Document e5ekY7K74Mam4gEDVV3Ozz71m

bIUUbb /b9 MICHIGAN DIVISION August 17, 1990 ^ J LaBean, 572 D. Naberhaus, 572 H. Williams, 572 cc: D. Martin, 258 A. Pollock, 258 F. Sabel, 258 <B. Shurdut, 258 T. Sponseller, 572 RE: INTERIM REPORT ON REMOVAL OF NON-FRIABLE ASBESTOS GASKETS On July 31, 1990 a simulation was conducted of the removal of non-friable asbestos gaskets. During this simulation, air sampling was conducted to evaluate employee's potential exposure to asbestos during the gasket removal and only gaskets that could be removed without scraping the material from the flange were studied. The results can be found in the attached tables. , The results indicated tfciat non-friable gasket material may be removed without exceeding current asbestos exposure guidelines. It should be noted however, that gasket materials have showrt the potential for exposure above the current guidelines when scraped from flanges rather than being removed in-whop.e. fliSSiS SSiEJliGasket *ualified individuals remove (PJ;.22cSR1926-58) which adhere to hv"thrialB which do not adhere to flanges may be removed by otlyer personnel. y Please contact me should you have any questions. Mike Dupuis Industrial Hygiene Services 258 Building Phone: 6-5864 Attachment DOW CONFIDENTIAL AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY BESTPlCTEO FOB USE WITHIN The DOW CHEMICAL COMPANY =Qualitv= Performance Means More At Dow TABLE 1. EVALUATION OF POTENTIAL1 EXPOSURES TO ASBESTOS DURING ASBESTOS GASKET REMOVAL, MICHIGAN DIVISION CRAFT SERVICES, 500 BUILDING, JULY 31, 1990. HEH2.1-1-180(4) Date Master Time iffiiHil Number Of Asbestos Gaskets Concentration (f/cc) Reasyg.4 Exvurglon Bhr TWA3 7/31/90 054960 175 13 0.07 0.03 7/31/90 065389 163 13 0.03 0.01 7/31/90 061761 70 2 0.05 <0.01 7/31/90 063366 70 2 0.12 0.02 PEL4 1.0 0.2 1. Potential - Respiratory Protection Used 2. f/cc - Fibers per cubic centimeter 3. ehr TWA - Excursion exposure converted to 8hr time-weighted average. i 4. PEL - OSHA Permissible Exposure Limit DOW CONFIDENTIAL 19iseonis TABLE 2. EVALUATION OF POTENTIAL1 SHORT-TERM EXCURSION EXPOSURES TO ASBESTOS DURING ASBESTOS GASKET REMOVAL, MICHIGAN DIVISION CRAFT SERVICES, 500 BUILDING, JULY 31, 1990. HEH2.1-1-180(4) Pafcfi 7/31/90 Master Number 063366 Time (min.) 28 Number Of Gaskets Floor Removed 1 2* Asbestos Concentratii 0.01 061761 28 12 0.01 065389 2 1 1 0.09 054960 3 1 2 0.01 1st Floor Background Sample 89 1 NA31 2 0.02 7/31/90 065389 21 2 6 0.01 065389 16 20 <0.01 (Unbolting Flange Only, Gasket Not Removed) 054960 20 24 0.03 2nd Floor Background Sample 82 2 NA 0.02 STEL4 1.0 1. Potential - Respiratory Protection Used 2. f/cc - Fibers per cubic centimeter 3. NA - Not Applicable 4. STEL - OSHA Short-Term Exposure Limit DOW CONFIDENTIAL