CHAPTER 42
1955 GSig
or another, charges both for demand and energy. Demand may
dicated directly by a demand meter or be derived from manufactuj^jjL,
rating data shown on nameplates of the heating equipment. In block-tyh|C
rates, where demand is not specifically mentioned, it is in part reflected^/"
higher charges per kilowatt-hour in the earlier blocks.
, '*
Control of Electric Demand
To obtain electricity for space heating at minimum cost, it is necessaft to keep the user's kilowatt demand as low as possible, by provisions'iifr original design of the installation and by judicious methods of operatic])?' Excess heating capacity should be avoided, but without jeopardizing satis-1 factory performance in cold weather. A variety of control methods can be; applied to minimize both demand and consumption. Decentralized con-1 trol with a thermostat in each room or on each heating unit, together with manual switch to cut off any unoccupied room, is one method. Sequence' switching whereby electric service to individual rooms or circuits is shifted in rotation by an automatic timing device and sequence is modified by out door thermostat or by total electric load, is another.
Load-limiting controls of several types have come into use. These, are generally arranged to measure the customer's total power demand, which for a residence may be grouped as lighting and miscellaneous ap pliances, refrigerator and water heater, cooking range, and the space heating system. When the demand exceeds a preset value, one or more heating circuits are cut: off progressively in rooms least affected by the inter ruption. Experience shows that with electric floor or ceiling panel heating, temperature drop occurs slowly, at the rate of about 1 deg per hour for concrete slabs and 2 deg for plaster construction or rigid panels properly backed with thermal insulation. Moreover, electricity consumed by light ing, appliances and cooking ranges is contributing some useful heat at such times.
Another form of limiting control for 120/240-volt 3-wire circuits pro-; vides complete or sequence transfer of space heating units from 240 volts to 120 volts, thereby reducing the electric input to one quarter whenever the total load or general-service component exceeds a preset limit.- This method lends itself to use of an outdoor thermostat actuating a relay,' whereby in mild weather the entire heating system operates at 120 volts and with lengthened cycles obtains more uniform room temperature. For reducing temperature at night, if desired, a clock-operated master thermo-.' stat can be provided to lower the heating-system voltage. On some electric utility systems, centralized control by means of a pilot-wire or carrier-current actuating a relay is applied to house-heating installations.
With any type of control, time-delay relays should be used in order that upon restoration after an emergency service interruption or whenever a master thermostat calls for heat, the individual circuit or units will come on non-simultaneously over a period of a few minutes. This is advisable especially for types of resistor units that have a power input, when cold, as much as 50 percent above the rated value at normal operating temperature.
Operating Costs
The range of electric costs for house heating, on residential rate schedules typical of country-wide conditions, is from something over two cents per kilowatt-hour where house-heating consumption comes mainly on tte
969
v'bottom step of a block-type residential rate, to as little as half that figure "m areas served by large hydroelectric systems. Since the range of heat
factors for houses of differing construction types with various methods of resistance electric heating and with a variety of occupancy is likewise more than 2-to-l, costs of house heating for dwellings of the same size in similar winter climates may vary through a range of nearly 5-to-l. However, an
Table 3. Relation of. Resistor Voltage to Heat Delivery
Condition
Electric system, nominal value.....................................
For design of equipment, at terminals.......................
Range, as basis for design
Minimum.........................i..................... ..........................
Maximum..........................................................................
On secondary distribution system
Favorable zone, as to voltage conditions Minimum.......................................................................
Maximum.......................................................................
Tolerable zone
Minimum............................. .........................................
Maximum, , .
........................
Kmergency conditions.......................................................
Volts
120/240 118/236
110/220
124/248
110/220
125/250
107/214 127/254
90/180
Heat Delivered
%-
103.3
100
86.8 110.5
86.8
112.0
82.2 116.8 58.3
8000-cu ft house can be heated with 8000 kilowatt-hours of electrical energy annually in 5000 degree-day climate, if a heat factor of 0.2 is attained by means of good construction and adequate insulation.
Voltage Requirements
The preferred nominal system voltage at point of electric utilization by equipment, for single-phase 3-wire systems necessary with space heating, 120/240 volts, as stipulated by standards of the electrical industry (EE1 publication R-6 and NEMA publication No. 117 issued May 1949). For household heating appliances mentioned in the standards, such as air beaters, water heaters, and cooking ranges, the equipment voltage rating lor design is specified as 118/236 volts, and the range of voltages to be used os o basis of design extends from 110/220 minimum to 124/248 maximum, ncnvever' naturally variations exist from time to time in the conditions a different points in any secondary distribution system and will affect th voltage level and range of fluctuations. Under emergency conditions o electricity supply systems, voltages of the order of 90/180 may be
countered. Heat delivery by resistors with these voltage values, ex pressed in percent of rated delivery with the normal 118/236 volts (at lermmals) ;s gjven in Table 3
.^hges stipulated for secondary distribution systems are at point of
\vir ICe en*,rance to the building; the drop of voltage in the house supply du Ul t,Rrm*nals of the heating equipment may be 2 to 3 percent, thus re-
^lnS neat delivery by some 5 to 8 percentage points below the favorable e ann tolerable zone values included in the last column of Table 3. Ac-