Document em374JyrOnwGYKXkDMRo23x7p

y-- 'W .-V 3>-' ;^lFGoodrich ^--5--11-- ' - INTER-ORGANIZATION CORRESPONDENCE TO FROM SUBJECT FIELD POINT OR DEPT. % BLDG. NOPhillip Oonataccio FIELD POINT OR DST. a BLDG. NO. Diana Friesz DATE YOUR LETTER DATE IMIS LfTIEft Julv 15. 1992 Second Quarter 1992 Industrial Hygiene Summary - Henrv Plant Henry Plant personnel monitoring results for April through June of 1992 are summarized as follows! X. NOISE (BFG Exposure Limit * 50% dose) {OSHA PEL - 100% dose) AREA JOB CLASS NOISE EXPOSURE BY AREA NO. OF EXPOSURE MAXIHUM NO. OF MONITORINGS AVERAGE EXPOSURF MONITORINGS >50%/>100% (% DOSE) (% DOSE' Dryer Bldg. (732) Poly Bldg. (731) Maintenance (713) Warehouse (735) Dryer Operator Foreman Silo Operator Recovery Operator Paste/LoSope Operator Foreman PC Maintenance Machinist Warehouseman 6 1 2 1 6 3 1 1 1 3/3 1/0 0/0 0/1 2/2 1/0 0/0 0/0 0/0 123.11 72.47 32.93 103^20 63.68 34.82 24.36 10.34 37.16 205.88 72.47 45.36 103.20 112.30 54.60 24.36 10.34 37.16 Hearing protection was worn by all employees exposed to noise in excess of 95 dB (50% dose). BFG-49S6-E MSO Prinilno Co, Henry, HI. 6153? NGC 14685 II. DUST (OSHA PEL - 10 mg/K\ 8-HR TWA) Operators in the Dryer building were monitored for exposure to PVC total dust. A personal sampling pump (2.0 LPH) with a dust cassette and 5 micron PVC fitter (pre-and post-weighed) were used. There were no exposures exceeding the permissible limit. JOB CLASS NO. OF MONITORINGS AVERAGE EXPOSURE MAXIHUH EXPOSURE Bagger Spray Dryer Operator Pearl Dryer Operator Contract Bagger 1 2 1 2 2.51 1.99 0.77 0.36 2.51 2.93 0.77 0.56 III. CARBON TETRACHLORIDE (OSHA PEL - 2 ppm* 8-HR TWA) ISOPROPYL ALCOHOL (OSHA PEL - 400 ppm* 8-HR TWA) METHYLENE CHLORIDE (Current OSHA PEL 500 ppm. proposed OSHA PEL - 25 ppm, 8-HR TWA) A laboratory operator was monitored with a large charcoal tube and personal sampling pump on a day when the above listed chemicals were used. The result of this monitoring was 0.4 ppm (CCL4)* 1.98 ppm (IPA) and 1.98 ppm (Mecl2) IV. ACETONITRILE (OSHA PEL - 40 ppm, 8-HR TWA) Two 3114 operators performing various jobs were monitored for full-shift exposure to acetonitrile using a charcoal tube and personal monitoring pump. The exposure results were 0.44 ppm and 0.74 ppm. V. ACETONE (OSHA PEL - 750 ppm* 8-HR TWA) Two laboratory operators were monitored for full-shift exposure to acetone using a large charcoal tube and personal sampling pump. Both exposures were less than 2.0 ppm. VI. TOLUENE (OSHA PEL - 100 ppm, 8-HR TWA) Two Crude building operators, one X-70 operator and one OBTS (front end) operator were monitored for Toluene exposure using a 3M gas badge. All exposures were less than 1 ppm. VII. VINYL CHLORIDE (OSHA PEL - 1 ppm, 8-HR TWA) During the second quarter of 1992 there were 54 monitorings completed for vinyl chloride exposure (32 poly/22 dryer). Of the total monitorings* 9 (17%) exceeded l ppm and 40 (74%) were below 0.5 ppm. There were four monitorings* three in the poly building and one in the dryer building* that were above 1 ppm without respirator protection. These exposures are summarized below* NGC 14686 Date 4/03/92 4/03/92 5/15/92 6/12/92 Operator Job Exposure Level Hike Schaefer Joe Purtecher Wayne Hastings Harold Sprague Ran R/S Prime and bagged Charge and recover LoSope Charge F76 and 213 Charge and recover LoSope 1.5 ppm 1.4 ppm 3.60 ppm 2.2 ppm VINYL CHLORIDE EXPOSURE BY JOB CLASSIFICATION 1 NO. OF NO. AVERAGE MAXIMUM JOB CLASS MONITORINGS ABOVE 1 DBm EXPOSURE (DDm) EXPOSURE (DDm PVC Tank Farm 1 Poly Cleaner (enters polys) 3 Pearl Charge Operator 4 Paste/LoSope Charge 7 HRC Poly Cleaner/Helper 6 Recovery Operator 6 Dryer Operator 8 Poly Foreman 3 ! Valve Cleaner Contract Bagger 1 3 Dryer Foreman 3 i Catalyst Makeup Bagger 1 5 Silo Operator 3 1 2 1 2 1 1 1 0 0 0 0 0 0 0 1.9 1.6 1.06 0.91 0.57 0.36 0.36 0.34 0.23 0.18 0.14 0.13 0.11 0.07 1.9 2.5 3.6 2.2 1.7 1.2 1.5 0.60 0.23 0.24 0.24 0.13 0.15 0.07 VII. MEDICAL SURVEILLANCE SUMMARY i Total number of Examinations - 48 Number of Examinations which showedt a. Hearing loss - 4 b. Report by Department Compounding - 1 (confirmed STS) PC - 1 (to be retested) PVC - 2 (to be retested) Follow-up Activities! .1 Send letter to each employee stating they have a . S.T.S. 2 Retest each employee within 21 days. 3. Reinstruct each employee in the proper use of hearing protection. Reevaluate their working area. i NGC 14687 REDACTED IX. PEL EXCEEDENCE INVESTIGATIONS Board o Inquiry meetings were held for the second quarter vinyl chloride exposures that were greater than 1 ppm without respirator protection. Two exposures from the first quarter were also discussedi 1.6 ppm for Hark Hoffman on 1/31/92 while charging suspension resin and 1.1 ppm for Neil Thle on 3/22/92 while cleaning the ultrafiltration unit. FACTS SURROUNDING THE INCIDENTS 1. Charging Pearl resin on 1/31/92. 2. He was absent from the meeting due to a recent transfer to the LaPorte Plant. 1. An experienced Foreman in the resin area. 2. While performing his normal duties* he assisted In the clean-up of the Ultrafiltration unit. 3. Past personal monitoring data has not shown high monitoring results for this task. 4. The building ventilation fans were not working properly, therefore Ammonia fumes were higher than normal in the building. 1. Hike has 3 years of service in the resin area. 2. He was operating the Resin Reclaim Dryer on prime material. 3. He bagged some resin while operating the dryer. 4. The dryer press was leaking water during the cake wash cycle due to a faulty diaphragm plate. 5. Mike was experiencing some feed plugging problems to the dryer. 6. He did not enter the Poly Building on this day. 1. has 17 years of service in the Geon area. 2. He was charging and recovering LoSope. 3. Building monitoring lights were low* 5 lights above 1 ppm 2 lights above 3 ppm Q lights above IS ppm 4. The monitoring badge was exposed to Aqua Ammonia fumes. NGC 14688 REDACTED 1. Wayne has 14 years of experience In the Geon area. 2. He charged F76 and 213 during the shift. 3. He found the poly evacuation blower not running. 4. Both ~ * *" were monitored on the same day. 5. Wayne assisted in recovering the line to replace a valve in the Vinyl header to Poly #1. 1. Results of the Board of Inquiry have not been finalized yet. CORRECTIVE ACTIOHS 1. Complete area monitoring of Ultrafiltration Building during cleanup. - Rod Margin 2. Review past records for high readings during clean-up procedure. - Diana Friesz - completed. Reviewed 1991 and 1992 (thru Hay) data. Ho other high exposures were found. 3. Replace bad diaphragm plate. - A1 Skutt - completed. 4. Complete area monitoring of 2nd floor in Resin Reclaim Building. - Rod Martin. Monitor at H/E corner of press on 6/14 * B.84 ppm 5. Conduct OVA monitoring of Resin Reclaim wet hopper. - Rod Martin. Initial readings indicate that VCL levels inside of the wet hopper door may be higher if the blow back system in the flex kleen is not operating - continue investigation. 6. Monitor LoSope Operator during various tasks. - Rod Martin - completed. 7. Remonitor exposed operators - Rod Martin. M. Hoffman - transferred to LaPorte Plant H. Thie - 0.13 ppm (4/27), 0.057 ppm (5/17) M. Schaefer - 0.32 ppm (5/11). 0.40 ppm (S/29) J. Purtscher - 0.88 ppm (5/11), 0.19 ppm (5/29) W. Hastings - 0.065 ppm (6/14) 8. Re-emphasize the correct procedure for opening the poly manhead. - Rod Martin 9. Spike a sample badge with Ammonium Laurate fumes to determine VCL interference potential - Diana Friesz - completed. Badge suspended over jar of ammonium laurate for 7 hours on 6/16 0.09 ppm. There is no apparent interference. . NGC 14689 10. Investigate the poly exhaust system for proper air flow. Ron Hoore 11. Replace Poly #1 Vinyl valve. - completed 12. Start poly exhaust blower. - completed 13. Identify records so people with same last name are monitored on different days. Please call me at 9407 if you have any questions on this information. DF/bs/92 15 cci D.M. V.D. R.I. R.D. D. L. D.E. R.D. W. J. J.D. K. W. M.E. Kidd Marquis Brinly Moore Picclnelli Giffin Webber Grudzinski Krumholz Prather Guyer Diana Friesz J.B. Mattingly T.L. Castor J.D. Schwarz K.E. Musselman D. Gleghorn - Cleveland R.J. Grahek - Cleveland K.J. Millings - Brecksville S&E Operators (2) PVC Foreman (4) PC Foreman (4) File REDACTED NGC 14690