Document g20V9DgZN8ZbN6Yv6yeLG6ykG
Heating Ventilating Air Conditioning Guide 1950
Conductivity (contintted)
homogeneous materials, 171 insulating materials, 173*176,
179. 578
insulation blankets, 175, 180 insulators. 173-176, 578 loose-fill insulation, 176 masonry materials, 173, 180 plastering materials, 174, 180 ' reflective insulation, 172, 180 rigid insulation, 175, 181 roofing construction, 174, 181 woods. 174, 181 Conductor, 3 Conduits for piping, 593
Control, controls actuated, 806 actuating, 806 airborne infection, 135 all-year conditioning, 602, 810, 812 application, 812 automatic, 429, 805 fuel appliances, 337, 805, 808 temperature, 805 basic types, 805 central fan system, 602, 814 all-year system, 601, 805 heating cycle, 607coal fired plant, 808 cooling units, 812 dehumidification, 813 dehydrating equipment, 799, 801 designation, 805 draft. 324 electric heating, 809, 865 equipment for motors. 819 fan, 686 gas burner, 808 gas-fired appliances, 344, 808 heating unit, 808 hot water supply, 994 humidity, railway cars, 964 indicating, 818 individual rooms, 806 limit, 809
' modulating, 805 motor, 837 oil burners, 808 panel heating, 817 pneumatic systems, 805 rate of biochemical reactions, 912. rate of chemical reactions, 912 rate of crystallization, 913 recording, 818 refrigeration equipment, 813 compressor type, 813 ` ice cooling, 776, 813 well water, 813 regain, 910 residential systems, 808 room thermostat, 809 service water temperature, 994 single phase motor, 827 small buildings, 808 sound, 843 squirrel-cage motor, 834 stoker, 337, 808 system control, 809 terminology, 805 two-position control, 805 unit cooler, 812 unit heaters, 812 unit systems, 812 unit ventilators, 812 valves, 4S5, 571, 807 ventilator, 217 volume, 635 sone, 603, 810
Control, controls (continued)
Controllers, 805 functions, 805 * types, 805
Convection. 3, 101,105 equation, 103
unit conductances, 104
Convector, convectors* 3, 503,
507
correction factor, 509
heat-omission, 503
heating effect, 508,
induction. 609
ratings, 508
Converging vanes, 625
Conversion
burners, 337, 345
equations, 15 *
Coolers, 545, 551, 555
Cooling, 249, 545 air conditioning units, 545 atmospheric water, 7,09, 724 coil selection, 743
evaporative, 611
load, 56, 271, 606 methods, 439 performance of coils, 735 ponds, 717
residential, 439 sensible, 611 spray, 602, 611, 717
effect of wind, 718, 721 make-up water, 733 size of equipment, 709
winter freezing, 733 systems, 439, 611, 962 tower design, 726
tower performance, 728 units, 545
component parts, 546 control, 552
definitions, 545 defrosting, 556 design, 555 performance, 555
ratings, 552 remote, 547 types of, 556 water, 725
water piping, 986
Copper elbow equivalents, 487 Core area, 618 .
Corrosion, 547, 873
air ducts, 889
^
atmospheric,' 888
cathodic protection,'891
coal storage equipment, 889
cold water, 884
flues, 689
hot water, 885
industrial exhaust systems,
931
minimizing condensate, 886
pipe, 890
prevention, 886
refrigerating systems, 885
underwater, 883
Cost of air conditioning, 895
amortization, 895
condenser water, 905
first, 895
fixed charges, 895
heating, 906
installed, 897
insurance, 901
Cost of air conditioning (con tinued)
maintenance, 901
owning and operating, 895
rent, 901
service, 903
'
Crack length
used for computations, 207,
241
Crystallization
control rate of, 913 .
Cylinder dryer, 954
D
Dalton's rule, 23, 65* Damper, dampers, 427, 601, 634 Darcy formula, 77 Decibel, 843 Definitions, 1 Defrosting, 556
Degree-day, 3, 402,404
for cities, 404 formula for, method, 403 operating unit, 412 unit fuel consumption, 407 Degree of saturation, 8, 36
Dehumidification, 605, 713. 795
air conditioning unite, 547
air washers, 713
coil selection, 743, 754
comparison of methods, 795
control, 799
definitions and methods, 795
equipment, 799, 801
performance, 799, 801
estimating loads, 802
liquid methods, 800
ships, 973
solid methods, 797
--
Dehumidifying agents, 795
sorbents, 795
absorbents, 795
adsorbents, 795 -
-Density of air, 1, 24
Design conditions
summer, 250, 251
winter, 226
Dew-point
apparatus temperature, 54,605
flue gas, 326
temperature, 9, 54. 913
Dichlorodifluorometnane, 761,
763
Direct
expansion coils, 738 fired unit heater, 531
indirect heating unit, 3 radiator, 7, 503 return system, 3, 492 Disc fan, 690 Distribution of air (see Air Dis
tribution), 418, 425, 61.7
District heating, 591 automatic control, 817
glossary of rate terms, 599 meters, 597 piping, 591
conduits for, 592, 693
inside, 595 overhead distribution, 595
sizes, 593 .
tunnels, 595 types of, 591 . rates, 599
steam requirement, 599
XIV
Index to Technical Data Section
Diverging vanes, 625 __
Domestic oil burners, 337
Door, doors
.. .
coefficients of transmission,
196 ' leakage, 205, 207, 209
natural ventilation, 205, 217
Down-Feed
.
system, 4, 445 j
Draft, drafts, 4, 379, 618
available, 381, 388
calculations, 379
..
chimney, 379
.
control, 324
factors, 380 general equation, 379
head,4 _ mechanical, 379
natural, 211. 379
regulation, 324
requirements, 324, 380, 391
theoretical, 379
Drawing symbols, 17
Dry air, 1 composition, 23, 312 density, 24 filters, 696 properties of, 23 velocity head, 649
Dry-bulb temperature, 9 Dry cooling coils, 611, 735, 749 Dry return, 8, 443
Dryer, dryers cabinet, 954 calculations, 948 compartment, 954 cylinder, 954 drum, 953 rotary, 954 spray, 955 tunnel, 954
Dryer calculations, 943
Drying. 912, 933 application of hygrometry, 947 'calculations, 948 chart, 947 conduction, 953 oonstant rate period, 937, 939, 941 convection, 953 control, 951 effect of air velocity, 938 equations, 944 equilibrium moisture, 945 example, 956 external conditions, 935 factors influencing, 934 falling rate period,' 941 internal conditions, 935 mechanism of, 934 methods, 952 conduction, 953 convection, 953 radiant, 952 periods, 936problem, 956 radiant, 953 surface temperature, 938 systems, 933 terminology, 933
Duct, ducts. 418, 428, 641 air velocities in, 426, 657, 927 approaches to outlets, 633 area change, 651 attenuation, 851 circular equivalents, 646 construction details, 665 design, 418, 428, 641 design methods, 658-665 elbow friction losses, 650, 930 exhaust design, 919 friction losses, 641 heat loss coefficients, 668 lining, 854 measurement of velocities, 1005 noise transmitted, 427, 845 pressure loss, 641 recirculating, 417, 419, 426, 636 rectangular equivalents of * round, 645 resistance, 641, 930 roughness correction, 644 side outlets, 634 sizes, 641 sound absorbers. 852 symbols for drawing, 18 system design, 418, 428, 641
Duct gizingr 641, 658 equal friction method, 659 general rules, 418. 429, 656. static regain method, 661 . velocity method, 658
Dust, 4,153 combustible. 163 concentrations, 157 determination, 156 filters, 693 precipitators, 703 removal, 702
Dust collectors, 693, 703 application, 703 centrifugal, 705 cinder catching, 706 cyclone, 705 dry dynamic, 705 high efficiency, 705 electrostatic, 703 fabric, 704 factors affecting selection, 702 settling chambers, 706 testing methods, 706 wet, 704 centrifugal, 705 disintegrator, 705 dynamic precipitator, 705 orifice type, 705 packed tower, 705 washers. 704
Dynamic head, 5, 649 losses. 646
EDR (Equivalent direct radia tion. 7.361, 454, 458, 460, 503
defined, 7, 361, 503, 507
Effective temperature (see Tem perature), 9, 123, 126
chart, 129 index, 126 Ejector nozzles, 630 Elbow attenuation, 851, 852 copper equivalents, 487. '
Elbow (continued)
friction lasses, 459, 487, 984 iron equivalents, 459, 487, 984 sheet metal, equivalent, 419,
432, 650, 651, 930
Electric, electrical air conditioning, 867 boilers, 867, 868 control systems, 805 heaters, 865 conduction, 865 gravity convection, 866 radiant, 866 heating, 865 calculating capacities, 870 oentral fan, 866 oontrol. 866 domestic water, 809 dements, 865 induction, 870 power problems, 871 resistors, 8, 865 hot water hasting, 868, 869 motor design limits, 620 panel heating, 520 precipitators; 703 radiant heating, 520 ' resistors, 865 systems, 819 voltage ratings, 820 unit- heaters, 886
Electricity static, 914 Emissivity, 107, 109, 172, 618 ' factors, 107{ 518 Enclosed radiator, 507
Enthalpy, 4, 35 free, 4 specific, 4, 35
Entropy, 4, 35, 50 mixing, 50
Equivalent evaporation, 4 Estimating fuel consumption,
Eup&theoscope, 527, 1014
Evaporative condensers, 781 cooled, unit conditioners, 553 cooling,'611
Evaporators, 783
Excess air. 315, 343, 347 Exhaust opening, 635, 636, 920
measurement of velocities, 923, 1009
- Exhaust systems, 919 air flow measurement, 923 axial velocity formula, 923 classification of, 919 corrosion, 931
- duct construction, 928 duct design, 928 duct resistance, 930 duct velocity, 928 .ducts for, 928 air velocities in, 928 construction, 928 design, 928 resistance, 930 dust filters, 704 efficiency of, 930 hoods, 920 air flow, 920 air velocity, 921