Document e7REZLpXkmxLJr9mp45ygmLw9
FRICTION PRODUCTS GROUP WINCHESTER. VIRGINIA APPENDIX #1
FIELD SAMPLE #22
Fiber count75,n/ml-0.00 Lab No. - 1860 Loc. - Blank Date -- 10--2--74
FIELD SAMPLE 23
FIELD SAMPLE 24
Fiber count.>5,11/1111-2.02 Lab No. - 1861
Fiber count >5n/ml Lab. No. - 1862
Loc.-Disc preform #3
Loc.-Block prefon
Med. Study #3C-014
Med. Study #3C-16l
Date - 10-3-74
Date - 10-3-74
Time: 8:28am-10:50am
Time: 8:38am-10:4;
Sampling rate in liters Sampling rate in
per min.-1.9823
per min. - 1.9591
Air vol.(liters)-281.5
Air vol.(liters)-
Avge. count/field-3.75
Avge . count/field-
Mix used - 238
Mix used - 551-DS
Worker habits - clean
Percent long fibe
Worker height - S'lO"
mix 551--DSC - 55%
Ventilation (fpm) #3
Percent short fib
a. lower left side small mix 551--DSC - 45%
hood at face, 2,700
Work habits -- dir
b. middle left side
Worker height - 6
small hood at face
Double cavity mac
2,800
c. upper left side hopper
exhaust at face -- 600
d. lower right side small
hood at face 2,800
e. middle right side
small hood at face
2,500
f. upper right side hopper
exhaust at face - 500