Document ev6vZy9gn8R6G71ELxdxGbRre

3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Final Report Analysis of PFOA, PFBS, PFHS, and PFOS in Aqueous Samples from 3M Decatur, Alabama: Groundwater Treatment Plant GAC System November 2013 Laboratory Request Number: ISO13-07-10 Method Requirement: 3M Method ETS-8-044.1 Report Date - Date of Last Signature Testing Laboratory 3M EHS&S Operations 3M Environmental Laboratory Building 260-5N-17 Maplewood, MN 55144-1000 Requester Gary Hohenstein 3M Building 224-5W-03 Saint Paul, MN 55144-1000 Phone: (651) 737-3570 The testing reported herein meet the requirements of ANSI/ISO/IEC 17025:2005 "General Requirements for the Competence of Testing and Calibration Laboratories", in accordance with the A2LA Testing Certificate # 2052.01. Additionally, the laboratory's quality system has been audited and was determined to be in conformance with the EPA GLPs (40 CFR 792) by an independent A2LA assessment. PAGE 1 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 3M Environmental Laboratory 3M Environmental Laboratory Technical Director: William K. Reagen, Ph.D. 3M Principal Analytical Investigator: Susan Wolf Report Author: Chelsie Grochow Analytical Report ISO13-07-10 3M Decatur Groundwater Treatment Plant System; November 2013 Sampling Report Date: Date of Last Signature 1 Introduction/Summary The 3M Environmental Laboratory analyzed water samples from the groundwater treatment plant GAC system at the 3M Decatur, AL facility. Water samples were collected by Weston Solutions personnel on November 18, 2013. Samples were returned to the 3M Environmental Laboratory for analysis of Perfluorooctanoate (PFOA), Perfluorobutane sulfonate (PFBS), Perfluorohexane sulfonate (PFHS), Perfluorooctane sulfonate (PFOS) under laboratory project number ISO13-07-10. Analysis of the samples was completed as specified under 3M Environmental Laboratory General Project Outline (GPO) number GPO11-1006. The 3M Environmental Laboratory provided sample containers for seven sampling locations; ACI, ACM2, ACE, WW8R, WW9R, WW10R, and WW11R. The sample set consisted of a field sample, field sample duplicate and a field matrix spike. Each empty container was marked with a "fill to here" line that corresponded to a final volume of 200 mL. Containers reserved for field matrix spikes were fortified with an appropriate matrix spike solution containing all analytes prior to being sent to the field for sample collection. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with internal standards and surrogates prior to being sent to the field for sample collection. Samples were prepared and analyzed by method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Select internal standards were used to aid in the data quality objectives. Table 1 summarizes the sample results using the analytical method identified above. All results for quality control samples prepared and analyzed with the samples will be reported and discussed elsewhere in this report. PAGE 2 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 1. Sample Results Summary 3M LIMS ID Sample Description ISO13-07-10-001 ISO13-07-10-002 ISO13-07-10-004 ISO13-07-10-005 ISO13-07-10-007 ISO13-07-10-008 ISO13-07-10-010 ISO13-07-10-011 ISO13-07-10-013 ISO13-07-10-014 ISO13-07-10-019 ISO13-07-10-020 ISO13-07-10-022 ISO13-07-10-023 DAL-GW-ACI; Sample DAL-GW-ACI; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-ACM2; Sample DAL-GW-ACM2; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-ACE; Sample DAL-GW-ACE; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-WW8R; Sample DAL-GW-WW8R; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-WW9R; Sample DAL-GW-WW9R; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-WW10R; Sample DAL-GW-WW10R; Sample Dup Average %RPD Sample/Sample Dup DAL-GW-WW11R; Sample DAL-GW-WW11R; Sample Dup Average %RPD Sample/Sample Dup PFOA Concentration (ng/mL) 2190 2190 2190 (1) 0.0 0.0539 0.0527 0.0533 (2) 2.3 0.511 0.445 0.478 (2) 14 3060 3010 3040 (1) 1.6 2910 2980 2950 (1) 2.4 2410 2380 2400 (1) 1.3 1300 1330 1320 (1) 2.3 PFBS Concentration (ng/mL) 1100 1090 1100 (1) 0.91 1130 1110 1120 (1) 1.8 0.620 0.563 0.592 (2) 9.6 363 360 362 (1) 0.83 301 309 305 (1) 2.6 301 304 303 (1) 0.99 286 288 287 (1) 0.70 PFHS Concentration (ng/mL) 1320 1340 1330 (1) 1.5 0.0728 0.0670 0.0699 (2) 8.3 0.401 0.331 0.366 (2) 19 1440 1440 1440 (1) 0.0 1300 1370 1340 (1) 5.2 1120 1120 1120 (1) 0.0 673 687 680 (1) 2.1 PFOS Concentration (ng/mL) 2260 2220 2240 (1) 1.8 0.206 0.198 0.202 (2) 4.0 0.0979 0.0472 0.0726 (2) 70 (3) 4790 4710 4750 (1) 1.7 4430 4640 4540 (1) 4.6 3940 3840 3890 (1) 2.6 1790 1900 1850 (1) 5.9 NA = Not Applicable (1) Reported results were prepared and analyzed by ETS-8-044.1 using external standard calibration. The analytical method uncertainties associated with the reported results are as follows: PFOA 17%, PFBS 18%, PFHS 15%, and PFOS 21 %. (2) Reported results were prepared and analyzed by ETS-8-044.1 using internal standard calibration. The analytical method uncertainties associated with the reported results are as follows: PFOA 15%, PFBS 16%, PFHS 20%, and PFOS 17%. (3) Sample/sample duplicate RPD did not meet acceptance criteria of <20%. PAGE 3 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 2 Methods - Analytical and Preparatory 2.1 Methods Analysis was completed using 3M Environmental Laboratory Method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Table 2. Target Analytes Target Analytes Perfluorooctanoic Acid (C8 Acid) Perfluorobutanesulfonate (C4 Sulfonate ) Perfluorohexanesulfonate (C6 Sulfonate) Perfluorooctanesulfonate (C8 Sulfonate) Acronym PFOA PFBS PFHS PFOS Reference Material Structure Linear + Branched Linear Linear Linear + Branched 2.2 Sample Collection Samples were collected on November 18, 2013 in NalgeneTM (high-density polyethylene) bottles prepared at the 3M Environmental Laboratory. Prior to sample collection, bottles designated for field matrix spikes were spiked in the laboratory with a known volume of an appropriate matrix spiking solution containing PFOA, PFBS, PFHS, and PFOS. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with a mixture of mass-labeled internal standards at a nominal concentration of 1 ng/mL and a mixture of surrogate recovery standards at a nominal concentration of 0.1 ng/mL. Collected sample bottles were received by the laboratory at ambient conditions on November 25, 2013. 2.3 Sample Preparation All samples were diluted with methanol and analyzed for all analytes. Samples diluted 1:10 were prepared by removing a 1 mL aliquot of the well mixed sample and adding 8.9 mL of methanol and 0.1 mL of a surrogate spiking solution. The 1:100 dilutions were prepared by removing a 0.1 mL aliquot of the well mixed sample and adding 9.8 mL of methanol and 0.1 mL of a surrogate spiking solution. Prepared samples were analyzed by external standard calibration. Further dilution may have been applied by using a lower injection volume on the instrument. The ACE and ACM2 sample sets and the Trip Blank sample were prepared and analyzed for all analytes by transferring an aliquot of the well mixed sample into an autovial. Prepared samples were analyzed by internal standard calibration. During the preparation of the laboratory control samples for internal standard calibration, an aliquot of a separate internal standard spiking solution was added to the laboratory control samples (nominal concentration of 1 ng/mL). The sample bottles for ACE, ACM2, and Trip Blank were spiked with an internal standard mix at a nominal concentration of 1 ng/mL prior to being sent to the field for sample collection. The laboratory control samples were analyzed in the same manner as the samples. 2.4 Analysis All samples and quality control samples were analyzed for four target analytes using high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Pertinent instrument parameters, the liquid chromatography gradient program, and the specific mass transitions analyzed are described in the tables below. PAGE 4 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Due to the nature of the sample, the wide range of concentrations found in the sample, and the environmental occurrence of multiple isomers of the laboratory's analytes of interest, the software used for processing the analytical results is not able to consistently integrate the analytical peak, manual integration of the analytical peak is necessary. All manual integrations are performed following the procedures outlined in method ETS-12-010. The consistency of the laboratory's integration is ensured through the training of laboratory personnel, the peer review process required for all manual integrations, the review of manual integrations by the QAU, and where necessary the review of manual integrations by laboratory management. Table 3. Instrument Parameters. Instrument Name Analysis Dates Analytical Method Liquid Chromatograph Guard column Analytical column Injection Volume Mass Spectrometer Ion Source Polarity Software ETS Kirk 12/12/13 - external standard calibration 12/13/13 - internal standard calibration ETS-8-044.1 Agilent 1260 Betasil C18 (4.6 mm X 100 mm), 5 g Betasil C18 (4.6 mm X 100 mm), 5 g 2, 5, or 20 gL Applied Biosystems TripleQuad 5500 Turbo Spray Negative Analyst 1.6.1 Table 4. Liquid Chromatography Gradient Program. Step Number 0 1 2 3 4 5 6 7 8 9 Total Time (min) 0.00 0.50 4.00 6.00 11.0 13.0 13.5 16.0 16.5 19.0 Flow Rate (gL/min) 750 750 750 750 750 750 750 750 750 750 Percent A (2 mM ammonium acetate) 90.0 90.0 70.0 70.0 20.0 20.0 10.0 10.0 90.0 90.0 Percent B (Methanol) 10.0 10.0 30.0 30.0 80.0 80.0 90.0 90.0 10.0 10.0 PAGE 5 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 5. Mass Transitions. Analyte Mass Transition Q1/Q3 Internal Standard (1) Mass Transition Q1/Q3 413/369 PFOA 413/219 [13C8]PFOA 421/376 413/169 PFBS 299/80 299/99 [18O2]PFBS 303/84 PFHS 399/99 399/80 [13Cs]PFHS 402/80 499/99 PFOS 499/80 [13C8]PFOS 507/80 499/130 [13C4]PFOA surrogate 417/372 [13C8]PFOA 421/376 [13C4]PFOS surrogate 503/80 [13C8]PFOS 507/80 Dwell time was 20 msec for each transition. The individual transitions were summed to produce a "total ion chromatogram" (TIC), which was used for quantitation. (1) Internal standards were used for the analysis on 12/13/13. 3 Data Analysis 3.1 Calibration External Standard Calibration Analysis on 12/12/13: Samples were analyzed against an external standard calibration curve. Calibration standards were prepared by spiking known amounts of the stock solution containing the target analytes into 90:10 methanol: Milli-Q laboratory water. A total of eleven spiked standards ranging from 0.02 ng/mL to 50 ng/mL (nominal) were analyzed. The standards also contained the surrogates at concentrations ranging from 0.02 ng/mL to 25 ng/mL nominal. A quadratic, 1/x weighted, calibration curve of the standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area counts and the resultant calibration curve confirmed accuracy of each curve point. Internal Standard Calibration Analysis on 12/13/13: Samples were analyzed against a matrix-matched stable isotope internal standard calibration curve. Calibration standards were prepared by spiking known amounts of stock solutions into laboratory prepared reagent water. The calibration standards contained an internal standard mix at a nominal concentration of 1 ng/mL. A total of thirteen calibration standards ranging from 0.025 ng/mL to 25 ng/mL (nominal) were analyzed with the prepared samples. Of these thirteen calibration standards, eleven contained the surrogates at concentrations ranging from 0.025 ng/mL to 10 ng/mL nominal. A quadratic, 1/x weighted, calibration curve of the ratio of the standard peak area counts over the internal standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area ratios and the resultant calibration curve confirmed accuracy of each curve point. For each calibration curve, the reference standards of PFOA and PFOS used to prepare the calibration standards consisted of both linear and branched isomers. Each curve point was quantitated using the overall calibration curve and reviewed for accuracy. Method calibration accuracy requirements of 10025% (10030% for the lowest curve point) were met for all analytes. The correlation coefficient r was greater than 0.995 for all analytes. PAGE 6 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 3.2 System Suitability A calibration standard was analyzed four times at the beginning of the analytical sequence to demonstrate overall system suitability. The acceptance criteria for system suitability samples is less than or equal to 5% relative standard deviation (RSD) for peak area/ratio and retention time criteria of less than or equal to 2% RSD. These criteria were met for all analytes. 3.3 Limit of Quantitation (LOQ) The LOQ as defined in method ETS-8-044.1 is the lowest non-zero calibration standard in the curve that meets linearity and accuracy requirements and for which the area counts are at least twice those of the appropriate blanks. The LOQs associated with the sample analysis are listed in Table 6. Table 6. LOQ Analyte Calibration LOQ, ng/mL PFOA Internal standard 0.0240 PFBS Internal standard 0.0250 PFHS Internal standard 0.0400 PFOS Internal standard 0.0232 PFOA External standard 0.0958 (1) PFBS External standard 0.0200 (1) PFHS External standard 0.0200 (1) PFOS External standard 0.0185 (1) (1) The dilution factor was not applied to the LOQ. 3.4 Continuing Calibration During the course of the analytical sequence, several continuing calibration verification samples (CCVs) were analyzed to confirm that the instrument response and the initial calibration curve were still in control. The method acceptance criteria of 100% 25% was met for all analytes. 3.5 Blanks Two types of blanks were prepared and analyzed with the samples: method blanks/solvent blanks and field/trip blanks. Each blank result was reviewed and used to evaluate method performance to determine the LOQ for each analyte. 3.6 Lab Control Spikes (LCSs) Low, mid, and high lab control spikes were prepared for the target analytes and analyzed in triplicate, while only low and high lab control spikes were prepared for the surrogates. LCSs were prepared by spiking known amounts of the analytes into either 10 mL of laboratory-prepared matrix matched water or 1 mL of Milli-Q water to produce the desired concentration. When applicable, the LCSs were then diluted with methanol in the same manner as the samples. Method ETS-8-044.1 states that the average recovery of LCSs at each spiking level be within 80%-120% with a RSD <20%. All LCS samples met method accuracy criteria. All LCSs were used in the determination of the analytical method uncertainty in section 3.7. The following calculations were used to generate data in Table 7. Calculated Concentration * ____ _ LCS Percent Recovery -------------------------------------* 100% Spike Concentration ______ ,, ,, ,, standard deviation LCS replicates LCS% RSD = ------------------------------------- - --------- * 100% average LCS recovery PAGE 7 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 7. Lab Control Spike Results. ETS-8-044.1 External Standard Calibration Analyzed 12/12/13 Lab ID PFOA (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-131212-1 LCS-131212-2 LCS-131212-3 Average %RSD LCS-131212-4 LCS-131212-5 LCS-131212-6 Average %RSD 0.191 0.191 0.191 4.74 4.74 4.74 0.194 0.188 0.184 98.9% 2.9% 5.37 5.32 5.48 114% 1.8% 102 98.4 96.3 113 112 116 LCS-131212-7 LCS-131212-8 LCS-131212-9 Average %RSD 38.2 38.2 38.2 41.5 38.1 38.1 103% 5.2% 109 99.6 99.7 Spiked Concentration (ng/mL) PFOA surrogate Calculated Concentration (ng/mL) 0.199 0.199 0.199 0.223 0.214 0.214 109% 2.4% 4.94 5.22 4.94 5.23 4.94 5.11 105% 1.1% %Recovery 112 108 107 106 106 104 ETS-8-044.1 External Standard Calibration Analyzed 12/12/13 Lab ID Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) LCS-131212-1 LCS-131212-2 LCS-131212-3 Average %RSD LCS-131212-4 LCS-131212-5 LCS-131212-6 Average %RSD LCS-131212-7 LCS-131212-8 LCS-131212-9 Average %RSD 0.199 0.199 0.199 4.95 4.95 4.95 39.8 39.8 39.8 0.219 0.220 0.214 109% 1.1% 5.70 5.76 5.78 116% 0.86% 41.5 40.6 40.0 102% 2.0% %Recovery 110 110 108 115 116 117 104 102 100 Spiked Concentration (ng/mL) 0.199 0.199 0.199 4.95 4.95 4.95 39.8 39.8 39.8 PFHS Calculated Concentration (ng/mL) 0.207 0.202 0.204 103% 1.1% 5.46 5.41 5.56 110% 1.4% >ULOQ >ULOQ >ULOQ NA %Recovery 104 102 102 110 109 112 NA NA NA >ULOQ = analyte concentration exceeded upper limit of quantitation NA = Not Applicable PAGE 8 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 External Standard Calibration Analyzed 12/12/13 Lab ID PFOS (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-131212-1 LCS-131212-2 LCS-131212-3 Average %RSD LCS-131212-4 LCS-131212-5 LCS-131212-6 Average %RSD LCS-131212-7 LCS-131212-8 LCS-131212-9 Average %RSD 0.185 0.185 0.185 4.59 4.59 4.59 36.9 36.9 36.9 0.204 0.197 0.197 108% 1.6% 5.37 5.34 5.38 117% 0.49% 39.3 36.1 36.5 101% 4.4% 110 107 107 117 116 117 106 97.9 98.8 Spiked Concentration (ng/mL) PFOS surrogate Calculated Concentration (ng/mL) 0.190 0.190 0.190 0.215 0.208 0.207 110% 2.1% 4.73 5.11 4.73 5.19 4.73 5.01 108% 1.9% %Recovery 113 109 109 108 110 106 ETS-8-044.1 Internal Standard Calibration Analyzed 12/13/13 Lab ID PFOA (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-131213-1 LCS-131213-2 LCS-131213-3 Average %RSD LCS-131213-4 LCS-131213-5 LCS-131213-6 Average %RSD LCS-131213-7 LCS-131213-8 LCS-131213-9 Average %RSD 0.190 0.190 0.190 1.90 1.90 1.90 19.0 19.0 19.0 0.199 0.190 0.200 103% 2.8% 2.15 2.06 2.04 110% 2.8% 20.7 20.2 19.4 106% 3.3% 105 100 105 113 109 107 109 106 102 Spiked Concentration (ng/mL) PFOA surrogate Calculated Concentration (ng/mL) 0.198 0.198 0.198 0.232 0.225 0.229 116% 1.3% 1.98 2.32 1.98 2.18 1.98 2.28 114% 3.2% %Recovery 117 114 116 117 110 115 PAGE 9 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 Internal Standard Calibration Analyzed 12/13/13 Lab ID Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) LCS-131213-1 LCS-131213-2 LCS-131213-3 Average %RSD LCS-131213-4 LCS-131213-5 LCS-131213-6 Average %RSD 0.198 0.198 0.198 1.98 1.98 1.98 0.213 0.206 0.218 107% 2.9% 2.25 2.24 2.25 114% 0.51% LCS-131213-7 LCS-131213-8 LCS-131213-9 Average %RSD 19.9 19.9 19.9 21.6 21.0 20.7 106% 1.9% %Recovery 108 104 110 114 113 114 108 106 104 Spiked Concentration (ng/mL) 0.198 0.198 0.198 1.98 1.98 1.98 19.9 19.9 19.9 PFHS Calculated Concentration (ng/mL) 0.205 0.198 0.208 103% 2.4% 2.34 2.29 2.35 118% 1.3% 21.7 21.6 20.8 107% 1.9% %Recovery 103 100 105 118 116 119 109 108 105 ETS-8-044.1 Internal Standard Calibration Analyzed 12/13/13 Lab ID PFOS (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-131213-1 LCS-131213-2 LCS-131213-3 Average %RSD LCS-131213-4 LCS-131213-5 LCS-131213-6 Average %RSD 0.184 0.184 0.184 1.84 1.84 1.84 0.203 0.195 0.206 110% 2.9% 2.15 2.11 2.11 115% 1.3% 111 106 112 117 114 115 LCS-131213-7 LCS-131213-8 LCS-131213-9 Average %RSD 18.4 18.4 18.4 21.7 21.1 20.4 115% 3.1% 118 115 111 Spiked Concentration (ng/mL) PFOS surrogate Calculated Concentration (ng/mL) 0.189 0.189 0.189 0.216 0.209 0.219 113% 2.7% 1.89 2.15 1.89 2.08 1.89 2.16 113% 2.0% %Recovery 114 110 116 114 110 114 PAGE 10 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 3.7 Analytical Method Uncertainty Analytical uncertainty is based on historical QC data that is control charted and used to evaluate method accuracy and precision. The method uncertainty is calculated following ETS-12-012.2. The standard deviation is calculated for the set of accuracy results (in %) obtained for the QC samples. The expanded uncertainty is calculated by multiplying the standard deviation by a factor of 2, which corresponds to a confidence level of 95%. Table 8. Analytical Method Uncertainty. Analyte PFOA PFBS PFHS PFOS PFOA PFBS PFHS PFOS Calibration Method External Standard External Standard External Standard External Standard Internal Standard Internal Standard Internal Standard Internal Standard Standard Deviation (%) 8.37 8.78 7.69 10.4 7.68 7.99 9.94 8.42 Method Uncertainty 17% 18% 15% 21% 15% 16% 20% 17% 3.8 Field Matrix Spikes (FMS) A field matrix spike was collected at each sampling point to verify that the analytical method is applicable to the collected matrix. Field matrix spikes are generated by adding a measured volume of field sample to a container spiked by the laboratory with the target analytes prior to shipping sample containers for sample collection. Field matrix spike recoveries within method acceptance criteria of 10030% confirm that "unknown" components in the sample matrix do not significantly interfere with the extraction and analysis of the analytes of interest. The standards used for the preparation of the field matrix spiking solutions contained reference materials comprised of both linear and branched isomers for PFOA and PFOS. Field matrix spikes are presented in section 4 of this report. FMS Recovery - (Sample Concentration of FMS - Average Concentration: Field Sample & Field Sample Dup.) * 1 0 0 % Spike Concentraton Table 9. Field Matrix Spike Concentrations. Location ACI ACM2 ACE WW8R, WW9R, WW10R, WW11R Trip Blank Description Field Matrix Spike Field Matrix Spike Field Matrix Spike Field Matrix Spike Low Field Matrix Spike High Field Matrix Spike Firial Concentr.tion (ng/mL PFOA PFBS PFHS PFOS 2480 4.96 4.96 2500 5.00 5.00 2510 5.00 5.00 2500 4.99 4.99 2480 2500 2510 2500 4.96 2480 5.00 2500 5.00 2510 4.99 2500 PAGE 11 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 4 Data Summary and Discussion The tables below summarize the sample results and field matrix spike recoveries for the seven locations as well as the Trip Blank. Each table provides the average concentration and the relative percent difference (%RPD) of the sample and sample duplicate. Results and average values are rounded to three significant figures. Relative percent difference (%RPD) values are rounded to two significant figures. Because of rounding, values may vary slightly from those listed in the raw data. Field matrix spikes meeting the method acceptance criteria of 30%, demonstrate that the method is appropriate for the given matrix. All field matrix spike samples and surrogate recovery standards met method acceptance criteria except where noted below. DAL-GW-ACM2; the FMS sample (5 ng/mL) was not appropriate for PFBS; however, the surrogate recovery standard 13C4-PFOS met method acceptance criteria. No additional QC samples were prepared. PAGE 12 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 10. DAL GW ACI 131118 (1) 3M LIMS ID Description ISO13-07-10-001 DAL-GW-ACI-0-131118 ISO13-07-10-002 DAL-GW-ACI-DB-131118 ISO13-07-10-003 DAL-GW-ACI-FMS-131118 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 2190 NA 2190 NA 4670 100 2190 ng/mL 0.0% Concentration (ng/mL) %Recovery 1100 NA 1090 NA 3440 93.6 1100 ng/mL 0.91% 3M LIMS ID Description ISO13-07-10-001 DAL-GW-ACI-0-131118 ISO13-07-10-002 DAL-GW-ACI-DB-131118 ISO13-07-10-003 DAL-GW-ACI-FMS-131118 Average Concentration (ng/mL) %RPD PFHS PFOS Concentration (ng/mL) %Recovery 1320 NA 1340 NA 3840 100 1330 ng/mL 1.5% Concentration (ng/mL) %Recovery 2260 NA 2220 NA 4700 98.4 2240 ng/mL 1.8% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-10-001 DAL-GW-ACI-0-131118 ISO13-07-10-002 DAL-GW-ACI-DB-131118 ISO13-07-10-003 DAL-GW-ACI-FMS-131118 Average Concentration (ng/mL) %RSD %Recovery 107 107 111 108% 2.1% %Recovery 108 109 112 110% 1.9% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 13 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 11. DAL GW ACM2 131118 3M LIMS ID Description ISO13-07-10-004 DAL-GW-ACM2-0-131118 ISO13-07-10-005 DAL-GW-ACM2-DB-131118 ISO13-07-10-006 DAL-GW-ACM2-FMS-131118 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-10-004 DAL-GW-ACM2-0-131118 ISO13-07-10-005 DAL-GW-ACM2-DB-131118 ISO13-07-10-006 DAL-GW-ACM2-FMS-131118 Average Concentration (ng/mL) %RPD PFOA (1) PFBS (2) Concentration (ng/mL) %Recovery 0.0539 NA 0.0527 NA 4.88 97.3 0.0533 ng/mL 2.3% Concentration (ng/mL) %Recovery 1130 NA 1110 NA 1120 NC 1120 ng/mL 1.8% PFHS (1) PFOS (1) Concentration (ng/mL) %Recovery 0.0728 NA 0.0670 NA 5.30 105 0.0699 ng/mL 8.3% Concentration (ng/mL) %Recovery 0.206 NA 0.198 NA 5.41 104 0.202 ng/mL 4.0% 13C4-PFOA (1) 13C4-PFOS (1) 3M LIMS ID Description ISO13-07-10-004 DAL-GW-ACM2-0-131118 ISO13-07-10-005 DAL-GW-ACM2-DB-131118 ISO13-07-10-006 DAL-GW-ACM2-FMS-131118 Average Concentration (ng/mL) %RSD %Recovery 105 110 105 107% 2.7% %Recovery 106 108 106 107% 1.1% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration. (1) Samples were analyzed by internal standard calibration. (2) Samples were analyzed by external standard calibration. PAGE 14 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 12. DAL GW ACE 131118 (1) 3M LIMS ID Description ISO13-07-10-007 DAL-GW-ACE-0-131118 ISO13-07-10-008 DAL-GW-ACE-DB-131118 ISO13-07-10-009 DAL-GW-ACE-FMS-131118 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-10-007 DAL-GW-ACE-0-131118 ISO13-07-10-008 DAL-GW-ACE-DB-131118 ISO13-07-10-009 DAL-GW-ACE-FMS-131118 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 0.511 NA 0.445 NA 5.37 98.6 0.478 ng/mL 14% Concentration (ng/mL) %Recovery 0.620 NA 0.563 NA 5.56 99.4 0.592 ng/mL 9.6% PFHS PFOS Concentration (ng/mL) %Recovery 0.401 NA 0.331 NA 5.58 104 0.366 ng/mL 19% Concentration (ng/mL) %Recovery 0.0979 NA 0.0472 NA 5.13 101 0.0726 ng/mL 70% (2) 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-10-007 DAL-GW-ACE-0-131118 ISO13-07-10-008 DAL-GW-ACE-DB-131118 ISO13-07-10-009 DAL-GW-ACE-FMS-131118 Average Concentration (ng/mL) %RSD %Recovery 106 105 109 107% 1.9% %Recovery 104 105 106 105% 0.95% NA = Not Applicable (1) Samples were analyzed by internal standard calibration. (2) Sample/sample duplicate RPD did not meet acceptance criteria of <20%. PAGE 15 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 13. DAL GW WW8R 131118 (1) 3M LIMS ID Description ISO13-07-10-010 DAL-GW-WW8R-0-131118 ISO13-07-10-011 DAL-GW-WW8R-DB-131118 ISO13-07-10-012 DAL-GW-WW8R-FMS-131118 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-10-010 DAL-GW-WW8R-0-131118 ISO13-07-10-011 DAL-GW-WW8R-DB-131118 ISO13-07-10-012 DAL-GW-WW8R-FMS-131118 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 3060 NA 3010 NA 5130 84.3 3040 ng/mL 1.6% Concentration (ng/mL) %Recovery 363 NA 360 NA 2790 97.1 362 ng/mL 0.83% PFHS PFOS Concentration (ng/mL) %Recovery 1440 NA 1440 NA 3960 100 1440 ng/mL 0.0% Concentration (ng/mL) %Recovery 4790 NA 4710 NA 7360 104 4750 ng/mL 1.7% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-10-010 DAL-GW-WW8R-0-131118 ISO13-07-10-011 DAL-GW-WW8R-DB-131118 ISO13-07-10-012 DAL-GW-WW8R-FMS-131118 Average Concentration (ng/mL) %RSD %Recovery 101 96.6 97.3 98.3% 2.4% %Recovery 111 109 109 110% 1.0% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 16 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 14. DAL GW WW9R 131118 (1) 3M LIMS ID Description ISO13-07-10-013 DAL-GW-WW9R-0-131118 ISO13-07-10-014 DAL-GW-WW9R-DB-131118 ISO13-07-10-015 DAL-GW-WW9R-FMS-131118 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-10-013 DAL-GW-WW9R-0-131118 ISO13-07-10-014 DAL-GW-WW9R-DB-131118 ISO13-07-10-015 DAL-GW-WW9R-FMS-131118 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 2910 NA 2980 NA 5050 84.7 2950 ng/mL 2.4% Concentration (ng/mL) %Recovery 301 NA 309 NA 2750 97.8 305 ng/mL 2.6% PFHS PFOS Concentration (ng/mL) %Recovery 1300 NA 1370 NA 3940 104 1340 ng/mL 5.2% Concentration (ng/mL) %Recovery 4430 NA 4640 NA 7240 108 4540 ng/mL 4.6% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-10-013 DAL-GW-WW9R-0-131118 ISO13-07-10-014 DAL-GW-WW9R-DB-131118 ISO13-07-10-015 DAL-GW-WW9R-FMS-131118 Average Concentration (ng/mL) %RSD %Recovery 98.4 98.7 93.8 97.0% 2.8% %Recovery 110 112 107 110% 2.3% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 17 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 15. DAL GW WW10R 131118 (1) 3M LIMS ID Description ISO13-07-10-016 DAL-GW-WW10R-0-131118 ISO13-07-10-017 DAL-GW-WW10R-DB-131118 ISO13-07-10-018 DAL-GW-WW10R-FMS-131118 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-10-016 DAL-GW-WW10R-0-131118 ISO13-07-10-017 DAL-GW-WW10R-DB-131118 ISO13-07-10-018 DAL-GW-WW10R-FMS-131118 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 2410 NA 2380 NA 4530 85.9 2400 ng/mL 1.3% Concentration (ng/mL) %Recovery 301 NA 304 NA 2790 99.5 303 ng/mL 0.99% PFHS PFOS Concentration (ng/mL) %Recovery 1120 NA 1120 NA 3690 102 1120 ng/mL 0.0% Concentration (ng/mL) %Recovery 3940 NA 3840 NA 6390 100 3890 ng/mL 2.6% 13C4-PFOA 13C4-PFOS 3M LIMS ID Description ISO13-07-10-016 DAL-GW-WW10R-0-131118 ISO13-07-10-017 DAL-GW-WW10R-DB-131118 ISO13-07-10-018 DAL-GW-WW10R-FMS-131118 Average Concentration (ng/mL) %RSD %Recovery 100 97.0 93.5 96.8% 3.4% %Recovery 111 110 108 110% 1.4% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 18 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 16. DAL GW WW11R 131118 (1) 3M LIMS ID Description ISO13-07-10-019 DAL-GW-WW11R-0-131118 ISO13-07-10-020 DAL-GW-WW11R-DB-131118 ISO13-07-10-021 DAL-GW-WW11R-FMS-131118 Average Concentration (ng/mL) %RPD 3M LIMS ID Description ISO13-07-10-019 DAL-GW-WW11 R-0-131118 ISO13-07-10-020 DAL-GW-WW11 R-DB-131118 ISO13-07-10-021 DAL-GW-WW11 R-FMS-131118 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 1300 NA 1330 NA 3620 92.7 1320 ng/mL 2.3% Concentration (ng/mL) %Recovery 286 NA 288 NA 2810 101 287 ng/mL 0.70% PFHS PFOS Concentration (ng/mL) %Recovery 673 NA 687 NA 3220 101 680 ng/mL 2.1% Concentration (ng/mL) %Recovery 1790 NA 1900 NA 4480 105 1850 ng/mL 5.9% 13c 4-p f o a 13c 4-p f o s 3M LIMS ID Description ISO13-07-10-019 DAL-GW-WW11 R-0-131118 ISO13-07-10-020 DAL-GW-WW11 R-DB-131118 ISO13-07-10-021 DAL-GW-WW11 R-FMS-131118 Average Concentration (ng/mL) %RSD %Recovery 100 101 98.1 99.7% 1.5% %Recovery 110 113 109 111% 1.9% NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 19 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Table 17. Trip Blank Results 3M LIMS ID ISO13-07-10-022 ISO13-07-10-023 ISO13-07-10-024 Description DAL-GW-TRI P-0-131118 DAL-GW-TRIP-LS-131118 DAL-GW-TRIP-HS-131118 3M LIMS ID ISO13-07-10-022 ISO13-07-10-023 ISO13-07-10-024 Description DAL-GW-TRI P-0-131118 DAL-GW-TRI P-LS-131118 DAL-GW-TRIP-HS-131118 PFOA PFBS Concentration (ng/mL) <0.0240 (1) 5.17 (2) 2710 (2) %Recovery NA 104 109 Concentration (ng/mL) <0.0250 (1) 5.13 (2) 2490 (2) %Recovery NA 103 99.6 PFHS PFOS Concentration (ng/mL) <0.0400 (1) 4.84 (2) 2530 (2) %Recovery NA 96.8 101 Concentration (ng/mL) <0.0232 (1) 4.98 (2) 2650 (2) %Recovery NA 99.8 106 13C4-PFOA 13C4-PFOS 3M LIMS ID ISO13-07-10-022 ISO13-07-10-023 ISO13-07-10-024 Description DAL-GW-TRI P-0-131118 DAL-GW-TRI P-LS-131118 DAL-GW-TRIP-HS-131118 %Recovery 107 (1) 116 (2) 114 (2) %Recovery 106 (1) 115 (2) 113 (2) NA = Not Applicable (1) Samples were analyzed by internal standard calibration. (2) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were added to the samples during sample preparation. PAGE 20 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. IS013-07-10 5 Conclusion Laboratory control spikes were used to determine the analytical method accuracy and precision for all analytes. The accuracy and precision were then used to estimate the method uncertainty for the results. Field matrix spike recoveries demonstrated that the analytical method was appropriate for the given sample matrix. Analysis was completed using 3M Environmental Laboratory Method ETS-8044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Analytical results are reported in Table 1 and 10-17 of this report. 6 Data / Sample Retention All remaining sample and associated project data (hardcopy and electronic) will be archived according to 3M Environmental Laboratory standard operating procedures. . 7 Attachments Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System. 8 Signatures Susan T. Wolf, 3M(Ppincipal Analytical Investigator Date 6> William K. Reagen, Ph.D., 3M Environmental Laboratory Technical Director Date The 3M Environmental Laboratory's Quality Assurance Unit has audited the data and report for this project. Quality A s s ig n e e Representative Ihl M Date This test report shall not be reproduced except in full, without written approval of the 3M Environmental Laboratory. PAGE 21 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System ACI (Activated Carbon Influent) - Sample Results in ng/mL ACI 1/17/2013 2/13/2013 3/27/2013 4/29/2013 5/31/2013 6/27/2013 7/23/2013 9/30/2013 10/28/2013 11/18/2013 PFOA 1910 2300 2220 1480 1860 1480 1630 2320 1880 2190 PFBS 588 830 1060 1360 1040 708 1230 356 1590 1100 PFHS 895 1580 1090 777 940 942 749 1400 866 1330 PFOS 1810 2940 2490 1670 2150 1590 1680 3240 2100 2240 ACE (Activated Carbon Effluent) - Sample Results in ng/mL ACE 1/17/2013 2/13/2013 3/27/2013 4/29/2013 5/31/2013 6/27/2013 7/23/2013 9/30/2013 10/28/2013 11/18/2013 PFOA <0.0240 0.124 0.0380 0.0422 0.0725 0.0717 0.0643 0.115 0.231 0.478 PFBS <0.0250 0.0360 <0.0250 0.392 24.8 111 1960 1950 0.379 0.592 PFHS <0.0250 0.178 0.0477 0.057 0.105 0.118 0.0778 0.156 0.180 0.366 PFOS <0.0232 0.0329 <0.0232 <0.0232 <0.0232 <0.0232 0.0277 0.0452 0.0785 0.0726 PAGE 22 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW8R - Sample Results in ng/mL WW8R PFOA PFBS PFHS PFOS 1/17/2013 4350 410 1930 5710 2/13/2013 3250 354 1900 4850 3/27/2013 3640 385 1760 5120 4/29/2013 3190 364 1610 4830 5/31/2013 2760 289 1330 4180 6/27/2013 2760 282 1340 4110 7/23/2013 2640 263 1260 3910 9/30/2013 2890 303 1370 4100 10/28/2013 2830 312 1300 4410 110/18/2013 3040 362 1440 4750 WW9R - Sample Results in ng/mL 5000- FC C harting fo r DAL_W W 9R P F O A -------- --------PFOS------- -------- P F B S -------- --------- P FH S -------- WW9R PFOA PFBS PFHS PFOS 1/17/2013 2710 184 954 3690 2/13/2013 2850 236 1400 4100 3/27/2013 3330 278 1440 4660 4/29/2013 2650 244 1200 4340 5/31/2013 2660 226 1120 4210 6/27/2013 2630 225 1140 4150 7/23/2013 2410 212 1030 3670 9/30/2013 2730 249 1220 4200 10/28/2013 2820 286 1280 4380 11/18/2013 2950 305 1340 4540 PAGE 23 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO13-07-10 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW10R - Sample Results in ng/mL WW10R PFOA PFBS PFHS PFOS 9/30/2013 2070 247 1030 2770 10/28/2013 2150 264 1030 3160 11/18/2013 2400 303 1120 3890 WW11R - Sample Results in ng/mL WW11R PFOA PFBS PFHS PFOS 9/30/2013 1720 299 1000 2200 10/28/2013 1100 240 511 1670 11/18/2013 1320 287 680 1850 PAGE 24 OF 24