Document evqp2LLMey3VOmbb8Oy4xXQbE

CHEVROLET MOTOR DIVISION General Motors Corporation EXHIBIT BRK-225 Toledo Plant Toledo, Ohio Mail Address P.O.Box 90S Toledo. Ohio 43692 March 6, 1978 Mr. Robert Riley: Assistant Superintendent Industrial Commission of Ohio Division of Safety & Hygiene 2325 W. Fifth Avenue Columbus, OH 43216 Dear Mr. Riley: On February 9, 1978, Mr. Richard Maykowskl of your Industrial Hygiene staff visited our plant In reference to an alleged occupational disease claim. During Ms visit, Mr. Maykowskl obtained several air and coolant samples. He Informed us the results of his tests would be available, upon our request, within four to eight weeks from the date of Ms visit. I should like to take this opportunity to formally request those results. Very truly yours DFtmJn W. A. Phelps Plant Manager / STATE OF OHIO THE INDUSTRIAL COMMISSION OF OHIO DIVISION OF SAFETY AND HYGIENE 2323 WEST FIFTH AVENUE P.O. BOX 1743 COLUMBUS. OHIO 43216 te> ^ PMOf-e (614) 466-3385 Industrial Commission WILLIAM W. JOHNSTON Chairman RAYMOND A CONNOR Vico Chairman LEONARD T. LANCASTER Mem bar JAMES A RHODES Governor May 1, 1978 Division of Safety and Hyfiene PHILIP A. WORKMAN Superintendent BOB RILEY Asst. Superintendent Legal Section Industrial Commission of Ohio 246 N. High Street 1st Floor Columbus, Ohio 43215 O.D. 577495-22 William Henson Chevrolet Div. CMC Toledo, Ohio Attn: Jeff Nackley Gentlemen: On February 9, 1978, a visit was made to Chevrolet, Division of 6MC, 1455 West Alexis Road, Toledo, Ohio, to evaluate conditions under which the claimant worked. According to company records, the claimant was hired on September 29, 1969, as a journeyman millwright. He remained in that job throughout his employ ment until he retired on March 27, 1975. As a millwright, the claimant had no fixed work assignments, but moved throughout the plant to whatever area required his services. In this plant, millwrights are responsible for cleaning and repairing machinery, maintaining material, handling equipment, such as conveyors, etc., any construction needed, moving machinery when necessary, and doing rigging, among other things. Since the claim concerns an incident which occurred while the claimant was working on a "Lamb" machine, this investigation was concentrated in that area. The area contains several identical machines which are used to machine aluminum parts. Some changes have been made in the area since the claimant's experience there. Partitions have been erected to control noise exposures in adjacent areas. Also, no one now works in the area regularly, so obtaining personal samples was prevented. Air samples were collected at three locations in the "Lamb Area" using tared polyvinyl chloride filters and personal sampling pumps. These samples were then submitted to the laboratory where they were analyzed for oil mist. The results of these analyses are listed in the accompanying table. O.D. 577495-22 page 2 There was difficulty In analyzing these samples by the normal method because the oil was not soluble In chloroform. However, due to the nature of the operation, the only material likely to be trapped on the filter was oil. Therefore, the gravimetric analysis for total particulate has been reported as oil mist. For a safety factor. If each result were reduced by approximately 10 to 202, the difference between oil mist and .total particulate would be In agreement with other sample results of this type. In conclusion. It can be said that anyone working In the Lamb area while the machines are operating would be exposed to considerable levels of oil mist. Richard M. Maykowskf Industrial Hygienist RMM/nlg Chevrolet - Dlv. GMC DATE(S) SAMPLED: February 9, 1978 INDIVIDUAL OR SITE TESTED CONTAMINANT LAMB AREA TEST RESULTS TABLE # I CONCENTRATION DETERMINED (mg/M13)2* ACGIH** 8-hour TL West Platform #3 Machine East Platform #3 Machine East Platform Oil mist Oil Mist Oil Mist 5.35 4.56 5.51 5.0 5.0 5.0 * - RMM/nlq (1) * MILLIGRAMS PER CUBIC METER OF AIR (mg/M3) (2) ** AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS (3) *** THRESHOLD LIMIT. VALUE vr** T s - "v; .- > ' , V~' ')Kr'J-K o , * : /, -r. -> .' -v v-` ' .;' ,v v ry?t# &as: 19/1963 y. Mr. Harry/Sprinski > Chairsan, Chovrolatr tfn&t/Wdal lb 851 Islington Mfcjief--^ Tolado 10, Ohio " . T .J" >.. > I *4*4* Dost Mr. Sprinskit; ' ' ''''y '' r' Thank, yon for your'^eitei* of Jnne'Utiu.^ I hadjuat started .. on two waka ae^vs'dot/at tbs tins you wrotp your lettar, .hence,, this dj^l7 ln ^ />/' : I rat enclosing the 'literature listed belcw. The ohaBloal that, yon report is 1,1,1-triohlorpethana*. The,,.only syaptaa which yon ro* port which la lirtadia tbo\ incideed Quids is that of..burhing eyas.. *+4r'l>`-` \<*t *' ` `, * ?.** * '*; * *, * % " . wj ' * This .chesioal is ope of the. safer chlorinated hydrocarbons, having; -^ ` ` ` On the; approximately__ .... ^ American Conference of Oovarmeatii; liSlustrial' Bygiunista, local-, exhanat ventilation ahoold .be pror^dadwhan.thia material ia used in open oootaicora. If this ;Uti(iarWt'-*ia;uaed with general exhaust ventilation, apprcodjaately.2li,000 cubit/fSet of exhauat ventilation should be provided for .every.:pjafeytajl^ .- ' -*;;*?,* C C\ ` There, ere other seXtepts that ar#leee Volatile than this material, but they say be iwtre, toxin TSe enclosed infarsatlon, I m sure, will b oTvaiue;!> *T -* V- If you would, care; for a.esnbar. of,our'staff to viait your plant, I would suggest, that you showthis lnformatioa to the plant / safety director and have hi*inrite us* That Say,'I s* sure he would be ere receptive to any reocMaendatldns ^fe sight sake. V. ; *: . % ' .\ j' . Yery truly yours, EHsMH enc: t. 2. Hygienic Quids Series '' 1,1,1-TrichloroethipO Selection of Sclrvifa NnA the Control of Substitutes for 'H^;r QgVii.tSuffSan Industrlal ilyglene Bngineer . y: x'v- ._*v C'V 'i I I \ AEROSPACE AGRICULTURAL IMPLEMENT WORKERS -/AMERICA (RAW) LOCAL No. 14, U.A.W. 11 (IIINOtON I T I I T TOLKDO 10, OHIO Jim* 4, 1963 Tfcon# 244-74*7 The Industrial Commission of Ohio Division of Safety k Hygiane 700 V. Third Street Columbus 12, Ohio Dear Sin To whom this say conoerot The Chevrolet Passenger Transmission Plant in Toledo, Ohio, is in dispute over the use of a liquid clearer of metal Chlorothene which is used in open oontainsrs at this location* The employees coaplain of burning eyes, headaches, upset stomachs and dry skin, management states there is enough ventilation as is in the plant* The union does not agree. Ve are asking that management stop using this liquid. The drums are marked CADTICS 1 - Use with adequate ventilation 2 - Avoid prolonged or repeated contact with skin 3 - Avoid prolonged or repeated breathing of vapor 4 - Do not take internally* Please eend me any information you oan on the use of this Chlorthene. I thank you Harry Sprinski Chairaad, Chevrolet Unit, Local 14 831 Islington St. Toledo 10, Cbio v*-' Oil Base Soluble SOURCES: D.A. Stuart CODE NUMBER 7000 213 DASCOOL 130 CT SPECIFICATIONS: Specific*Gravity @ 60F API Lbs/Gal 0 Viscosity @100 F. Flash Point Fire Point Sulfur Chlorine Water Sediment Saponifiable Matter Rust Test .9480 17.7 7.90 201 S.U.S. 285qF. 315 F. .631 2.221 3.8Z Trace 20.20X 4 Days - No Rust DISTRIBUTIONS: All distribution is mads from Main Oil Crib and by Maintenance to central Kysteta. USED: Used as coolant on the Lamb Transfer, Automatic Screw Machines. REMARKS: All uses subject to Plant trial and lab approval. t t * Code Number; PROPRIETARY COMPOUNDS AND CHEMICALS 7000213 Source and Trade Name; D. A. Stuart Dascool 130CT General Description: A semi-synthetic coolant for aluminum machining ooerationo. Contains HO* mineral oil, 25* fatty oils, and 35* emulsifiers. Viscosity 5 100P 200 Sus. Bulk delivery to tank farm Formulation for Use: Piped to the aluminum machining operations and diluted *?ith water to a concentration of T-9S Precautions May be a skin irritant to some individuals. If brought into the eyes, flush eyes with water, then go to Medical Dept. Plash ooint: 300? Min. Fire point: 350 P Min. Specific Uses By: Plant - Engineering: Production;* Aluminum Machining operations - This material has been approved for use aa indicated. Afi-