Document e7478pKy9jnx79poKqapxKpQy

Heaters, Water . w-. The Patterson-Kelley Co. 99 Park Avenue - New York City Hot Water Heaters for all purposes. Pool Heaters and Converters. Preheaters, Heat Exchangers, Heaters for Chemicals, Gases, Oils. Coolers for Brine, Chemicals, Gases, Oil and Water. The Patterson Combined Hot Water Service and Storage Heater, Type B, is for any service where require ments for hot water are not constant, or where a large volume must be stored for sudden heavy demands. We guarantee to furnish heaters that will deliver the quantity of hot water called for. Without obligation our Engineering Department will be glad to give engineers the benefit of our 49 years' experience. General Specifications Constructed like a high grade boiler--of heavy steel plate. Steam inlet and outlet chamber is a heavy, grey iron casting. Tube head is a heavy, steel forging into which both ends of each tube are expanded. Tubes are of pure, cold drawn seamless copper and "fl" shaped to provide against contraction and ex pansion strains. Heater is for any service and in any required size per tables below. Write us for engineering advice. HEATING CAPACITIES-- 40 F. to 180 F.--Steam at Atmospheric Pressure No. 1H . 2H 3H 4H 5H 6H 7H 8H 9H 10H 11H I2H 13H 14H Gallons per Hour 100 150 200 250 300 400 500 600 700 800 1000 1250 1500 1750 Approx. WL in Lb. 200 215 235 255 285 315 350 370 400 425 450 500 550 600 No. 15H I6H 17H I8H I9H 20H 2IH 22H 23H 24H 25H 26H 27H 28H ' Gallons . Approx. per Hour Wt. in Lb. 2000 2500 3000 3500 4000 4500 5000 6000 7500 10000 12500 15000 20000 25000 700 800 900 1050 1200 s 1350 1500 1750 2000 3200 3800 4500 ' 5100 5800 Note--To specify Type B. Heaters, combine the numbers of the required storage and heating capacities. For example, Oxe Patterson Type B. Heater with No. 22 S. and No. 17 H." has 1000 gallons storage with 3000 gallons hourly heating capacity. ' . No. 1S 2S 3S 4S 5S 6S 7S 6S 9S 10 S 11 S 12 S 13 S MS 15 S 16 S 17 S IBS 19 S 20 S Dimensions in Inches 24 x 48 24* 60 . 24 x 72 24 x 84 30 x 60 30x 72 30x 84 30x % 30x120 36 x 72 36x 84 . 36x 96 36x 108 36x120 36x 144 42 x 72 42x 84 42 x 96 42x108 42x120 STORAGE CAPACITIES Capacity 1 Approx. in Gals. - Wt. in Lbs. No. Dimensions in Inches 94 650 118 750 141 850 164 950 180 875 215 1000 255 1150 285 1300 360 1500 310 1250 365 1400 415 1550 475 1700 500 1850 640 2100 430 1500 500 1650 575 1800 650 1950 720 2200 21 S 22 S 23 S 24 S 25 S 26 S 27 S 28 S 29 S 30 S 31 S 32 S 33 S 34 S 35 S 36 S 37 S 38 S 39 S 40 S . 42 x 144 42x168 42x192 48x % 48x120 48x144 48x168 48 x 192 54x 120 54x144 54 x 168 54 x 192 60x120 60x144 60x168 60 x 192 72 x 174 84x 168 ' % x 168 96 x 192 Capacity in Gals. 860 1000 1155 750 940 1125 1300 1500 1190 ' 1425 1665 1900 1400 1700 2000 2240 3000 4000 5200 6000 Approx. Wt. in Lbs. 2450 2800 3100 2600 - 2925 3350 3840 4200 3500 3900 4300 4700 4300 4950 5600 6200 7000 8700 10000 11000 688 Stas*. Heaters, Water The Whitlock Coil Pipe Company Manufacturers and Engineers . Baltimore, Md. Dallas,Tex. Boston. Mass. Denver, Colo. Buffalo, N. Y. Detroit, Mich. Charlotte, N. C. Houston, Tex. Chicago, III Indianapolis, Ind. Cincinnati, 0. Kansas City, Mo. Cleveland, 0. Memphis, Tenn. HARTFORD, CONN. W Heater S New Orleans, La. New York, N. Y. Omaha, Neb. Philadelphia, Pa. Pittsburgh, Pa. Portland, Ore. Rochester, N. Y. San Antonio, Tex. San Francisco, Calif. Seattle, Wash. St. Louis, Mo. St. Paul, Minn. Tacoma, Wash. Darling Bros!. Montreal, Manufacturers of Whitlock Heaters in Canada See Telephone Directory for Local Address Whitlock type "K" storage heaters are manufactured in both horizontal and vertical types. The table shows sizes of the horizontal heaters only. We will gladly furnish dimensions of horizontal heaters and vertical beaters upon request. That this type of heater is of particularly sturdy construction is evidenced by the increasing number of prominent engineers and architects who are specifying their use in au types of buildings, including many of the largest and finest buildings constructed. Whitlock Type K Storage Heaters, Horizontal SHELLS To be used with Type IC Heating Section Shell Prices include Cradle. Manhole 11**15' HEATING SECT IONS Capacity based on Heating from 40 to 180"with Steam at 0 U. pressure. For other tempera' tures and Steam Pressures see Bulletin No. 27 Gallons Diam Number One eter Filling of Shell Length Thick- Thick Weight ness ness Shell of Shell of Head Shell Number Gallons r Maximum Size Steam Pipe Inches . Smallest Shell into which Section will Fit Inches Weight Entire Heatinj Section Lbs. 1 65 18 60 14 % 2 - 3 4 80 118 141 18 24 24 72 60 72 V''AA* %y. y 5 164 24 6 185 30 7 220 30 8 *255 30 9 290 . 30 84 60 72 <4 v'A< 7y9, A 84 % ''AA VA, 10 365 36 11 .420 36 12 475 36 84 % 108 fffttt 13 525 36 120 *8 ft14 575 42 % ft15 720 ` 42 . 120 16 860 42 144 ft v<%A n<A j <A 17 1000 42 18 950 48 168 ft 120 Vb nf 19 20 21 22 23 24 25 26 . 1140 1310 1480 1190 1430 1670 1900 1420 48 48 48 54 54 54 54 60 Vt144 V. 168 192 Vb y120 y.144 168 % 192 V, 120 k '<AA VA'%At , 27 1710 60 28 2000 ' 60 29 2300 60 30 2460 72 ft144 ft 168 ft192 ft 144 f%ffttt 31 2880 72 168 % 400 450 600 700 800 750 850 950 1050 1300 1450 1600 1800 1850 2150 2500 2900 2850 3250 3700 4100 3250 3700. 4200 4700 4300 4900 5600 6200 5700 6400. H0 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 Hll HI2 H13 HI4 H15 H16 H17 H18 HI9 H20 H21 H22 H23 H24 H25 H26 H27 H28 H29 H30 100 150 200 250 300 350 400 500 550 600 700 800 900 1000 1250 1500 1750 2000 2400 2800 3200 3600 4000 4400 4800 5400 6000 7000 8000 9000 10000 2 2 2Vh vA vA vh 3Vl 3'A 3Vl 5 m3yV/if 5 5 5 6 6 6 8 8 8 8 10 10 10 12 12 12 12 18x 48 18x 60 I8x 72 I8x 48 <18x 48 I6x 60 18x 60 !6x 72 18x 72 18x 84 24x 60 18x 96 16x106 18x120 24x 84 24x108 24x120 30x 96 30x120 30x132 36x % 36x108 36x120 36x132 36x 96 36x108 36x120" 42x 96 42x 96 42x108 42x108 75 80 90 175 185 190 200 210 215 220 300 260 270 285 370 425 450 570 620 670 860 920 950 1020 1200 1300 1360 1950 2000 2300 2460 DIRECTIONS FOR USE--Select the size storage you require and combine its designating number with the number which designates the desired hourly output. Assuming a required storage of 1000 gallons (No. 17 shell 42 x 168) arui a required hourly output of 1750 gallons (No. H16 Heating unit) you would specify a Whitlock Type K No.'17Hl6. 689