GRACE Construction Products Division W.R. Grace & Co. 62 Whittemore Avenue Cambridge, Mass. 02140 (6171 876-1400 April 6, 1987 Mr. Hans D. Rudolph Technical Standards and Services Manager Real Estate/General Services Division Xerox Corporation P. 0. Box 1600 Stamford, CT 06904 Dear Mr. Rudolph: Thank you for the opportunity for Dennis Boylan and me to meet with you last Friday on the Xerox Center Project in Santa Ana and discuss the issues raised concerning M0N0K0TE fireproofing. M0N0K0TE-4 and -5 should be considered asbestos free. When tested accord ing to the United States Environmental Protection Agency (EPA) Interim Method for the Determination of Asbestos in Bulk Insulation Samples, no asbestos has been found in Monokote. One of the components of M0N0K0TE-4 and -5 is vermiculite, a naturallyoccuring mineral that may contain tremolite in the ore body. Except for minute amounts, the tremolite is removed from the vermiculite during processing. It is this purified vermiculite which is used in the manufacture of all of Grace's vermiculite-containing products, including M0N0K0TE-4 and -5. Using sophisticated, state-of-the-art electron microscopy analysis, it may be possible to detect fibrous tremolite in MONOKOTE at levels below .0017. (10 parts per million) by weight. Concerning this, I left with you copies of independent laboratory test results by Arthur D. Little, Inc. and Mt. Sinai Medical Center. These extremely low levels are characterized by experts as "totally insignificant". The EPA and some individual states such as California and New Jersey, have stringent standards covering the spray-application of fireproofing materials. With levels below .0017. (10 parts per million), MONOKOTE is more than 1000 times below the EPA standard, and more than 250 times below the more stringent state requirements. The United States Occupational Safety and Health Administration (OSHA) regulates occupational exposure to airborne asbestos fiber and has recently established a Permissible Exposure Level (PEL) of 0.2 fibers/cc (8 hr. time weighted average) and an action level of 0.1 fibers/cc. Grace frequently monitors jobsite exposure levels for workers applying MONOKOTE and all tests performed show exposure levels substantially below the OSHA action level and, in fact, below levels which can be quantified with statistical reliability. 1516992 2- - OSHA has further officially informed Grace that its asbestos regulations are not meant to be enforced for any products which contain de minimus levels of naturally-occuring tremolite where exposure levels to employees can be demonstrated to not exceed the OSHA action level. I gave you copies of this OSHA letter. As you requested, I also enclose Grace's MSDS for MONOKOTE 4 and 5. I trust that our meeting and the information provided in this letter will enable you to use GRACE products with the same confidence in their safety and performance as you have in the past. If there is anything further we may do, please do not hesitate to call. Yrtiiwe 1/ RHL/acd Enc. Robert H. Locke Marketing Director 15169926 f - Page 1^ of 4^ MATERIAL SAFETY DATA SHEET W. R. Grace & Co. 62 Whittemare Ave. Cambridge, MA 02140 r ' MSDS Number: Z-8303 Cancels: Z-144-2 Date Prepared: 9/24/86 Telephone Number for Information and Emergency Response (617) 876-1400 X-3140 or 3897 SECTION I - PRODUCT IDENTIFICATION Trade Names and Synonyms: MCNOKDTE; MK-4, MK-5 Chenical Name and Family: Lightweight. Gypsun-Vezmiculite Plaster Formula: Blend of Gypsum Verraiculite, Cellulose and (in MK-5 only) Fiber Glass CAS#: Not Applicable (mixture) DOT Hazard CLass/ID#/Label: Not Applicable Reportable Quantity (RQ): Not Applicable Surface Freight Classification: Nail Plaster NPCA-miS Hazard Index: e Health: 1* e Flammability: 0 e Reactivity: 0 e Personal Protection: E SECTION II- HAZARDOUS INGREDIENTS/IDENTITY INFORMATION (CASt, Chemical & Ingredient Cannon Names) Percent by Weight Exposure Limits 0SHA AOGIH Total Dust (Gypsum may add vp to 2% Quartz CAS# 14808-60-7) PEL 30Mq/M3 TLV 30Mq/M3 Not Applicable % Quartz + 2 % Quartz + 3 Respirable Dust (Gypsum may add up to 2% Quartz CAS# 14808-60-7) PEL = 10Mq/M3 TLV = 10Mq/M3 % Quartz + 2 % Quartz + 2 Stld'ION III - PHYSICAL/OffMirAr. f'waparTFR tqttpc; Boiling Point Not Applicable Specific Gravity (H?Q = 1) Vapor Pressure (mn Hq.) None % Volatiles None 12-15 PCF (Dry Bulk Density) 2.2669151 Vapor Density (AIR = 1) Not Applicable Evaporation Rate (Butyl Acetate = 1) Not Applicable Solubility in Water SIight pH Approximately neutral, variable with water source IZ-8303 SECTION IV - FIRE AND EXPLOSION HAZARD DATA Flash Point (Method Used) N. A. Flanroable Limits None Extinguishing Media Not Applicable Special Fire Fighting Procedures None ^ Page 2 of 4 LEL UEL Unusual Fire and Explosion Hazards None Known SECTION V - REACTIVITY DATA Stable: Yes Conditions to Avoid: Not Applicable Inccropatability (Materials to Avoid): Prior to welding or cutting, MONOHDTE must be removed from steel surfaces in those immediate areas where direct exposure to excessive heat frcm the cutting or welding equipment is possible. Hazardous Decomposition or Byproducts: Sulfur Dioxide SO2 (Due to excessive heat frcm cutting or welding) Hazardous Polymerization: Will not occur conditions to Avoid: Not Applicable SECTION VI - HEALTH HAZARD DATA ' " -------------------- (Include all known acute and chronic effects, signs, and symptoms of exposure and medical conditions generally aggravated by exposure) Routes of Exposure: . Inhalation: Exposure to excessive airborne dust may cause coughing or sneezing. Long term exposure to Quartz Dust, which may be present up to 2%, can cause risk of silicosis, pneumoconiosis, dyspnea and decreased lung function. Skin and Eye: Eye contact with dust may cause minor mechanical irritation. Direct eye contact with MONOK3TE Spray may cause physical injury. Prolonged or repeated skin contact may dry skin. Ingestion: Not expected to be harmful. Carcinogenicity According to NTP, IARC and OSHA: Not Applicable. Bhergency and First Aid Procedures: In case of contact, immediately flush eyes with plenty of water. Do not rub eyes. Consult a physician. If inhaled get fresh air. If symptoms persist consult a physician. 15169928 fZ-8303 Page 3 of 4 SECTION VII - PRBOUJriCHS FOR SAFE HANDLING AND USE Warning Statements: CAUTION! Contains Vemiculite CAS# 1318-00-9, Gypsum CA|# 7778-18-9 and up to 2% Quartz CASI 14808-60-7. May be harmful if inhaled. Long-term overexposure to airborne dust may cause silicosis or other lung disease, ffey cause minor mechanical irritation to eyes. Direct contact with spray can damage eyes. Floors in spray area may be slippery when wet. Precautionary Measures; Avoid creating dust. Equip mixers with dust covers. Provide ventilation and respiratory protection. Wear eye protection to avoid contact with dust or spray. Post "slippery when wet" signs where appropriate. Steps to be Taken in Case Material is Released or Spilled; Cbserve precautions noted above. Remove material for disposal. Waste Disposal Method: MGNOHOTE waste is not defined as hazardous according to EEA (40 CFR 261.3). Dispose of all waste in accordance with applicable federal, state and local regulations. SECTION VIII - CONTROL MEASURES Respiratory Protection (Specify Type): Wear an approved dust mask (NIOSH TC-21C-XXX) to prevent exposure above the limits specified above in Section II. Ventilation bocal Exhaust? Mechanical: Exhaust fans may be necessary when mixing in enclosed areas. fecial: Not Applicable. Other: Not Applicable. Protective Gloves: Work gloves or hand creams may prevent drying skin. Eye Protection: Goggles are recommended viiere exposure to excessive dust or MONOKDTE spray is likely. Other Protective Clothing or Equipment: Normal work clothes. Work/Hygenic Practices: Use bag opening and disposal procedures vdiich minimize dust release. Equip mixers with dust covers as referenced in the MONOKDTE Equipment Bulletin. 15169929 IZ-8303 Page 4 of 4 SUPPLEMENTAL INFORMATION One of the components of this product is vermiculite, a naturally-occurring mineral that contains tremolite in the ore body^ 'Except for trace amounts, the tremolite is removed frcm the vermiculite during processing. It is this purified vermiculite which is used in the manufacture of MONOKOTE; MK-4 and MK-5. The EPA has stringent standards covering the spray-application of fireproofing materials. With levels below .001% (10 parts per million), MONOKOTE is more than 1000 times below the current EPA standard. MONONOTE 4 and 5 are in full compliance with all current and proposed Federal regulations and standards, including the proposed EPA ban and phase-out of products containing commercially-added asbestos. Using sophisticated, state-of-the-art electron microscopy analysis, it may be possible to detect fibrous tremolite in MONOKOTE at levels of .001% (10 parts per million) by weight or less. Copies of such independent laboratory test results by Arthur D. Little, Inc. and Mt. Sinai Medical Center are available upon request. On June 20, 1986 the United States Occupational Safety and Health Administration (OSHA) established new stringent regulations regarding occupational exposure to airborne asbestos fibers including tremolite. OSHA regulations include a maximum Permissible Exposure Level (PEL) of 0.2 fibers/cc (8 hr. time weighted average) and an action level of 0.1 fibers/cc. Grace frequently monitors jobsite exposure levels for workers applying MONORDTE; MK-4 and MK-5. All tests have shown exposure levels consistently below the OSHA action level. OSHA has officially informed Grace that its asbestos regulations are not meant to be enforced for any products which contain "de minimus levels" of naturally-occurring tremolite where exposure levels to employees do not exceed the OSHA action level. "THE DATA INCLUDED HEREIN ARE PRESENTED ACCORDING TO W. R. GRACE & OO. 'S PRACTICES CURRENT AT THE TIME OF PREPARATION HEREOF, ARE MADE AVAILABLE SOLELY FOR THE CONSIDERATION, INVESTIGATION AND VERIFICATION OF TOE ORIGINAL RECIPIENTS HEREOF AND DO NOT CONSTITUTE A REPRESENTATION OR WARRANTY FOR WHICH GRACE ASSUMES LECAL RESPONSIBILITY. IT IS THE RESPONSIBILITY OF A RECIPIENT OF THIS DATA TO REMAIN CURRENTLY INFOEMED ON CHEMICAL HAZARD INFORMATION, TO DESIGN AND UPDATE ITS OWN PROGRAM AND TO CCMPLY WITH ALL NATIONAL, FEDERAL, STATE, AND LOCAL LAWS AND REGULATIONS APPLICABLE TO SAFETY, OCCUPATIONAL HEALTH, RIGHT-TO-KNOW AND ENVIRONMENTAL PROTECTION."