Document emobY3g76XbLNG76v1adQVjMg
FROM. (NAME a location!
D. Ramsey - Anniston Plant
DATE SUBJECT REFERENCE
September 4, 1970
AROCLOR LOSSES TO THE ATMOSPHERE AT THE HC1 SCRUBBER JET
TO.
E. G. Wright
J. T. Bell V. R. Haupt J. C. Landwehr
Operations show that HCl gas not converted to Muriatic Acid is by-passed
to the scrubbing jets and sewered. Based on acid produced, sold, and
by-passed for the months of April, May, and June, an average day resulted
in 4500 #/hr. of HCl off-gas. Calculations based on vapor pressures, the
temperatures that the HCl comes in contact with, and the ppm of Aroclor
in acid - yields the following results:
0.6 lb./hr. or 14.4 lb./day of PCB in vapor form reaches the jets 2.1 lb./hr. or 50.5 lb./day of PCB in acid produced
Total = 64.9 lb./day of PCB passes the HCl knockout tank
Assuming 100% contact at the jets, 0.47 lb./hr. or 11.8#/day of PCB is sewered with the remaining 0.11 lb./hr. or 2.6 lb./day being lost to the atmosphere. Poor efficiency at the jets increases the loss of PCB to the atmosphere considerably.
:kd Attachment
F. D. Ramsey
DSW 376550
STLCOPCB4099074