems only.
CONVECTORS
cabinet length inches
No. 4 depth (4Vi" cabinet)
unit 4.
It WfpMt
PPrei. thippiRf
weight
Trod* Price
20" cabinet height
No. 6 depth (6Vi" cabinet;
unit ne.
ft awtput
apprei. thippmg
weight
Trodt Price
No. 8 depth (8Vi" cabinet) No. 10 depth (10Vi" cabinet)
umr ne.
evtput
apprei. shipping
weight
Tredt Price
unir ne.
n ft
ewtput
eppree. thippmg ^Trede weight
20 420-20 24 424-20 28 32 36 40 44 43 56 64
10 6 13 0
18 $29.08 620-20 14.9 21 $32.29
20
30.88
624-20 18.4 24
34.87
628-20 22 0 27
37.53
632-20 25 5 29
40.19 832-20 31.7
33 $44.79
636-20 29 0 33
40.80 836-20 36 0
37
47.99 1036-20 45.5 42
640-20 32 5 34
45.39 840-20 40 4
39
51.25 1040-20 51 2
48
644-20 36 1 37
48.05
648-20 39 6 656-20 46 7
40 45
50.71 848-20 55.98 856-20
49 2 58.0
46 51
57.84 64.42
1048-20 1056-20
62.3 73 4
52 58
664-20 53 8 52
81.30 864-20 66 9
59
71.02 1064-20 84 5
64
$55.10 59.30
67.62 75.87 84.12
24" cabinet height
20 420-24 12 1 20 $30.22 620-24 17 2 23 $34.01
24 424-24
14.9
22
32.29
624-24 21 2 26
36.94
28 428-24
17 8
25
34.41
628-24 25 4 30
40.06
32
632-24 29 5 33
43.20 832-24 35 6
38 $47.72
36
636-24 33 5 35
46.12 836-24 40.5 40
51.38 1036-24 49 0
45
40
640-24 37.6 38
49.19 840-24 45.5 44
55.10 1040-24 55 2
52
44
644-24 41.7 42
52.25
48
648-24 45.7 44
55.24 848-24 55.4
50
62.43 1048-24 67.1
62
56
656-24 53 9 50
61.36 856-24 65-2
55
69.74 1056-24 79 0
64
64
664-24 62.2 57
67.55 B64-24 75 3
63
77.28 1064-24 91.0
71
$57.71 62.29
74.51 80.07 88.98
32" cabinet height
20
620-32 18.7 29
$35.08
24
624-32 23.1 32
38.40
28
628-32 27.7 36
41.79
32
632-32 32.1 40
45.12 832-32 40 9 45 $51.65
36
636-32 36 5 43
48.39 836-32 46.5
48
55.85 1036-32 55.0
54
$62.16
40
640-32 41.0 48
51.71 840-32 52.2
56
60.10 1040-32 61.9
59
67.29
44
644-32 45.4 56
54.97
48
648-32 49 8 58
58.30 848-32 63 6
65
68.55 1048-32 75 3
69
77.28
56
656-32 58.7 67
64.89 856-32 74.9
73
77.00 1056-32 88.7
76
87.25
64
664-32 67. B 71
71.68 864-32 86 5
76
85.66 1064-32 102 2
84
97.37
Pines and bushings are not legulaily furnished with Multitin Conveotoi s. hut are available for separate sale.
1" l1." l'n" Trade Price Each $.36
Notti For stock model cabinet extras, see page 41. Ordering Eumpie:
l-K-636-32 Multifin.
15684
"W See page 48
Paqe 41
For complete soecificatio^s refer to Technical Cataiog Bulletin Form No 162-2 'Rev 6 10.69)
HH-75-1
CONVECTORS
AMERICAN LSJ STANDARD
HYDRONIC HEATING
\\\\\WVXX
MULTIFIN CONVECTORS
Combination Price: Tlic actual output in square feet of catalog rating-Ste3m (215'Fl obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination The total price of each order equals the amount of catalog square feet ordered multiplied by fhe price per square foot, plus the unit extra charge multiplied by the total number of units Ordered.
SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS
cabinet tyoe
description
Trad# Pric#
Dr sq ft
1 unit #xtra charg#
Stock Model
K
Floor Type-free standing..............................................................
s.75
521.18
Note: Price shown for estimating purposes only. For expanded prices, see page 'v For cabinet ext ras see page i I
Special Service
F FG W
FS FSG
S
FR FRG FRGB
PR PRG
PRGB
Floor Type-free standing .......................................................... Floor Type-free standing-inlet grille...................................... Wall Hung-flat top..........................................................................
Free Standing-sloping top ................ ..................................
Free Standing-sloping top-inlet grille....................................
Wall Hung-sloping top.
. . ,.
................
Fully recessed-',*" beveled edges ............................................
Fully recessed-),,,'' beveled edges-mlet grille ..................
Fully recessed-',*" beveled edgcs-inlet grille with
bottom o\. erlap and liner bottom
.
Partially recessed-P-i". 2*2", 3". 5" flanged edges
Partially recessed-l'i". 2>2'', 3", 5" flanged edges-inlet
grille
....................................................
Partially rcccssed-112". 212". 3", 5" flanged edges-inlet
gnlle-with bottom overlap and liner bottom....................
S .89 .89 .89 .84 .84 .84
.91 .91
.91 .94
.94
.94
$25.66 29.49 25.66 27.07 30.90 24.39
27.07 30.90
34.02 31.33
35.01
44.94
llllllliiiiii
S^ ^43 43
Note: For cabinet extras, see page -II.
For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifin convectors:
Multifin stock model -- 1 13 pounds. Also see page 38.
Multifin cabinets (less elementi - 1V4 pounds.
Multifin cabinets (with element):
Types F, FR. PR -Impounds.
Types FS. W
-Impounds.
Type S
-Impounds.
Ordering Eiamples: Stock Model Multifin with an optional feature: 1 K-840-24 Muitilin with Metal Trim Strips.
Special Service Multifin with an optional feature1 PR-640 32-2'd Flange. Multifin with Knob Damper
15685
Pacje 42
^AMERICAN LSi STANDARD
HYDRONIC HEATING
MULTIFIN CONVECTORS - continued
CONVECTORS
convector length Inches
20 24
28 32 36
40 44 48 56 64
Elements only (when sold less cabinets) -- two-pipe steam or hot water
No. 4 depth
No. 6 depth
No. 8 depth
No. 10 depth
unit no.
approx. shipping
weight
Trade Price
unit no.
approx. Shipping
weight
Trade Price
unit no.
approx.
shipping Trade
weight
Price
unit no.
approx. shipping
weight
Trade Price
420 424
428 432 436
440 444 448 456 464
8
$16.78
620
13
$20.57
820
15
$24.30 1020
10
18.17
624
16
22.57
824
19
28.08 1024
12
19.57
628
19
24.56
828
23
30.09 1028
14
21.03 632 22
26.29 832 27
32.75
1032
16
22.84
636 25
28.29 836 31
35.67 1036
18
24.56
640
28
30.69
840
35
38.20 1040
20
26.22
644
31
32.75
844
39
41.06 1044
22
27.75
648
34
35.00
848
43
43.73 1048
26
30.88
656
40
39.00
856
51
48.85 1056
30
34.14
664 46
43.46 864 59
54.11
1064
Note: Elements only are furnished less floor supports. Multifin elements for special one-pipe steam header application--not available.
Ordenne Example: 1-420 Multifin Element only-no cabinet.
21 26
31 36 41
46 51 56 66 76
$27.95 32.42
36.15 39.67 43.79
47.26 50.58 53.77 59.90 67.22
Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee.
Standard Cabinets: Suimlaiil cabinets aie furnished in prime painted sheet steel--reinforced. No. 18 gauge front and No. 20 gauge back, etuis and top, rounded corners, fiont discharge grille, and open bottom inlet, in heights, lengths and depths to accommodate convectors as cunentlv catalogued.
HH-O-l
MINIMUM CABINET HEIGHTS WITH DAMPERS FOR MULTIFIN
Typg cabinet
F, EG W FS.FSG S FR, FRG, FRGB PR, PRG. PRGB
Cabinet heights shov-n for types W and S
Multitin
20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths
nominal heights, actual heights are 5" less.
15686
eaqe 43
See page 48
CONVECTORS
^AMERICAN IS STANDARD
HYDRONIC HEATING
CABINET EXTRAS FOR MULTIFIN
CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY
ITEM
DESCRIPTION
DAMPER
Knob Operated Damper Package ......................................
METAL TRIM STRIPS
For recessing stock models only
20" to 36" long
..............................
40" to 64" long ........................................................................
GRILLE
Snap-on Inlet Grille for Stock Models Only ................
AIR VENT
Air chamber with extended tube, manual vent . . Air chamber with Dole No. 20JR auto-vent....................
'Note: Items also available for special service Multifin.
each
.. each each each
. . each each
SPECIAL SERVICE CABINET EXTRAS-MULTIFIN (Prices indicated are 'or standard catalogued sizes only)
ITEM DAMPER
ACCESS DOOR
TAMPER PROOF SCREWS
CAM LOCKS
DESCRIPTION
Knob or Institutional Type .................................................................. each
In standard locations 1, 2, 3, 4, 7 or 8 as shown in current literature. Hinged type with Slotted Head operator .............................................. each Hinged type with Allen Head operator .................................................. each Note: Access doors in other than standard locations
Phillips or Allen Head screws (other than standard Slotted Head) per cabinet
Alien Head Cam Locks (Allen Keys Not Furnished):
Types F. FG. FS and FSG
....................
................ per cabinet
Types S and W (Multifin Only) ................
................ per cabinet
TypNeosteF:RA,dFdRitiGon. aFl RcGhaBrg, ePRpe. rPoRrGde. rPJR6.G29B
j ^
~pvetr0.4
ppeerrcc^imnee *
INSULATION
SOUND DEADENING MATERIAL
SEALING STRIP
STIFFENER
METAL TRIM STRIPS
END POCKETS KNOCKOUTS
HEAVIER GAUGE CABINETS
HH-75-1
Vfc" Celotex or Fibreglas on outside of cabinet Back only........................................................................................ per cabinet Back, ends andtop ..................................................................... per cabinet
l/z" Millboard on outside of cabinet Back only........................................................................................ per cabinet Back, ends and top................................................................... per cabinet
Approx. 1/b" thick--inside front panel only................................ per cabinet
For standard length FR, FRG and FRGB cabinets only
(W x
Polyurethane) .......................................................... per cabinet
All fronts 48" and longer, or 32" and higher have stiffening channel spotwelded to inside front in horizontal position at
no additional charge. Stiffening channel on fronts other than standard .............................................................................................. per cabinet
For recessing Types F and FG Multifin convectors only
Cataloged heights and lengths up to 36"............................................ each Cataloged heights and lengths 40" to 64".......................................... each
Specify right or left hand side
4" end pocket with No. 18 gauge vertical baffle............ per end pocket 8" end pocket with No. 18 gauge vertical baffle ............ per end pocket
Are optional-Furmshed only on request
Trade-Price per square foot of cabinet output ' Front Only
No. 18 gauge.......................................... No. 16 gauge ........................................
No. 14 gauge ........................................
-- $*10
-19
Page 44
Linen Only
S-I .12
--
Trade Price
$ 7.33
12.58 16.10
5.59 7.13 7.13
Trade Price
S 8.72
8.72 10.38 Price on application
1.41
7.18 7.18 31.68 39.67
14.77 18.24 34.61 49.19 14.64
6.13
2.07
14.11 17.38
7.85 12.58 Pnce on application
15687
!
rSl AMERICAN LSJ STANDARD
HYDRONIC HEATING
GENERAL INFORMATION
BOILER RATINGS
The net I = B --R boiler ratings represent the maximum net loads that may be connected to the boilers. The net I = B = R steam ratings are based on a piping and pickup allowance of 1.333 except where an appropriate piping and pickup column is shown. Steam sq. ft. ratings are based on 240 Btuh per sq. ft. The net I = B=:R water ratings in Mbh are based on a piping and pickup factor of 1.15. Water sq. ft. ratings are based on 150 Btuh ( 1 TO' water) per sq. ft. For installations having unusual piping and pickup requirements, AmericanStandard should be consulted before selecting a boiler.
For forced hot water heating systems where the boiler and
piping are within the area to be heated, the boiler may be selected on the basis of its gross output.
Sufficient radiation must be installed for the requirements of the building to be served.
In order to select the proper size boiler, calculate the heat loss of the building, then divide this figure by 1,000 to get the heat loss expressed in Mbh. Select a steam or water boiler which has a net I=B=R Mbh rating equal to or greater than this figure using the appropriate steam or water column.
GAS FIRED BOILERS
American-Standard Gas boilers are design certified by the American Gas Association.
Ratings shown are for installation at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
OIL FIRED BOILERS
The firing.rates or I=B = R burner capacities -- gallons per hour--are based on the use of oil having 140,000 Btu per gallon heat value.
BUILT-IN TANKLESS WATER HEATERS for G-2 Water, G-40, G-10, V-3, V-3M, FR-A-5, A-S, DPT, PFA-3, PFA-S, and VPT
All tankless type built-in water heaters are rated in gallons per minute on the basis of a minimum boiler water temper ature of 200" F. The maintaining of 200" F boiler water temperature with rated flow through a tankless type builtin water heater is dependent on the output of the boiler.
Increase the boiler size 12 Mbh for each bathroom in excess of two.
In those areas where excessive liming conditions exist in the water, use of built-in tankless type water heater is
not recommended except when provision is made for reg ularly cleaning the heater.
EXTERNAL WATER HEATERS FOR AMERICAN-STANDARD STEAM BOILERS
External tank or tankless type heaters can be connected to all American-Standard Steam boilers when provision is made in the supply and return piping of the heating system.
When an external tank type heater is used and the domestic demand exceeds 75 gallons in a 24 hour period, increase the boiler size 120 Btuh for each gallon of storage tank capacity.
When an external tankless type heater is used, increase the boiler size 12 Mbh for each bathroom in excess of two.
(Note: G-10 Steam boilers can be provided with external water heater tappings for water to water heat exchangers. See G-10 optional equipment Dages for price and availabil ity.
INSTRUCTIONS FOR ORDERING GAS BOILERS:
Specify complete boiler number. Specify type of gas (whether natural or propane), Btu (heat value of gas),
specific gravity.
Specify elevation at point of installation if in excess of 2,000 feet and indicate barometric pressure.
In oddition, for Prattura Firod PFA-5 gat firad and gat-oil firad unitt, tpacify gat prettura al gat train inlat.
Spacify optional equipment in detail
BOILERS:
REPAIR PARTS For current price, contact your American Standard distributor
Refer to Boiler Repair Parts Catalog Form 9100-2 & Revisions for Current Repair Parts
Obsolete and Discontinued Boiler Repairs are available thru:
H. C. Oswald Co. 120 E. 124th St. N.Y.C., N Y. 10035
OIL BURNERS:
Refer to "American Standard Oil Burner Repair Parts Catalog" 73197-2 dated July. 1974
See page 48
Page 45
15688
HH-75-1
HYDRONIC MATING NOTES
HH-75-1 See page 48
Page 46
15689
d AMERICAN STANDARD
HYDRONIC HEATING
NOTES
s
15690
GENERAL TERMS
AMERICAN STANDARD
f O >OX 2003. NEW 8BUNSWICX, N 1 08903
TRADE PRICE BOCK
Illustrations and descriptions of ordering Numbers listed in this price book will be found in the current American-Standard Hydronic Product Catalog and literature. Items illustrated in product literature and not included in this price book are discontinued The illustrations in this price book although actual representations of certain products in the line, do not necessarily show sizes and details of all products in the line.
vThis price list has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown are guides only and do not purport ._ epresent actual prices prevailing in any particular market and are not intended to interfere with our distributors' right and responsibility to establish their own resale prices.
All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein.
INVOICE MINIMUM All distributors' orders, including repairs, which aggregate less than $25.00 net will be billed at S25.00.
TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH U.S. PLUMBING/HEATING TO ITS DISTRIBUTORS
All sales of goods by American-Standard through WH Plumbing/Heating to its distributors are made subject to terms and
conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and
conditions, are as follows: PRICE
Since local code requirement vary greatly
\'a -ountfv use's
Goods sold by the Sollor will be billed to the Buyer according to the prices and terms contained in its current bulletins and price books. In the case of orders for goods for which no price is currently in effect the price will be determined by the Seller and set forth m the invoice issued after shipment of the goods.
Taxes. Any tax or other Government charge now or hereafter levied upon the production, sale, use or shipment of goods ordered or sold, will be charged to and paid for by the Buyer.
of heating producis should consult m advance v m ;<ce"sed
to determine whether ihere are any code resfnct'ons on
cf a
specific producf Amencan-Standard makes no representation nor war-
raniy regarding, and shall not be responsible for. any code compliance
American-Standard is proud of its record for product quality and for fair ness in handling warranty matters; and. if an ultimate user of our products should feel our warranty system described above does not work fairly in his case, he should write the Office of the President. Director ol Consumer
Affairs, W. H. Plumbing Heating. Amencan-Siandard. Box 2003. New
DELIVERY
Brunswick New Jersey 08903
Transportation Risks. Oelivery to the initial carrier shell constitute delivery
CONTRACT WITH BUYER
to the Buyer. The Seller's responsibility ceases upon delivery in good order to such carrier, and aU goods are shipped at the Buyer's risk.
Acceptance of Ordera. Orders will be accepted only by the Seller's usual acknowledgment of order containing terms and conditions applicable
The Buyer is urged to examine all deliveries carefully before signing
thereto. No terms and conditions appearing in a Buyer's order that are at
transportation receipts. If goods are visibly damaged, the Buyer should insist that written confirmation of the damage be noted on the freight bill or dray ticket by the agent of the carrier. If damage is discovered after unpacking, the carrier should be notified at once, so that inspection can be made and the claimed damage substantiated by the carrier.
Interference with Delivery. The Seller has no obligation to deliver goods against any order until it (tas accepted the order by issuance of its acknowl edgment of order. In any event, the Seller will not be liable for any delay or failure m the delivery or shipment of goods against an accepted order or for any damages suffered by reason thereof, when such delay or failure is. directly or indirectly, due to accident (jn manufacture or otherwise), fire, flood, not. war. embargo, labor stoppages, inadequate transportation facili ties. shortage of material or supplies, delay or default on the part of its
variance with the Seller s terms and conditions shall be binding upon the Seller unless specifically agreed to by it in writing Unless the Seller spe cifically so agrees in writing in acknowledging any order, any terms and conditions appearing m a Buyer's order contrary to those stated herein and in such acknowledgment of order are to be deemed waived by the Buyer Receipt by the Buyer of the acknowledgment of order without prompt objec tion to the terms and conditions therein and herein set forth, constitute acceptance by the Buyer of such terms and conditions.
Cancellation of Ordera. After the Seller's acknowledgment ol order has been issued, an order may be modified or cancelled only upon written agreement by the Seller. Orders lor goods other than those of standard manufacture will not be cancelled after a commitment has been made or production scheduled.
vendors, regulation by Government authority, or any. like or dissimilar causa
Credit for Returned Goode. Merchandise may not be returned for credit
beyond its control.
unless the Seller has agreed to accept it. Where returns are accepted, a
CONSUMER PROTECTION - WARRANTY
deduction of 20% or $20. whichever is greater will be made for rehandling All transportation costs for returned goods must be paid by the Buyer. In
American-Standard products normally reach owners or consumer-users through an industry channel of distributors and plumbmg and heating con
tractors. Experience has shown that claims of delects in our products gen erally relate to abuse or to other damage which occur after our sale and are not our responsibility. Since determining proper responsibility requires local inspection, our warranty (set forth below) extends only to our direct buyers; distributors are best equipped to obtain the facta underlying claims, to place
any event, only saleable merchandise of standard manufacture may be returned tor credit.
Credit Approval. Buyers' orders are accepted subiect to credit investiga tion and approval, and delivery may be withheld or shipment stopped in transit on accepted orders without any liability on the Sellers part. if. m its opinion, the Buyer's ability to pay lor the merchandise on these terms and conditions is m doubt.
responsibility where it belongs and to recommend/handle repair or re placement.
SHORTAGES OR VARIANCES
American-Standard warrants only to its distributors and other Direct Buyers that, at its option, it will lurmsh by freight a replacement for, or repair, or refund the purchase price paid by its distributor or other direct buyer, for any product ol its manufacture or part or portion thereof, proved to its satisfaction to be defective m material or workmanship under normal use and service within one year after installation In no case will American-Standard be responsible for any special, direct, in direct, or consequential damages nor for labor or transportation ex penses relating to such replacement or repair, nor will it be held re sponsible for warranty adjustments costing more than the price of the product to its distributors and other Direct Buyers.
There it no other warranty, expreaa or implied. including no implied warranty of merchantability or implied warranty for fitness for a particular purpose.
No claims for variances from or shortages m orders will be considered unless presented within 60 days after receipt of goods.
PRODUCT AND PACKAGING CHANGES
Factors beyond the control of the Seller and the need for continuing im provement of product require the making of changes Irom time to time in products and their packaging. The right is reserved to make reasonable changes of any kind without notice and to deliver revised designs or models of goods against any order, unless on the face of the acknowledgment of order this right is specifically waived.
The Seller shall have no responsibility whatever with respect to changes made by the manufacturer in products or their packaging sold but not manufactured by the Seller.
Goods of other manufacturer* sold by American-Standard are not warranted unless accompanied by an express written warranty, but the Seller will endeavor to secure for its direct Buyers the benefits ol warranties extended by euch other manufacturers for such goods.
SHIPPING WEIGHTS
The shipping weights given herein are approximate lot Buyers' con venience only, and are not guaranteed.
AMERICAN STANDARD Inc.
HH-75-1
Page 48
15691