Document emkZJrB0XYmoDVdLbNRZrX5Qe
Stieefeiy
nw Utfro-hydronic cast iron boilers -- completely packaged for fast installation
For the ultimate in modem alactric heating, choose the
aged, with cast iron boiler shell, electric heating ele
new Electra boilers! They provide the superior comfort.. ments. circulator and expansion tank inside the jacket.
and convenience of a hydronic heating system, while' All wiring has been completed and controls are mounted
using clean, flameless electricity as a fuel. Designed for
in pface. Piping connections are made fast and easy-
forced water applications in new homes or old, these__ __jyith only two simple electrical connections needed, to
electric boilers have outputs ranging from 34,000 to
main power supply and room thermostat.
82,000 Btuh. Their lightweight and extra-compact design make them ideal for wall-mounting, thereby freeing val- ' " uable floor space for other uses.
Electra (model EP) boilers come In four models, all the same In jacket and casting size, regardless of the num ber of heating elements installed. Each include those
New Electra boilers are fast and low-cost to install, with- ~ important features homeowners need for dependable,
out requiring any new steps of the hydronics contractor - - trouble-free electro-hydronlc heating-iugged-COnstruc-
that haven't been done before! They are completely peck- " ~ tion, simplified design and sensitive limit controls.
1--automatic air vent-bleeds off trapped air from the
boiler casting are low density for extra quiet performance.
system water.
1 2 3 I4-5 saquencing relay switch-provides for an incremental
2--adjustable limit control-allows selection of maxi
loading on the electric service line. This reduces line-
mum boiler water temperature for system design.
vsltage fluctuation and prevents power surge during
3--water pressure relief valve-is safely remote from all electrical connections.
4--pre-set pressure contra Is-guarantee safe operation within prescribed pressure range.
5--rad indicator lights-on jacket front visually indicate operation of heating elements.
S--circulatcr-is wired for continuous operation.
.
energizing.
3-cast Iron boiler shall-features an internal water flow baffle for quiet, efficient operation.
10-faetery-tnstalled expansion tank-is concealed inside jacket. II--two-tone jaeket-of beige and brown has doors on each side for easy access to controls and elements.
12-drain valvc-with flat wheel handle allows connec
7--electric heating alaments-mounted inside ends of
tion of standard hose Fittings.
comment isos amcaican stanoaao inc.
Electro (model EP) ratings*
bailer
It*, tf
number element*
wetu
witer
lt. < capacity ef
tub
amps Internal
caetini
240 velts fueee
(salient)
EP-34 EP-51 EP-M EP-82
2 -3
4 5
10,000 15,000 20,000 24,000
34,130 51,135 68.260 81.912
41.7 62.4 3.2 100.0
4
6' a
.10
US US US US
Tnle Boiler I* Initnou for ui on HO volt *-c <nsminl) thrao-win. ingl<ph*i. M-cyde service only. Internal wiring Uku 1 volU from (Dig teurca to eparata uit circulator and tnntlennar.
Electra
packaged electric boilers
| crated shipping weight'}.
............
appro*.'Vt,"-*
" shipping
boiler ' . ' weight v.V?..
number
. ' (peunde)
-IP-34 EP-51 EP-68 EP-82
. * MM .;* / -90 v;.'
91V4 1 93
dimensions and tappings (inches)
controls
Special temperature end pressure controls keep Electra boilers operating within e safe range at ail times. These controls are: 1 --An adjustable immersion limit that allows installer to set maximum water temperature for system design. It shuts off the boiler if temperature exceeds his pre-determined setting. 2-A pre-set high pressure switch that de-energizes the boiler
if the pressure ruches 28 psi. This switch is reinforced by the relief valve, which is pre-set to relieve at 30 psi.
3-A pre-set safe-fill switch that keeps elements from being energized unless pressure in the system is 4 psi. .This prevents
any chance of heating dements burning out should an attempt J".: ;
be made to operate the boiler while dry.
tint* ax% *ic mu
nvui J*1 Brn
. tttttt_______ te 000 006 .
EP packaged electric boilers are designed and built to comply with the American Society of Mechanical Engineers* Code. They have been examined and listed by Underwriters* Labo ratories under their Label Service Procedure.
AMERICAN STANDARD
3 PIUM6INC 4 HEATINC DIVISION
cieuird
packaged electric boilers
AMERICAN STANDARD plumbinc & heating division
<0 WEST 40TH STREET NEW YORK, N.Y. 2001*
313-2
3) It '69: