Bendix VCM Monitoring Data Analysis Flemington Plant October 11, 1975 to 0ctober24 , 1975
DATt November 6, 1975
Copy to
W,, D. Bord
De M, Hcrshkowitz P. A,, Lobo W. Hiringoff F,, X,, Ritter M, K. Rosen P,, R* S carl to F. Toca
Attached is the subject analysis.
COLOR!TE 006427
'oint No.
RE-1 RE-2 RE-3
Bendix Monitoring Data Analysis
Flemington Plant
October 11, 1975 - October 24, 1975
Readings (PPM VCM)
Point Location
Center Aisle, Fiist Floor
Remarks: Problem is believed to be the result of reactor washouts - washing frequency has been reduced by 507,.
Total 966
>5 13
>25 3
RE-4
No. 1 and 2 Slurry Pumps, First Floor
966
16
z
RE-5
RE-6
Remarks: problem is believed to be
the result of chip basket washouts -
more data is being generated.
RE-7 RE-8
Recovery Compressor Room
Remarks: Intermittent leaks in vacuum pump and compressor systems.
992
93
RE-10 RE-11 RE-12
Center Aisle, Second Floor
i
Remarks: General ventilation problem related to reactor ventilation, reactor washout and vent condenser discharge. Engineering estimate is now being prepared covering relocation of reactor ventilation. Vent condenser discharge has been relocated, data being generated
970
46
6
RE-13 RE-14 RE-15
Stripper Platform, Panel board area Second Floor
Remarks: General ventilation problem . as for RE-10, RE-11, RE-12.
975
75
7
RE-16
Knock-out Tanks, Second Floor Remarks: No defined source as yet.
325
23
3
>100 1. 0 0 0
0 0
i
COLORITE 006428
'oint No.
!E-17
Bendix Monitoring Data
Analysis Flemington Plant
_
October llj 1975 - October 24
1.975 Readings (PfM VCM)
Point Location
West Wall Between Styrene Tank, Se.cond Floor
Remarks: No defined source as yet possibly vent condenser or compressorroom. Vent condenser discharge has been relocated.
Total 360
>5 20
>25 1
IE-18
Gelatin Make-Up Area, Second Floor
650
44
4
IE-19
Stairwell, Second Floor
Remarks: No defined source as yet possibly vent condenser or compressor room.
>10 1
0
GENERAL AREA
)
Quality Control Labs Westj
Remarks: Inadequate ventilation Engineering re-design in work Priority 1 project.
1-9 VCM Pumps
Remarks: Pump seal leakage - ultimate solution is conversion to "canned" pumps. Engineering is working on the development of a suitable pump.
1-10
Tank Car Unloading
Remarks: Ilose disconnect operation Engineering is currently working on re-design - priority 2 project.