Document ev637RqQo3br3GomvKLbmv329

Page 1573 1 MR. IGNATOWSKI: I don't think yours 2 works -- oh, yes, it does. 3 November 15, 1971, Ford Number 97. 4 THE COURT: It will be admitted in 5 evidence. 6 (Whereupon, Plaintiffs' Exhibit Number Ford 7 97 was received into evidence.) 8 MR. IGNATOWSKI: Since our last study 9 conducted in August 1970, the air collection equipment 10 has been exhausted to the outside of the plant. 11 I am going to move down to the third 12 paragraph. 13 The results of the air samples taken in the 14 mixing room indicate a continuing dust problem. 15 Little change can be noted in the operation of this 16 area. 17 For example, automatic silos for asbestos 18 are not reliable, necessitating the adding of asbestos 19 by hand. Also, silo ductwork leaks asbestos fibers 20 and compressed air is used for cleaning purposes. 21 It should be noted that the Occupational