Document evKYQ35jGOxodDJgavLRRp1Mm

594' CHAPTER 28 1949 Guide ness than that determined by the use of Fig. 6. The data in Fig. 6 are based on conditions of insulation exposed to the air, whereas normal ground temperature is: substituted for air temperature in determining the temperature difference for use with the chart when applying it for under ground pipe line estimates. REFERENCES 1 Heat Loss from Copper Piping, by R. H. Heilman (Healing, Piping and Air Conditioning, September, 1933, p. 468). 1 Handbook of the National District Heating Association, Second Edition, 1932. * Theory of Heat Losses from Pipes Buried in the Ground, by J. R. Allen (A.S.H.V.E. Transactions Vol. 26, 1920, p. 335). 4 Rapid Method of Determining the Economical Thickness of Pipe Insulation, by Utley W. Smith (A.S.H.V.E. Jouhnai, Section, Healing, Piping and Air Condi tioning, October 1947, p. 118). CHAPTER 29 DISTRICT HEATING Steam Distribution Piping, Selection of Pipe Sizes, Conduits for Piping, Pipe Tunnels, Overhead Distribution, Inside Piping, Metering, Steam Requirements, Rates, Utilization, Automatic Temperature Control THE term district healing refers to the heating of several buildings from a central plant as in the heating of portions of cities, or to the heating, of groups of buildings as in institutions and factories. It is usually prefer able, in a group of industrial or institutional buildings, that they be heated from a central plant rather than by individual plants. Fuel can generally be burned more efficiently, less labor is required, and often a central plant is 'cheaper to install. Those phases of district heating which frequently fall within the province of the heating engineer are outlined here with data and information for solving incidental problems in connection with institutions and factories. Some data are included to cover the piping peculiar to heat ing systems which are to be supplied with purchased steam. A complete district, heating installation should not be attempted without a thorough study of the entire problem by men competent and experienced in that industry. - STEAM DISTRIBUTION PIPING The methods used in district heating work for the distribution of steam are applicable to any problem involving the supply of steam to a group of buildings. The first step is to establish the route of the pipes, and in this matter since the local conditions control the layout little can be said re garding it. Having established the route of the pipes, the next step is to calculate the pipe sizes. In district heating work it is common practice to design the piping system on the basis of pressure drop. The initial pressure and the minimum permissible terminal pressure are specified and the pipe sizes are so chosen that the required amount of steam, with suitable allowances for future increases, will be transmitted without exceeding this pressure drop. The steam velocity is therefore almost disregarded and may reach a very high figure. Velocities of 35,000 fpm are not considered high. By the use of this method the pipe sizes are kept to a minimum with conse quent savings in investment. The steam flowing through any section of the piping can be computed from a study of the requirements of the several buildings served. In general a condensation rate of 0.25 lb per (hr) (sq ft of equivalent direct radiation) is a safe figure. This allows for line condensation which, how ever, is a small part of the total at times of maximum load. Miscellaneous steam requirements such as laundry, cooking, or process should be indi vidually calculated. The steam requirements for water heating should be taken into account, but in most types of buildings this load will be relatively small compared with the heating load and will seldom occur at the time of the heating peak. Unusual features such as large heaters for swimming pools should not be overlooked. The pressure at which the steam is to be distributed will depend upon' (1) boiler pressure, (2) whether exhaust or live steam, (3) pressure require-1 ' ' ' 695