Document emDnEOzEm5aMNBrJY250mv8d4
ETHYL CORPORATION
INTER-OFFICE
To B.J. Lentz
Address
BRP
From Subject
R.F. Cope, Jr.
Address
BRT
Vinyl Chloride Personnel Monitoring Data Date
June 20, 1975
Quality Control Laboratory - Baton Rouge Plant
Attached are the subject data which has been obtained from 2/28/75 to 5/21/75. The data is presented in five tables. A summary of all personnel monitoring data for the laboratory is shown in Table 1 while individual exposure data is presented in Tables 2 through 5.
VC1 Analytical Lab Technicians
As indicated by the data, there were 5 out of 8 samples greater than the action level of 0.5 parts per million (ppm). Three of these five excursions were over the 1.0 ppm VC1 standard.
Fractometer Operator
Personnel exposure to VCM in this job function was minimal due to not handling any VCM during the time periods in which monitoring was conducted.
Stock Room Operator
No VCM sample containers were handled during the periods in which monitoring was conducted.
VC1 Laboratory Supervisor
Exposure to VCM was minimal in this job function when monitoring was conducted.
General Comments
As indicated, there are some excessive VCM exposures occurring rather frequently in the analytical lab technician job function. It is difficult to pin point the reason, or combination of reasons, for these excursions. However, these excursions do occur often enough to warrant a more thorough look for possible reasons. Possibilities for these exposures may be poor, or inadequate, capture velocity of the laboratory hood, turbulent air flow in the face of the hood, accidental release of VCM samples when someone is engaged in analysis, and personnel may be exposed outside the laboratory (i.e. when going to the hydrocarbon plant to get samples).
3851
Other job functions in the laboratory that handle VCM should be monitored whenever they are actually working with vinyl chloride. Perhaps this can be arranged in the near future.
Routine VCM monitoring efforts by Corporate Medical Department personnel at the Baton Rouge Plant is expected to continue on a monthly basis--particularly in those areas and job functions where VCM exposure values are equal to or greater than the action level (0.5 ppm). Even though this is a continuing monitoring program it should also be viewed as an intergral part of the overall industrial hygiene activity at this facility.
If questions or comments arise about the exposure data or the monitoring program, just let me know and I will be happy to discuss them anytime.
RFC:daw
cc: D.E. Park W.E. Rinehart, Sc.D. T.R. Robinson, M.D.^ W.C. Strader
/^. 5^ C--y2
R.F. Cope, Jr. Industrial Hygienist
C 3852
Table 1
Summary of Personnel Monitoring Values for VCM - Quality Control Laboratory - Baton Rouge, Louisiana
Job Function
Dates
No. of Samples
Average (ppm)
Range (ppm)
Comments
VC1 Analytical Lab Technician
Fractometer Operator
2/28-5/21/75 2/28-5/21/75
8 8
No obvious reason
0.8
<0.1-2.0
noted for excursions
0.1
<0,1-0.2
Below action level.
Stock Room Operator
i
VCl Laboratory Supervisor
2/28-4/18/75
5
4/14-5/21/75
6
0.1
<0.1-0.2
Below action level.
No obvious reason
0.1
<0.1-1.0
noted for excursions
rn n
(a)
oo tfi
Noite: Respirators are worn in areas where exposures are anticipated.
Job Title and Name
Date
VCl Analytical Lab Technician
Murray - Employee #4711
2/20/75
1 Gianelloni - Employed #5617
New-Employee #4709
4/14/75 4/16/75
Handy - Employee #5506
4/17/75
Whitehead - Employee #5646
4/18/75
Major - Employee #5619 Drago - Employee # 5584 Drago - Employee #5584
5/19/75 5/20/75 5/21/75
Table II
Rate & Duration
1.5 1/min X 242 min. 1.6 1/min X 241 min. 1.5 1/min X 249 min. 1.5 1/min X 254 min. 1.75 1/min X 243 min. 1.55 1/min X 241 min. 1.55 1/min X 237 min. 1.55 1/min X 122 min.
Cone. (ppm)
Comments
0.5
0.3 1.6
0.6
2.0
<0.1 <0.1
1.1
Lab work and got samples in hydro carbon area.
In lab most of time.
In lab most of time. Out of lab/1-: 1.0 hrs. to make gas test.
Most of time in lab. In Change Housed 4 5 min.
In lab most of time. Wont to cafeteria ~'30 min.
In lab and VCl area.
In lab most of time.
VCl leak from sample container (bombs) Valve had apparently stuck.
Notei Respirators are worn in areas where exposures are anticipated
Table III
Job Title and Name
Fractometer Operator Karns ~ Employee #4710
Date
Rate & Duration
2/28/75
1.60 1/min X 241 min.
Karns - Employee #471t 0 Karns - Employee #4710
4/14/75 4/16/75
1.75 1/min X 242 min. 1.5 1/min X 243 min.
Karns - Employee #4710
4/17/75
1.75 1/min X 245 min.
Karns - Employee #4710
4/18/75
1.50 1/min X 249 min.
Karns - Employee #4710
Karns - Employee #4710 Karns - Employee #4710
T| o <CDi\ (M
5/19/75
5/20/75 5/21/75
1.55 1/min X 240 min.
1.55 1/min X 237 min. 1.6 1/min X :122 min.
Note: Respirators are worn in areas where exposures are anticipated
Cone. (ppm)
Comments
oCM
<0.1 <0.1 <0.1 <0.1 <0.1 <0.1
0.2
No VCl samples run during monitoring period.
No VCl samples run during monitoring period.
No VCl samples run during monitoring period.
No VCl samples run during monitoring period.
No VCl samples run during monitoring period.
No VCl samples run during monitoring period.
Routine operation
Routine operation
Table IV
Job Title and Name Stock Room Operator Aydell - Employee #4719 Browning - Employee #4708 Browning - Employee #4708 Mixon - Employee #4833 Browning - Employee #4708
Date
2/28/75 4/14/75 4/16/75 4/17/75 4/18/75
Rate & Duration
1.55 1/min X 244 min. 1.5 1/min X 235 min. 1.75 1/min X 242 min. 1.5 1/min X 244 min. 1.5 1/min X 247 min.
Cone. (ppm)
Comments
<0.1 0.1 0.2 0.1
<0.1
No handling of sample containers
No handling of sample containers
No handling of sample containers
No handling of sample containers
No handling of sample containers.
T|
n
ccoo C01f'
Note: Respirators are worn in areas where exposures are anticipated
Table V
Job Title and Name
Date
VC1 Laboratory Supervisor Faller - Employee #6944 Bonaventure - Employee #7259 Bonaventure - Employee #7259 Bonaventure - Employee #7259
4/14/75 4/16/75 4/17/75 4/18/75
Bonaventure - Employee #7259 Bonaventure - Employee #7259
5/20/75 5/21/75
Rate & Duration
1.5 1/min X 240 min. 1.5 1/min X 240 min. 1.5 1/min X 240 min. 1.5 1/min X 203 min. 1.6 1/min X 242 min. 1.55 1/mini X 121. min.
m r>
0)
00
c/I
'J
Cone. (ppm)
Comments
<0.1 0.1
<0.1 <0.1
<0.1 0.1
Routine work
Routine work
Routine work
Routine work Left lab
Routine work
Leak in VCl sample container. Slight exposure.
Note: Respirators are worn in areas where exposures are anticipated