Interoffice Communication
to J. A. De Bernardi From P. L. Fetzer Date December 18, 1979 Subject Deregulation of Area No. 5 - EDC Tank Tops
The data developed by Jay Zimmer during the summer indicated that all tanks except T-453 could be deregulated based on the 8-hour test data. However, since employee exposure occurred within a 15-minute time period, the exposure data for this time period was developed. The earlier data summarized
below showed that all tank tops except T-453 and T-402 were below the 5.0 ppm VCM 15-minute maximum exposure value.
ppm VCM
T-402 5.39
T-405 1.20
T-460 2.81
T-450 0.28
T-451 4714"
T-452 3.99
T-453 22.8
Tanks T-402 and T-453 were retested following mechanical check-out and completion of any required maintenance work. Six 15-minute testings of each tank were completed. The average.value of the composite testings is 1.2 ppm and 0.52 ppm respectively for tanks T-402 and T-453.
Personnel exposure data for the Pumper-Loaders Offsites whose duties require them to be atop of the EDC tanks are tabulated beTow. The high values are not attributed to helping the pumper-loader on the loading rack. Two exposures occurred on the shift where the pumper-loaders are atop the EDC tanks but one was attributed to general high area levels and the second to loading a light ends tank car.
0.0-0.5 21
0.5-1.0 2
ppm VCM 1.0-2.0
1
2.0-3.0 0
3.0-4.0 0
4.0-5.0 2
The original basis for the regulated area was due to the vinyl in the vent gas being omitted atop each tank. Now all EDC tanks are vented into a vent system that is connected to the incinerator reducing exposure atop the EDC tanks. Those maintenance problems which were corrected atop T-453 directly led to the reduction of the recent 15-minute test data.
Based on the recent test data, the EDC tanks T-402 and T-453 should be dere gulated. All other tanks should be deregulated on the basis of the earlier data.
Paul L. Fetzer
PLF:lad CC: GLF, WVH, HDG