Document e7p2RVD4aVvEan8g7K8k7VxVp

vS'*' ta ./> v .> cv November 7, 1983 Hr. David Lasnier, General Manager A.W. Chesterton 9 Forbes Street Woburn, MA 01801 A THE HARTFORD Soaton Regional Office Two Center Plaza Boston. Massacnusetts 02108 Teiepnone: (617) 726-7400 RE: Loss Control Service A-690 Dear Dave: This letter will confirm my visit with Bob LeDuc at Chesterton's Woburn Research Plant on August 30, 1983. As in the past, purpose of the visit was to collect asbestos samples during the removal of packing material from pumps operating under field, conditions. The ( need for this sampling was documented during previous monitoring when it was decided that to approximate actual operating conditions, sampling would be necessary during removal of packing materials. This latest attempt at 1 !> determining airborne concentrations of asbestos fliber involved removal of "product A" that had run for approximately 100 hours during a field test situation. As can be seen from the results listed below, no measurable amount of fiber was detected during the samples, and all results indicate exposure concentrations of less than 0.1 fibers per cc of air. Jack Sar.tolucito and the area to his left (approximately 6" to the left side of the shaft) at the height of the pump were monitored on 8/30/83 during removal of 5 pieces of "product A" packing that had run for approximately ICO hours in a field simulated test. The pump was repacked with "product B". Name/Area Q Total Time Volume (L) (minutes) Fibers Flbers/cc Jack Santoluclto Area to left 1 2 15 15 30 < 3,000 < 0,1 30 < 3,000 <0.1 OSHA's permissible exposure limit OSHA's administrative action level 2.0 0.1 ^ "eparts are based upon observations or information avaliable mi the Dma of surveys whieft may not discover eft hazards. We cannot warrant ' *ty. I>ea/th or compliance with any rulo or regulation. Wa can only assist you in tulhlhng your responsibility m controlling accidents. Form SRE-I70-Q Loss Control Department Harlford Fire Insurance Company and !U Affiliate* Hanford Plaza. Hartford. Comaosit 0611S 1 Mr. David Lasnler bar 7. 198^ The significance of this test is simply that concentrations of asbestos fiber, if present at all, exist at levels below OSHA's adainistrative action point, and therefore do not constitute a significant threat to health. Future measure ments will necessarily need to be made utilizing other materials and under different conditions, and these results will be reported later. Hopefully this latest attempt has been of assistance to you in your effort to evaluate exposure to airborne asbestos fiber. Stephen W. Campbell,C.S.P., C.I.H Certified Industrial Hygienist cc: Horst Berhoth, Plant Engineer A.W. Chesterton 9 Forbes Street Woburn, MA 01801 Gregory Smith, Personnel Manager A.W. Chesterton 9 Forbes Street Woburn, MA 01801 Frank Boccelli, Insurance Manager A.W. Chesterton Middlesex Industrial Park Stone ham, MA 02180 Edward Bonaccorso, Corroon and Black OQ Vt-> ^ -- ao- - -"--** ---- Boston, MA 02110 Assistant Vice President SWC:mhs