Document emVq06XV9Y0Jw7X2gzgpzbjxG
n ^c'
Hearing Clerk Environmental Protection Agency Room 1019 - East Tower 401 M Street, S.W. Washington, D.C. 20460
Re: Environmental Protection Agency (40 CPR Part 129) Water Program Proposed Toxic Pollutant Effluent Standards Federal Register, Vol. 38, No. 247, Pages 35388-35395 Thursday, December 27, 1973 *
Gentlemen: On January 18, 1974, in accordance with Section 104.6, Part 104, Chapter I of Title 40, Code of Federal Regulations, we filed objections relating to the polychlorinated biphenyl effluent standards proposed in new Part 129, Subpart I, Chapter I of Title 40, Code of Federal Regulations.
As provided in "Order and Notice in the Matter of Proposed Toxic Pollutant Effluent Standards for AldrinDieldrin et al. - FWPCA (307) Docket No. l" dated February 8, 1974 by William J. Sweeney, Administra tive Law Judge, we offer the following comments des cribing our objections in greater detail.
Monsanto Company has been a maJor^n&nufacturer of chemical prbducte since 1901. These products are used ii^humerous American industries, antNin.-fact,
0046637
PCB-ARCH0743375
2 -
-
through our research department^-w^have played a^ role lr^developing^neiL-products to meet tK^"heeds of Industry and the consumer.
On ^ome occaslons^^chemlcal compound with specific
properties is developed to meet/a nb^3 in a certain
application. In othercases a chemicalVompoui'id wi^
I /
\
/
_
unique properties is de^^^lopfed first -- possibly
through Ihn6vative research, or even by happenstance --
and then an end-use is found.
The chemical structure of PCB^ias been known for nearly 100 years. It was not until the late 1920s that a use for PCB^was found -- as a dielectric fluid in transformers and capacitors. The properties of PCEi^-- inertness, fire resistance and a non-conductor of electricity -- fjgawf^^Kbe perfectly suited to
those electrical applications where high-voltage arcing could occur; possibly resulting in serious fires or damage to the equipment.
Morrg3&bo--began (commercial production of PCBHn 1929.
"
'
4
As the unique properties of the material became known,
new uses were found. For example, their fire-resistant
nature made them excellent choices for use in heat-
transfer fluids. Their inertness gave long-lasting
qualities to lubricants. Their use in surface coatings
improved waterproofing characteristics.
^
O0'*bbi&
PCB-ARCH0743376
- 3 -
Handling of the product at the manufacturing level
has not presented problems as long as the pninpr r
industrial hygiene practices were followed and PCB
has always been considered less hazardous than many
other chemicals in everyday use.
Therefore, it appeared that PCBs
a 4^L ery-^ulta^ea
product which met the needs of Industry.
Late in the 1960s, sophisticated analytical procedures
were developed which could detect very minute quantities
of PCB in nature. Following this analytical break-
j
'
`
;
J
through, researchers discovered that PCB could ppssib]y
.
!
j
be affecting certain fbrms of aquatic, marine, t/errestrial
and avian wildlife.
Thq pers stent nature and stability of PCB while so
\
.
|
desirably from the standpoint of many Industrie 1 appli-
appeared to be ^undesirable ini terms of our cations,
environment
CHRREflT JIS&S' 1
When questions about the effect of PCB^on the environ
ment first surfaced, Monsanto Company reviewed its
product line and the applications for these products. ft*
As more data were developed ,a@d the environment*!
opwhrnvT-r^y gr~vn Monsanto took steps
to
reduce the entry of PCB into the environment. The
0046639
PCB-ARCH0743377
-4 -
Company stopped the sale of PCB^for use in various
applications, except where no acceptable alternatives
were available. Today, PCB ^manufactured by Monsanto Company is^sold ^
VJ' 0-
is*.
"
^
to the electrical industry where it is used in closed1' systems as a dielectric fluid in transformers and capacitors -- applications for which we understand there continues--to--be no acceptable substitutes. C$rr$ptly
- 'S'- , >* , /v*
...
-M''
,-W>
approved by Monsanto
PCB sales.
Our manufacturing and sales reduction program was a unilateral, action taken by Monsanto and was based on our evaluation of developing environmental data.
The Interdepartmental Task Force on PCBs in its report (l), concurs that the safety benefits derived Justify the continued use in this application. Recommenda tion 6 under Findings, Conclusions and Recommendations reads as follows:
l/v
n ,s>
/ lis* 1
0
"6. The use of PCBs should not be banned entirely. Their continued use for transformers and capacitors in the near future is considered necessary because of the significantly increased risk of fire and explosion and the disruption of electrical
0046640
PCB-ARCH0743378
- 5 -
service which would result from a ban on PCB use. Also, continued use of PCBs in transformers and capacitors presents a minimal risk of environmental contamina tion. The Monsanto Company, the sole domes tic producer, has reported voluntarily eliminating its distribution of PCBs to all except manufacturers of electrical transformers and capacitors."
)f $ I-
DEFINITION OF POLYCHLORINATED BIPHENYLS
Commercial Ichlorinated
biphenyl
products.1,
0^ of
<7 l which
A
Aroclorf are examples, are produced by direct chlori
nation of biphenyl; the degree of chlorination being
chosen to provide desired properties. Thes~g~'ma tena 1 s
ciTernttrally restgtairt,"
ly
soluble in most common organlr snlMnfsJ -nnri hmm-
water solubilities nn the order nP 2S-P00 pph These
products are in all cases multi-component mixtures
and not single entities as implied by the commonly
employed acronyn^PCB
act, ^the^pemingrcial
ture^^an/theoretically hav^/'a^/^any'
:<
ents cprfc^rprng U=*i0 dhlorine atoms
/
ts
V
nt bipftefiyl
PCB-ARCH0743379
- 6 -
While it is well understood and accepted that owh
chlorinated biphenyl isomer has a unique set of physi
cal and chemical properties, it is apparently not understood that each -isomer aJ bioaccumulate^ ad
, k. 1
biodegradef at M different rate;?.
This lack of understanding is amp-ly reflected in the definition proposed in the EPA Toxic Pollutant Effluent Standards (Federal Register, Vol. 38, No. 247, page 35393, Section 129.09a) and we quote:
"As used in this Subpart, the term: Poly chlorinated biphenyls (PCB's) means materials containing the biphenyl group which have been chlorinated to varying degrees. There are 210 possible different PCB compounds."
We object to this definition because it implies that allfc$lorinated biphenyl isomers are of equal envlron-
mental concern, i.e., that they all persist and bio accumulate in the same manner in our environment. It has been well established by academic, government, and industrial researchers that this is simply not true. Environmental monitoring programs have clearly demonstrated that, with the exception of direct highlevel controllable release near points of manufac ture or use, the PCBs found in our environment are the more highly chlorinated ones, i.e., those
PCB-ARCH0743380
- 7 -
containing predominantly five or more chlorine atoms per biphenyl molecule (2-rl3).
This is true even though the lower chlorinated biphenyls have cons tltuteT^~65% of all the PCBs manufactured
over the years. This is strong evidence that the
^r
Less chlorinated
h
'
degrade rapidly. It further
, sttggesbs that even under conditions of anresb-ricted^'
use, and without special precautions to paaegsnt release
into our environment (which lsr tamafey not the case
now), that the^ee^chlorinated"mab-e*`4e-ls degrade
rapidly enough to present bioaccumulation.(
More recently, it has also been demonstrated in labora tory experiments that chlorinated biphenyl isomers, readily undergo bacterial degradation at rates depen dent upon the number of chlorines per biphenyl-mole cule (17* 18, 19* 20 and 21). There are also good indications that ambient environmental PCB levels are decreasing, at rates more rapidly than predicted (14, 15, 16).
The rapid metabolism of these chlorinated isomers
,
and their lack of importance as contributors to the
chlorinated biphenyl tissue burdens is evidence in
the results of numerous studies. Risebrough (2) re-
.
ported that the chlorine composition of the PCB de
tected in Atlantic Ocean zooplankton was approximately
QQHbb^
PCB-ARCH0743381
ui,4'
*1
,, * >
qX
'V as
5^#.^ He concluded^'lt might he expected therefore
that biphenyls with fewer chlorine atoms would pre
dominate in planktonic samples unless these compounds
were selectively degraded." Similar findings in fresh
water and marine fishes were reported by Zitko (3)
and Jensen, et al., (26). The disappearance of the
lower chlorinated homologs in extracts of tissues
from birds (5) and mammals (6) would -sdrst) Indicate
mafeo3Aa=l>reakdown of the lower chlorinated homologs.
ihlorobi^heriyl in/ra'F51rk3_J:r?ui"~^>fe^^
I<fe-has also'been suggested that hydroxyiation of
t-Ka-1
nlnlnnlna Vin.mr1 ngci 1g a general mpf.flhnl 1 o
pa^tayT^^sultlfig' ^Pe&fflp-lete degr^airhm^=l-b4rds and, mamma 1-&. As a result of thl^e^g^vely-^rap^d^
HR^=gg^3jebe-4egrra da t4an=o*f -th e chlorinated biphenyls
containing less than five chlorine atoms per molecule,
their contribution to the effluent should not be used
in measuring pplychlorinated biphenyl effluent from
a facility. 4/0
On the basis of these data
rfTTTMfn it. tn nr un
realistic to consider all/chlorinated biphenyls equivah
lent in terms of persistence and bioaccumulation as
does the proposed regulation. Itfe; therefore, stogfegst
tbftfe^-for environmental purposes, the definition of
tn. jJ'-
00M>6*^
L
PCB-ARCH0743382
- 9 -
PCBs focus upon those which are truly nf concern-
and we recommend that/ a^gre^aiHiLa^l^jiejrnition
***a*!id--fhrger-:r-- rt _ .,
PVa/_ jjsfuti'w-^^j
/ ,
.,, . ^ r- iU^
^'^',^!> >
^
"Polychlorinated biphenyls (PCBs) means materials containing the biphenyl group which is chlorinated and which have been shown to persist and rapidly bioaccumulate in the aquatic environment. These chlori nated biphenyls are identified as those components having gas chromatographic retention times greater than 60, relative to p,p-DDE = 100, under the standard con ditions recommended in the EPA PCB test method."
In sqgg^s-t^ng th: definitiprrk we want it/understood that we ire not /proposing' th^
/ f / / the/lower chlorinated biph
lat/thje data/indicates that he capability of pandl mounts were unknbwingl with the industrial restrict
critical /ion-d/spers/ve uses, cycle anjfl proper disposal> ha aspect \hndei/ control.
0046645
PCB-ARCH0743383
- 10 -
ANALYTICAL METHODOLOGY
We have no reason to doubt that the recomm<--
-)
PCB test method is capable of detecting ppt^Tevels
of PCBs in waste waters. However, our experience
with analyzing industrial waste waters for PCBs at
the ppt level prompts us to be concerned about the
following areas, some of which are not covered ade
quately in the test procedure.
1. Sampling Procedures
2. Correction for Laboratory and Reagent Background
3* Correction for Non-PCB Sample Inter ferences
4. Absolute Verification
5. Quantitation
6. Precision and Accuracy
Our concern lies in the fact that any method, especially one as complex as a PCB analytical method, which is to
iAilU ~tKl be used for effiorcemen-t purpo^sesmiust be thoroughly evaluated. If this is n<ou done, th^^n for cement /--and--
effectiveness of any effluent limit, no matter what the level, will prove to be difficult, if not impossible.
For example, we have found that if waste water streams are not sampled properly, the PCB levels found depend
00^6646 PCB-ARCH0743384
11
on the sampling procedure employed and bear no relation ship to the amount of PCBs discharged. For this reason, sampling procedures used must be designed for the dis charge in question and clearly stated. To our knowledge, this has not been done.
We also note that no provisions are recommended for correcting the apparent PCB level found in a sample for laboratory and reagent background. It is our experience that as one approaches the ppt level, this background can significantly affect the observed PCB level. .
With regard to correction for non-PCB sample inter ferences, we feel that, while the procedure notes many of the possible interferences, it does not really adress itself to those which are more likely to be in indus trial waste water streams. For this reason, if the electron capture chromatogram does not match the PCB being manufactured or used, complete absolute identifi cation of all components counted as PCB must be validated via
I'r % While the scheme proposed for estimation (quantitation) of PCBs is logical, it suffers from the same short coming as do the multitude of other procedures which have been proposed. It is an empirical estimate and
0046647
PCB-ARCH0743385
12
only a reflection of the real PCB level. Therefore, it should be determined via an alternate, more-elaborate procedure how closely the calculated PCB levels (for each of the cases) are to the real PCB levels so that they may be corrected.
Last, but not least, the precision and accuracy of any procedure proposed as a standard method should under go a thorough inter-laboratory evaluation. If this has not already been done, it must be carried out prior to the use of the procedure for enforcement purposes. The accuracy and precision of the Monsanto PCB pro cedure has been subjected to a preliminary evaluation. Prior to this evaluation, we probably would have over estimated the precision and accuracy of our procedure. The exact details of the evaluation are available. Briefly, samples were prepared by spiking distilled water with 500 ppb PCBs. Individual preparations include blanks (no PCBs), Aroclor 1242 only, Aroclor 1254 only, Aroclor 1260 only, all 50-50 two-component mixtures, and a 1/3, 1/3* 1/3 preparation containing all three components. Six samples of each mixture were prepared and analyzed by two analytical labora tories. Each result, expressed in ppb of the indi vidual Aroclor, was converted to percent of the total added. Analysis of variance was run on all data taken together and on each laboratory independently.
0046648
PCB-ARCH0743386
- 13 -
* The 95# confidence limits observed for
individual results were:
Either Lab
87.5 + 55.2#
Lab A
81.3 + 46.4#
Lab B
93.7 + 19.2#
The repeatability for the individual labs
based on repeat tests of samples having
identical prepared compositions was:
Lab A Lab B
+ 42.0#
+ 11.6#
We feel that these results demonstrate the importance of evaluating the precision of any PCB procedure. Note that the test did not include sampling problems, used distilled water free of interferences, and was carried out at a relatively high PCB leve^ (500,000 ppt) by two experienced laboratories. It is expected that, if sampling problems were Involved, and the level of PCB present was extremely low, the accuracy and precision of any PCB method would degrade considerably.
PROPOSED EFFLUENT STANDARD In the establishment of the proposed effluent standard the primary basis for toxicological consideration came from the Water Quality Criteria, October, 1973* (Federal Register, Vol. 38, pages 29646 et seq., Friday, October 26, 1973). These criteria were, in turn, based on Water
00466^9
PCB-ARCH0743387
- 14 -
Quality Criteria, 1972 by the National Academy of Sciences and the National Academy of Engineering.
The Water Quality Criteria, October 1973 have not undergone the normal review, criticism, comment and revision before final adoption. We object to the use of challengeable portions of a proposed publication in the development of critical effluent standards.
We note in Water Quality Criteria, 1972 in those sections pertaining to polychlorinated biphenyls, the frequent use of unpublished data and the disturbing use of qualifying phrases such as "...may adversely affect...", "...apparently related...", or "...the work...suggest..." In our opinion, none of the discussions present ade quate data to support establishment of responsible effluent standards for PCBs.
On page 5 of Water Quality Criteria, 1972, the Committee
emphasized the importance in understanding that there
is a distinction between criteria and standards and
that the words were not interchangeable nor or they
synonyms for words such as objectives or goals. The
report further states that it is necessary to establish
scientifically-based recommendations for each assignable
water use, implying availability of practical methods
of detecting and measuring which can be applied to
monitoring. Once these fundamentals are available;
o
political, social and economical factors enter into
6650
PCB-ARCH0743388
- 16 -
environments to properly design laboratory studies.
Results from such studies are not extrapolatable to /
the natural situations and any conclusions derived
from such studies must still be considered speculative.
In our considered opinion, fundamental scientifically-
Y`
<, '*" A 'A'"'1 . \rfI i
based data is lacking and the establishment of effluent standards for polychlorinated biphenyls cannot be
^ . 1-
made intelligently and responsibly.
+ v' .y . .V ^. 4
In the establishment of the PCB effluent standard for freshwater systems a bioaccumulation factor of 200,000 was selected. This factor has no extrapolatable relationship to either the residues of PCB in salmon eggs or to PCB residues of fresh water forage fish. The only published report of an accumulation factor of the magnitude selected was that for the hepatopancreas of the pink shrimp, Penaeus durarum, (27). Even though an accumulation of 204,000 in the hepatopancreas has occurred, a neady complete elimination of PCB from that tissue was achieved when the shrimp were placed in water free of added PCB. The equilibrium whole body accumulation plateau indicated an approxi mate accumulation factor of 22,000. These results are in agreement with those reported by Stallings and Mayer (30), and with the studies of Ryther (28),
0QAb*^
PCB-ARCH0743390
- 17 -
Oreichus et al (24) and Crump-Welsner, et al (22)
showing equilibrium biomagnification factors between,
water and fish ranging between 1000 and 75,000 and
would support the selection of a factor considerably
lower than the 200,000 which was applied. We suggest,
from a review of the available literature, that a factor of 20,000-3$j4}00 cgulr&^e
V A
Abritrary safety factors were applied to the tolerable
chronic limit to establish the so-called ''critical
chronic limit" which was then used to compute the
maximum allowable effluent. These safety factors were
proposed to account for a multitude of variables.
Including non-point sources, multiple discharges
and industrial growth. The safety factors proposed
were identical for 7 of the 9 materials for which
effluent standards were prepared. These safety factors,
resulting in approximately two-fold reductions, are
so small as to be of no beneficial toxicological con-
7
sequence.
' i)
In establishing the effluent standards, an attempt was made to distinguish between types of receiving waters by classifying them as streams, lakes and impoundments, estuaries and coastal waters. We do not believe this attempt to distinguish water bodies
0046633
PCB-ARCH0743391
- 18 -
Is by any measure adequate. Water bodies are universall known to be complex systems with no two systems alike. With a complex material such as polychlorinated bi phenyls, the determination of possible adverse effects in each water body becomes exceedingly difficult. The uniqueness of each water system must be considered
A key parameter used to further describe the water body is the flow rate which was limited to the probable low rate of stream flow occurring during a sevenconsecutive-day period once in ten years. We do not agree that is realistic or appropriate. In our opinion, adequate control can be achieved using average stream flow rates.
Further, the maximum flow rate that can be used in calculating the daily discharge permitted has been arbitrarily set at 10,000 cubic feet per second. This limit is based on a nondegradation philosophy which tolerates limited diffusion and on a desire to discourage industry from locating facilities on large main inland waters and coastlines. This limita tion deprives our society from the Judicious use of an important great natural resource. Discharge limi tations should be based on the adverse effects a material will have on a water system, not on its size
0Q46b5<*
PCB-ARCH0743392
- 19 -
or flow rate. For PCBs, proper control will not occur by Imposing maximum flow rate conditions, but by applying results from scientific studies which properly de fine how each water system responds to the presence of PCBs.
RESIDUAL POLYCHLORINATED BIPHENYLS Because of their chemical and physical properties, PCBs can be found in soils and waters long after a discharge has occurred. This source of PCBs to the environment will diminish with time. To maintain con trol of losses, emphasis should be directed toward discharges resulting from current and future uses of PCBs.
Since this problem of background levels occurs with all materials in varying degrees, we propose the following revisions:
From Section I29.01c(b), Subpart A, Part 129, 40 CFR, delete the words "in intake waters for a discharger".
Add an additional definition in Section 129.01a:
"Background" means amounts of toxic pollutant (1) presently found in the waterways of the United States (including the intake waters of
0046655
PCB-ARCH0743393
- 20 -
a discharger, or (2) arising out of operations subject to this Part that occurred before the effective date of this Part, but were not discharged to the waterways of the United States before the effective date of this Part.
PCB DISCHARGE CONTROL - MANUFACTURING FACILITY
During the late 1960's, as more data were developed
indicating PCBs could possibly be affecting certain
forms of wildlife, Monsanto voluntarily undertook
a two-phased program to keep the product out of the
environment. One phase involved the limitation of
sales of PCBs which was described
The second
phase involved the control of discharges at our manu
facturing location.
Since 1969* we have invested more than 22 man-years of work and millions of dollars in this program.
In our manufacturing area, we have taken a number of significant steps to contain PCBs. In essence, we have made the department a "concrete bathtub". Drain age is directed to trenches and piping, and then to one of two 3,000-gallon settling basins. This in sures PCB containment in case of accidental spill or equipment failure.
00^
PCB-ARCH0743394
- 22
that we can monitor the effluent from the department. In addition, this will prevent any unknown buildup of PCBs in our sewer systems or any contamination of PCBs into other sewers.
Much of the success of our efforts also depends on maintaining a high housekeeping level in the depart ment itself. Among the housekeeping responsibilities our operators have assumed, are these:
All pumps are checked for leakage on every shift. Drip pans that collect leaks are emptied into scrap PCB drums.
All leaks are reported and documented so that corrections can be made and settling basins observed.
"FloorDry" is used to absorb any liquid PCBs that have spilled or leaked. If It be comes necessary to flush PCBs to the settling basin, a minimum amount of water Is used.
Sampling drums and scrap PCB drums are quickly palletized, labeled, and transferred to the incineration area.
Through these kinds of programs, we feel we have literally built a ''concrete bathtub" to catch and
00**bbt>6
PCB-ARCH0743396
- 23 -
safely dispose of PCBs at our manufacturing location.
We have also developed sophisticated systems to monitor our effluent. Monitoring effluent streams for PCBs is not an easy effort. Measurement can be changed dramatically by taking the sample at different places along the sewer main, by changing the level at which the sample is taken, by changing the speed at which the sample is taken, or by varying the velocity of the effluent. But we have purchased the best available laboratory equipment, which enables us to determine PCB content in the parts-per-billion range. Here again, however, many factors affect our findings. The minimum detection level of PCBs on a routine basis contained in distilled water is one part per billion ( + 25$). If "dirty" water - i.e., that containing other materials which interfere with the determination of PCB -- is analyzed, the minimum detection level is 100 ppb + 25$. Monitoring is difficult. But we feel with our experience and acquired "know'how", we're doing the best possible job. And we do this job 24 hours a day, 365 days a year.
We have also established loading and shipping safe guards to minimize accidental PCB loss during trans portation. Specific written instructions are on every container we ship.
00
PCB-ARCH0743397
We have provided facilities for safely disposing of used PCBs returned from customers. As mentioned above, we installed a specially designed PCB incinerator, at a cost of $790,000. We have received an operating permit from the Illinois EPA for this Incinerator, which meets all EPA requirements. This incinerator completely destroys PCBs received either from our manufacturing area or from customers.
Finally, we have moved toward the manufacture of a more biodegradable polychlorinated biphenyl . In 1971, we installed a new distillation column in our manu facturing department at a cost of $970,000. This allowed us to separate the higher chlorinated, less biodegradable compounds from the lower chlorinated, more biodegradable ones. Our PCBs are known by the trade name Aroclor. We manufacture different grades of Aroclor (1016, 1242, 1254, for example). The lower the grade number, the less chlorinated and more biodegradable is the product.
The attached table reflects how our production mix
has changed to more biodegradable products while the
production of higher chlorinated less biodegradable
products has declined.
0.046660
We believe we can confidently assert that we have taken
strong measures to contain PCBs and keep then out of
the environment.
.
. vt_
*
J&-c-
<1 4
iu<.
-
AROCLOR PRODUCTION AT THE Wm. G. KRUMMRICH PLANT
KEY
Aroclor
1016
1242
1248
t
More biodegradable
1254 1260 1262
Less biodegradable
I
M POUNDS
0046661 PCB-ARCH0743399
- 26 -
SUMMARY
1. Actions by Monsanto and its customers, which have resulted in limiting the use of PCBs only to electrical applications in hermatically sealed units, have dramatically reduced the quantities of the more persistent PCBs introduced directly into the environment.
2. There are over 200 chemical entities collectively known as PCBs. The chemical and physical charac teristics of each of the isomers are not all alike. There is ample evidence that the higher chlorinated isomers are the type found in wildlife organisms and are, therefore, of environmental concern. We have proposed a definition describing the more persistent PCBs.
3. We are concerned with the accuracy and reproducibility of results attainable between laboratories using currently-available sampling and analytical tech niques and further studies are proposed.
4. We are concerned with a PCB effluent standard based
on inadequate toxicity information on a non
typical fish species and on an unusually high
and unique bioaccumulation factor. We sincerely
believe good scientific information is lacking and
no responsible standard can be developed at this
time.
*66^
PCB-ARCH0743400
- 27 -
5. We object to a limitation of 10,000 cubic feet per second being arbitrarily assigned as a maximum stream flow without a sound technical basis de monstrating adverse effects.
6. We believe the presence of background levels of PCBs should be considered and propose a definition which would be helpful.
7. Control practices followed at our manufacturing unit have effectively contained PCBs.
Our purpose in commenting on the proposed standards is to aid the Agency in the development of realistic efflu ent standards which will achieve the intended objectives without serious technical, social and economic disrup tions. We recognize the seriousness of this endeavor and find a statement made by Mr. John R. Quarles, Jr., Deputy Administrator, Environmental Protection Agency, of considerable interest. At a recent conference, Mr. Quarles (31) stated:
"We have found it virtually Impossible to devise intelligent standards which specify an appropriate degree of control over toxic pollutants irrespective of the sources of those pollutants and factors affecting the feasibility and timing of their abatement."
PCB-ARCH0743401
0 * 6(
- 28 -
We can appreciate Mr. Quarles' concern, particularly as it applies to PCBs. Lacking good scientific in formation on the fate and effects of PCBs in complex water systems each having unique characteristics, we urge extreme care be taken to avoid the promulgation of effluent standards which are unattainable and un warranted.
Respectfully submitted.
00*666*
PCB-ARCH0743402
REFERENCES CITED
1. Interdepartmental Task Force on PCBs, "Polychlorinated Biphenyls and the Environment", COM-72-10419, May, 1972
2. Risebrough, R.W., Vreeland, V., Bulletin of Environmental Contamination and Toxicology, 8: 345 (1972)
3. Zitko, V., Bulletin of Environmental Contamination and Toxi
cology, 6: 464 (1971)
~
" '
4. Jensen, S., Johnels, A.G., Olsson, M., Otterlind, G., Nature,
224: 247 (1969)
------------
5. Bailey, S., Bunyan, P.T., Nature, 236: 34 (1972)
6. Grant, D.L., Phillips, E.J., Villeneuve, D.C., Bulletin of Environmental Contamination and Toxicology, 6: 102 (197IJ
.i,* J ? ScF ?? J (T~7 >f ^ :, vf.Dj, Cornell, H.J., Journal of^BiQloglea^S'tTemlstry,
Crosby, D.G., Moilanen, K.W., Bulletin of Environmental Con
tamination and Toxicology, 6: 37^ (1973)
'
`
9. Panel on Hazardous Substances, Environmental Research, 5: 249 (1972)
10. Koeman, J.H., et al.. Nature, 221: 1126 (1969)
.11 Sissons, D., Welti, J., Journal of Chromatography, 60: 15 (1971)
.12 Bagley, G.E., et al.. Journal of the Association of Official Analytical Chemists, 53: 251 (1970)
13. Bidleman, F.F., Olney, C.E., Science, 183: 516 (1974)
14. Food Chemical News, October, 1973* p. 2: "No PCB residues that could be quantitated have been found in FDA's last 10 market basket surveys, FDA says...."
15. Statement obtained from Dr. George Harvey, Woods Hole Oceano graphic Institute 1/9/74; permission to quote given.
"In the summer and fall of 1972 the surface waters of the Eastern and Western North Atlantic ocean had an average PCB concentration of 30 parts per trillion. By the summer and fall of 1973> the average PCB concentration in the same areas had decreased to about 1 part per trillion.
"Since the suspended solids fall out and mixing rates of the ocean are constant, the observed reduction in surface layer concentrations indicate a reduced PCB input."
0046665
PCB-ARCH0743403
-2 -
16. Department of the Environment, Water Pollution Research 1972, Report of the Director of Water Pollution Research, London
17. Evans, W.C., Lunt, D., Biochemical Journal, 118: 54P (1970)
18. Catelani, D., Sorline, C., Trecean, V., Experientia, 27: 1174 (1971)
19. Ahmed, M., Pocht, D.D., Can. J. Microbiol., 19: 47 (1973)
20. Ahmed, M., Pocht, D.D., Bulletin of Environmental Contamina
tion and Toxicology, 10: 70 (1973)
"
21. Tucker, E.S., Saeger, V.W., Hicks, 0., submitted to editor Bulletin of Environmental Contamination and Toxicology, 2/5/74
22. Crump-Wiesner, H.J., Peltz, H.R., Yates, M.L., J. Res. U.S,, Geo, Survey, 1: 603 (1973)
23. Duke, T.W., Lowe, J.I., Wilson, A.J., Jr., Bulletin of Environ mental Contamination and Toxicology, 5: 171" (1970)
24. Greichus, Y.A., Greichus, A., Emerick, R.J., Bulletin of En vironmental Contamination and Toxicology, 9: 321 (1973)
25. Hansen, D.J., Parrish, P.R., Lowe, J.I., Wilson, A.J.,Jr., Wilson, P.D., Bulletin of Environmental Contamination and Toxicology, 6: 113 (1971)
26. Quarles, J.R.,Jr., Remarks to Conference on Industry and Clean Water, Midwest Research Institute, Kansas City, Missouri, January 17* 1974
27. Nimmo, D.R., Blackman, R.R., Wilson, A.J., Jr., Forester, J., Marine Biology, 11: 191 (1971)
28. Ryter, J.H., "The Use of Plowing Biological Systems in Aqua culture, Sewage Treatment, Pollution Assay, and Food Chain Studies." Woods Hole Oceanographic Institute, Woods Hole, Massachusetts. Unpublished Manuscript. (1972)
29. Stallings, D.L., Mayer, F.L.,Jr., Environmental HealthPer spectives, 1: 159 (1972)
0046666 PCB-ARCH0743404