Document eyGxROOxJp1eY7yZ2B0Brzog

other locations GENERAL OFFICES C. T. Buclclay - UGK *V M. S. Baez H. M. Calloway - Nltro P. B. Hodges C. C. Hoffman'^- Delaware RR.. J. 1. Soiarl - JJTJ \\D. B. Hoaoar ^W. A. Kuhn E. S. Tucker - SoV^nd SC. R. J. Scratmeyer ANNISTON J. M. Carpantar C. K. Eaatmen L. L. fsulknar R. A. Hay dal V. R. Haupt L. C. Lehman J. C.. Landvehr A. G. McCarty C. W. Millar W.S. Pp*g*crrji B.O. Sever*on W.P. Taffe* H.L. Williams PROGRESS REPORT TECHNICAL SERVICES DEPARTMENT ANNISTON. ALABAMA PLANT JOB MO. 370:740 REPORT HO. 2 DATE 7/23/69 TITLE: OBJECTIVE: Aroclor and HC1 Department WaaCa Audita To identify tha aourcea of waata in tha Aroclor and KC1 Departments and Co quantify chase loaaas. PERSONNEL: E. G. Wright (W. r. Taffea) REPORTED BT: E. G. Wright SUMMARY: The major sources of organic (primarily Aroclors but with saaller amounts of Biphenyl, Santowax and RB-AO) and acid waata in the Aroclor and KC1 department* have bean identified and quantified. laaUy ef arganle material fraaa Chase farftSCs U tqjjrM&mflj *7Tha' new warehouse drumming and flaking area accounts for almost lialf of tha organic losses with an avaraga daily loss of 11//day. Tha remainder of Chase organic loaaaa com*from tha Aroclor still room sawar (2#/da Y> the chlorlnator sawar (3#/day) and tha HC1 department (6#/day). Tha acid losses from these departments came from two sources. Tha chlorlnator sawar and the BC1 department sawar. Tha chlorlnator fewer showed an avaraga loss of l,lQ0#ttCl/day and tha HC1 department losses were an avar aga of 15,500#/day. To provide facta on the effects of P.C.I. in plant affluaot water. Snow's Creek and Choceoloceo Creak ware investigated, Snow's Creak wee checked visually for two phase aysteme (l.a. Aroclor and water). Nona was noted mors Chan one block from tha plant boundaries. Six samp Isa of mud and watar war* collected downstream from tha plsnt (sea attached map for locations of sampling points). Thaaa samples era now being analyzed by organic research. Tha results of these samples will ba coomualcatad aa soon aa Chay are received. OSH 014284 WATER_PCB-SD0000017086 Anniaton Plant Prograaa Report f370:740 (2) Company Confidential Page 2 FUTURE WORK 1. Concinua Co monitor organic loaaaa periodically on Cha CoCal plane OUC flow. 2. A decision will be nade on continuing Co aanpla on Choccolocco and Snow'a Creek aa icon aa the rraulta from the flraC let of aeaplea are received. 3. Collect ona aaC of flah aeaplea fro<a Choccolocco Creak and have thaaa analyzed for P.C.3. lavala. 4. Continue to look for a batter aechod Co collect laaplae froa two pheea (l.a. Aroclor and Water) ayataaa. 5. Conduct a correlation atudy between the organic reaearch aethod for P.C.3. and the Anniaton method for tocal orgaolca. Technical Service* Departaent DSW 014285 WATER PCB-SD0000017087 Anntiton Plant Prograa* taport $}70:7k0 (2) C<par.y Confidential P*g j DETAILS l. Sampling and Analval* .g All (amp 1 aa taken during Chla audit war* 24 hour composite sample* with the exception of Ch* "grab'' sample* takan from Snow'* and Choccoloceo Creeks. Two very daflnita two phaaa syscen* war* noted during thla audit. The** war* locatad In the warahoua* *<w*r and In Snow'* Craak about on# block below th* plant outfall. Sampling thla two phaaa ayateo baa proven to be vary difficult. W* triad two aachod*. The flrat aachod waa ch* alow parlacaltle (Randolph type) pump. U* chan triad a high apaad parlataltlc pump. Both of thaaa war* unaatlafactory. We are pr***ntly crying Co crap tha Aroclor phaaa l.n a aap located at tha corner of the warahoua*. Thla aunp la being aeaaured everyday and ahould provide a much batter caClsat* of th* volume of Ch* aecond phaaa Chan w* now have. The (ample* which wer* collected In Ch* plant war* analyzed for total organic* by a method which wa* developed by the Anniaton plant labora tory. Th* alx aata of aaaplf which war* collected In Snov'i and Choccolocco Craak* will ba analyrad (pacifically for P.C.B. by Organic Research. Thar* ware two reaaona for doing the** analyaa* diffareotly. Tha flrat reaaon was that tha laboratory at Anniaton did not have ch* proper facilitlea auch aa a "clean room" and also Chat they did not hav* ch* correct type of election capture detector which waa specific for P.C.B. To pur chase thla daCactor and provide "clean room" (Aroclor free) working apace would have cast approximately $16,000. The second reaaon waa Che time element ln^lved. The P.C.B. method In tha P.P.B. rang* required approxi mately 2*3 hour* par aaapl*. It we* fait that running total organic* on tha in-plant (ample* would ba sufficient for determining exactly whara tha loss** war* originating. 2. Plow Measurement* Th* flow from th* KC1 department was measured by tha Lithium chloride dlludon method. Thla flow waa verified by actual physical maaur*mnt. Th* flow* from th* Aroclor still room and the warahoua# wer* determined by phyelcal measurement. Th*** flow* wra measured tvlce during Ch* timm which the waste audit waa being conducted. HC1 Department Audit Tha HC1 department receives anhydrous HCl from Ch* ehlorlnators in th* Aroclor department. Thla gaa passes through a falling film type absorber where it is absorbed in water Co fora Muriatic Acid. Th* BC1 gaa stream during the paat ha* contained entrained organic* which have caused problems in th# production of Water Whit#,organic free Muriatic Acid. During 1968 approximately one-third of the production waa aawerad in an attempt to solve Chia organic* problem. Thla amounted to approximately 3O H //day of MCI. In mid-1969 a catch tank and a sembrana type coaleacer wart installed to trap out and remove the** organics. The** two units are operating satis factorily and tha plant is now producing Water White Muriatic Acid. Tha OS* 01^286 WATER PCB-SD0000017088 Annitton Plant Progreaa Report #370:740 (2) Company Confidential Page 4 HCI Department Audit (Conc'd) organic material ie compoeed of 31phanyl, SanCowax end tha lower chlori nated 31phanyla. This material li preaantly being druesaed out and aant Co the toxic dump. Sample Daca Thaaa aaoplaa were collected far a period of 26 day*. They were analyrad for pH, Z HC1 and organic*. LlaCad below are the daily high and low and an average value for the 26 day period. A complete ll*c of all of the daca 1* on the attached daca ehaeta. The sampling point 1* noted on the attached procaaa aeuer map. Daily High HC1 2/dav 31,200 / Orgaincs /dav 2* f ally Low 1,200 / 1 / Average 15,500 / 6.0 / Average Plow 100 G.P.M. Warehouae Audit Thi* aawer collect* the waatas from the Aroclor druimaing and flaking area in the new warehouae. It waa found to be the largeat aingular contributor of organica to the acwer with an average daily loaa of approximately 11.0 //day of dlaaolved organic*. The 2nd (organic) phaaa of this aawer la praaantly being trapped in a auap located at the north-eatc corner of the warehouae. During a one week period we collected approximately 2.5 gallona of organica or 27/ for the 7 day period. Thia average 3.8 //day plua the 11 //day of dlaaolved maCarlal bring* Che total from thi* aourct to 14.8 //day. We will continue to sonltor Chi* tuasp to gather long Cera data. These organics c-.ae from two major sourcai. These are Che wet scrubber which we* instilled to scrub the vents from Che Slphenyl and Aroclor flakara. The organic material and watar la drained from the acrubber once per day. It la drained by drop ping the material into a drum and allowing the-aguaoua layer to overflow to the ewer. The ocher major sourcea are leak* and spills which art washed directly to the sewer when Che floor ta steam cleaned in tha warehouae. . Sample Daca Thaae aaaplee were collected for a period of 28 days. Thsy wars analyzed for pH, Z HC1, and organics. Whan it was found that Cha saaplaa ware neutral, pH and Z HC1 waa discontinued. Listed below *r* the daily high and low value* and an avarage dally value for Che sampling period. A complete list of Che daca ia on tha attached daca ahaecs. The aampla point la noced on the attached procaaa aawer nap. OS* 01*287 WATER PCB-SDOOOOb 17089 Anniston Plant Progress Report *J70:740 (2) Sample Pic* (Cont'd) High Low Organic! ^/dv 65# 2.2# Company Confidential Page 5 Organic 2nd Phase at/dav Average II-0# 3.8# Average Flow * 90 C.P.M. Chlorlnator Siwir Thta lever cacchei tha cooling wacer frees Che chlorlnator and alao the water from the drowning Jet* on the vent* of the crude Aroclor blowing tanka. The major aource of organic! in Chla lever are pump leak* from the circulating pump* on tha chlorlnator*. Tha primary aource* of HC1 are the drowning Jati on the blowing tank*. Sample D*ta Theae tataple* were collected for only IJ day* bacauaa repair* w*r* being made on thi* aewer when the audita ware begun In the other parta of the Aroclor department. They ware analyzed for pH, I HC1 and organic*. Dally highs and Iowa and a daily average are Hated below. A complete liat of all data la ahown on the attached data thaet. The aamp ling point la notad on Che attached proceaa sewer aiap. Organic* #/dav HC1 itdav . High 32.8 # 3,000 # Low 3-3 # Average Daily 8f Average Plow 250 C.P.M. 3001 1,100 # Aroclor Still Room Sewer .! This sewer receive* all of the water u*ad on the Jets on the Aroclor ttllli. Thee* aampla* wer* also analyzed for pH, X HC1 and organic*. Tha pH and HC1 were discontinued when there was no HC1 detected In a number of aemplaa. 5amp la Data . The** aampla* ware collected for a period of 14 days. The average dally organic! loea from thla aewer wee only 2 #/day. Li*ted below are tha dally high* and Iowa aa well as the average dally loaa for the sampling period. A complete list of the data 1* located on the attached data ahaec. Tha sampling point la noted on the attached process sewer map. DSU 014283 WATER PCB-SD0000017090 Anni*Con Plane Progress Reportyj70:7&0 (2) Simple Pats (Cont'd) Organic 4! dav Company Confidential Page 6 High 8.9 # Low 1.6 Average Dsilv 2# Avenge Flow = 65 G.P.h. Choccolocco snd Snew' Creek Due Co Che recenC development* concerning P.C.B. in water and lei effect* upon wildlife, we decided Co begin *mpling Che scream* which receive our wesce water from che Aroclor Manufacturing Process. We begsa sampling by fine checking Snow'* Creek for definite globule* of Aroclor lying in the bottom of che creek.- We were only able Co detect chi* a distance of abouc l block from Che plane boundaries. Ocher poinCa further downstream were checked but no Aroclor layer wa* found. Sample* were collected at six points downstream from the Anniston plant. One sample was caught upstream from che confluence of^ow1* *nd Choccolocco Creeks. Thi* sample l* to be used ee t blank. Soch mud and vsear sample* wars caught at each of these locatlona. The exact locstione where Cheae aaaplaa were collected srs shown on the attached map of Che Choccolocco Creak watershed. The decs from these samples will be published aa aoon as iC la racmlvad. During September of 1964 two secs of samples (mud and watar) were collected from Snow1* Creek. Theee templet were analysed for P.C.B. by organic reaaarch. Listed below ar* th* rasults froa chase samples. Sample Location Sediment Water Plant Outfall 0.20 + 0.02X 58+2 P.P.B. 1 Block Below Plant Outfall 1.64 0.0&X Sample Brokan Calculation of Cha above data into #/4ay yield* a value of approximately 1 #/day of P.C.B. which la actually lost Co Snow's Creak. The probablereaeon for the difference between 27#/day which wa loae In tha'plant end Che If/day which shows up In Snow's Craek la Chat Che analytical method uacd to maaaure loaaea in the plane measures cocal organics losses. Th* loss** In Snow's Craek were measured using the Organic Raaaarch method which La (pacific for P.C.B. OSH 014289 WATER PCB-SD0000017091 ?pfns pH ZHC1 ganica 6/3 6.5 NDA 2.0 6/4 6.7 NDA 11.3 6/5 6.7 NDA 2.5 6/6 7.2 NDA 5.5 6/7 6.3 NDA '6.0 6/8 6.2 NDA NDA 6/9 6.3 NDA NDA 6/10 6.2 NDA NDA 6/11 6.3 NDA NDA 6/12 7.1 NDA NDA 6/13 7.1 NDA NDA . 6/14 7.1 NDA m\ 6/15 7.4 NDA NDA 6/16 7.5 NDA 7.5 WASTE AUDIT DATA SHEET rJOcgan i.c& /day 1.6 8.9 2.0 4.2 4.7 ** - - -' 5.8 Prod FI ow Rate 65 cn. Commcn cs - - - -' -' - - - - - - - - AVER/ CE Hi AY - 2 DSW 014290 WATER JPCB-SDOOOO017092 WASTE AUDIT DATA SHEET Deroartaenc Dace 1 P" -- A*1rHoCc1loP^rPaMDn'ie0cp5-at.rtaenc 6/4 3.2 .10 2.4 . 0HC1 /day Sanpling Point Chlorinacor $<y.;c ll#O_r__g__a____> CM /day Plow ' Prod Race ' _____ Comtcenc s 3,00() 7.2 250 G f 6/5 6.2 NOA NDA 6/6 10.3 NDA 1.1 -- i 3,3 - - 6/7 3.6 .09 1.3 2,800 5.3 - 6/8 4.1 .10 10.9 3,000 32.8 - ' 6/9 2.7 .01 8.0 300 24.0 - 6/10 3.7 NDA 2.0 6/11 5.7 NDA 8.5 - 6.0 - 25.5 - 6/12 3.5 .04 NDA 6/13 3.5 .04 NDA 1, 200 1,200 - | 6/U 3.5 .04 NDA 1,200 - - 6/15 4.1 HOA NDA 6/16 2.7 .05 NDA -- - t 1,500 - - AVER/:12 #/E - 1,100 8.0 . OSH 014291 . _L WATER PCB-SD0000017093 WASTE AUDIT DATA SHEET |pH Date 5/20 .9 "Tim;r2 HCJ ganlc 1.1 NDA 5/21 .7 1.7 .5 5/22 .9 1.2 NDA 5/23 .3 1.4 .5 5/26 .8 2.6 2' 5/25 .8 2.6 2 5/26 2.0 .1 4.0 5/27 2.4 .1 5.9 5/23 1.5 .3 2.5 5/29 1.0 .6 12 5/30 .1.2 .6 7-3. 6/2 .4 . 2.3 .1 6/3 .8 1.9 3.3 6/4 1.1 .7 20 6/5 .8 1.3 4*6 6/6 .8 2.2 8.6 6/7 .7 2.1 5.7 6/8 .9 1.3 5.7 1|/Diy ?HCl 7dav - 13,20 : | Prod 1 Flow Race LOO Cl Coeneent: .6 20, 40< - - 14, 40C - .6 16, 80C - 2.5 31,20C - 2.5 31,200 - 4.^ 1, 20C - 7.1 1, 20C - 3_.0 3, 60C - 14.4 7, 2QC - 8.8 7, 20C - .10 27, 60C 4.0 22,80C - * 24.0 8,40C - 5.5 L5,60C - 10.3 26, 40C - 6.9 25, 20C 6.9 5,600 - '| OSW 014292 J_____________________ - WATER PCB-SD0000017094 Department .PPm Vt 7. HC1 ganic! 6/9 .3 1.4 NDA \J\ o 6/10 1.1 .5 6/Ll .3 1.2 6.0 6/12 .7 1.2 4.5 6/13 .7 1.2 4.5 6/14 .7 6/15 .8 1.2 4.5 .8 5.0 6/16 .2 2.1 1.5 VASTS AUDIT DATA SUES' vOrgan lcs /Day 0HC1 /dav - 16,8QC 6.0 6, 00C Prod . Flow Race L00GPM Comreencs - 7.2 14,400 - 5.4 14,400 5.4 14,400 5.4 14,400 6.0 9,600 1.8 15, 200 -' - AVER/ TE #/E VY - 6.0 .5,000 OS U 0 L4293 -------------- 1 J_______L______________________- WATER_PCB-SDOOOO017095 VAST! AUDIT DATA SHEET Deptenc_Aroclor De^rtmenc Dace pil 'rpjTSrp ZHC1 feaniesj 5/20 32 ^Organ^ca /day 35.0 Sampling PoinC Warehouse Seve: Prod Plow Rate Conw.cn C s 90 CPM 5/21 11 12.0 5/22 NDA 5/23 5/24 5/23 5/26 5/27 5/28 5/29 5/30 5/31 6/1 6/2 7.2 NDA II DA 25 7.5 3.0 2.7 4.0 4.0 4.0 2..0 7.S 27.0 8.1 a.7 29.2 4.3 4.3 4.3 2.2 6/3 5.8 NDA NDA 6/4 6.4 NDA 15 6/5 6.7 NDA 10 6/6 7.2 NDA 13.3 16.2 11.0 14.4 0SW 014294 WATER_PCB-SD0000017096 Depart acnc ^ PPM Or pH XHC1 ganici 6/7 6.4 NDA 32.6 6/3 6.2 NDA 12.0 6/9 6/10 - 5.0 - a.o 6/11 6.2 NDA 5.0 6/12 5.6 NDA KDA 6/13 - - NDA 6/14 - NDA 6/15 4.5 NDA 60 6/16 6.1 NDA 2.5 WASTZ A LTD IT DATA SHEET Morgan tea /day 35.2 13.0 5.4 8.7 5.4 - - 65.0 2.7 Prod. Flov Race 90- CPI Cototncncs - - -' - - - - r AVER/ CZ #/I AY - L1.4 OSH 014295 A Ml , .1 ---------- WATER_PCB-SDOOOO017097