Document g27R6ko5EN3oVmN056LoKQ8La
Heating Systems Burners, Gas
The Barber Gas Burner Company
3704 Superior Ave., Cleveland, Ohio
Address Michigan inquiries to The Barber Gas Burner Co., of Mich., 4475 Cass Ave.. Detroit. Mich.
Barber Automatic Jet Gas Conversion Burners, for heating and air conditioning
equipment, have a record of high efficiency, for a period of over 20 years, giving con tinuous satisfaction in many thousands of homes and other buildings in United States and Canada. The exclusive Barber Jet principle of combustion, attaining 1900 deg
flame temperature on atmospheric pressure, and other basic advantages of design, have, given Barber a permanent place in modern heating and air conditioning practice. Barber Burners for gas burning appliances have been adopted as standards by many appliance manufacturers. Shown here are only a few items from Barber's complete
line. Illustrated No. 38A Catalog and Price List furnished on request.
-5%------- =---------
10"'
Heating Systems Burners, Gas
The Webster Engineering Co.
419 West 2nd St., Tulsa, Oklahoma
Division of SURFACE COMBUSTION CORP-, TOLEDO, OHIO
WECO-N.G.E. SERIES F600 GAS BURNERS
50,000 to 10,000,000
Btu Output
No. C. L-90 Burner Unit
Conversion Burners for Furnaces or Boilers
Burners are adjustable as to diame ter, on the job, to fit practically all round grate sizes. Also to fit grates of oblong furnaces and boilers. Listed in the A.G.A. Directory of Approved Ap pliances. Equipped with automatic controls with motor gas valve, with magnetic gas valve control, with quick acting gas valve control (for buildings equipped with automatic heat control), or in "M" series with manual control.
Barber Burners and Regulators are Adaptable to: Air Conditioning Equipment, High Pressure "Boilers (Tubular and Tubeless), Bakery Ovens, Garage Heaters, Coffee Urns, Hair Dryers, Space Heaters, Floor Furnaces, Clothes Dryers, Water Heaters, Confectioners' Stoves, Vulcanizing Machines, Pressing Machine Boilers, Japanning Ovens, Core Ovens, Banana Room Heaters, Other Appliances.
Gas Burner Specialists offering Engineering Department and Laboratory facilities for Gas Burner problems. Consultation invited.
992
For Use in Any Steel
171 maVav
The Series F600 venturi tube is
6M' wide,
long, as shown
(at right) and the complete
assembly is only 15' high. An
infinite number of assemblies
are possible by proper arrange
ment of the individual tubes.
For complete sizing information
see Bulletin F600H.
Improved venturi and greater port area insure much higher capacities at lower pressures. .
Unique baffles at the outlet of the mixing
tube make possible perfectly even distri
bution of flame completely around the baffle brick. As a result the maximum flame length is greatly reduced.
Interchangeable grills with multiple ports can be varied to suit the combustion char acteristics of various gases. The proper
sizing of these grills prevents any possi bility of flash back.
In addition to the above major improve ments the F600 possesses the same desir
able features that made the 600 so popular. 1. Simple installation requiring no ex
pensive insulated combustion chamber and having no furnace radiation loss.
2. Extreme quietness due to low rate of
combustion over a large area.
3. Flexibility from infinite number of
possible combinations varying both size and shape to meet load and firebox con ditions at various gas pressures.
4. High radiant transmission rate due to
radiant temperature of the standard fire brick baffles on the top of the burner tubes.
5. Low draft loss because of ample secondary air openings.
6. Plain gas pilots of heat resistant material and of a design that will hot allow flame to pull off.
7. Safety pilot applied in a cool , zone in a manner that insures perfect direct ignition of the burner yet allowing the
the thermal element to cool quickly upon flame failure.
8. Guaranteed vibrationless under all
conditions.
CAPACITY OF SINGLE F600 VENTURI TUBE--No. 16 M. T. D. ORIFICE
Manifold Gas Pressure
0.5' W.C.
Input--Cu Ft, 1 hr... 26.5
Output--Sq Ft, St. Rad 81
Output--Boiler HP... 0.58
1.0* W.C.
40.5
124
0.89
2.0' W.C.
60.5
165
1.33
3.0' W.C.
75.0
229
1.65
4.0' W.C.
87.0
267
1.91
5.0* W.C.
6.0' W.C.
98.0 108.0
301 331
2.15 2.37
4 02
116.0 355 2.54
6 02
143.5 440 3.14
8 02
166.5 510 3.66
993