. ^/JwiiAandl/ (yaAd UTILITIES DEPARTMENT OTTO H. W. BLUME, DIRECTOR May 12, 1982 John Williams 4005 Chestnut Avenue Fairfax, VA 22030 AWWA STANDARD FOR INSTALLATION OF ASBESTOS CEMENT PRESSURE PIPE Dear John: Following our telephone conversation of May 3, 1982, I have reviewed in detail AWWA C603 and offer the following comments for your review in revising this Standard. In offering these comments I would request that they be viewed in the context of suggestions only;, In general, I feel the existing Standard is adequate and as such I would not want my comments to delay the completicn of this update. flout- It is my understanding that all Standards when revised are incorporating metric equivalents, as such these equivalents should-be incorporated into this Standard. <55z> Section 2.2-1 believe this Section should be expanded to include storage requirements for ,, ruhhftr rings and stackinglimitationsand pre/ cautions for pipe storage. $ 31 & Section 3.3-1 believe this Section could be expanded to include a discussion on pipe assembly, if such techniques do not vary frcm one manu facturer to another. This comment would also apply to allowable pipe joint deflections. Section 3.3-1 believe that a note should be added which refers to AWWA Manual No. 16 "Work Practices for Asbestos-Cement Pipe". ^ 2U* Section 3.3-1 believe that this Section should be revised to include the suggested usage of a locating wire or strip. 401 WEST HILLCREST DRIVE POST OFFICE BOX 1496 THOUSAND OAKS, CALIFORNIA 91360 (805)497-8611 r ADr.o .ipm / John Williams Page 2 May 12, 1982 . Section 6-1 believe the following wordage change is warranted "existing system shall be flushed and disinfected in accordance with AWWA C601,". . In reviewing other installation standards, I have noted that C600 has a separate section on service taps. Although this subject may be quite controversial, I believe consideration should be given to the addition of such a section. While I unfortunately will not be able to attend the meeting in Miami, I do appreciate the opportunity to comment. If you have any questions or wish clarification on my comments, please call. Sincerely, DONALD H. NELSON SENIOR CIVIL ENGINEER DHN:nlh CAPCO JEN 0020557