Document evqoZyvd0ga749KKzverZ3w1E

cPif* PtrUie Fluid twpmfan surf Whet Checfcpolnte Mean .......................... . 1? A. Visual impaction.................................. .13 B. Dielectric Breakdown Voltage .......... .13 Impaction ChoeltWd................................. Contamination In Trwfornnri............... 13 14 Table VI - Effect of Common Insulation Materials on Power Factor and Dielectric Strength .................................. 14 Table VII -- Effect of Common insulation Materials on Volume Resistivity of Askarel................ .. ASTM Method for Inseetlgeting the Compatibility of Transform* Imutation and Construction Mmridi m AdasH ftofawnp Askarsi far NaUo A. Filtaring Through Dry Blotter Paper to Remove Moisture and E xtreneous Particles............................ Table 2HJ- ^Wete ftemo> L* F 4tet>ng Ataii 15 Tni*Hh a Paper Prats ..................... 16 E *?<-} o-f s. 8 Dispute* .* Solid Wastes ............................ 16 fa r ^ Sol'd Insulation Requiring Drymg tor AmrJ 0. Earth Treatment for Maximum .16 SECTION A TRANSFORMER ASKARELS.......................................... 1 --"'A. Improvement of Power Factor and ^`'v.yoiume Resiltivitv ......................................16 I I I. Introduction............................................................ 1 H. History of Trade Name Types................................1 Table IX ^Volume Resistivity.........................17 XXI. Cleaning Aroad Traneformars........................... 17 I Table I - The Composition of XXII. Sampling Adtarel................................................ 17 T remtormer Aikerelt ........................................... 2 III. Interehengeebility ................................................ 2 serTinsi ft IV. Table II - Official Transformer Adtarel ASKAREL FILLED SWITCHES Shipping Specifications.........................................3 AND TERMINAL CHAMBERS ......................................19 V. Ordering Instructions ........................................... 2 VI. SttbMty...................................................................2 VII. Precautions Whan Handlina Drums. Tankcars I. Introduction........................................................ 19 II. Sources of Contamination .................................19 HI. Seeling Switches end Terminal Chambers .20 and Whan Opening Traneformars.........................4 IV. Adtarel Used Under Mild Arcing Conditions .20 A. Kaep Dry During Handling ........................... 4 V. Maintenance for Adtarel F Wad Bwhahee . 20 Table Ml - Handling and VI. Adtarel Under Exceed* Temperature Pumping Temperatures................................... 4 or Fault Conditions ...........................................21 B. Use Ordinary Personal Precautions ..............4 C Precautions on Opening an Askarel Transformer.........................................5 VIM. .Avoid Environmental Pollution..........................5 f. TL Libeling Askarel Transformers...................... 6 C*. Disposal o< Liquid and Solid Wastes . . .6 3 v Conditioning of New or Recycled Askers! .6 ^. *51, Teardown of Transformert - for Repair or Scrap .........................................7 Transformer Disposal...................................... 7 IX. Expacted Sarviee Life........................................... 7 X. General Characteristics of Transformer Adtarel Fluid........................................................... 7 XI. Sampling TransformerAdtarel Fluid .................8 XII Evaluation of Adtarel Received in New Equipment................................................ 8 XIII. Dielectric Breakdown Voltage - MoNturs Relationship........................................... 9 Table IV - Relation of Dielectric Breakdown Voltage to Amount of Dissolved Water in Askarel end Mineral Oil.........................................9 Table V - Approximate Solubility of Water in Transformer Askarel and Mineral Oil ... 10 XIV. Turbidity ...................................................... 10 XV. Cheek Points for Maintaining Adtarel Insulation .............................................. 10 A. General Considerations................................. 10 B. Modern Sealing Procedures ......................... 11 C. The Older Sealing Arrangements..................12 SECTION C ANALYTICAL SERVICE* ON . C^U' TRANSFORMER ASKAREL AVAILABLE FROM MONSANTO ... - 77 Types of Analyses Available: ...........................................22 ij Routine Maintenance Check......................................22 c im(>r*-w Analysis . .... Analyst Af1*i Earth Refinement ... 22 22 Appendix A - Askarel Stability and Composition of Arc Formed Gas.......................... 23 Appendix 9 - Solubility of Gas in Transformer Askarels .......................................... 73 Appendix C - Effect of Temperature on ' Dielectric Breakdown Voltage of Askarel Appendix D - Comparison of the Approximate 23 Viscosity in Ssybolt Universal Seconds of Transfoi mer Askarels and Mineral Oil........................... 24 Appendix E - The Density of (nerteen 54201 KA 7336 9 end Transformer Pyrenol A13838 2 ................................................. 74 Appendix F - Thermal Conductivity Values of Transformer Pyrarol A1383B 2....................... 24 Appendix G - Heat Capacity.................................. Appendix H - Coefficient of Expansion .... 24 74 Appendix I - Fire Resistance.................................. 24 Appendix J -- Seels. Properties end Procurement .......................................... Appendix K -- Caution Label.......................... 75 HOIKS 0?5Si Sdn(S)m A Tramstotrimeir AsEiaireS I. Introduction The term "askarel'' as defined by IEEE, ASTM end the National Electrical Code generally describe! a broad dam of non-fierr.meble lynthetic ehlsrinittd hydroetrbon Intullting liquid! wMtly uud In transformers, reactors and accessory equipment operated at power frequencies. Askareis of various compositional types are in use. (For the general properties and types see ASTM D-22B3.) Under arcing conditions the gases produced, while consisting of predominantly non-combustible hydrogen chloride, can contain varying amounts of combustible gases depending upon the askare! type. This manual describes the operating characteristics of transformer askarel liquid Insulation and how it differs from mineral oil. Appropriate handling and disposal procedures for both scrap askarel liquid and impregnated solid materials ere given in accordance with the guidelines recommended by the American National Standards Institute. The information is based on facts gathered by Monsanto over 40 years es a producer of askarel, plus knowledge gained from the experience of ! transformer manufacturers end users. This guide outlines the very Other brand names used by electrical manufacturers to designate transformer askarels used in their products include: Simple maintenance required for askarel fluid in "modern'* transformers and offers suggestions for sealing and maintaining askarel in old units. By following this guide, wa believe users will obtain maximum service AebettoT* Chiortxtoi*** Jnartaen from askarel insulation with a reasonable minimum of maintenance. If questions arise relating to the designing end building of transformers, these should be referred to regular transformer suppliers. No-Flamol Saf-T-Kuhi Monsanto gratefully acknowledges the assistance, guidance and the contributions of oertain data by the following: Edward L. Raab - General Electric Dr. T. K. Sloat - Westinghouse Electric KSS le<.f>ic. Co r por A brnnJ Mine, Ii. i' ll. Hiitory of Trad* Nm Typa l "Askarel'' is the generic name for the non-combustible liquid insulation end coolant first used by General Electric Company in 1932 for their Pyranol* brand name fire-resistant transformers. y _ Otrathnaefrt-rbmraanrdaeekhatwu yk^aacfiii~Tthyeirlproad>uiiicetrs-inelmadfai;.u--v ip -* 'Tradwmrk ol OttoU Clamlal Company, Ine. "Tredemir- of Allh-Cheimer* I --3------ lie Flung! a_____liaC'T^uhl HONS 075253 Whetever the trademarked brand, the askarel contains chlorinated biphenyl -- one of the best liquid insulations developed by science. This inert materiel it chemically stable, fire-resistant, heat stable, non-corrosive, and has high dielactric strength under the operating conditions encountered in transformers. In addition to manufacturing Arodor* (chlorinated biphenyl!. Monsanto also mixtt this dialactric fluid with chiorobanzanat to product the presently used Inerteen and Pyranol Wands dascribad in TaWa I. / Co>porJJ) Trademark of General Electric Company el Ctilxfji Clmnleel Cempenw, I 'ftafittarod trademark of Monsanto Company / Table I The Composition of Transformer AAarali MwhodASTM 0^283 ., lyplD[ Tvc. E ~ TywHj* & Trad* Nimn Inerteen 54201KA 70*30 inerteen 64201CM Inartaan 10042 Pyraool A13638*3 Ingredients (% by wt.| Arodor* 1254, pentachlorobiphenyl Arodor* 1242, trichlorobiphenyl tr (chlorobenzene tritetrechlorobenzene phenoxyprapeneoxidi sc*vonpor."dlepoxme:i 70 i/ 40^*60 100 y >MO *K - I 0.115 to 0.136 A8TM Method D-22B3, titled "Zhktrinatad Ai5L k Hydrocarbon* (Aakaratt) for Tnmforman", also Utti the composition of all Iramformar aikaraii mad at various tknee sine* 1032. Monsanto manufactures similar transformer asfcarai fluids in England where tha trade name Pyroctor is used. III. Interchangeability In general transformer askarel* are intarchangeabia. However, it is supplied diet the transformer manufacturer b* consulted prior to mixing in significant proportions or total substitution. IV. Official Transformer Atkaral Shipping Specifications The official shipping specifications for tha three modern transformer askarel fluids are shown in Tabi* II. V. Ordering Instructions Monsanto's currant policy is to sail askarel transformer fluids only to transformer manufacturers. Others interested in these fluids should contact the manufacturers of askarel transformers and not Monsanto. The transformer name piate indicates tha transformer maker and usually gives sufficient data to identify the specific askaral fluid used. VI. Stability Askaral liquid Insulation is highly pure, fire-resistant liquid made under dose chemical oontroi to meat, the exacting specifications as shown in Table II. It does not vary in composition like the commercial range of minsrd oils. Askaral Insulation must never be mixed with mineral oil. Over two percent of mineral oil by volume in askaral begins to lower its fire Askaral does not deteriorate whan exposed to air, heat, hot metal; it does not break down over long use to form conducting or corrosive chemicals; it does not oxidize or sludge. Askarel will remain perfectly stable year after year unless broken down by severe electrical discharge. In modern, transformers, the only real "enemy" of askarel is contamination by water. Keeping askarel water-free will insure long-time sendee. Askarel is heavier than water. If water gets into wkarei insulation, only HONS 075254 / Color, APHA Condition Water content, ppm (A$TM D153340) Acidity, mg KOH/9 (ASTM D974-66) Dielectric Strength, 2S*C, 0.1 in. gap (ASTM D877-49) Dielectric Constant, 100*0,60 H* (ASTM 0924-48) Volume Resistivity, 1(X7C, 500 volts DC 0.1 inch gap, 10 ohro-cm (ASTM D11691 Inorganic chlorides, ppm (ASTM D1821 and G.E. Method E4C41B) Refractive index, 25>aC (ASTM D1807) Viscosity at 37.8*C (ASTM D88-60) Saybolt Universal Seconds Pour Point X (ASTM D-97-67) Specific gravity 25/15.5X (ASTM 01810) Burn point (ASTM 092) Distillation range (ASTM D20-56) corrected for stem and barometric pressure Fixed chlorine Corrosion test Color, APHA Acidity, mg KOH^g Inorganic chlorides ppm Condition .Scavenger content TggieaiPragggigCoefficient or Thermal Expansion IASTM D1903).cm3/cm2/C Arc formed gases Title II Official Transformer Asfcarai (IwrS fltsrk Co. pyiwi1 Ai'aeSefiry . ASTMOOSSTypolfr* n S4201KA or Inersaon 70-31 ASTM D22S3 Typo O 150 max. Clear 30 max. 0.014 max. 36 KV, min. 4.2 to 4.5 100 0.10 max. 16153 to 1.6173 56 to 61 -30 or lower 1.518 to 1.628 None to boiling 1st drop 200*C min. 36% below 270*C 90% 379 to 384 ASTM Q22S3 Type E 60 max. Clear % max. 061 max. 36 KV, min. 4.7 to 46 100 0.06 max. 1.8240 to 1.8260 62 to 82 --17 or lower 1.38110 1.382 None to boiling 10% 325X min. 90% 360 max. 556% min. 43 0.5% After heating with aluminum for 6 hrt. at 200 to 220X, the aluminum must not be corroded on either visual or weight inspection and the adcarsl should meet the following speciftcaiiorw: 200 max. 200 max. 200 max 0.014 max. 0614 max. 0.01 max. 0.15 max. 26 max. 0.15 max. Clear Clear Clear 0.115 toO.136% 0.18to062% 0.18 to0.22% Otapoxida phanoxy propane oxide phenoxy propane oxide 0.0007 0.0007 060068 Asfcecete of various compositional types ere used. Under arcing conditions tha gnu produced while consisting predominefuly of norvcombusUbie hydrogen chloride, can indude varying amounts of gmt depending upon the asUrd type. Insulation systems incorporating mess erirareh and ceiluiosic or otfwr organic materials may 4ien arced, produce gaseous mixtixes which are moderately flammable At a precaution such saws should ba removed from tha eskarel by bubbling dry nitrogen throutfi ttte a*arei and flushiM the sat space with dry nitrogan before my work it performed on tha apparatus. AST 0ia3 p.-J.-j HONS 0 7 5 2 5 5 liny amount (approximately 12S ppm) dissolves - tha rest floats on top. Askaral it vary insoluble in water, only about 200 part* par billion of aikarel dissolve in water, at normal temperatures. VII. Precautions When Handling Drums, Tankcars, and When Opening Transformers TM The American Institute of Electrical and Electronic Engineers Guide No. 76, December, 1068 has been revised to give more detailed instructions and guidance "For Acceptance and Msinttnsne* of Tnmformtr Atksroi in Equipment". This guide is published by the Institute of Electrical & Electronics Engineers, Inc., 346 East 47th Street. New York. New York 10017. The following ere significant precautions: A. Keep Dry During Handling: in handling, storing, sampling and inspecting askaral -- end in operating askaral transformers - take every precaution to guard the askaral insulation from exposure to high humidity end moisture contamination. Keep 5, 30 or BS gallon drums of askaral dry; lay stored drums on thair sides with the bung at -the highest point from floor to keep water off the drum head (which can be sucked into the askaral by the drum "breathing"). This precaution is not necessary when drums are stored indoors, which is the preferred place for storage. To avoid leakage the drums used for askaral are of heavy construction. Sixteen gauge metal Is used, with special rim seel and bung construction. The drums should be drained as completely as possible and then flushed twice with karoeene typa solvent to remove ell of the eskerei. Accumulated liquids and washings should be collected and should be incinerated at high tamparaturas, e.g., about 2000*F, to dastroy the polychlorinated biphenyls (PCBs). See Section A, VIII. Tank cars used to transport askarels are in exclusive service and not used interchangeably for other products. All cars must be unloaded through tha top (dome fitting) either by pumping or with controlled proseure using dry air or dry nitrogen. If nitrogen has been used for unloading it is necessary to advise the shipper to that when the car returns tha nitrogen can be replaced with dry air before any one may enter the car. If tha car is to be unloaded by pumping it will be necessary to use a dryer on tha air intake line to remove moisture. All tank ears are fitted with steam coils, which ere available for unloading under extreme low temperature conditions. Convenient handling and pumping temperatures and the related approximate visoostty ranges are given In Table III. B. Use Ordinary Personal Precautions: Transformer askaral has been made, handled, and used for over 40 years. It can be handled safely with recommended precautions, if accidentally spilled on hands, no serious skin Irritation will occur. However, liquid askaral has solvent action (similar to paint Table III JProduct Pyrenol A13B3Bfcl Ineneen 64201KA Inerteen 64201CM Unloading, /Handling and Pumping Approximate Temperature *C Viscosity SUS (*o-.rr 100-40 20-65 100-40 36-76 100-40 /i HONS 075256 i/ thinner) on the feti end oils of the thin end prolonged contect may lead to drying and chapping of the akin. J"/ In caia of contact, wash the skin with soap and water; remove and dry dean saturated clothing. Clean up spills with rags, sawdust and absorbent clay. Eye contact may result in painful irritation but no permanent damage to tissues. If eskerel gets in the eyes, flush with large amounts of water. As with all eye first aid, refer to a physician. To relieve irritation, physicians have used an opthaimfc anesthetic solution as wall as opthalmic cortisone acetate solution, ""t* Infrequent exposure to askarel vapors will not causa ill effects. However, prolonged exposure to high vapor concentrations should be avoided. If hot askarel must be handled in a dosed or confined ` area, provide the area with mechanical exhaust ventilation - or waar an organic cartridge mpiretor approved by the U.S. Bureau of Minas. C. Precautions On Opening an Askarai Transformer: Askarels of various compositional types are used. Under arcing conditions the gases produced, while consisting of predominantly non-oombustibls hydrogen chloride, can yield varying amounts of . combustible gases depending upon the askarel type. Insulation systems incorporating these askartfs and ceiMoeic or other organic materials may, when arced, produce gaianui mixtures which arc moderately flammable. As a precaution, sudi gases should be removed from the askarel by bubbling dry nitrogen through the askarai and flushing the gas space with dry nitrogen before any work is performed on the apparatus. VIII. Avoid Environment*! Pollution Transformer askerals contain polychlorinated biphenyls (PCBs) which have been used in the United States and elsewhere over the pest 40 years for many industrial and consumer applications. During the peat several years evidence has accumulated to indicate that PCBs are widely dispersed throughout the environment and that they can have adverse ecological and toxicological affects. The United States Government's Interdepartmental Task Force on PCBs. Com-72-10419, in their March 20, 1972 report titled, *ToiycMo/inatad Biphanyit and tha Bnvimnmant", recommended restricting PCBs to use in capacitors end transformers. This report Is distributed by the National Technical Information Service. US. Department of Commerce, Springfield, Virginia 22151. A document titled, *Guidafinat for Handling and Dttpotai of Capacitor i and Tramformar Grad* Adtarah, Containing Pofychiorinatad Biphanyh", has been prepared and is available from the American National Standards Institute, Committee C107, 155 East 44th Street, New York, New York 10017. The scope, objectives end the composition of this committee are: ANSI CommitteeC107 HONS 0 7525 7 Scope: Procedures and guides for safe use, maintenance and disposal of askarel and aakarvl-soakad materials used m electrical equipment. Objectives: 1. Source of technical informetion and advice for Federal, State, local authorities and all others concerned. 2. Encourage development of suitable disposal facilities end ___ keep ell concerned informed. _____ ___ 3. Serve as the advisory group for United States participation in international organizations: CEE, IEC.CIGRE. 3" Composition: Organizations activt in or represented by this ANSI committee include: National Electrical Manufacturers Association, Electronic industries Association, institute of Electrical and Electronic Engineers, American Society for Testing and Materials; Electric Light end Power Association; Certified Ballast Manufacturers Association; Environmental Protactlon Agency; Office of Environmental Affairs; General Services Administration; National Bureau of Standards; Department of the Army; Rural Electrification Administration; Division of Environmental Research, TVA; American Public Power Association, Water Pollution Control Ftdiritlonj Food md Drug Adminlilritlon: National Fire Protection Association; Underwriters Laboratories; and several sections of the U.S. Department of Interior. The following are pertinent excerpts taken from the ANSI Guideline! for eskerel transformers: LABELING ASKAREL TRANSFORMERS "All new eskerel traansswfoerrmrr ers should be labeled: - t^p jyfjgn The Insulating L.iIqquuididJjpi' This Transformer Contains Polychlorinated Biphenyls (PCBs). Care Should Be Taken To Prevent Entry Into The Environment. In Case Of Malfunction Or Leaks, Consult The Instruction Manual Or The Manu facturer. The transformer manufacturer should make similar warning labels available for use on previously installed transformers.'* DISPOSAL OF LIQUID AND SOLID WASTES '`Disposal of askarel fluid end askarel-eoaked materials must be accomplished by means in which there is no significant release of askarel to the environment. At present, disposal is eeoomplished by carefully controlled high temperature incineration of liquids and soaked software; and by controlled dry land-fill burial of apparatus and other hardware from which askarel has been previously drained and washed. . "Present knowledge indicates that proper incineration should involve a suitable balance between dwell time end temperature In the Incinerator plus oxygen availability end finally suitable scrubbers to remove HC1 formed; e.g,, (1) two second dwell time at approximately 2000*F end 3% exoces oxygen in stack gas; (2) 1-1H saoond dwell time at 2700*F and 2% axcess oxygen in stack gas." The ANSI Guide lists the locations of facilities that conform with the above requirements. Monsanto has such an incinerator at the W. G. Krummrich Plant, Department A-24B, Sauget. Illinois 62201, where arrangements can bt made for scrap askarel liquid disposal for a modest fee, currently 3 cents per pound. For dispose! of solid scrap a controlled dry land-fill can be used where permitted by Federal, State and local regulations. CONDITIONING OF NEW OR RECYCLED ASKAREL1 Conditioning of new askarel or recycled adtarei requires Fuller's earth treatment. The spent FuHer's earth in evtridges or bags when replaced should be allowed to thoroughly drain over drip pens to remove as much liquid askarel as possible. The cartridge units of steel mesh construction should be plaoed in the "Steel Contaminated with Askarel" container for disposition. Cloth begs filled with Fuller's earth should bt placed in the "Scrap Burnable Askarel Waste" container for disposition. MGNS 075258 egrimHiae ids fee ever all lallusa reta ta i dtan ft IH far // *GNS 075259 TEARDOWN OF TRANSFORMERS FOR REPAIR OR SCRAP e. Drain all askarel from the unit either into a holding tank for reuse or into tha drum labeled "Scrap Askarel" for disposition, then allow sufficient time for all tha askarel to drain from tha core and coils. b. Remove the core and coil assembly from the transformer and place it on tha floor. Sufficient absorbent material should be placed on the floor to absorb any askarel fluid that still drips from the transformer. c. Piece ell materials In the eppropriate salvage containers during the dismantling for later disposition. d. Ail used materials, including regs, sawdust, tape, etc,, regardless of quantity, should be put into the appropriate containers (or disposition. TRANSFORMER DISPOSAL The ultimate disposal of an askarel-filled transformer may be accomplished in either of two ways. a. Complete drainage and dismantling with tha proper dispose! of tha askaral liquid and askeref-soaked components as described above. b. Disposition of askaral transformers by means of junk or scrap dealers should be avoided unless a transformer is first drained, followed by soaking of the interior with a suitable solvent, such as kerosene. Accumulated liquids and warnings are to be disposed of as dansfeed earlier. IX. Expwud Sarvio* LIf* Manufacturers indicate that property designed end installed eikarei transformers are expected to give trouble-free service for at least 30 years. Since ftetmntroduction in 1032, the manufacturers report finding the ovegglr failure rate to ba less then 0.5% for ell units under fast end service conditions. The Edison Electric Institute's report (1956-10581 on their member utilities publishes the failure rate for askaral transformers as 0.13 per hundred banks per year. Mr. Frank M. Clerk, who invented transformer eskareli at the General Electric Company in the early 1030s, made tha highly pertinent comment based on- his many years of experience with G.E. Pyranoi (askaral type) transformers that - 'The Important thing k to kaap thorn dry - otharwiaa /ease tham a/ona These words of wisdom became especially applicable in more recent years when welding shut rather than gasketing became the mein method of staling askarel transformers. These units are sold with the understanding that the liquid is In a normally hermetically closed system. X. General Characteristics of Transformer Askarei Fluid Appreciation of the following characteristics, as given in the IEEE Guide, leads to understanding tha raasons for selacting dialectic breakdown voltage and moisture as the prime practical tests to judge the quality of transformer askarel fluid. Also, due to these characteristics the power factor of transformer askarel will be normally much higher than tha corresponding values for mineral ok. in comparison to mineral insulating oil, askarel Is a relatively polar material; 1a., its molecules are dipoles, fret to rotate around their axes end responsive to orientation by electrical forces. Askarel also exhibits a much higher dielectric constant and capacitance then insulating oil, end thee* differences must be kept in mind when interpreting electrical test data. Because it Is relatively polar, and possesses high solvency power, askarel it much more electrically sensitive then mineral oil to traces of extraneous soluble polar materials, and consequently the choice of construction* materials destined for use in askarel it very critical. This sensitivity is reflected in the power factor and resistivity (specific resistance) of the askarel. It is important to note that, with the exception of water, the dielectric breakdown voltage of askarel is not generally adversely effected by many of the soluble polar materials to which its power factor and resistivity (specific resistance) are so sensitive, in fact, the dielectric breakdown voltage of askarel Is somewhat greater than that of insulating oil. Therefore, the values assigned these dielectric fluids in newly supplied transformers are X KV min. and 20 KV min., respectively. As with insulating oil. askarel must be kept dry. It can pick up moistura from exposure to humid atmosphere. Under similar conditions of exposure, askarel can pick up nearly twice as much moisture when measured on a parts per million weight basis. XI. Sampling Transformer Askartf Fluid The following precautions about sampling are quoted from the IEEE Guide. "Representative samples, whether of the complete contents or only parts thereof, are extremely Important from the standpoint of evaluation of the quality of the product sampled. Obviously careless sampling procedure or contamination in the sampling aquipmant will result in sample that Is not truly representative. This generally leads to erroneous conclusions concerning quality and incurs loss of time, effort, and expense involved in securing, transporting, and testing the sample. It is strongly recommended that all of tha procedures and precautions outlined in the latest revision of ASTM D 023 (Sampling Electrical Insulating Liquids) be followed. "Because of the high specific gravity (relative density) of eskarei (greeter then 1), water and some other impurities are most likely to be found at or near tha surface. The top sample, therefore, is considered to represent the worst condition." XII. Evaluation of Askarel Received in New Equipment Some users of askarel equipment find it desirable to make "as rectived tests" on all equipment. It is quite common to use the dielectric breakdown voltage test end visual appearance as the most significant tests. If suitable equipment and trained personnel ere available additional information may ba obtained from the power factor, color, and moistura content tests. In sampling askarel contained in apparatus extreme care must be exercised in order to obtain representative sample. ASTM Method 0 923 should be followed. New equipment with askarel exhibiting the following characteristics Is considered acceptable: Dielectric Breakdown Voltage Color Condition - Visual Water Content Power Factor at 26C X KV min. 300 max. (Strew color) Clear X ppm max. * ASTM Methods D 877 D2129 D 1702 D 1633 D 924,0 180 'The power factor of eskarei taken from new transformers, reactors end accessory equipment con reflect the presence of moisture, dissolved polar compounds, or other contaminants and may very with tha type of equipment from which the temple was taken due to the different retioe of liquid-to-tolld insulation and to the high solvency power of the eskarei. Given an acceptable water content end dielectric breakdown voltage of the askarel as Indicated above, a high power factor seldom Impairs the serviceability of the askarel within rather broad limits and Is MOMS C 75260 indicative of tha degree of extraneous soluble polar materials present. Recognizing the possibilitv of a wide range of power factors being recorded for askarel in new equipment, it is difficult to establish a single limit which would be acceptable to both suppliers and users for ell applications. However, as a broad guide, power factors up to about 10% at 25C and 60 cycles per second (hertz) do not in general indicate any abnormal contamination providing that the other criteria (water content, dielectric breakdown voltage, etc.) are met. Much higher power factors may indicate excessive contamination or tha misapplication of the solid matariaii used In manufacture in contact with the askarel and should ba investigated. XIII. OMoctrie Breakdown Voltage - Moisture Relationship The dielectric breekdown voltage of askarel is highly sensitive to excess moisture; not sensitive to ordinary dissolved polar materials. While the dielectric breakdown voltage can alto be lowered by severe arcing, askarel turns noticeably black or hat particles of sooty carbon floating in it if erdng has occurred. Then the transformer should be repaired and the askarel replaced. If the dielectric breakdown voltage is checked periodically and decreases significantly - this indicates moisture pick-up, arcing, or both. When the dielectric breakdown voltage has dropped to 20 KV or lets, an analysis for water is necessary. If water is found in excess of 40 ppm at room temperature, its source should be located end corrections When the moisture content approaches 125 ppm (saturation level at room temperature!, the dielectric breakdown voltage of adtarei drops below the value required for efficient insulating. The moisture content should not ba allowed to rise over 70 ppm, sampled at operating temperature. If the moisture content is found to be in e satisfactory range and the dielectric breakdown voltage is low. the transformer manufacturer should be consulted. Table IV shows tha relationship of dieteetric breekdown voltage vs. moisture and Table V indicates the approximate water solubility limits in askarel and mineral oil. Table IV Relation of Dielectric Breakdown Vottaga to Amount of PI--bid Water In Adural and Mineral ON (AST* 01'> 'Witer Content (PPM) 0 20 40 60 i B0 ; 110 Askarel 70 KV 66 , 47 40 38 10 Mineral OH 50 KV 39 30 26 22 5 HONS 075261 Table V Approximate Solubility of Water in Tranaformar Askarel and Mineral Oil c. ?. Amount of Water (PPM) Dissoived Askarel Mineral Oil -30 22 -20 4 10 14 - 0 32 10 60 20 30 86 40 104 6 16 26 41 66 M 128 170 8 10 13 20 33 66 85 130 XIV. Turbidity ... may be the visual sign of unditsolved water, or may indicate dirt. Cloudiness may also result from cold precipitation of tin tetraphenyl "scavenger" that was used in the earlier Pyranoi transformers. This scavenger begins to come out of solution around 16? above aero. To redisiolve it requires heating to 160-200? and agitation. High dielectric breakdown voltage will quickly indicate that any turbidity present is not moisture; that the insulating efficiency of the edtsrai is still excellent. However, If the dielectric strength is below 20 KV, moisture should be determined, using the Karl Fischer method (ASTM D1633-0O). Thi dterfectrie bfMkdown wp/fape rarf for mkmi Mnmprimrffymm hdkitor tormoittun. It It by far the mow important maintenance roar tor transformer adkaref. XV. Chock Points for Maintaining Askarsl Insulation A. General Considerations: Modern askarsl transformers with welded construction or silicone or VIton' gaskets (hand hole-cover, switch end terminal compartment covers! and with properly constructed bushings require tittle or no maintenance. With properly constructed transformers, annual or semi-annual visual inspection and diateetrte breakdown voltage test of the askarel fluid should suffice for routine maintenance checking over many years of However, many askarel units were installed in the tarty 1930s before the development of some of the better modem gazetting materials and before improved designs were developed for sealing out moisture. Such early units should be, and can be, modernized. Leaky or deteriorated gaskets should be replaced. If the askarel has become contaminated, it should be reconditioned. At the same time, a general clean-up of the unit and possible refinishing may be desirable. If it is not convenient to take an old transformer out of service for general repairs, leaky geskets een be seeled temporarily by pointing over the leaky area with epoxy cement. A survey of users indicates a good number of early-built adcarel transformers (over 20 yeors old! ere kept In continuous service in critioei Installations by the following steps (instead of modernisation). The operating units era equipped with compound pressure gauges for reading pressure above and below atmospheric. Positive pressure it maintained on tha shall by introducing nitrogen at 2 to 3 pounds above atmospheric. Regular workmen in the area deity record the temperature and pressure. If a sudden pressure drop it noted more nitrogen is introduced and the gaskets are checked for leaks with soap solution. Leaks are seeled by applying epoxy cement. B. Modern Sealing Procedures: Transformer purchasers should specify the following modern techniques for sealing: 1. Welding Construction: Covert, radiator connections, switch and terminal housings, instrument connections, etc. should be welded. 2. Bushing Connections: A number of bushings have been developed to obtain a proper seal for the electrical connection through the tank wall. They ere classified aa follows: ' 1) Welded Type- (Bushing flange welded to tank wall) a. Cast resin bushing with e molded seal to the bushing stud end external stainless steel or copper flanges. b. Rolled flange bushing with the mctai to porcelain seal at the cap and flange made by being rolled Into grooves in the porcelain over silicone rubber rinp. The seal between the cap end stud is made by welding. c. Porcelain or glass bushings with metal to glass or metal to porcelain stall. 2) Bolted Type {Bolted to tank well) a. Cast resin bushings with either cast or metal flanges containing recessed gasket grooves. b. Porcelain or glass bushings with flanges containing recessed grooves or gasket stop. The gaskets may be either of rectangular or circular cross*section, .usually 14 inch thick. Bushings with recessed grooves ere suitable / to use with oork, cork-nitrite ri^foer combinations or nitrile rubber as weH as gasket materials such as silicone or Viton. 3. Small Size Connections: When not possible to weld, small sice connection seals should be made with FleiriteHic' stainless steel rings. The surfaces must be machined and parallel. The filler between the steel leminetions of the Flexitsllic ring should be either silicon* or Viton. 4. Gaskets for Hand-Hole Covers: Modern design specified silicone gaskets. Such gaskets must be retained in e groove. The groove preferably is machined into the flange or cover. However, it can also be formed by welding concentric steel strips to the flange or the cover. Generally the geekets should bo S/10 to 1/2 in. thick for covers, depending on the depth of the groove or stop. A rectangular cross-section is utuolly The silicone material should be Dow-Corning No. BO Silastic"* or equivalent. This Is e low compression set material. For best sealing 20-26% compression is recommended, with ample eleerenoe in the groove or stop to allow for this compression. No cement Is required. With reasonable cere the gasket is removable without damage end is reuseabie. Silastic SO is slightly swelled by eskarel which contributes to the tightness of the seel. It is not deteriorated by askenl fluid or vapors. It resists weathering and it is tharmelly stable and 'Trademark of Flexitelllc Gasket Company `Trademark of Dow Corning MOWS 075263 flexible at all operating temperatures, (t is an excellent moisture barrier. NOTE: OoW'Corning, Midland, Michigan will supply a list of Silastic 50 gasket fabricators to all transformer manufacturers or users. They will also furnish technical data. Sea Appendix K: Seals, Properties and Procurements. C, The Cider Oee^nj Arrangements: 7.** ;* c.f CGrk or carfe-nltri'* rubber combinations or straight nitrile rubber. 1. Cork-Nitrile Combinations: Covers for the main tank, hand-holes, switch and terminal chambers, relief diaphrams, etc., are held in place by studs welded to the flange or by bolts. The gaskets are cut with openings and placed over the bolts. Often Shellac (Weatinghouse Style No. 1150419, or General Electric Company's Glyptal* 12761 is used to cement the cork to the flanges. The following Is recommended for sealing with the cork -- nitrile rubber combinations: Use Armstrong NC-757 oork-nitriie material or equivalent. The gasket can be cut from e single sheet or by scarfing strips of the material. A convenient method for Joining strip* is to make a Keystone Type Joint. For this purpose, Westlnghouse, Sharon, Pennsylvania, offers their gasket cutter Style No. 328 B614G01. (about $15). The Joints - and also the gasket -- should be cemented to the flange, using one of the above cements. Excess cament should not be allowed to reach the interior of the transformer. After installation and bolting, the outside edge of the gasket should be ooatad thoroughly with epoxy eement to increase weather resistance. This epoxy cement is a paste to which e curing catalyst ia addtd immadiataty btfora usa. Typical are: a. Epoxy Patch Kit #1-C Hyaol Corporation, Clean, New York b. Scotchcast** Resin #4 Minnesota Mining 0 Manufacturing Company St. Paul, Minnesota c. Adhesive A-1 and Activator Type B Armstrong Products Company Argonne Road, Warsaw. Indiana d. Adhesive 9660-1, Synthetics Organic Company, Clevtland, Ohio, used with activator diethyiana triamine (Carbide and Carbon Chemical Company) 2. Straight Nitrile Rubber: When straight nitrile rubbar was originally usad, invariably tha gasket was recessed in a groove. This wet to prevent gasket flow and to protect tha materia) against excessive compression. Although this type seal was not cemented, tha nitrile rubbar gasket is not reuseabte. Slnet grooves or stops have already been provided for tha >` nitrile rubbar seal. Silastic 50 can be easily substituted and is recommended. This conforms with modem practice. XVI. Periodic Fluid Inspection and What Checkpoints Maan On a regular schedule - at six, nine, or twelve month intervals - make a simple visual Inspection of your askarei insulation and run a dielectric breakdown voltage check. `Trademark ef General Electric Company "Trademark ef Minnasets Mtnlni a Mamrfaeuinng Company HQhS C 75264 A. Visual Inspection: Askarel it dear, faint-yellow liquid. After long-term use this color may gradually intensify to light brown. The fluid should remain dear and free from turbidity or cloudiness. Any color change - such as to a green, red or blue cast - indicates extraction of impurities (color materials) from the solid insulation. If a distinct foreign color pick-up is noted, check the complete range of electrical characteristics and notify the transformer maker. Blackening of the atkarel may indicate an arcing condition. Other color changes eione ere not denger signals since the dielectric breakdown voltage li not likely to be impaired. B. Dielectric Breakdown Voltage If the dielectric breakdown voltage has decreased significantly from the lest inspection, or if it has gradually decreased below 26 KV range (at 25aC) - RUN A CHECK FOR MOISTURE. Use . ASTM 01633 (Karl Fischer Method). The dielectric breakdown voltage of askarel is the major indicator to the operating efficiency of your liquid insulation. Besides the visual inspection tests, dielectric breakdown voltage is the only tact necessary to run on a routine basis. Weil-waied askarel transformers have service records of 26 to 30 years on the original XVII. Inspection Checklist 1. if askarel is deer - even though darkened to light brown, has no sediment or turbidity, has dielectric breakdown voltage over 26 KV -- give it the inspection "OK". 2. If askarel is deer, but has foreign color of blue, green, red ... it Is "extracting color" from internal materials. This is not, of itstlf, an operating hazard when the dielectric breakdown voltage stays over 26 KV end moisture remains low. However, this ra occurrence calls for checking into the condition of the interior construction end consulting the transformer maker. However, when sampling the fluid care should be taken to avoid getting color into the askarel from paint that mey be Inside or outside of the sample 3. If the moisture content is found to be above 70 ppm at operating temperature, then sampling should be done at more frequent intervals to estabiidi a possible trend, particularly on outdoor installations. 4. If askarel is deer, but dielectric breakdown voltage drops to 22 or lower KV, and moisture rises over 80 ppm when sampled at operating temperature ... the askarel it ready for simple "refining". If the moisture is near the saturation level (about 125 ppm at room tamparature) a thorough impaction should be made for water droplets in the transformer tank, and even for "globules" of water floating on the askarel surface. If found, the transformer manufacturer should be consulted for reconditioning both the transformer and the fluid. 6. If askarel is dark brown to black, If black pertieies of carbon arc saan. and dielectric strength Is low ... the askarel has been broken down by arcing. It cannot be refined and should be removed and incinerated under proper conditions. (See ANSI Committee C107 report on Uaa and Diapoaai of Aakarai and Adtarai-Soakad Merer/a/s. 115 East 44th Streat, New York. New York 10017). ^ RICH --Shauidnk that sey 6??? * If any of thate^eur Simple impaction tests appear out of the ordinary or the relationship between aopearance end test values is abnormal, contact your transformer supplier for a complete analysis. HONS 075265 Whenever sample it to be shipped to Monsanto, piaase follow the directions shown under: "SAMPLING ASKAREL". XVIII. Contamination in Transformers Moisture, particulate matter and arced decomposition products are known to be serious contaminating influences on transformer askaral. The power factor test normally used for the detection of contamination in m/nera/ oil MM transformers is of little use for this purpose in eskerel filled transformers, due to the extreme effect of extraneous soluble polar materials. This increase in power factor as illustrated in Table VI has no adverse effect on dielectric breakdown voltage. TMVI Effect of Common Insulation Materials on Power Factor and Dielectric Strength (Heat Aged 96 Hours in Askaral at 10CTCJ Material Immersed Askaret After Exposure Power Factor, Dielectric Percent at 60 cvc.. 100*0 Strength 28*C. Non* (control) Slack varnished doth Coppar Prtssbotrd Manila paper Phenol formaldehyde resins Shsttae iron Synthetic rubber 1.0 86.0 1& 2J0 1.6 1J 6.0 6.0 70.0 36 KV 42 40 37 39 41 36 39 39 Similarly, trace contaminants from commonly used construction materials can lower the volume-resistivity of askaral, without affecting Its dielectric breakdown voltage. This is shown in Table VII. Table VII Iffcct of Common Inauletlon Materials on Volume RulciMty of Aduvcl Sample Volume Resistivity x 10* ohm-cm (at WC., BOO Volts DC.. 0.1" gap) 1. New askaral before heat ^Ing 2. New askaral after heat aging 96 hours at 100-C 3. After heat aging with 1 sq. Inch specimens of: i. Phenolic resin tap chenger material b. Paper e. Grade A press board (tan) d. Grade A press board (gray) a. Grade A press board, laminated strip f. Cotton wrapping // O'C g. Glyptet 1279 cwnent, cured 49 hrs. at 190*0 - 2,000 1,900 1200 750 600 500 400 300 100 While trace contamination easily lowers volume resistivity from high i levels, it is important to note that heavy contamination (as whan arced) does not lower the resistivity below the order of 10* ohm-cm. at 100*C. The different behavior of askaral vs. mineral oil in these respects can be summarised as foMowrv. High power factor and low volume resistivity in transformer minaret oils are commonly regarded as "danger signals'* that the oil has deteriorated and broken down chemically or excessive moisture Is present. This is NOT TRUE of askaral liquid insulation unless the dielectric breakdown voltage b low or the moisture content Is high. MOMS 075266 Manufacturers of askaral type transformers point out that it is quite well known that askarei transformers with initial power factor of the askaral fluid in excess of 50% at room temperature and 80 Mr are gmnf satisfactory service life. However, there needs to be assurance that both dielectric breakdown voltage and moisture are at satisfactory levels and do not show adverse trends. XIX. ASTM Method For Investigating The Compatibility of Transformer Insulation and Construction Materials In Askarais This method8 uses the change of electrical and/or chemical ehsrsctsrlitlct of transformer askarei resulting from Its controlled xposura to insulation and construction materials, in orbar to evaluate thalr Immediate ma|or "contamination" affect on the askaral fluid. Delayed or long time contamination affects may not be detected. The method also utilizes various physical tests on the insulation and construction materials after controlled exposure to the askaral to determine the compatibility of these materials with transformer askarei. Properly proportioned Specimens of the insulation or structure! materials art immersed in refined askaral for 168 hours at 100 VC in a forced draft oven. Chenges in electrical end chemical properties of the transformer askaral era compared against a oontrol sample of die askaral treated in the same manner, in abunca of the test specimens. Dissipation factor (ASTM D 924) change is one of the criteria used. The askaral fluid is refined by absorbtive treatment to a dissipation factor level of 0.06 max. at 100*0 and 60 Hz and 0.01 max. at 2B*C and 66 HrCorraiponding values of the askaral fluid after heating 166 hours et 100*0 in absence of a test specimen era 0.076 and 0.02 rstpactively. The maximum dissipation factor levels suggaitad for the aakarel after heating in presence of the test specimen are 020 at 100*0 and 60 He and 0.04 at 29*C and 60 Hi. XX. Refining Askaral for Rt-Usa A. Filtering Through Dry Blotter Paper to Remove Moisture and Extraneous Partidei: Most operators prefer portable refining apparatus, such as a pleta prats fitted with a dolly, evailtoit from Sparkier, Mundelein, Illinois or General Electric Company, Pittsfield, Massachusetts; or the earthen cartridge filter type available from Industrial Filter ' Corporation, Lebanon, Indiana. Filter paper liners for the piete prase are available from Carl Schleicher and Schuetl Company, Keene, New Hampshire end manufacturers of filter preawa Haled above. The filter paper must be dried immediately before use. For beet results, spread tha paper for maximum surface exposure in a hot air circulating oven and heat it for 4 to 6 hours at 1UPC. Circulate tha askarei hot (but not over 4<PC) through the filter fitted with the dry paper liners. After filtration tha dielectric breakdown voltage of tha askaral should be 36 KV minimum. 1. Precautions: Filtering dtouid not be dona whan tha relative humidity exceeds 76%. 2. Any flexible hoses and gaskets on tha refining equipment should be lined with or made of materials that wiH not ba softened by oontact with askaral fluid. (Matertail lined with Silicone, Viton or Teflon* or flexible metal materials art suitable.) MGNS 075267 !n proem of pubMeatton by ASTM, as of tfHs wrtttnf. r Table VIII Quids to Roto of Dissolved Wator Removal Filtering Askerei Through a Papar Praa Paper Prw Watar in Atkarai PPM 116 36 22 18 12 10 10 B. Disposal of Solid Wastas: The ANSI Guide states that, "All Solid wastas which have bean saturated with askarei should be disposed of by the following procedure: 1. The saturated wastas should be pieced into leak-proof containers and transported to a supervised dry iandfHI site moating State requirements. Alternatively, they can be disposed of by incineration in State-approved facilities. 2. Solid absorbents used for spills can be disposed of unoontained in the supervised dry landfill site; transport to the site should be in dosed containers. Alternatively, incineration can bo used in accordance with per. B (See Section 4 for facilities).'' C. If the solid insulation of the transformer requires drying, consult the transformer manufacturer or an apparatus service shop, as in such case oven drying is preferred. D. Earth Treatment for Maximum Improvement of Power Factor end Volume-Resistivity: We question whether pumping and filtering the Quid solely to achieve a change in power factor or volume resistivity alone is lustified in today's ecological dimate regarding PCBs. We recommend that in these situations the original transformer manufacturer be oontacted. 1. Procedure: The askarei liquid mould be relatively dry prior to the ` " ' earth filtration. As a coating on the filter paper surface use finely divided Attapulgus day or Fuller's earth dried and activated by heating for 12 hours at 300-360T immediately prior to use. The amount of earth used dtouid be 0.1 to 02 percent by weight on the weight of the askarei to be treated. Askarei weighs about 12.6 pounds per gallon. To deposit the earth evenly, stir one-third of the earth with a smell portion of askarei in a dean container. Pump the mixture through the filter end follow with two more one-third portions. Then circulate askarei taken from near the top of the transformer, pass It hot (not over 66-60*0 through the earth-coated filter end feed back through the bottom transformer outlet. Continue circulation until the fluid is deer and test shows that the electrical properties ere fully restored. Effect of Earth on Removal of Scavengers Only slight and insignificant km by salactiva absorption of tin tetraphanyi and epoxides occurs when askarei is refined by treatment with 0.1 to 0.2 percent by weight of earth. To remove significant amounts of the scavengers requires repetitious treatment with much larger amounts of earth. MGNS 075266 \ /frTLtnW Q I7 ja jzt Approximate Relationship Showing th^_ ^^Insignificant Effect of Power Factor and Volume-Resistivity on Dielectric Breakdown Voltage of Transformer Askarel. Power Factor (60 eye.) loot: 26-e 2% 65% 15% 20-25% 40-50% 0.05% 0.1% 0.7% 2.0% - Ci*ohm-qm tel Breakdown 1(XPC, 500 Volts Voltage DC. 0.1M gap) 25*0,0.1" gap 1500 600 100 00-70 25 35 KV 35 35 35 35 XXI. Clwning Arcad Tnrnfonntra If a unit has arced so that the askarel is no longer fit for use, a thorough cleaning of the unit it necessary before refilling with new askarel insulation and returning it to service*. Follow this procedure: A. Drain out ail dark, carbon-contaminated askarel. Arrange to have the scrap fluid incinerated under proper conditions. (See ANSI Committee C107 report.) B. Carefully brush carbon deposits from internal parts and insulation, using a soft bristle brush making sure that insulation is not damaged. C. Flush thoroughly using new askarel - not an oH, not a cleaning D. Flush a second time with fresh askarel; drain; than fIM to the proper level with new askarel. E. Energize transformer to warm the fluid for 24 to 48 hours; then circulate the askarel through a filter, returning it to the unit filtered end reedy for um. "This assumes that the erne ef areine has been wtabllshcd and correctton* made. When severe areine occurs, major repairs are usually neeeamry and ike unit XXII. Sampling Aikvri Take a sample as eloaa to the top of the liquid surface as possible. Many large askarel transformers have built-in sampling tuba near the surface for convenient sampling. Than, to make sure that your sample truly represents your askarel insulation, take another temple from the bottom. If additional sampling tube connections are contrived on the valves for easier sampling, make the tubas of dean glass, stainless steel, aluminum or tin for rigid types; and silicone, or Vlton or Teflon tubing for flexible types. Uss NEW containers for the askarel sample. A new and thoroughly predried smeil-mouth quart glass bottle fitted with a Bakeiite* screw cap with aluminum or tin cap liner is recommended for quick, on-site testing. (If complete analysis is to be made, a 5-pint size sample is required.) Be sure that the new bottle does not stand open to collect dust or moisture. Rinse the sample bottle and cap lining two or three times with askarel from the transformer, than fill it. If the sample wkl be tasted promptly, a dear glass bottle can be und If sample it to be stored Indefinitely, use an amber glass bottle or wrap dear glass with aluminum foil. A. Select e dry day. Do not sample insulation on a warm, moist day when humidity exceeds 75%, and... 'Trademark of Union Carteids Corporation HONS 075269 B. Mike iur that the askarel is et leeit es warm at the surrounding air. (Cold liquids can condense moisture from humid air.) C. When sampling askare) from transformers, it is best to take the sample when the unit is warm and operating at average or maximum load, especially for a check on moisture as reflected by a dielectric breakdown voltage test. Sampling the warm askarel more truly represents its condition during operation. Experience shows that water will migrate from a transformer's solid insulation to the askarel liquid and vice versa, depending on temperature, Therefore, when the transformer is hot, the moisture Is most likely to be found In the liquid. This accounts largely for periodic variations in dielectric breakdown voltage. For example, a relatively high dielectric breakdown voltage may be found during winter months and a relatively low dielectric breakdown voltage during the summer months on samples taken from the same unit. When tatting has bean completed, the remainder of the fluid sample should be destroyed by high temperature Incineration described In Section VIII. orch HONS 075270 IB AsJkairol MIM ^Mdhs aimnil Temiiiiinai Onanmlbeirs I. Introduction High voltage Had* art usudly connectad to askard or mineral oil-tilled network treniformeri and powar center! through terminal chambers and twitches. In soma cases terminal chambers era not used, and the high voltage leads are connected directly to the twitch terminals. They may be filled with either eskerel or mineral oil. Switches are usually rotary or drum type fitted with e revolving block and porcelain unit as the principal dement arranged for three-phase service. Askard transformers with attached switches have been in use for about 30 years. Whan they ware first introduced, the eveMabilitv of insulating end gasketing materials was rather limited and even the best materials el the time had no service history. As a result, inadequate gasketing matarids such as cork, nitrile rubber, and nitrilt rubber-end-cork portides were used. While satisfactory for a limited period of time, theta matarids cannot be depended upon for the expected long life of the equipment. The tarmind chamber is usudly above or below the switch oompertment and separated by a staid wdl through which the budungs art Inserted. When budiings are properly selected and correctly Installed, there is no leakage from one compartment to the other. With poor buehing seals, and the termind chamber above the switch, potting compounds or cable oil can seep into the adeerd. When the termind chamber is below the switch, askard can drain into the termind MOMS 07527X II. Sources of Contamination There are three possible sources of contamination for askard in witches end terminal chambers; they rank in this order of frequency: (1) water entering through poor gaskets; (2) decomposition products from arcing when switch it used to break magnetising current: 13) entrance of pothead or coble compounds throutfi leaky budiing seals. Unlike an askerd transformer where the amount of contaminant is llkdy to be very tmdl (probably only trace amounts) in rdalien to the volume of askard fluid -- in switches or termind chambers with faulty ads, the amount of contamination can be reletivdy large. Experience hat drown that, bated on the number of inttdled eskerd-switch units, the percentage of failures is extremely smdt. When investigated, it hat been found that most failures originate in the switch ' chunber. Water is the chief source of contamination. However, heavy contamination of askard with petrolatum and aaphdt materiel, due to leakage, have caused a ftw failures. Petrolatum it used frequently for filling terminal chambers. When either cable oil or petrolatum seeps into askerd, no great harm results. The fire resistance will be somewhat decreseed and power factor of the askard will Incrwas with an accompanying drop in resistivity. While highly undesirable, it is doubtful that failure of the unit results. Where ssphdtic compounds ere used in place of petrolatum, the denger is increased somewhat because asphaltic contamination may cause excessively high dielectric lessee in the adiarel. Whan the terminal chamber Is below the switch chamber, the potting compound can be contaminated by akirei if the bushing sedi ere leaky. This is undesirable because the askerd will Increase the power factor end conductivity of the potting compound or cable oil end devdop hMt from dielectric loss. If this mixture Is drawn into the cable Insulation. cable tellur* Is Misty. This again emphasizes the importance ol tight bushing ataembiMS. III. Sealing Switch#* and Torminel Chambers Proper bushing construction, use of Silastic seals and walding wherever possible is highly desirable (as covered in Section A). Where an elastomeric seal is to bo used In contact with both aakarel end petroleum oil, DuPont's Viton is suggested. For new equipment the user dtould specify these modern seeling arrangements to keep out oonContinents end minimize meintenence. IV. Askerel Used Under Mild Arcing Conditions The IEEE Guide for Transformer Askerel colls attention to the ' following: "Askerel it used, to some extent, in apparatus where it Is subjected to light intermittent arcing, such as in telfaontained induction regulators, where operating switches ere continually producing slight arcs, In transformer dehnsrgfomg switches, etc. under normal conditions, deterioration of the askerel Is very slight. However, improperly adjusted or detective switches in this type of apparatus can product excessiva and prolonged arcing and accelerated deterioration of the askerel. It Is recommended that when askare! b uaed under these conditions, chocks of the liquid, especially for moisture end dielectric breakdown vottegs made more frequently than when It b used only m e oooling and Insulating fluid. Deterioration of this typo b indicated by e blackening of the liquid. It can usually be reconditioned as previously described. Special attention should be given to maintaining tht ictvangsr at the appropriate concentration." V. Maintononoo for Askerel Filled Switches A Switches tacd for grounding after power source has bean de-energized will not undergo arcing. B. Switches interrupting magnetizing current will be subject to arcing; the amount of decomposition wM depend on power Interrupted, time and frequency of operation. As a general rule, die liquid should be checked after 5 to 90 operations. 9. On newly installed switches, check the aakarel at 3,6 end 12 month intervals; If found satisfactory, Wredt once annually thereafter. With proper attention to the gasketing of covers and bushings, experience wtH probably indicate that leas frequent Inspection b warranted. 2. Check askarai for: > a. Dielectric breakdown voltage {ASTM D677): It mould be 26 KV minimum. If dielectric breakdown voltage it low, confirm presence of water by Karl Fischer method ASTM D-9833. Filter to remove moisture. Dielectric suength should then be 30 KV minimum. b. Pretence of carbon from arcing: Fluid should be relatively free of carbon. If badly arced and vary black, replace fluid. If only minute amounts of carbon are present, filtration b recommended. Check power factor of liquid (should not be over 9% at 26"C and 00 cycles). Flush out switch chamber with several gallons of fradt askarai before refilling. 3. If there b discoloration, high power factor, detectable change In apeeifb gravity or refractive index, or If fluid flashes below 2BPf, there Is a possibility of seepage of potting compound Into the switch compartment. In this case, oorrect any leaky bushing seals with proper replacements and fUt with new askerel. 4. If terminal chamber b below switch, check potting compound for pretence of eekarel (can usually ba detected by odor or by an increeee in specific gravity). If askerel h present, correct any leaky bushing seals with proper replacements, and renew compounds. 6. Examine cover gaskets visually. Deterioration can ba detected ZT's/KN \ __ f Uy#krl/ 'p *r KONS G75272 bv swelling end cricking of the exposed edge, in cases of severe deterioration, liquid seepage is usually present. 6. Check for leakage at packing gland of switching shaft. If leaking, repack with a Silastic ring type gasket. VI. Aakarol Under Excessive Temperature or Fault Conditions The IEEE Guide also points out that, <Y^ " "Chiorobenrenes uteri,,in transformer askards begin to boil at temperaturesaboutTOEGfunder atmospheric conditions. If the material is heated to such high temperature in a sealed system, pressure develops. Pressure will also develop in thi system if the askard is arced sufficiently to generate copious hydrogen chloride Therefore, it is recommended that wherever possible, seeled aekarel filled equipment be provided with pressure relief devices. These devices must be large enough to provide immediate relief at definite pressure, end to prevent further buikf up of praeaure if decomposition continues. It must be remembered that the presence of devices of this son does not necnsarily preclude the rupturing of containing vessels, since pressure build up can be extremely rapid under violent arcing conditions." MONS 075273 (C AmaHytfkall Seirvkes on Tir&onskrrniiner AsCiairel AvafiQaMs Firama Mmsamtl<a Transformer users not wishing to make their own fluid analyses can obtain the service from Monsanto. Simply contact Monsanto and specify whet analyses are wanted. You will be tent the proper-sized, dean sample container, fitted with a proper label. Whan you receive this, carefully take your sample (following the procedure for sampling in this guide). Sand the container to Monsanto's laboratory. Charges listed indude sample container, shipping, handling and laboratory coats. Types of Analyses Available Analysis 1) ROUTINE MAINTENANCE CHECK Total Charge: *26.00 To determine the general condition of the fluid and find vdtather further analysis is necessary, (one-quart ample required) Properties Tested Dielectric Breakdown Voltage Color end Condition Moisture You wUt bo notified of the results of this tost. If further testing is indicated, and you wont complete analysis, you wfH be sent a five-pint sample container. This sample will be used for the fdkmring series of lasts: Analysis 2) COMPLETE ANALYSIS Total Charge: *55.00 (Lto determine die extent of fluidoontamlnotlon.^ffoorth refinement to determine vrttet degree of restoration of electrical and Mooting properties le possible, (dTmeek test to see how die fluid responded to earth treatment. a) Complete Analysis: to determine die extent of contamination Properties Tntod Free Chlorides Color and Condition Acidity . Specific Gravity Dielectric Breakdown Voltage heiractive Index Power Factor, Dielectric Constant, end Resistivity M Earth Refinement Response: ____ Consists of treatment for 2J hours at 50-60*C. with 0.1 to 0.2 percent by weight of properly conditioned Attapulgua day and than filtration through dry ffftor paper, e) Analysis Altar Laboratory Earth Refinement: Properties Toiled Acidity Refractho Index Dielectric Breakdown Voltage Water Power Factor, Dielectric Constant, and Resistivity Free Chlorides You wM be notified of the remits of this test series cm your sample. Than after refining your entire transformer fluid All you can check on the rendu by requesting die following analysis: Analysis 3) ANALYSIS AFTER EARTH REFINEMENT Total Charge: *35.00 (This charge will not apply when analyses 1 and 2 have already been made.) To determine whether the entire lot of the askare! fill responded to the same extent as the laboratory sample, (five-pint (ample required) Properties Tested Free Chlorides Color end Condition Acidity Refractive Index Dielectric Breakdown Voltage Water Power Feetor, Dielectric Constant, and Resistivity To arrange for the tests described above write to the following address: Paul G. Bentgnus Monsanto Company 500 North Lindbergh Blvd. St. Louis,Missouri *210* temples to be tested should be deerty marked for identification and sent directly to: Monsanto Chemical Company W. G. Krummrieh Laboratory Attention: R. Kuster HONS 075234 APPENDIX A Aikarti Stability and Composition of Arc Formed Gat: Askarai insulation is on* of th* most inert, chemicaliy-tubie heat resistant, non-oorrasiv* liquids knemm. It will not break down, oxidize or sludge when exposed to air and high temperatures, 150*C. or even somewhat higher. Arcing, however, will break down the oompound to liberate some hydrogwi diJoridc and nail mounts of carbon. APPROXIMATE COMPOSITION ARC FORMED GAS FROM TRANSFORMER ASKAREL BLENDS ASTM TYPES D ANO F (INERTEEN M201KA AND PYRANOL A11BSB-2. RESPECTIVELY) Gas carbon monoxide carbon dioxide oxygen inert gases Itydregtn ohlorMt (note the absence of phosgene 1 Amount 0.3% 0.3% 0.6% 1J% 07.3% This art-formed gas from ASTM Type 0 and Type F transformer adtareis Is non-flammable and non-oombuetfeie. For all practical purposes, the amount of gas liberated from askarel under a given set of arcing conditions is about 100 cubic cant(meters per kilowatt second. APPENDIX B EFFECT OF TEMPERATURE ON DIELECTRIC BREAKDOWN VOLTAGE OF ASKAREL Temperature *C -00 -40 --20 0 20 40 00 so Dielectric Breakdown Voltage ASTM D877 67 KV 03 57 K SO SO 48 46 MGNS 075275 APPENDIX D C0MPARI8ON OF THI APPROXIMATE VISCOSITY IN SAYBOLT UNIVERSAL SECONDS OP TRANSFORMER ASKARELS AND MINERAL OIL Temp. "C -20 0 20 40 w so 100 Pyranol A13B38-2 yjooo 100 70 45 39 34 30 10C Mineral Oil 1,000 150 85 49 40 34 30 Inarteen 54201 KA 2300 196 85 50 40 38 33 APPENDIX E 1 APPENDIX 0 MutCgwity Ow ttw tamparatura ranyt of 2B* to 12PC tha apodfic hooC of Pamfoooot oknl h dam fo 0J0 cdorim par (ram par Ol(Hl. APPENDIX H Caaffldant of Eapawalon Th# aaanta aoaffMam of anpawaloii of fnnatannar mkaral oaartha (dlon mould trump lo IDEE (dlpm on liaafjm from 20 to 10gC. 0*0001 ranfi 20 to IDPC la tXtralvefC. t APPENDIX I Fire Resistance Aiharcit of wloui oompoeitlonel aakerei type. art wed. Under arcing oondltlom tha gases produced, while consisting of chloride can yield varying amounts of oombwtiMe gam depending upon tha and ceHuiotic or other organic material! may, whan arced, produce geaeoui mixture! which ara modaratafy flwnmabia, Aa a precaution, such garni ihoukl be removed from tha adtarai hy bubbling dry nllragan through tha adterel and fhnMng the gat apace with dry nitrogen before any work it parformad on tha apparatus. MQNS 075276 <=T) A 7~'T" APPENDIX J 8--1. hwwtlw and Procurement Dow Corning Corporation, Midland, Michigan with Districts at Atlanta. Soaton, Chicago, CJevticnd, DaNaa, Lot Angeles. Now York City. Washington. D.C. and Toronto hat awottabla Bulletin 094)19, August 1963 antidad "Silastic Design Data'*. Thii Ifm tha gasket fabricators throughout tha country from whom tha MSMaatic 60" geskating can ba purchatad In sheet, extrusions or moidad ihapat. OanaraNy Silastic 60 ihaat goods ara stocked by focal dia cutters, hanca, could ba ganarally purchaaod locally. Usually wnaN quantitfat of gatkati ara dia cut. If largar quantities ara naadad, tools arc made of tha same type mad so cut other elastomers, Whart tot getkat b extruded for fitting into maohinad groove or between pasket stops. DomComtaB adaiees use of scarred Joint. This Joint Is than camantad udng Dow Coming's Silastic 140 (dear) or tilth RTV 791 Iwhital materials, which ak cure. Dow Coming points out that tha local "rubber** fabricators purchase tha Silastic 60 in btilat tom* TUN b worked on a roil mW In preparation for sheeting or extrusion. Than to obtain tha desired physical propartisi tha Nbricofar must ooto curt die Siiastb 60 for 34 hours at 4S0*f. SPECIFICATIONS* ASTMD67S ASTMD412 ASTMD412 ASTMD38B Color Specific Gravity at 77f Hardhaaa, Shore A. Scale TanaNa Strength, pal, mkv Elongation, percent, min* Comprmajon Sot after 22 hra. at 300T, percent, max. Whit* 1.300.03 45 to 00 800 260 30 *AN physical propartias maawcad on 0JI7S imdi thick mmplas moidad S minutes at 24tTF, and ovan cured 24 hour* at 4S0f. APPENDIX K NGNS 075277 MONSANTO INDUSTRIAL CHEMICALS COMPANY (ncialtv woouct* arout (00 N. LINOMROH M.VD. rr.Louit, mimouri him Tha information hatain rspanflnp obtaining optimum PMutts from aafcarol fluids in your tronaformsr has boon aceumutatod by Monaanto tar osar 40 yaar from thaaaparlanaa of mafcarsand usart of aafcarol tranaformanand It Is baHawad 4N bo hateful. Mottling harain OwN ba conatruad as applying to othar than --fcaral insulation. Data and maintananea suggasilona harain do not sooty to tha ottiar aawyonantt of tha tranatonwar. AH opatafiwp and mabdananaa sugpaationi raoommandad by tho manufacturer of tha Oanaformar smifd also ba avavtdta toppupo. isnaiMi thsaa mafcitenonoa dbacttona apply only to tha aafcaral insulation, Monsanto dbdeime any HatoHKy for ttorwajs to proparty or injury to panonariiiR|fromtranaloniwraporailo^ - I HONS 075278